{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T18:22:27Z","timestamp":1790706147439,"version":"4.1.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2025,8,22]],"date-time":"2025-08-22T00:00:00Z","timestamp":1755820800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,8,22]],"date-time":"2025-08-22T00:00:00Z","timestamp":1755820800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol Phys Technol"],"published-print":{"date-parts":[[2025,12]]},"DOI":"10.1007\/s12194-025-00953-8","type":"journal-article","created":{"date-parts":[[2025,8,22]],"date-time":"2025-08-22T06:48:25Z","timestamp":1755845305000},"page":"1064-1071","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Thyroid radiation dose reduction with the use of thyroid shields during CT brain studies"],"prefix":"10.1007","volume":"18","author":[{"given":"Vimukthi","family":"Gunathilaka","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Menaka","family":"Sampath","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nuwan Darshana","family":"Wickramasinghe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9183-2395","authenticated-orcid":false,"given":"Mihiri Chami","family":"Wettasinghe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,8,22]]},"reference":[{"issue":"8","key":"953_CR1","doi-asserted-by":"publisher","first-page":"LC07","DOI":"10.7860\/JCDR\/2016\/20398.8394","volume":"10","author":"KJ Awosan","year":"2016","unstructured":"Awosan KJ, Ibrahim M, Saidu SA, Ma\u2019aji SM, Danfulani M, Yunusa EU, Ikhuenbor DB, Ige TA. Knowledge of radiation hazards, radiation protection practices and clinical profile of health workers in a teaching hospital in Northern Nigeria. J Clin Diagn Res. 2016;10(8):LC07-12. https:\/\/doi.org\/10.7860\/JCDR\/2016\/20398.8394.","journal-title":"J Clin Diagn Res"},{"key":"953_CR2","unstructured":"United Nations Scientific Committee on the Effects of Atomic Radiation. Sources, effects and risks of ionizing radiation, United Nations scientific committee on the effects of atomic radiation (UNSCEAR) 2020\/2021 report, volume IV: scientific annex D-evaluation of occupational exposure to ionizing radiation. United Nations. 2022."},{"key":"953_CR3","doi-asserted-by":"publisher","first-page":"664","DOI":"10.1007\/s003300050456","volume":"8","author":"T Beaconsfield","year":"1998","unstructured":"Beaconsfield T, Nicholson R, Thornton A, Al-Kutoubi A. Would thyroid and breast shielding be beneficial in CT of the head? Eur Radiol. 1998;8:664\u20137.","journal-title":"Eur Radiol"},{"issue":"2","key":"953_CR4","first-page":"530","volume":"7","author":"D Robinson","year":"2019","unstructured":"Robinson D, Nzotta CC, Onwuchekwa I. Evaluation of scatter radiation to the thyroid gland attributable to brain computed tomography scan in Port Harcourt, Nigeria. Int J Res Med Sci. 2019;7(2):530\u20135.","journal-title":"Int J Res Med Sci"},{"issue":"2","key":"953_CR5","doi-asserted-by":"publisher","first-page":"159","DOI":"10.3346\/jkms.2004.19.2.159","volume":"19","author":"MK Kalra","year":"2004","unstructured":"Kalra MK, Maher MM, Rizzo S, Kanarek D, Shepard JA. Radiation exposure from chest CT: issues and strategies. J Korean Med Sci. 2004;19(2):159\u201366. https:\/\/doi.org\/10.3346\/jkms.2004.19.2.159.","journal-title":"J Korean Med Sci"},{"issue":"5","key":"953_CR6","doi-asserted-by":"publisher","first-page":"756","DOI":"10.1210\/er.2010-0003","volume":"31","author":"B Sinnott","year":"2010","unstructured":"Sinnott B, Ron E, Schneider AB. Exposing the thyroid to radiation: a review of its current extent, risks, and implications. Endocr Rev. 2010;31(5):756\u201373. https:\/\/doi.org\/10.1210\/er.2010-0003.","journal-title":"Endocr Rev"},{"issue":"3","key":"953_CR7","doi-asserted-by":"publisher","first-page":"704","DOI":"10.1016\/j.radi.2022.04.005","volume":"28","author":"J Jeyasugiththan","year":"2022","unstructured":"Jeyasugiththan J, Kumarihami AMC, Satharasinghe D, Mahakumara P, Senanayaka G, Jayakody I. Evaluation of thyroid radiation dose during abdominal computed tomography procedures and dose reduction effectiveness of thyroid shielding. Radiography. 