{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T14:33:22Z","timestamp":1740148402709,"version":"3.37.3"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,12,12]],"date-time":"2022-12-12T00:00:00Z","timestamp":1670803200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2022,12,12]],"date-time":"2022-12-12T00:00:00Z","timestamp":1670803200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100000646","name":"Japan Society for the Promotion of Science London","doi-asserted-by":"publisher","award":["19K12327"],"award-info":[{"award-number":["19K12327"]}],"id":[{"id":"10.13039\/501100000646","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Tochigi New Industry & HR Development Consortium"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol Phys Technol"],"published-print":{"date-parts":[[2023,3]]},"DOI":"10.1007\/s12194-022-00691-1","type":"journal-article","created":{"date-parts":[[2022,12,12]],"date-time":"2022-12-12T09:03:21Z","timestamp":1670835801000},"page":"69-76","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Characteristics of a real-time radiation exposure dosimetry system using a synthetic ruby for radiotherapy"],"prefix":"10.1007","volume":"16","author":[{"given":"Kenki","family":"Matsumoto","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ayaka","family":"Maruyama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoru","family":"Watanabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryousuke","family":"Tachibana","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshiya","family":"Yamaguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kouki","family":"Suzuki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshiki","family":"Kurihara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masayoshi","family":"Maehara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoshi","family":"Arakawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5320-1074","authenticated-orcid":false,"given":"Yoshiyuki","family":"Hosokai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,12,12]]},"reference":[{"issue":"3","key":"691_CR1","doi-asserted-by":"publisher","first-page":"e73","DOI":"10.1016\/j.prro.2015.10.004","volume":"6","author":"JM Kilburn","year":"2016","unstructured":"Kilburn JM, Soike MH, Lucas JT, et al. Image guided radiation therapy may result in improved local control in locally advanced lung cancer patients. Pract Radiat Oncol. 2016;6(3):e73-80.","journal-title":"Pract Radiat Oncol"},{"key":"691_CR2","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1186\/1748-717X-9-44","volume":"9","author":"S Joen","year":"2014","unstructured":"Joen S, Rosensch\u00f6ld PM, Deasy JO, et al. Improvement in toxicity in high risk prostate cancer patients treated with image-guided intensity-modulated radiotherapy compared to 3D conformal radiotherapy without daily image guidance. Radiat Oncol. 2014;9:44.","journal-title":"Radiat Oncol"},{"issue":"5","key":"691_CR3","doi-asserted-by":"publisher","first-page":"1078","DOI":"10.1016\/j.ijrobp.2012.02.015","volume":"84","author":"SH Lin","year":"2012","unstructured":"Lin SH, Wang L, Myles B, et al. Propensity score-based comparison of long-term outcomes with 3-dimensional conformal radiotherapy vs intensity-modulated radiotherapy for esophageal cancer. Int J Radiat Oncol Biol Phys. 2012;84(5):1078\u201385.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"691_CR4","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1016\/j.radonc.2008.08.008","volume":"89","author":"L Fenkell","year":"2009","unstructured":"Fenkell L, Kaminsky I, Breen S, et al. Dosimetric comparison of IMRT vs 3D conformal radiotherapy in the treatment of cancer of the cervical esophagus. Radiother Oncol. 2009;89:287\u201391.","journal-title":"Radiother Oncol"},{"key":"691_CR5","doi-asserted-by":"publisher","first-page":"4158","DOI":"10.1002\/cncr.30856","volume":"123","author":"SW de Geus","year":"2017","unstructured":"de Geus SW, Eskander MF, Kasumova GG, et al. Stereotactic body radiotherapy for unresected pancreatic cancer: a nationwide review. Cancer. 