{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T16:47:50Z","timestamp":1793378870045,"version":"4.5.0"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2025,6,23]],"date-time":"2025-06-23T00:00:00Z","timestamp":1750636800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,6,23]],"date-time":"2025-06-23T00:00:00Z","timestamp":1750636800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["22K15823"],"award-info":[{"award-number":["22K15823"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol Phys Technol"],"published-print":{"date-parts":[[2025,9]]},"DOI":"10.1007\/s12194-025-00929-8","type":"journal-article","created":{"date-parts":[[2025,6,23]],"date-time":"2025-06-23T05:46:00Z","timestamp":1750657560000},"page":"929-936","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Clinical technique:\u00a0evaluation of detection accuracy in surface-guided radiation therapy using CT references from different treatment planning systems"],"prefix":"10.1007","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8636-4045","authenticated-orcid":false,"given":"Masahide","family":"Saito","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koji","family":"Ueda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hikaru","family":"Nemoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryota","family":"Tozuka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yosuke","family":"Miyasaka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshiko","family":"Onishi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Syuichiro","family":"Sugiyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yumi","family":"Sasada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naoki","family":"Sano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Onishi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,6,23]]},"reference":[{"issue":"1","key":"929_CR1","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1186\/s13014-020-01629-w","volume":"15","author":"P Freislederer","year":"2020","unstructured":"Freislederer P, Kugele M, Ollers M, Swinnen A, Sauer TO, Bert C, et al. Recent advanced in surface guided radiation therapy. Radiat Oncol. 2020;15(1):187.","journal-title":"Radiat Oncol"},{"key":"929_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.tipsro.2022.03.003","volume":"22","author":"V Batista","year":"2022","unstructured":"Batista V, Gober M, Moura F, Webster A, Oellers M, Ramtohul M, et al. Surface guided radiation therapy: an international survey on current clinical practice. Tech Innov Patient Support Radiat Oncol. 2022;22:1\u20138.","journal-title":"Tech Innov Patient Support Radiat Oncol"},{"issue":"1","key":"929_CR3","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.prro.2012.03.002","volume":"3","author":"AP Shah","year":"2013","unstructured":"Shah AP, Dvorak T, Curry MS, Buchholz DJ, Meeks SL. Clinical evaluation of interfractional variations for whole breast radiotherapy using 3-dimensional surface imaging. Pract Radiat Oncol. 2013;3(1):16\u201325.","journal-title":"Pract Radiat Oncol"},{"key":"929_CR4","doi-asserted-by":"crossref","unstructured":"Al\u2010Hallaq HA, Cervi\u00f1o L, Gutierrez AN, Havnen\u2010Smith A, Higgins SA, K\u00fcgele M, et al. AAPM task group report 302: Surface guided radiotherapy. Medical Physics. 2022.","DOI":"10.1002\/mp.15532"},{"issue":"13","key":"929_CR5","doi-asserted-by":"publisher","first-page":"3949","DOI":"10.1088\/0031-9155\/52\/13\/019","volume":"52","author":"PJ Sch\u00f6ffel","year":"2007","unstructured":"Sch\u00f6ffel PJ, Harms W, Sroka-Perez G, Schlegel W, Karger CP. Accuracy of a commercial optical 3D surface imaging system for realignment of patients for radiotherapy of the thorax. Phys Med Biol. 2007;52(13):3949.","journal-title":"Phys Med Biol"},{"issue":"1","key":"929_CR6","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1186\/s13014-016-0728-1","volume":"11","author":"F Walter","year":"2016","unstructured":"Walter F, Freislederer P, Belka C, Heinz C, Sohn M, Roeder F. Evaluation of daily patient positioning for radiotherapy with a commercial 3D surface-imaging system (Catalyst). Radiat Oncol. 2016;11(1):154.","journal-title":"Radiat Oncol"},{"issue":"10","key":"929_CR7","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.14058","volume":"24","author":"EL Covington","year":"2023","unstructured":"Covington EL, Stanley DN, Sullivan RJ, Riley KO, Fiveash JB, Popple RA. Commissioning and clinical evaluation of the IDENTIFY(TM) surface imaging system for frameless stereotactic radiosurgery. J Appl Clin Med Phys. 2023;24(10): e14058.","journal-title":"J Appl Clin Med Phys"},{"issue":"10","key":"929_CR8","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13754","volume":"23","author":"MV Da Silva","year":"2022","unstructured":"Da Silva MV, Reiner M, Huang L, Reitz D, Straub K, Corradini S, et al. ExacTrac Dynamic workflow evaluation: Combined surface optical\/thermal imaging and X-ray positioning. J Appl Clin Med Phys. 2022;23(10): e13754.","journal-title":"J Appl Clin Med Phys"},{"issue":"3","key":"929_CR9","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1093\/jrr\/rrac015","volume":"63","author":"M