2022;28(3):704\u201310.","journal-title":"Radiography"},{"issue":"1","key":"953_CR8","doi-asserted-by":"publisher","DOI":"10.1177\/1559325818822602","volume":"17","author":"M Yanovskiy","year":"2019","unstructured":"Yanovskiy M, Shaki YY, Socol Y. Ethics of adoption and use of the linear no-threshold model. Dose Response. 2019;17(1): 1559325818822602. https:\/\/doi.org\/10.1177\/1559325818822602.","journal-title":"Dose Response"},{"issue":"1","key":"953_CR9","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1016\/j.sjbs.2020.10.010","volume":"28","author":"H Omer","year":"2021","unstructured":"Omer H, Alameen S, Mahmoud WE, Sulieman A, Nasir O, Abolaban F. Eye lens and thyroid gland radiation exposure for patients undergoing brain computed tomography examination. Saudi J Biol Sci. 2021;28(1):342\u20136. https:\/\/doi.org\/10.1016\/j.sjbs.2020.10.010.","journal-title":"Saudi J Biol Sci"},{"issue":"6","key":"953_CR10","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1097\/HP.0000000000000723","volume":"113","author":"LA Chang","year":"2017","unstructured":"Chang LA, Miller DL, Lee C, Melo DR, Villoing D, Drozdovitch V, Thierry-Chef I, Winters SJ, Labrake M, Myers CF, Lim H, Kitahara CM, Linet MS, Simon SL. Thyroid radiation dose to patients from diagnostic radiology procedures over eight decades: 1930\u20132010. Health Phys. 2017;113(6):458\u201373. https:\/\/doi.org\/10.1097\/HP.0000000000000723.","journal-title":"Health Phys"},{"issue":"56","key":"953_CR11","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1093\/jncimonographs\/lgaa010","volume":"2020","author":"M Hauptmann","year":"2020","unstructured":"Hauptmann M, Daniels RD, Cardis E, Cullings HM, Kendall G, Laurier D, Linet MS, Little MP, Lubin JH, Preston DL, Richardson DB, Stram DO, Thierry-Chef I, Schubauer-Berigan MK, Gilbert ES. Berrington de Gonzalez A. Epidemiological studies of low-dose ionizing radiation and cancer: summary bias assessment and meta-analysis. J Natl Cancer Inst Monogr. 2020;2020(56):188\u2013200. https:\/\/doi.org\/10.1093\/jncimonographs\/lgaa010. (Erratum in: J Natl Cancer Inst Monogr. 2023 May 4;2023(61):e1. 10.1093\/jncimonographs\/lgac027. PMID: 32657347; PMCID: PMC8454205).","journal-title":"J Natl Cancer Inst Monogr"},{"issue":"11","key":"953_CR12","doi-asserted-by":"publisher","first-page":"3873","DOI":"10.3390\/ijerph17113873","volume":"17","author":"SL Tsao","year":"2020","unstructured":"Tsao SL, Chen YY, Yeh LT, Huang JY, Li WT, Yang SF, Yeh CB. Impact of computed tomography scans on the risk of thyroid disease in minor head injury patients: a population-based retrospective cohort study. Int J Environ Res Public Health. 2020;17(11):3873.","journal-title":"Int J Environ Res Public Health"},{"issue":"10","key":"953_CR13","doi-asserted-by":"publisher","first-page":"787","DOI":"10.3390\/diagnostics10100787","volume":"10","author":"CC Yang","year":"2020","unstructured":"Yang CC. Evaluation of impact of factors affecting CT radiation dose for optimizing patient dose levels. Diagnostics. 2020;10(10):787.","journal-title":"Diagnostics"},{"issue":"1","key":"953_CR14","doi-asserted-by":"publisher","first-page":"31","DOI":"10.4103\/ajprhc.ajprhc_121_23","volume":"16","author":"MM Jaseemudheen","year":"2024","unstructured":"Jaseemudheen MM, Uppoor R, D Souza JT. Estimation of entrance surface radiation dose to thyroid and gonads during computed tomography thorax examination. Asian J Pharm Res Health Care. 2024;16(1):31\u20136. https:\/\/doi.org\/10.4103\/ajprhc.ajprhc_121_23.","journal-title":"Asian J Pharm Res Health Care"},{"issue":"1","key":"953_CR15","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/j.ejrad.2007.09.028","volume":"69","author":"P Dawson","year":"2009","unstructured":"Dawson P, Punwani S. The thyroid dose burden in medical imaging: a re-examination. Eur J Radiol. 