{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T05:06:57Z","timestamp":1789016817269,"version":"build-2803163510"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2023,10,9]],"date-time":"2023-10-09T00:00:00Z","timestamp":1696809600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,10,9]],"date-time":"2023-10-09T00:00:00Z","timestamp":1696809600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol Phys Technol"],"published-print":{"date-parts":[[2023,12]]},"DOI":"10.1007\/s12194-023-00741-2","type":"journal-article","created":{"date-parts":[[2023,10,9]],"date-time":"2023-10-09T11:04:12Z","timestamp":1696849452000},"page":"532-542","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Characteristics of detection accuracy of the patient setup using InBore optical patient positioning system"],"prefix":"10.1007","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3359-0639","authenticated-orcid":false,"given":"Yoshifumi","family":"Oku","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masahiko","family":"Toyota","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasumasa","family":"Saigo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,10,9]]},"reference":[{"key":"741_CR1","doi-asserted-by":"publisher","first-page":"e82","DOI":"10.1002\/mp.15532","volume":"49","author":"HA Al-Hallaq","year":"2022","unstructured":"Al-Hallaq HA, Cervi\u00f1o L, Gutierrez AN, Havnen-Smith A, Higgins SA, K\u00fcgele M, et al. AAPM task group report 302: surface guided radiotherapy. Med Phys. 2022;49:e82-112.","journal-title":"Med Phys"},{"key":"741_CR2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s13014-019-1449-z","volume":"15","author":"P Freislederer","year":"2020","unstructured":"Freislederer P, K\u00fcgele M, \u00d6llers M, Swinnen A, Sauer TO, Bert C, et al. Recent advances in surface-guided radiation therapy. Radiat Oncol Radiat Oncol. 2020;15:1\u201311.","journal-title":"Radiat Oncol Radiat Oncol"},{"issue":"5","key":"741_CR3","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1002\/acm2.12852","volume":"21","author":"JH Heinzerling","year":"2020","unstructured":"Heinzerling JH, Hampton CJ, Robinson M, Bright M, Moeller BJ, et al. Use of surface-guided radiation therapy in combination with IGRT for setup and intrafraction motion monitoring during stereotactic body radiation therapy treatments of the lung and abdomen. J Appl Clin Med Phys. 2020;21(5):48\u201355.","journal-title":"J Appl Clin Med Phys"},{"key":"741_CR4","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1186\/s13014-019-1329-6","volume":"14","author":"VC Hamming","year":"2019","unstructured":"Hamming VC, Visser C, Batin E, McDermott LN, Busz DM, Both S, et al. Evaluation of a 3D surface imaging system for deep inspiration breath-hold patient positioning and intra-fraction monitoring. Radiat Oncol. 2019;14:125.","journal-title":"Radiat Oncol"},{"issue":"1","key":"741_CR5","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1002\/acm2.12498","volume":"20","author":"D Wiant","year":"2019","unstructured":"Wiant D, Liu H, Hayes TL, Shang Q, Mutic S, Sintay B. Direct comparison between surface imaging and orthogonal radiographic imaging for SRS localization in phantom. J Appl Clin Med Phys. 2019;20(1):137\u201344.","journal-title":"J Appl Clin Med Phys"},{"issue":"1","key":"741_CR6","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/j.rpor.2017.12.007","volume":"23","author":"A Cravo S\u00e1","year":"2018","unstructured":"Cravo S\u00e1 A, Fermento A, Neves D, Ferreira S, Silva T, Coelho CM, et al. Radiotherapy setup displacements in breast cancer patients: 3D surface imaging experience. Rep Pract Oncol Radiother. 2018;23(1):61\u20137.","journal-title":"Rep Pract Oncol Radiother"},{"key":"741_CR7","doi-asserted-by":"crossref","unstructured":"Alderliesten T, Sonke JJ, Betgen A, Honnef J, Vroegindeweij V, Remeijer P. Accuracy evaluation of a 3-dimensional surface imaging system for guidance in deep-inspiration breath-hold radiation therapy. Int J Radiat Oncol Biol Phys. 2013;85:536\u2013542.","DOI":"10.1016\/j.ijrobp.2012.04.004"},{"issue":"2","key":"741_CR8","doi-asserted-by":"publisher","DOI":"10.1016\/j.adro.2022.101105","volume":"8","author":"A Qubala","year":"2023","unstructured":"Qubala A, Schwahofer A, Jersemann S, Eskandarian S, Harrabi S, Naumann P. Optimizing the patient positioning workflow of patients with pelvis, limb, and chest\/spine tumors at an ion-beam gantry based on optical surface guidance. Adv Radiat Oncol. 2023;8(2): 101105.","journal-title":"Adv Radiat Oncol"},{"issue":"6","key":"741_CR9","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1002\/acm2.12183","volume":"18","author":"DN Stanley","year":"2017","unstructured":"Stanley DN, McConnell KA, Kirby N, Gutierrez AN, Papanikolaou N, Rasmussen K. Comparison of initial patient setup accuracy between surface imaging and three point localization: a retrospective analysis. J Appl Clin Med Phys. 2017;18(6):58\u201361.","journal-title":"J Appl Clin Med Phys"},{"key":"741_CR10","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/j.ejmp.2020.10.024","volume":"80","author":"D Nguyen","year":"2020","unstructured":"Nguyen D, Farah J, Barbet N, Khodri M. Commissioning and performance testing of the first prototype of AlignRT InBore\u2122 a Halcyon\u2122 and Ethos\u2122-dedicated surface guided radiation therapy platform. Physica Med. 2020;80:159\u201366.","journal-title":"Physica Med"},{"issue":"1","key":"741_CR11","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1002\/acm2.12772","volume":"21","author":"E Flores-Martinez","year":"2020","unstructured":"Flores-Martinez