{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,24]],"date-time":"2025-08-24T01:33:11Z","timestamp":1755999191470,"version":"3.37.3"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,12,12]],"date-time":"2019-12-12T00:00:00Z","timestamp":1576108800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,12,12]],"date-time":"2019-12-12T00:00:00Z","timestamp":1576108800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol Phys Technol"],"published-print":{"date-parts":[[2020,3]]},"DOI":"10.1007\/s12194-019-00548-0","type":"journal-article","created":{"date-parts":[[2020,2,21]],"date-time":"2020-02-21T16:02:51Z","timestamp":1582300971000},"page":"98-103","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Time-related study on external exposure dose of 2-deoxy-2-[F-18]fluoro-d-glucose PET for workers\u2019 safety"],"prefix":"10.1007","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2504-2720","authenticated-orcid":false,"given":"Yasuyuki","family":"Takahashi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shota","family":"Hosokawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takakiyo","family":"Tsujiguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoru","family":"Monzen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takao","family":"Kanzaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koji","family":"Shirakawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ayaka","family":"Nemoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hayato","family":"Ishimura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Noboru","family":"Oriuchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,12,12]]},"reference":[{"key":"548_CR1","first-page":"1051","volume":"41","author":"CL Melcher","year":"2000","unstructured":"Melcher CL. Scintillation crystals for PET. J Nucl Med. 2000;41:1051\u20135.","journal-title":"J Nucl Med."},{"key":"548_CR2","first-page":"23","volume":"47","author":"MA Lodge","year":"2006","unstructured":"Lodge MA, Badawi RD, Gilbert R, Dibos PE, Line BR. Comparison of 2-dimensional and 3-dimensional acquisition for 18F-FDG PET oncology studies performed on an LSO-based scanner. J Nucl Med. 2006;47:23\u201331.","journal-title":"J Nucl Med."},{"key":"548_CR3","doi-asserted-by":"publisher","first-page":"1380","DOI":"10.1007\/s002590050164","volume":"24","author":"C Chiesa","year":"1997","unstructured":"Chiesa C, De Sanctis V, Crippa F, Schiavini M, Fraigola CE, Bogni A, et al. Radiation dose to technicians per nuclear medicine procedure: comparison between technetium-99m, gallium-67, and iodine-131 radiotracers and fluorine-18 fluorodeoxyglucose. Eur J Nucl Med. 1997;24:1380\u20139.","journal-title":"Eur J Nucl Med."},{"key":"548_CR4","doi-asserted-by":"publisher","first-page":"55","DOI":"10.2967\/jnmt.110.080358","volume":"39","author":"T Bayram","year":"2011","unstructured":"Bayram T, Yilmaz AH, Demir M, Sonmez B. Radiation dose to technologists per nuclear medicine examination and estimation of annual dose. J Nucl Med Technol. 2011;39:55\u20139.","journal-title":"J Nucl Med Technol."},{"key":"548_CR5","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1097\/00006231-199001000-00004","volume":"11","author":"LK Harding","year":"1990","unstructured":"Harding LK, Harding NJ, Warren H, Mills A, Thomson WH. The radiation dose to accompanying nurses, relatives and other patients in a nuclear medicine department waiting room. Nucl Med comm. 1990;11:17\u201322.","journal-title":"Nucl Med comm."},{"key":"548_CR6","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1007\/s002590050546","volume":"27","author":"NA Benatar","year":"2000","unstructured":"Benatar NA, Cronin BF, O\u2019Doherty MJ. Radiation dose rates from patients undergoing PET: implications for technologists and waiting areas. Eur J Nucl Med Mol Imaging. 2000;27:583\u20139.","journal-title":"Eur J Nucl Med Mol Imaging."},{"key":"548_CR7","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1093\/rpd\/ncq110","volume":"140","author":"P Covens","year":"2010","unstructured":"Covens P, Berus D, Vanhavere F, Caveliers V. The introduction of automated dispensing and injection during PET procedures: a step in optimisation of extremity doses and whole-body doses of nuclear medicine staff. Radiat Prot Dosimetry. 2010;140:250\u20138.","journal-title":"Radiat Prot Dosimetry."},{"key":"548_CR8","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1093\/oxfordjournals.rpd.a005933","volume":"100","author":"H Yasuda","year":"2002","unstructured":"Yasuda H, Fujitaka K. Efficiency of a radiophotoluminescence glass dosemeter for low-earth-orbit space radiation. Radiat Prot Dosimetry. 2002;100:545\u20138.","journal-title":"Radiat Prot Dosimetry."},{"key":"548_CR9","first-page":"1","volume":"49","author":"A Suzuki","year":"2014","unstructured":"Suzuki A, Suzuki T, Takahashi M, Nakata T, Murayama T, Tsunoda M. Characteristics of OSL dosimeter for individual monitoring for external radiation. JAEA-Technology. 