2017;123:4158\u201367.","journal-title":"Cancer"},{"key":"691_CR6","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1016\/j.radonc.2006.02.009","volume":"78","author":"C Fiorino","year":"2006","unstructured":"Fiorino C, Dell\u2019Oca I, Pierelli A, et al. Significant improvement in normal tissue sparing and target coverage for head and neck cancer by means of helical tomotherapy. Radiother Oncol. 2006;78:276\u201382.","journal-title":"Radiother Oncol"},{"key":"691_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.compmedimag.2016.10.001","volume":"54","author":"H Liu","year":"2016","unstructured":"Liu H, Chen X, He Z, et al. Evaluation of 3D-CRT, IMRT and VMAT radiotherapy plans for left breast cancer based on clinical dosimetric study. Comput Med Imag Grap. 2016;54:1\u20135.","journal-title":"Comput Med Imag Grap"},{"key":"691_CR8","first-page":"2","volume":"1","author":"CR Hansen","year":"2016","unstructured":"Hansen CR, Bertelsen A, Hazell I, et al. Automatic treatment planning improves the clinical quality of head and neck cancer treatment plans. Clin Transl Rad Oncol. 2016;1:2\u20138.","journal-title":"Clin Transl Rad Oncol"},{"key":"691_CR9","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1016\/j.ejmp.2017.04.003","volume":"44","author":"CH Clark","year":"2017","unstructured":"Clark CH, Hurkmans CW, Kry SF, et al. The role of dosimetry audit in lung SBRT multi-centre clinical trials. Phys Medica. 2017;44:171\u20136.","journal-title":"Phys Medica"},{"issue":"3","key":"691_CR10","doi-asserted-by":"publisher","first-page":"1313","DOI":"10.1118\/1.3514120","volume":"38","author":"DA Low","year":"2011","unstructured":"Low DA, Moran JM, Dempsey JF, et al. Dosimetry tools and techniques for IMRT. Med Phys. 2011;38(3):1313\u201338.","journal-title":"Med Phys"},{"key":"691_CR11","doi-asserted-by":"publisher","first-page":"20150251","DOI":"10.1259\/bjr.20150251","volume":"88","author":"CH Clark","year":"2015","unstructured":"Clark CH, Aird EG, Bolton S, et al. Radiotherapy dosimetry audit: three decades of improving standards and accuracy in UK clinical practice and trials. Br J Radiol. 2015;88:20150251.","journal-title":"Br J Radiol"},{"key":"691_CR12","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1186\/1748-717X-9-71","volume":"9","author":"H Lin","year":"2014","unstructured":"Lin H, Huang S, Deng X, et al. Comparison of 3D anatomical dose verification and 2D phantom dose verification of IMRT\/VMAT treatments for nasopharyngeal carcinoma. Radiat Oncol. 2014;9:71.","journal-title":"Radiat Oncol"},{"key":"691_CR13","doi-asserted-by":"publisher","first-page":"2996","DOI":"10.1200\/JCO.2009.27.4498","volume":"28","author":"LJ Peters","year":"2010","unstructured":"Peters LJ, O\u2019Sullivan B, Giralt J, et al. Critical impact of radiotherapy protocol compliance and quality in the treatment of advanced head and neck cancer: results from TROG 02.02. J Clin Oncol. 2010;28:2996\u20133001.","journal-title":"J Clin Oncol"},{"key":"691_CR14","volume-title":"Investigation of an accidental exposure of radiotherapy patients in Panama","author":"International Atomic Energy Agency","year":"2001","unstructured":"International Atomic Energy Agency. Investigation of an accidental exposure of radiotherapy patients in Panama. Vienna: IAEA; 2001."},{"key":"691_CR15","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1016\/S0936-6555(05)80290-0","volume":"6","author":"D Ash","year":"1994","unstructured":"Ash D, Bates T. Report on the clinical effects of inadvertent radiation underdosage in 1045 patients. Clin Oncol. 