E, Cervi\u00f1o L, Pawlicki T, Kim G-Y. Assessment of the use of different imaging and delivery techniques for cranial treatments on the Halcyon\u2122 linac. J Appl Clin Med Phys. 2020;21(1):53\u201361.","journal-title":"J Appl Clin Med Phys"},{"key":"741_CR12","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2023.102567","volume":"108","author":"D Nguyen","year":"2023","unstructured":"Nguyen D, Khodri M, Sporea C, Reinoso R, Jacob Y, Farah J. Investigating the robustness of the AlignRT InBore\u2122 co-calibration process and determining the overall tracking errors. Physica Med. 2023;108: 102567.","journal-title":"Physica Med"},{"key":"741_CR13","first-page":"90","volume":"35","author":"F Lorchel","year":"2022","unstructured":"Lorchel F, Nguyen D, Mamou A, Barbet N, Camoesas J, Degluaire Y, et al. Reproducibility of Deep-Inspiration Breath Hold treatments on Halcyon\u2122 performed using the first clinical version of AlignRT InBore\u2122: Results of CYBORE study. Clin Transl Radiat Oncol. 2022;35:90\u20136.","journal-title":"Clin Transl Radiat Oncol"},{"key":"741_CR14","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13961","volume":"24","author":"DN Stanley","year":"2023","unstructured":"Stanley DN, Harms J, Pogue JA, Belliveau JG, Marcrom SR, McDonald AM, et al. A roadmap for implementation of kV-CBCT online adaptive radiation therapy and initial first year experiences. J Appl Clin Med Phys. 2023;24: e13961.","journal-title":"J Appl Clin Med Phys"},{"issue":"4","key":"741_CR15","doi-asserted-by":"publisher","first-page":"1728","DOI":"10.1118\/1.3681967","volume":"39","author":"T Willoughby","year":"2012","unstructured":"Willoughby T, Lehmann J, Bencomo JA, Jani SK, Santanam L, Sethi A, et al. AAPM task group report 147: Quality assurance for nonradiographic radiotherapy localization and positioning systems. Med Phys. 2012;39(4):1728\u201347.","journal-title":"Med Phys"},{"key":"741_CR16","doi-asserted-by":"publisher","first-page":"2753","DOI":"10.1118\/1.1984263","volume":"32","author":"C Bert","year":"2005","unstructured":"Bert C, Metheany KG, Doppke K, George T, Chen Y. A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup. Med Phys. 2005;32:2753\u201362.","journal-title":"Med Phys"},{"issue":"1","key":"741_CR17","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1186\/s13014-016-0728-1","volume":"11","author":"F Walter","year":"2016","unstructured":"Walter F, Freislederer P, Belka C, Heinz C, Roeder F. Evaluation of daily patient positioning for radiotherapy with a commercial 3D surface-imaging system (catalyst). Radiat Oncol. 2016;11(1):154.","journal-title":"Radiat Oncol"},{"key":"741_CR18","doi-asserted-by":"publisher","first-page":"153303381880600","DOI":"10.1177\/1533033818806002","volume":"17","author":"G Carl","year":"2018","unstructured":"Carl G, Reitz D, Schonecker S, Pazos M, Freislederer P, Reiner M, et al. Optical surface scanning for patient positioning in radiation therapy: a prospective analysis of 1902 fractions. Technol Cancer Res Treat. 2018;17:1533033818806002.","journal-title":"Technol Cancer Res Treat"},{"issue":"3","key":"741_CR19","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1093\/jrr\/rrac015","volume":"63","author":"S Masahide","year":"2022","unstructured":"Masahide S, Koji U, Suzuki H, Komiyama T, Kan M, Shinichi A, et al. Evaluation of the detection accuracy of set-up for various treatment sites using surface-guided radiotherapy system, VOXELAN: a phantom study. J Radiat Res. 2022;63(3):435\u201342.","journal-title":"J Radiat Res"},{"key":"741_CR20","doi-asserted-by":"crossref","unstructured":"Covington EL, Stanley DN, Sullivan RJ, Riley KO, Fiveash JB, Popple RA. Commissioning and clinical evaluation of the IDENTIFYTM surface imaging system for frameless stereotactic radiosurgery. J Appl Clin Med Phys. 2023; 1:e14058.","DOI":"10.1002\/acm2.14058"},{"key":"741_CR21","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab205a","volume":"64","author":"G Barfield","year":"2019","unstructured":"Barfield G, Burton EW, Stoddart J, Metwaly M, Cawley MG. Quality assurance of gating response times for surface guided motion management treatment delivery using an electronic portal imaging detector. Phys Med Biol. 2019;64: 125023.","journal-title":"Phys Med Biol"}],"container-title":["Radiological Physics and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-023-00741-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12194-023-00741-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-023-00741-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,22]],"date-time":"2023-11-22T16:22:03Z","timestamp":1700670123000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12194-023-00741-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,9]]},"references-count":21,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2023,12]]}},"alternative-id":["741"],"URL":"https:\/\/doi.org\/10.1007\/s12194-023-00741-2","relation":{},"ISSN":["1865-0333","1865-0341"],"issn-type":[{"value":"1865-0333","type":"print"},{"value":"1865-0341","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,10,9]]},"assertion":[{"value":"16 June 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 August 2023","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 September 2023","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 October 2023","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no conflicts of interest to declare in relation to this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was approved by the ethics committee of our institution.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}]}}