2014;49:1\u20138 (In Japanese).","journal-title":"JAEA-Technology."},{"key":"548_CR10","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1016\/j.radmeas.2017.03.011","volume":"106","author":"Z Cemusova","year":"2017","unstructured":"Cemusova Z, Ekendahl D, Judas L. Testing of the D-Shuttle personal dosemeter. Radiat Meas. 2017;106:214\u20137.","journal-title":"Radiat Meas."},{"key":"548_CR11","first-page":"21","volume":"3","author":"Y Yamaguchi","year":"2004","unstructured":"Yamaguchi Y, Saito T. Secular and angular response changes of semiconductor-type electronic pocket dosimeter. Jpn J Radiat Magag. 2004;3:21\u20136 (In Japanese).","journal-title":"Jpn J Radiat Magag."},{"key":"548_CR12","doi-asserted-by":"publisher","first-page":"1105","DOI":"10.6009\/jjrt.62.1105","volume":"62","author":"F Nakamura","year":"2006","unstructured":"Nakamura F, Kanno T, Okada H, Yoshikawa E, Andou I, Futatsubashi M, et al. Measurement of radiation exposure to a PET institution driver from patients injected with FDG. Jpn J Radiol Technol. 2006;62:1105\u201310 (In Japanese).","journal-title":"Jpn J Radiol Technol."},{"key":"548_CR13","doi-asserted-by":"publisher","DOI":"10.1093\/rpd\/ncz107","author":"T Tsujiguchi","year":"2019","unstructured":"Tsujiguchi T, Shiroma Y, Suzuki T, Tamakuma Y, Yamaguchi M, Iwaoka K, et al. Investigation of external radiation doses during residents' temporal stay to Namie town, Fukushima prefecture. Radiat Prot Dosimetry. 2019. https:\/\/doi.org\/10.1093\/rpd\/ncz107.","journal-title":"Radiat Prot Dosimetry."},{"key":"548_CR14","doi-asserted-by":"publisher","first-page":"452","DOI":"10.3769\/radioisotopes.67.453","volume":"67","author":"K Murayama","year":"2018","unstructured":"Murayama K. Outline of D-Shuttle and its application. Radioisotopes. 2018;67:452\u201360.","journal-title":"Radioisotopes"},{"key":"548_CR15","first-page":"33","volume":"2","author":"S Deji","year":"2003","unstructured":"Deji S, Nishizawa K. Effects of high frequency electromagnetic fields emitted from digital cellular telephones on electronic pocket dosimeters. Jpn J Radiat Magag. 2003;2:33\u20137 (In Japanese).","journal-title":"Jpn J Radiat Magag."},{"key":"548_CR16","first-page":"2","volume":"37","author":"ICRP Publication 103","year":"2007","unstructured":"ICRP Publication 103. The 2007 recommendations of the International Commission on radiological protection. Ann ICRP. 2007;37:2\u20134.","journal-title":"Ann ICRP"},{"key":"548_CR17","unstructured":"Levinger R, Budinger TF, Watson EE. 1991. MIRD primer for absorbed dose calculations: Revised. New York: The Society of Nuclear Medicine, pdf. Accessed 17 Oct 2019."},{"key":"548_CR18","first-page":"65","volume":"21","author":"K Choju","year":"2006","unstructured":"Choju K. Gamma-ray shielding lead glass for PET facilities \u201cPro-GR\u201d. New Glass. 2006;21:65\u20139 (In Japanese).","journal-title":"New Glass."},{"key":"548_CR19","unstructured":"International Atomic Energy Agency. Occupational radiation protection: general safety guide. IAEA safety standards series No.GSG-7. Vienna: International Atomic Energy Agency; 2018. https:\/\/www-pub.iaea.org\/MTCD\/Publications\/PDF\/PUB1785_web.pdf."}],"container-title":["Radiological Physics and Technology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-019-00548-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s12194-019-00548-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-019-00548-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,12,11]],"date-time":"2020-12-11T01:24:03Z","timestamp":1607649843000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s12194-019-00548-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,12]]},"references-count":19,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,3]]}},"alternative-id":["548"],"URL":"https:\/\/doi.org\/10.1007\/s12194-019-00548-0","relation":{},"ISSN":["1865-0333","1865-0341"],"issn-type":[{"type":"print","value":"1865-0333"},{"type":"electronic","value":"1865-0341"}],"subject":[],"published":{"date-parts":[[2019,12,12]]},"assertion":[{"value":"12 June 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 November 2019","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 November 2019","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 December 2019","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures in the study involving human participants were in accordance with the ethical standards of the institution research committee and with the 1964 Declaration of Helsinki and its later amendments or comparable ethical standards. For this type of study, formal consent was not required.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statement of human rights"}},{"value":"This article does not contain any studies with animals performed by any of the authors.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statement of animal rights"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}