{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,10]],"date-time":"2025-12-10T08:49:53Z","timestamp":1765356593010,"version":"3.37.3"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2019,8,29]],"date-time":"2019-08-29T00:00:00Z","timestamp":1567036800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,8,29]],"date-time":"2019-08-29T00:00:00Z","timestamp":1567036800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"name":"Fakulti Sains, Universiti Putra Malaysia","award":["GP\/IPM\/9619800"],"award-info":[{"award-number":["GP\/IPM\/9619800"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol Phys Technol"],"published-print":{"date-parts":[[2019,12]]},"DOI":"10.1007\/s12194-019-00532-8","type":"journal-article","created":{"date-parts":[[2019,8,29]],"date-time":"2019-08-29T15:03:26Z","timestamp":1567091006000},"page":"374-381","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["A comparative study of radiation doses between phantom and patients via CT angiography of the intra-\/extra-cranial, pulmonary, and abdominal\/pelvic arteries"],"prefix":"10.1007","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5357-4193","authenticated-orcid":false,"given":"M. K. A.","family":"Karim","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Sabarudin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N. A.","family":"Muhammad","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K. H.","family":"Ng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,8,29]]},"reference":[{"key":"532_CR1","first-page":"451","volume":"24","author":"VK Jayakrishnan","year":"2003","unstructured":"Jayakrishnan VK, White PM, Aitken D, Crane P, McMahon AD, Teasdale EM. Subtraction helical CT angiography of intra- and extracranial vessels: technical considerations and preliminary experience. AJNR Am J Neuroradiol. 2003;24:451\u20135.","journal-title":"AJNR Am J Neuroradiol"},{"key":"532_CR2","doi-asserted-by":"publisher","first-page":"899","DOI":"10.1148\/radiol.2413040128","volume":"241","author":"C Schueller-Weidekamm","year":"2006","unstructured":"Schueller-Weidekamm C, Schaefer-Prokop CM, Weber M, Herold CJ, Prokop M. CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings. Radiology. 2006;241:899\u2013907. \nhttps:\/\/doi.org\/10.1148\/radiol.2413040128\n\n.","journal-title":"Radiology"},{"key":"532_CR3","doi-asserted-by":"publisher","first-page":"4374","DOI":"10.1038\/s41598-019-40758-5","volume":"9","author":"A Sabarudin","year":"2019","unstructured":"Sabarudin A, Siong TW, Chin AW, Hoong NK, Karim MKA. A comparison study of radiation effective dose in ECG-gated coronary CT angiography and calcium scoring examinations performed with a dual-source CT scanner. Sci Rep. 2019;9:4374. \nhttps:\/\/doi.org\/10.1038\/s41598-019-40758-5\n\n.","journal-title":"Sci Rep"},{"key":"532_CR4","doi-asserted-by":"publisher","first-page":"137","DOI":"10.12659\/PJR.890729","volume":"79","author":"P Bombi\u0144ski","year":"2014","unstructured":"Bombi\u0144ski P, Warcho\u0142 S, Brzewski M, Biejat A, Dudek-Warcho\u0142 T, Krzemie\u0144 G, et al. Lower-dose CT urography (CTU) with iterative reconstruction technique in children\u2014initial experience and examination protocol. Pol J Radiol. 2014;79:137\u201344. \nhttps:\/\/doi.org\/10.12659\/PJR.890729\n\n.","journal-title":"Pol J Radiol"},{"key":"532_CR5","doi-asserted-by":"publisher","first-page":"940","DOI":"10.1016\/j.jcmg.2009.02.015","volume":"2","author":"B Bischoff","year":"2009","unstructured":"Bischoff B, Hein F, Meyer T, Hadamitzky M, Martinoff S, Sch\u00f6mig A, et al. Impact of a reduced tube voltage on CT angiography and radiation dose: results of the PROTECTION I study. JACC Cardiovasc Imaging. 2009;2:940\u20136. \nhttps:\/\/doi.org\/10.1016\/j.jcmg.2009.02.015\n\n.","journal-title":"JACC Cardiovasc Imaging"},{"key":"532_CR6","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1093\/jicru\/ndt006","volume":"12","author":"JM Boone","year":"2012","unstructured":"Boone JM, Brink JA, Edyvean S, Huda W, Leitz W, McCollough CH, et al. Radiation dose and image-quality assessment in computed tomography. J ICRU. 2012;12:9\u2013149. \nhttps:\/\/doi.org\/10.1093\/jicru\/ndt006\n\n.","journal-title":"J ICRU"},{"key":"532_CR7","doi-asserted-by":"publisher","first-page":"012031","DOI":"10.1088\/1742-6596\/694\/1\/012031","volume":"694","author":"MKA Karim","year":"2016","unstructured":"Karim MKA, Hashim S, Bradley DA, Bahruddin NA, Ang WC, Salehhon N. Assessment of knowledge and awareness among radiology personnel regarding current computed tomography technology and radiation dose. J Phys Conf Ser. 2016;694:012031. \nhttps:\/\/doi.org\/10.1088\/1742-6596\/694\/1\/012031\n\n.","journal-title":"J Phys Conf Ser"},{"key":"532_CR8","first-page":"567","volume":"45","author":"MKA Karim","year":"2016","unstructured":"Karim MKA, Hashim S, Sabarudin A, Bradley DA, Bahruddin NA. Evaluating organ dose and radiation risk of routine CT examinations in Johor Malaysia. Sains Malays. 