{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T14:33:26Z","timestamp":1740148406419,"version":"3.37.3"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2023,10,6]],"date-time":"2023-10-06T00:00:00Z","timestamp":1696550400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,10,6]],"date-time":"2023-10-06T00:00:00Z","timestamp":1696550400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol Phys Technol"],"published-print":{"date-parts":[[2023,12]]},"DOI":"10.1007\/s12194-023-00745-y","type":"journal-article","created":{"date-parts":[[2023,10,6]],"date-time":"2023-10-06T14:01:34Z","timestamp":1696600894000},"page":"578-583","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Shifting-field-of-view technique enhancing the inflow effect for identifying tumor\/vessel boundaries in MRI for radiotherapy treatment planning"],"prefix":"10.1007","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8012-4617","authenticated-orcid":false,"given":"Yutaka","family":"Kato","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kuniyasu","family":"Okudaira","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yumiko","family":"Noguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mariko","family":"Kawamura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shunichi","family":"Ishihara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shinji","family":"Naganawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,10,6]]},"reference":[{"issue":"1","key":"745_CR1","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1186\/s13014-023-02209-4","volume":"18","author":"D Moore-Palhares","year":"2023","unstructured":"Moore-Palhares D, Ho L, Lu L, Chugh B, Vesprini D, Karam I, Soliman H, Symons S, Leung E, Loblaw A, Myrehaug S, Stanisz G, Sahgal A, Czarnota GJ. Clinical implementation of magnetic resonance imaging simulation for radiation oncology planning: 5 year experience. Radiat Oncol. 2023;18(1):27. https:\/\/doi.org\/10.1186\/s13014-023-02209-4.","journal-title":"Radiat Oncol"},{"issue":"2","key":"745_CR2","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1148\/radiol.2020202747","volume":"298","author":"R Otazo","year":"2021","unstructured":"Otazo R, Lambin P, Pignol JP, Ladd ME, Schlemmer HP, Baumann M, Hricak H. MRI-guided radiation therapy: an emerging paradigm in adaptive radiation oncology. Radiology. 2021;298(2):248\u201360. https:\/\/doi.org\/10.1148\/radiol.2020202747.","journal-title":"Radiology"},{"issue":"2","key":"745_CR3","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1007\/s12194-018-0452-7","volume":"11","author":"K Usui","year":"2018","unstructured":"Usui K, Sasai K, Ogawa K. Effect of region extraction and assigned mass-density values on the accuracy of dose calculation with magnetic resonance-based volumetric arc therapy planning. Radiol Phys Technol. 2018;11(2):174\u201383. https:\/\/doi.org\/10.1007\/s12194-018-0452-7.","journal-title":"Radiol Phys Technol"},{"issue":"3","key":"745_CR4","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/0730-725x(86)91059-3","volume":"4","author":"L Axel","year":"1986","unstructured":"Axel L, Shimakawa A, MacFall J. A time-of-flight method of measuring flow velocity by magnetic resonance imaging. Magn Reson Imaging. 1986;4(3):199\u2013205. https:\/\/doi.org\/10.1016\/0730-725x(86)91059-3.","journal-title":"Magn Reson Imaging"},{"issue":"2","key":"745_CR5","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1007\/s12194-015-0307-4","volume":"8","author":"Y Fujiwara","year":"2015","unstructured":"Fujiwara Y, Ishimori Y, Yamaguchi I, Kosaka N, Kimura H, Adachi T. Fat-subtracted three-dimensional time-of-flight MR angiography of the neck by use of fat-only images with the two-point Dixon technique. Radiol Phys Technol. 2015;8(2):193\u20139. https:\/\/doi.org\/10.1007\/s12194-015-0307-4.","journal-title":"Radiol Phys Technol"},{"issue":"1","key":"745_CR6","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/0037-198x(92)90046-5","volume":"27","author":"D Chien","year":"1992","unstructured":"Chien D, Edelman RR. Basic principles and clinical applications of magnetic resonance angiography. Semin Roentgenol. 1992;27(1):53\u201362. https:\/\/doi.org\/10.1016\/0037-198x(92)90046-5.","journal-title":"Semin Roentgenol"},{"issue":"3","key":"745_CR7","doi-asserted-by":"publisher","first-page":"876","DOI":"10.1148\/radiology.212.3.r99se34876","volume":"212","author":"NM Rofsky","year":"1999","unstructured":"Rofsky NM, Lee VS, Laub G, Pollack MA, Krinsky GA, Thomasson D, Ambrosino MM, Weinreb JC. Abdominal MR imaging with a volumetric interpolated breath-hold examination. Radiology. 