{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T15:58:21Z","timestamp":1786982301590,"version":"build-2736575974"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,1,19]],"date-time":"2024-01-19T00:00:00Z","timestamp":1705622400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,1,19]],"date-time":"2024-01-19T00:00:00Z","timestamp":1705622400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"General Sir John Kotelawala Defence University","award":["KDU\/RG\/2021\/FAHS\/003"],"award-info":[{"award-number":["KDU\/RG\/2021\/FAHS\/003"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol Phys Technol"],"published-print":{"date-parts":[[2024,3]]},"DOI":"10.1007\/s12194-023-00774-7","type":"journal-article","created":{"date-parts":[[2024,1,19]],"date-time":"2024-01-19T00:02:19Z","timestamp":1705622539000},"page":"258-268","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Assessment of dosimetric approaches in evaluating radiation exposure for interventional cardiologists in Sri Lanka"],"prefix":"10.1007","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6400-0008","authenticated-orcid":false,"given":"Sachini Udara","family":"Wickramasinghe","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5470-6637","authenticated-orcid":false,"given":"Vijitha","family":"Ramanathan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0854-2077","authenticated-orcid":false,"given":"Sivananthan","family":"Sarasanandarajah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,1,19]]},"reference":[{"key":"774_CR1","unstructured":"http:\/\/www.statistics.gov.lk\/. The Department of Census and Statistics, Sri Lanka. 2023. 2023. Accessed 4 Oct 2023."},{"key":"774_CR2","unstructured":"Sri Lanka College of Cardiology [Internet]. 2023. Available from: https:\/\/slcc.lk\/, URL: https:\/\/slcc.lk\/. Accessed 4 Oct 2023."},{"key":"774_CR3","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1166\/jmihi.2015.1438","volume":"5","author":"H Moladoust","year":"2015","unstructured":"Moladoust H, Ghazanfari-Tehran M, Nikseresht V, Nadim T, Rad MA. Comparison of five developed algorithms to estimate staff effective dose in interventional cardiology: Are they interchangeable? J Med Imaging Heal Informatics. 2015;5:647\u201351. https:\/\/doi.org\/10.1166\/jmihi.2015.1438.","journal-title":"J Med Imaging Heal Informatics"},{"key":"774_CR4","doi-asserted-by":"publisher","first-page":"1648","DOI":"10.21037\/jtd.2019.12.86","volume":"12","author":"SMR Biso","year":"2020","unstructured":"Biso SMR, Vidovich MI. Radiation protection in the cardiac catheterization laboratory. J Thorac Dis. 2020;12:1648\u201355. https:\/\/doi.org\/10.21037\/jtd.2019.12.86.","journal-title":"J Thorac Dis"},{"key":"774_CR5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/0146-6453(81)90127-5","volume":"6","author":"FD Sowby","year":"1981","unstructured":"Sowby FD. Annals of the ICRP. Ann ICRP. 1981;6:1. https:\/\/doi.org\/10.1016\/0146-6453(81)90127-5.","journal-title":"Ann ICRP"},{"key":"774_CR6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/0146645317750356","volume":"47","author":"PO L\u00f3pez","year":"2018","unstructured":"L\u00f3pez PO, Dauer LT, Loose R, Martin CJ, Miller DL, Va\u00f1\u00f3 E, Doruff M, Padovani R, Massera G, Yoder C. ICRP Publication 139: Occupational Radiological Protection in Interventional Procedures. Ann ICRP. 2018;47:1\u2013118. https:\/\/doi.org\/10.1177\/0146645317750356.","journal-title":"Ann ICRP"},{"key":"774_CR7","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1088\/0952-4746\/32\/1\/E03","volume":"32","author":"CJ Martin","year":"2012","unstructured":"Martin CJ. Personnel dosimetry in UK radiology: Is it time for a change? J Radiol Prot. 2012;32:2\u20136. https:\/\/doi.org\/10.1088\/0952-4746\/32\/1\/E03.","journal-title":"J Radiol Prot"},{"key":"774_CR8","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1007\/s00270-008-9307-7","volume":"31","author":"G Kuipers","year":"2008","unstructured":"Kuipers G, Velders XL, De Winter RJ, Reekers JA, Piek JJ. Evaluation of the occupational doses of interventional radiologists. Cardiovasc Intervent Radiol. 2008;31:483\u20139. https:\/\/doi.org\/10.1007\/s00270-008-9307-7.","journal-title":"Cardiovasc Intervent Radiol"},{"key":"774_CR9","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1093\/rpd\/ncn239","volume":"131","author":"H J\u00e4rvinen","year":"2008","unstructured":"J\u00e4rvinen H, Buls N, Clerinx P, Miljani\u0107 S, Nikodemov\u00e1 D, Ranogajec-komor M, Struelens L, d\u2019Errico F. Comparison of double dosimetry algorithms for estimating the effective dose in occupational dosimetry of interventional radiology staff. Radiat Prot Dosimetry. 