Saito","year":"2022","unstructured":"Saito M, Ueda K, Suzuki H, Komiyama T, Marino K, Aoki S, et al. Evaluation of the detection accuracy of set-up for various treatment sites using surface-guided radiotherapy system, VOXELAN: a phantom study. J Radiat Res. 2022;63(3):435\u201342.","journal-title":"J Radiat Res"},{"key":"929_CR10","doi-asserted-by":"crossref","unstructured":"Saito M, Ueda K, Nemoto H, Onishi Y, Suzuki H, Suzuki T, et al. Development of a phantom for assessing the precision of setup in skin mark-less surface-guided radiotherapy. J Appl Clin Med Phys. 2024:e14381.","DOI":"10.1002\/acm2.14381"},{"key":"929_CR11","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1016\/j.radonc.2022.05.026","volume":"173","author":"P Freislederer","year":"2022","unstructured":"Freislederer P, Batista V, Ollers M, Buschmann M, Steiner E, Kugele M, et al. ESTRO-ACROP guideline on surface guided radiation therapy. Radiother Oncol. 2022;173:188\u201396.","journal-title":"Radiother Oncol"},{"issue":"4","key":"929_CR12","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1016\/j.canrad.2021.07.038","volume":"26","author":"R Komori","year":"2022","unstructured":"Komori R, Hayashi N, Saito T, Amma H, Muraki Y, Nozue M. Improvement of patient localization repeatability using a light-section based optical surface guidance system in a pre-positioning procedure. Cancer Radiother. 2022;26(4):547\u201356.","journal-title":"Cancer Radiother"},{"issue":"4","key":"929_CR13","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13872","volume":"24","author":"F Sasaki","year":"2023","unstructured":"Sasaki F, Yamashita Y, Nakano S, Ishikawa M. Verification of patient-setup accuracy using a surface imaging system with steep measurement angle. J Appl Clin Med Phys. 2023;24(4): e13872.","journal-title":"J Appl Clin Med Phys"},{"issue":"1","key":"929_CR14","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.14517","volume":"26","author":"N Hayashi","year":"2025","unstructured":"Hayashi N, Saito T, Ouchi K, Amma H, Muraki Y, Yasui K, et al. Development of dedicated phantom for end-to-end testing of multiple image-guidance configurations incorporating light-section-based surface guidance system. J Appl Clin Med Phys. 2025;26(1): e14517.","journal-title":"J Appl Clin Med Phys"},{"issue":"12","key":"929_CR15","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1002\/acm2.13081","volume":"21","author":"H Nakano","year":"2020","unstructured":"Nakano H, Tanabe S, Utsunomiya S, Yamada T, Sasamoto R, Nakano T, et al. Effect of setup error in the single-isocenter technique on stereotactic radiosurgery for multiple brain metastases. J Appl Clin Med Phys. 2020;21(12):155\u201365.","journal-title":"J Appl Clin Med Phys"},{"issue":"3","key":"929_CR16","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1002\/acm2.12815","volume":"21","author":"G Prentou","year":"2020","unstructured":"Prentou G, Pappas EP, Logothetis A, Koutsouveli E, Pantelis E, Papagiannis P, et al. Dosimetric impact of rotational errors on the quality of VMAT-SRS for multiple brain metastases: Comparison between single- and two-isocenter treatment planning techniques. J Appl Clin Med Phys. 2020;21(3):32\u201344.","journal-title":"J Appl Clin Med Phys"},{"issue":"3","key":"929_CR17","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1007\/s12194-023-00726-1","volume":"16","author":"T Saito","year":"2023","unstructured":"Saito T, Hayashi N, Amma H, Onishi K, Muraki Y, Nozue M. Development of a new coordinate calibration phantom for a light-section-based optical surface monitoring system. Radiol Phys Technol. 2023;16(3):366\u201372.","journal-title":"Radiol Phys Technol"}],"container-title":["Radiological Physics and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-025-00929-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12194-025-00929-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-025-00929-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,6]],"date-time":"2025-09-06T21:30:33Z","timestamp":1757194233000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12194-025-00929-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,23]]},"references-count":17,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,9]]}},"alternative-id":["929"],"URL":"https:\/\/doi.org\/10.1007\/s12194-025-00929-8","relation":{},"ISSN":["1865-0333","1865-0341"],"issn-type":[{"value":"1865-0333","type":"print"},{"value":"1865-0341","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,23]]},"assertion":[{"value":"20 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 June 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 June 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 June 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was supported by joint research with APEX Medical Inc. and Hamano Engineering.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"No approval from research ethics committees was required for this study, as the experimental work was conducted using nonhuman phantoms.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}