1994;6:214\u201325.","journal-title":"Clin Oncol"},{"key":"691_CR16","volume-title":"accidental overexposure of radiotherapy patients in Bia\u0142ystok","author":"International Atomic Energy Agency","year":"2006","unstructured":"International Atomic Energy Agency. accidental overexposure of radiotherapy patients in Bia\u0142ystok. Vienna: IAEA; 2006."},{"key":"691_CR17","volume-title":"The accident of the linear accelerator in the \u201cHospital Cl\u00ednico de Zaragoza\u201d","author":"Sociedad Espa\u00f1ola De F\u00edsica M\u00e9dica","year":"1991","unstructured":"Sociedad Espa\u00f1ola De F\u00edsica M\u00e9dica. The accident of the linear accelerator in the \u201cHospital Cl\u00ednico de Zaragoza.\u201d Madrid: SEFM; 1991."},{"issue":"4","key":"691_CR18","doi-asserted-by":"publisher","first-page":"1546","DOI":"10.1088\/0031-9155\/61\/4\/1546","volume":"61","author":"MF Fast","year":"2016","unstructured":"Fast MF, Kamerling CP, Ziegenhein P, et al. Assessment of MLC tracking performance during hypofractionated prostate radiotherapy using real-time dose reconstruction. Phys Med Biol. 2016;61(4):1546\u201362.","journal-title":"Phys Med Biol"},{"issue":"3","key":"691_CR19","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1120\/jacmp.v9i3.2800","volume":"9","author":"S Senthilkumar","year":"2008","unstructured":"Senthilkumar S, Ramakrishnan V. In-house auto cutoff sensor device for radiotherapy machine to monitor patient movements. J Appl Clin Med Phys. 2008;9(3):82\u20139.","journal-title":"J Appl Clin Med Phys"},{"issue":"4","key":"691_CR20","doi-asserted-by":"publisher","first-page":"534","DOI":"10.3390\/s16040534","volume":"16","author":"M Ostyn","year":"2016","unstructured":"Ostyn M, Kim S, Yeo WH. A simulation study of a radiofrequency localization system for tracking patient motion in radiotherapy. Sensors. 2016;16(4):534.","journal-title":"Sensors"},{"issue":"4","key":"691_CR21","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1093\/rpd\/ncw381","volume":"175","author":"Y Hosokai","year":"2017","unstructured":"Hosokai Y, Matsumoto K, Kozakai M, et al. Development of real-time radiation exposure dosimetry system using synthetic ruby for interventional radiology. Radiat Prot Dosim. 2017;175(4):517\u201322.","journal-title":"Radiat Prot Dosim"},{"key":"691_CR22","doi-asserted-by":"publisher","first-page":"1847","DOI":"10.1118\/1.598691","volume":"26","author":"PR Almond","year":"1999","unstructured":"Almond PR, Biggs PJ, Coursey BM, et al. AAPM\u2019s TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams. Med Phys. 1999;26:1847\u201370.","journal-title":"Med Phys"},{"key":"691_CR23","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1016\/j.radmeas.2017.04.017","volume":"106","author":"PE Wesolowska","year":"2017","unstructured":"Wesolowska PE, Cole A, Santos T, et al. Characterization of three solid state dosimetry systems for use in high energy photon dosimetry audits in radiotherapy. Radiat Meas. 2017;106:556\u201362.","journal-title":"Radiat Meas"},{"issue":"5","key":"691_CR24","doi-asserted-by":"publisher","first-page":"569","DOI":"10.2109\/jcersj2.15239","volume":"124","author":"M Mori","year":"2016","unstructured":"Mori M, Xu J, Okada G, et al. Comparative study of optical and scintillation properties of Ce:YAGG, Ce:GAGG and Ce:LuAGG transparent ceramics. J Ceram Soc Japan. 2016;124(5):569\u201373.","journal-title":"J Ceram Soc Japan"},{"key":"691_CR25","doi-asserted-by":"publisher","first-page":"75","DOI":"10.2183\/pjab.94.007","volume":"94","author":"T Yanagida","year":"2018","unstructured":"Yanagida T. Inorganic scintillating materials and scintillation detectors. Proc Jpn Acad Ser B Phys Biol Sci. 2018;94:75\u201397.","journal-title":"Proc Jpn Acad Ser B Phys Biol Sci"},{"key":"691_CR26","doi-asserted-by":"publisher","first-page":"4827","DOI":"10.1021\/cg501005s","volume":"14","author":"M Nikl","year":"2014","unstructured":"Nikl M, Kamada K, Babin V, et al. Defect engineering in Ce-doped aluminum garnet single crystal scintillators. Cryst Growth Des. 2014;14:4827\u201333.","journal-title":"Cryst