2016;45:567\u201373.","journal-title":"Sains Malays"},{"key":"532_CR9","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1016\/j.icrp.2012.06.004","volume":"41","author":"DJ Brenner","year":"2012","unstructured":"Brenner DJ. Minimising medically unwarranted computed tomography scans. Ann ICRP. 2012;41:161\u20139. \nhttps:\/\/doi.org\/10.1016\/j.icrp.2012.06.004\n\n.","journal-title":"Ann ICRP"},{"key":"532_CR10","doi-asserted-by":"publisher","first-page":"e982","DOI":"10.1016\/j.ejrad.2012.06.019","volume":"81","author":"MM Rehani","year":"2012","unstructured":"Rehani MM, Ciraj-Bjelac O, Al-Naemi HM, Al-Suwaidi JS, El-Nachef L, Khosravi HR, et al. Radiation protection of patients in diagnostic and interventional radiology in Asian countries: impact of an IAEA project. Eur J Radiol. 2012;81:e982\u20139. \nhttps:\/\/doi.org\/10.1016\/j.ejrad.2012.06.019\n\n.","journal-title":"Eur J Radiol"},{"key":"532_CR11","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/j.ejmp.2008.01.012","volume":"24","author":"WA Kalender","year":"2008","unstructured":"Kalender WA, Buchenau S, Deak P, Kellermeier M, Langner O, van Straten M, et al. Technical approaches to the optimisation of CT. Phys Med. 2008;24:71\u20139. \nhttps:\/\/doi.org\/10.1016\/j.ejmp.2008.01.012\n\n.","journal-title":"Phys Med"},{"key":"532_CR12","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1016\/j.radphyschem.2016.05.004","volume":"126","author":"S Hashim","year":"2016","unstructured":"Hashim S, Karim MKA, Bakar KA, Sabarudin A, Chin AW, Saripan MI, et al. Evaluation of organ doses and specific k effective dose of 64-slice CT thorax examination using an adult anthropomorphic phantom. Radiat Phys Chem. 2016;126:14\u201320. \nhttps:\/\/doi.org\/10.1016\/j.radphyschem.2016.05.004\n\n.","journal-title":"Radiat Phys Chem"},{"key":"532_CR13","doi-asserted-by":"publisher","first-page":"012014","DOI":"10.1088\/1742-6596\/1248\/1\/012014","volume":"1248","author":"Y Musa","year":"2019","unstructured":"Musa Y, Hashim S, Khalis Abdul Karim M. Direct and indirect entrance surface dose measurement in X-ray diagnostics using nanoDot OSL dosimeters. J Phys Conf Ser. 2019;1248:012014. \nhttps:\/\/doi.org\/10.1088\/1742-6596\/1248\/1\/012014\n\n.","journal-title":"J Phys Conf Ser"},{"key":"532_CR14","doi-asserted-by":"publisher","first-page":"139","DOI":"10.3233\/XST-180397","volume":"27","author":"MKA Karim","year":"2019","unstructured":"Karim MKA, Rahim NA, Matsubara K, Hashim S, Mhareb MHA, Musa Y. The effectiveness of bismuth breast shielding with protocol optimization in CT Thorax examination. J Xray Sci Technol. 2019;27:139\u201347. \nhttps:\/\/doi.org\/10.3233\/XST-180397\n\n.","journal-title":"J Xray Sci Technol"},{"key":"532_CR15","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1088\/0031-9155\/44\/1\/011","volume":"44","author":"C-M Ma","year":"1999","unstructured":"Ma C-M, Seuntjens JP. Mass-energy absorption coefficient and backscatter factor ratios for kilovoltage X-ray beams. Phys Med Biol. 1999;44:131\u201343.","journal-title":"Phys Med Biol"},{"key":"532_CR16","doi-asserted-by":"crossref","unstructured":"ICRP. Compendium of Dose Coefficients based on ICRP publication 60. ICRP Publication 119. Ann ICRP. 2012;41(Suppl.).","DOI":"10.1016\/j.icrp.2012.06.038"},{"key":"532_CR17","doi-asserted-by":"publisher","first-page":"1261","DOI":"10.1118\/1.3544350","volume":"38","author":"W Huda","year":"2011","unstructured":"Huda W, Magill D, He W. CT effective dose per dose length product using ICRP 103 weighting factors. Med Phys. 2011;38:1261. \nhttps:\/\/doi.org\/10.1118\/1.3544350\n\n.","journal-title":"Med Phys"},{"key":"532_CR18","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/j.ejmp.2012.06.008","volume":"28","author":"W Huda","year":"2012","unstructured":"Huda W. Computing patient specific effective doses and radiation risks in CT. Phys Med. 2012;28:333. \nhttps:\/\/doi.org\/10.1016\/j.ejmp.2012.06.008\n\n.","journal-title":"Phys Med"},{"key":"532_CR19","doi-asserted-by":"publisher","first-page":"210","DOI":"10.4329\/wjr.v6.i5.210","volume":"6","author":"S Pourjabbar","year":"2014","unstructured":"Pourjabbar S, Singh S, Padole A, Saini A, Blake MA, Kalra MK. Size-specific dose estimates: localizer or transverse abdominal computed tomography images? World J Radiol. 