1999;212(3):876\u201384. https:\/\/doi.org\/10.1148\/radiology.212.3.r99se34876.","journal-title":"Radiology"},{"issue":"5","key":"745_CR8","doi-asserted-by":"publisher","first-page":"1020","DOI":"10.1002\/jmri.24088","volume":"38","author":"MH Yu","year":"2013","unstructured":"Yu MH, Lee JM, Yoon JH, Kiefer B, Han JK, Choi BI. Clinical application of controlled aliasing in parallel imaging results in a higher acceleration (CAIPIRINHA)-volumetric interpolated breathhold (VIBE) sequence for gadoxetic acid-enhanced liver MR imaging. J Magn Reson Imaging. 2013;38(5):1020\u20136. https:\/\/doi.org\/10.1002\/jmri.24088.","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"745_CR9","doi-asserted-by":"publisher","first-page":"29","DOI":"10.18999\/nagjms.84.1.29","volume":"84","author":"Y Kato","year":"2022","unstructured":"Kato Y, Okudaira K, Kamomae T, Kumagai M, Nagai Y, Taoka T, Itoh Y, Naganawa S. <Editors\u2019 Choice> Evaluation of system-related magnetic resonance imaging geometric distortion in radiation therapy treatment planning: two approaches and effectiveness of three-dimensional distortion correction. Nagoya J Med Sci. 2022;84(1):29\u201341. https:\/\/doi.org\/10.18999\/nagjms.84.1.29.","journal-title":"Nagoya J Med Sci"},{"issue":"7","key":"745_CR10","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.27269","volume":"14","author":"M Kumagai","year":"2022","unstructured":"Kumagai M, Kawamura M, Kato Y, Okudaira K, Naganawa S. The impact of system-related magnetic resonance imaging geometric distortion in stereotactic radiotherapy: a case report. Cureus. 2022;14(7): e27269. https:\/\/doi.org\/10.7759\/cureus.27269.","journal-title":"Cureus"},{"issue":"2","key":"745_CR11","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1159\/000343865","volume":"3","author":"T Ichikawa","year":"2014","unstructured":"Ichikawa T, Sano K, Morisaka H. Diagnosis of pathologically early HCC with EOB-MRI: experiences and current consensus. Liver Cancer. 2014;3(2):97\u2013107. https:\/\/doi.org\/10.1159\/000343865.","journal-title":"Liver Cancer"},{"issue":"1","key":"745_CR12","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1007\/s12194-018-00495-2","volume":"12","author":"B Yang","year":"2019","unstructured":"Yang B, Chiu TL, Law WK, Geng H, Lam WW, Leung TM, Yiu LH, Cheung KY, Yu SK. Performance evaluation of the CyberKnife system in real-time target tracking during beam delivery using a moving phantom coupled with two-dimensional detector array. Radiol Phys Technol. 2019;12(1):86\u201395. https:\/\/doi.org\/10.1007\/s12194-018-00495-2.","journal-title":"Radiol Phys Technol"}],"container-title":["Radiological Physics and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-023-00745-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12194-023-00745-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-023-00745-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,22]],"date-time":"2023-11-22T16:21:49Z","timestamp":1700670109000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12194-023-00745-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,6]]},"references-count":12,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2023,12]]}},"alternative-id":["745"],"URL":"https:\/\/doi.org\/10.1007\/s12194-023-00745-y","relation":{},"ISSN":["1865-0333","1865-0341"],"issn-type":[{"type":"print","value":"1865-0333"},{"type":"electronic","value":"1865-0341"}],"subject":[],"published":{"date-parts":[[2023,10,6]]},"assertion":[{"value":"31 July 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 September 2023","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 September 2023","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 October 2023","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All the authors declare that they have no conflicts of interest regarding this manuscript.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All the procedures involving human participants performed in this study were in accordance with the ethical standards of our Institutional Review Board (IRB, No: 2023-0149) and the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. This article does not report any animal studies.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}