2008;131:80\u20136. https:\/\/doi.org\/10.1093\/rpd\/ncn239.","journal-title":"Radiat Prot Dosimetry"},{"key":"774_CR10","doi-asserted-by":"publisher","first-page":"639","DOI":"10.1259\/bjr\/24828606","volume":"84","author":"CJ Martin","year":"2011","unstructured":"Martin CJ. Personal dosimetry for interventional operators: when and how should monitoring be done? Br J Radiol. 2011;84:639\u201348. https:\/\/doi.org\/10.1259\/bjr\/24828606.","journal-title":"Br J Radiol"},{"key":"774_CR11","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1093\/rpd\/ncp155","volume":"136","author":"G Kuipers","year":"2009","unstructured":"Kuipers G, Velders XL. Effective dose to staff from interventional procedures: estimations from single and double dosimetry. Radiat Prot Dosimetry. 2009;136:95\u2013100. https:\/\/doi.org\/10.1093\/rpd\/ncp155.","journal-title":"Radiat Prot Dosimetry"},{"key":"774_CR12","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1093\/rpd\/ncl018","volume":"118","author":"FW Schultz","year":"2006","unstructured":"Schultz FW, Zoetelief J. Estimating effective dose for a cardiac catheterisation procedure with single or double personal dosemeters. Radiat Prot Dosimetry. 2006;118:196\u2013204. https:\/\/doi.org\/10.1093\/rpd\/ncl018.","journal-title":"Radiat Prot Dosimetry"},{"key":"774_CR13","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1093\/oxfordjournals.rpd.a006471","volume":"94","author":"R Padovani","year":"2001","unstructured":"Padovani R, Foti C, Malisan MR. Staff dosimetry protocols in interventional radiology. Radiat Prot Dosimetry. 2001;94:193\u20136. https:\/\/doi.org\/10.1093\/oxfordjournals.rpd.a006471.","journal-title":"Radiat Prot Dosimetry"},{"key":"774_CR14","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1097\/00004032-199412000-00003","volume":"67","author":"LT Niklason","year":"1994","unstructured":"Niklason LT, Victoria Marx M, Chan HP. The estimation of occupational effective dose in diagnostic radiology with two dosimeters. Health Phys. 1994;67:611\u20135. https:\/\/doi.org\/10.1097\/00004032-199412000-00003.","journal-title":"Health Phys"},{"key":"774_CR15","unstructured":"The Swiss Federal Department of the Interior and the Federal Department of the Environment, Transport E and C. Swiss Ordinance for personal dosimetry (Dosimetry Regulation). 1994, Swiss Ordinance for personal dosimetry, edited by the Federal Chancellery, Bern 1999."},{"key":"774_CR16","volume-title":"Personnel dosimetry in fluoroscopy","author":"S Baechler","year":"2006","unstructured":"Baechler S, Gardon M, Bochud F, Sans-Merce M, Trueb Ph, Verdun FR. Personnel dosimetry in fluoroscopy. Paris: Proc. of Second European IRPA Congress, (Soci\u00e9t\u00e9 Fran\u00e7arse de Radioprotection) P-091, 1\u201310, 2006."},{"key":"774_CR17","doi-asserted-by":"publisher","first-page":"800","DOI":"10.1097\/HP.0b013e3181e850da","volume":"99","author":"H Von Boetticher","year":"2010","unstructured":"Von Boetticher H, Lachmund J, Hoffmann W. An analytic approach to double dosimetry algorithms in occupational dosimetry using energy dependent organ dose conversion coefficients. Health Phys. 2010;99:800\u20135. https:\/\/doi.org\/10.1097\/HP.0b013e3181e850da.","journal-title":"Health Phys"},{"key":"774_CR18","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1097\/HP.0b013e31824dae76","volume":"103","author":"KP Kim","year":"2008","unstructured":"Kim KP, Miller DL, Balter S, Kleinerman RA, Linet MS, Kwon D, Simon SL. Occupational radiation doses to operators performing cardiac catheterization procedures. Health Phys. 2008;103:80\u201399. https:\/\/doi.org\/10.1097\/HP.0b013e31824dae76.","journal-title":"Health Phys"},{"key":"774_CR19","doi-asserted-by":"publisher","first-page":"901","DOI":"10.4103\/0973-1482.192767.Cited:in:","volume":"13","author":"R Fardid","year":"2017","unstructured":"Fardid R, Mirzadeh F, Rezaei H. Occupational doses of cardiologists in cath labs and simulation method. J Cancer Res Ther. 2017;13:901\u20137. https:\/\/doi.org\/10.4103\/0973-1482.192767.Cited:in: (PMID: 29237950).","journal-title":"J Cancer Res Ther"},{"key":"774_CR20","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1093\/rpd\/ncn296","volume":"132","author":"GU Paulsen","year":"2008","unstructured":"Paulsen GU. Assessment of effective dose and dose to the lens. Radiat Prot Dosimetry. 2008;132:313\u20138.","journal-title":"Radiat Prot Dosimetry"},{"key":"774_CR21","unstructured":"Aalbers T, Duane S, Kapsch R-P, Meghzifene A. Measurement uncertainty\u2014a practical guide for secondary standards dosimetry laboratories. 2008. URL: https:\/\/www-pub.iaea.org\/MTCD\/publications\/PDF\/te_1585_web.pdf. Accessed 4 Oct 2023."