2014;6:210\u20137. \nhttps:\/\/doi.org\/10.4329\/wjr.v6.i5.210\n\n.","journal-title":"World J Radiol"},{"key":"532_CR20","unstructured":"Commission E. European guidelines on quality criteria for computed tomography. EUR 16262 EN. 1997."},{"key":"532_CR21","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.radphyschem.2015.12.020","volume":"121","author":"MKA Karim","year":"2016","unstructured":"Karim MKA, Hashim S, Bradley DA, Bakar KA, Haron MR, Kayun Z. Radiation doses from computed tomography practice in Johor Bahru, Malaysia. Radiat Phys Chem. 2016;121:69\u201374. \nhttps:\/\/doi.org\/10.1016\/j.radphyschem.2015.12.020\n\n.","journal-title":"Radiat Phys Chem"},{"key":"532_CR22","doi-asserted-by":"publisher","first-page":"1962","DOI":"10.1016\/j.ejrad.2014.06.016","volume":"83","author":"A Laqmani","year":"2014","unstructured":"Laqmani A, Regier M, Veldhoen S, Backhaus A, Wassenberg F, Sehner S, et al. Improved image quality and low radiation dose with hybrid iterative reconstruction with 80\u00a0kV CT pulmonary angiography. Eur J Radiol. 2014;83:1962\u20139. \nhttps:\/\/doi.org\/10.1016\/j.ejrad.2014.06.016\n\n.","journal-title":"Eur J Radiol"},{"key":"532_CR23","doi-asserted-by":"publisher","first-page":"397","DOI":"10.1016\/S1094-6950(06)60405-8","volume":"2","author":"R Patel","year":"1999","unstructured":"Patel R, Blake GM, Fogelman I. Radiation dose to the patient and operator from a peripheral dual X-ray absorptiometry system. J Clin Densitom. 1999;2:397\u2013401. \nhttps:\/\/doi.org\/10.1016\/S1094-6950(06)60405-8\n\n.","journal-title":"J Clin Densitom"},{"key":"532_CR24","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1148\/radiol.2302021489","volume":"230","author":"UJ Schoepf","year":"2004","unstructured":"Schoepf UJ, Costello P. CT angiography for diagnosis of pulmonary embolism: state of the art. Radiology. 2004;230:329\u201337. \nhttps:\/\/doi.org\/10.1148\/radiol.2302021489\n\n.","journal-title":"Radiology"},{"key":"532_CR25","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1016\/j.ejrad.2013.06.032","volume":"83","author":"JX Cao","year":"2014","unstructured":"Cao JX, Wang YM, Lu JG, Zhang Y, Wang P, Yang C. Radiation and contrast agent doses reductions by using 80-kV tube voltage in coronary computed tomographic angiography: a comparative study. Eur J Radiol. 2014;83:309\u201314. \nhttps:\/\/doi.org\/10.1016\/j.ejrad.2013.06.032\n\n.","journal-title":"Eur J Radiol"},{"key":"532_CR26","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1120\/jacmp.v16i1.5135","volume":"16","author":"A Sabarudin","year":"2015","unstructured":"Sabarudin A, Mustafa Z, Nassir KM, Hamid HA, Sun Z. Radiation dose reduction in thoracic and abdomen\u2013pelvic CT using tube current modulation: a phantom study. J Appl Clin Med Phys. 2015;16:319\u201328.","journal-title":"J Appl Clin Med Phys"}],"container-title":["Radiological Physics and Technology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-019-00532-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s12194-019-00532-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-019-00532-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,8,28]],"date-time":"2020-08-28T00:00:04Z","timestamp":1598572804000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s12194-019-00532-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8,29]]},"references-count":26,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["532"],"URL":"https:\/\/doi.org\/10.1007\/s12194-019-00532-8","relation":{},"ISSN":["1865-0333","1865-0341"],"issn-type":[{"type":"print","value":"1865-0333"},{"type":"electronic","value":"1865-0341"}],"subject":[],"published":{"date-parts":[[2019,8,29]]},"assertion":[{"value":"18 February 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 August 2019","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 August 2019","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 August 2019","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The research protocols were approved by the institution\u2019s research ethical committee with ethical number UKMPPI\/111\/8\/JEP-2018-012.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}