Growth Des"},{"issue":"1","key":"691_CR27","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1007\/s13246-018-0622-2","volume":"41","author":"LK Webb","year":"2018","unstructured":"Webb LK, Inness EK, Charles PH. A comparative study of three small-field detectors for patient specific stereotactic arc dosimetry. Australas Phys Eng Sci Med. 2018;41(1):217\u201323.","journal-title":"Australas Phys Eng Sci Med"},{"issue":"7","key":"691_CR28","doi-asserted-by":"publisher","first-page":"3815","DOI":"10.1002\/mp.12272","volume":"44","author":"J Xue","year":"2017","unstructured":"Xue J, McKay JD, Grimm J, et al. Small field dose measurements using plastic scintillation detector in heterogeneous media. Med Phys. 2017;44(7):3815\u201320.","journal-title":"Med Phys"},{"issue":"1","key":"691_CR29","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1118\/1.4903757","volume":"42","author":"P Carrasco","year":"2015","unstructured":"Carrasco P, Jornet N, Jordi O, et al. Characterization of the Exradin W1 scintillator for use in radiotherapy. Med Phys. 2015;42(1):297\u2013304.","journal-title":"Med Phys"},{"key":"691_CR30","volume":"95","author":"J Caravaca","year":"2017","unstructured":"Caravaca J, Descamps FB, Land BJ, et al. Experiment to demonstrate separation of Cherenkov and scintillation signals. Phys Rev. 2017;95: 055801.","journal-title":"Phys Rev"},{"key":"691_CR31","doi-asserted-by":"publisher","DOI":"10.1088\/2399-6528\/aaca28","volume":"2","author":"S Yamamoto","year":"2018","unstructured":"Yamamoto S, Akagi T, Yamashita T, et al. Source of luminescence of water lower energy than the Cerenkov-light threshold during irradiation of carbon-ion. J Phys Commun. 2018;2: 065010.","journal-title":"J Phys Commun"},{"key":"691_CR32","doi-asserted-by":"publisher","first-page":"239","DOI":"10.3390\/chemosensors9090239","volume":"9","author":"S Min","year":"2021","unstructured":"Min S, Kim Y, Ko K, et al. Optimization of plastic scintillator for detection of gamma-rays: simulation and experimental study. Chemosensors. 2021;9:239.","journal-title":"Chemosensors"},{"key":"691_CR33","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1093\/ndt\/gfl621","volume":"22","author":"ND Toussaint","year":"2007","unstructured":"Toussaint ND, Lau KK, Polkinghorne KR, et al. Measurement of vascular calcification using CT fistulograms. Nephrol Dial Transplant. 2007;22:484\u201390.","journal-title":"Nephrol Dial Transplant"}],"container-title":["Radiological Physics and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-022-00691-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12194-022-00691-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-022-00691-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,2,27]],"date-time":"2023-02-27T15:41:05Z","timestamp":1677512465000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12194-022-00691-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,12]]},"references-count":33,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2023,3]]}},"alternative-id":["691"],"URL":"https:\/\/doi.org\/10.1007\/s12194-022-00691-1","relation":{},"ISSN":["1865-0333","1865-0341"],"issn-type":[{"type":"print","value":"1865-0333"},{"type":"electronic","value":"1865-0341"}],"subject":[],"published":{"date-parts":[[2022,12,12]]},"assertion":[{"value":"16 September 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 December 2022","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 December 2022","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 December 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This work was supported by JSPS KAKENHI (grant number 19K12327) and the Tochigi New Industry & HR Development Consortium.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This was a phantom study; therefore, it did not require informed consent or ethical approval.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}