},{"key":"774_CR22","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1093\/rpd\/nci764","volume":"117","author":"A Trianni","year":"2006","unstructured":"Trianni A, Padovani R, Foti C, Cragnolini E, Chizzola G, Toh H, Bernardi G, Proclemer A. Dose to cardiologists in haemodynamic and electrophysiology cardiac interventional procedures. Radiat Prot Dosimetry. 2006;117:111\u20135. https:\/\/doi.org\/10.1093\/rpd\/nci764.","journal-title":"Radiat Prot Dosimetry"},{"key":"774_CR23","doi-asserted-by":"publisher","first-page":"1095","DOI":"10.1016\/j.jcin.2013.05.012","volume":"6","author":"M Ingwersen","year":"2013","unstructured":"Ingwersen M, Drabik A, Kulka U, Oestreicher U, Fricke S, Krankenberg H, Schwencke C, Mathey D. Physicians\u2019 radiation exposure in the catheterization lab: Does the type of procedure matter? JACC Cardiovasc Interv. 2013;6:1095\u2013102. https:\/\/doi.org\/10.1016\/j.jcin.2013.05.012.","journal-title":"JACC Cardiovasc Interv"},{"key":"774_CR24","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1093\/rpd\/ncv439","volume":"170","author":"J Kaljevic","year":"2016","unstructured":"Kaljevic J, Ciraj-Bjelac O, Stankovic J, Arandjic D, Bozovic P, Antic V. Occupational dose assessment in interventional cardiology in Serbia. Radiat Prot Dosimetry. 2016;170:279\u201383. https:\/\/doi.org\/10.1093\/rpd\/ncv439.","journal-title":"Radiat Prot Dosimetry"},{"key":"774_CR25","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/694\/1\/012035","author":"NA Bahruddin","year":"2016","unstructured":"Bahruddin NA, Hashim S, Karim MKA, Sabarudin A, Ang WC, Salehhon N, Bakar KA. Radiation dose to physicians\u2019 eye lens during interventional radiology. J Phys Conf Ser. 2016. https:\/\/doi.org\/10.1088\/1742-6596\/694\/1\/012035.","journal-title":"J Phys Conf Ser"},{"key":"774_CR26","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1371\/journal.pone.0286400","volume":"18","author":"TG Alemayehu","year":"2023","unstructured":"Alemayehu TG, Bogale GG, Bazie GW. Occupational radiation exposure dose and associated factors among radiology personnel in Eastern Amhara, Ethiopia. PLoS One [Internet]. 2023;18:1\u201314. https:\/\/doi.org\/10.1371\/journal.pone.0286400.","journal-title":"PLoS One [Internet]"},{"key":"774_CR27","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1093\/rpd\/ncaa019","volume":"189","author":"J Kim","year":"2020","unstructured":"Kim J, Seo S, Lee DN, Park S, Im KJ, Park S, Jin YW. Occupational exposure characteristics and factors associated with radiation doses among Korean Radiation Workers. Radiat Prot Dosimetry. 2020;189:106\u201313. https:\/\/doi.org\/10.1093\/rpd\/ncaa019.","journal-title":"Radiat Prot Dosimetry"},{"key":"774_CR28","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1016\/j.radphyschem.2018.09.008","volume":"153","author":"EZ Dalah","year":"2018","unstructured":"Dalah EZ, Mahdi O, Elshami W, Abuzaid MM, David LR, Mira OA, Obaideen A, Elmahdi HM, Bradley DA. Occupational doses to cardiologists performing fluoroscopically-guided procedures. Radiat Phys Chem [Internet]. 2018;153:21\u20136. https:\/\/doi.org\/10.1016\/j.radphyschem.2018.09.008.","journal-title":"Radiat Phys Chem [Internet]"},{"key":"774_CR29","first-page":"53","volume":"10","author":"M Najafi","year":"2012","unstructured":"Najafi M, Nedaie HA, Lahooti A, Omranipour R, Nafissi N, Akbari ME, Olfatbakhsh A, Kaviani A, Alavi N. Radiation exposure of the surgeons in sentinel lymph node biopsy. Iran J Radiat Res. 2012;10:53\u20137.","journal-title":"Iran J Radiat Res"}],"container-title":["Radiological Physics and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-023-00774-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12194-023-00774-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-023-00774-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,28]],"date-time":"2024-02-28T12:20:05Z","timestamp":1709122805000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12194-023-00774-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,19]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024,3]]}},"alternative-id":["774"],"URL":"https:\/\/doi.org\/10.1007\/s12194-023-00774-7","relation":{},"ISSN":["1865-0333","1865-0341"],"issn-type":[{"value":"1865-0333","type":"print"},{"value":"1865-0341","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,19]]},"assertion":[{"value":"5 October 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 December 2023","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 December 2023","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 January 2024","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All the authors have declared no conflict of interest. The study obtained institutional ethical clearance and informed consent from all the participants.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}