2009;69(1):74\u20139.","journal-title":"Eur J Radiol"},{"key":"953_CR16","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.ejmp.2021.05.017","volume":"86","author":"C Candela-Juan","year":"2021","unstructured":"Candela-Juan C, Ciraj-Bjelac O, Merce MS, Dabin J, Faj D, Gallagher A, Theodorakou C. Use of out-of-field contact shielding on patients in medical imaging: a review of current guidelines, recommendations and legislative documents. Phys Med. 2021;86:44\u201356.","journal-title":"Phys Med"},{"issue":"5","key":"953_CR17","doi-asserted-by":"publisher","first-page":"1132","DOI":"10.2214\/AJR.11.7445","volume":"198","author":"JK Hoang","year":"2012","unstructured":"Hoang JK, Yoshizumi TT, Choudhury KR, Nguyen GB, Toncheva G, Gafton AR, Hurwitz LM. Organ-based dose current modulation and thyroid shields: techniques of radiation dose reduction for neck CT. AJR Am J Roentgenol. 2012;198(5):1132\u20138.","journal-title":"AJR Am J Roentgenol"},{"issue":"4","key":"953_CR18","doi-asserted-by":"publisher","first-page":"238","DOI":"10.4103\/0971-6203.144490","volume":"39","author":"P Akhlaghi","year":"2014","unstructured":"Akhlaghi P, Miri-Hakimabad H, Rafat-Motavalli L. Effects of shielding the radiosensitive superficial organs of ORNL pediatric phantoms on dose reduction in computed tomography. J Med Phys. 2014;39(4):238\u201346. https:\/\/doi.org\/10.4103\/0971-6203.144490.","journal-title":"J Med Phys"},{"issue":"3","key":"953_CR19","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr.20140285","volume":"44","author":"A Hidalgo","year":"2015","unstructured":"Hidalgo A, Davies J, Horner K, Theodorakou C. Effectiveness of thyroid gland shielding in dental CBCT using a paediatric anthropomorphic phantom. Dentomaxillofac Radiol. 2015;44(3): 20140285. https:\/\/doi.org\/10.1259\/dmfr.20140285.","journal-title":"Dentomaxillofac Radiol"},{"issue":"1","key":"953_CR20","doi-asserted-by":"publisher","first-page":"121","DOI":"10.22159\/ajpcr.2019.v12i1.28932","volume":"12","author":"T Visakh","year":"2019","unstructured":"Visakh T, Sukumar S, Pradhan A. Estimation of entrance surface radiation dose to thyroid region in computed tomography brain examination. Asian J Pharm Clin Res. 2019;12(1):121\u20133. https:\/\/doi.org\/10.22159\/ajpcr.2019.v12i1.28932.","journal-title":"Asian J Pharm Clin Res"},{"issue":"3","key":"953_CR21","first-page":"45","volume":"9","author":"MMEW Abuzaid","year":"2017","unstructured":"Abuzaid MMEW, Elshami W, Haneef C, Alyafei S. Thyroid shield during brain CT scan: dose reduction and image quality evaluation. Imaging Med. 2017;9(3):45\u20138.","journal-title":"Imaging Med"},{"issue":"5","key":"953_CR22","doi-asserted-by":"publisher","first-page":"446","DOI":"10.1016\/j.crad.2003.10.016","volume":"59","author":"DJ McLaughlin","year":"2004","unstructured":"McLaughlin DJ, Mooney RB. Dose reduction to radiosensitive tissues in CT. Do commercially available shields meet the users\u2019 needs? Clin Radiol. 2004;59(5):446\u201350.","journal-title":"Clin Radiol"},{"issue":"2","key":"953_CR23","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/j.radi.2005.05.001","volume":"12","author":"L Williams","year":"2006","unstructured":"Williams L, et al. Computed tomography of the head: an experimental study to investigate the effectiveness of lead shielding during three scanning protocols. Radiography. 2006;12(2):143\u201352.","journal-title":"Radiography"},{"issue":"7","key":"953_CR24","doi-asserted-by":"publisher","first-page":"20190014","DOI":"10.1259\/dmfr.20190014","volume":"48","author":"R Pauwels","year":"2019","unstructured":"Pauwels R, Horner K, Vassileva J, Rehani MM. Thyroid shielding in cone beam computed tomography: recommendations towards appropriate use. Dentomaxillofac Radiol. 2019;48(7):20190014. https:\/\/doi.org\/10.1259\/dmfr.20190014.","journal-title":"Dentomaxillofac Radiol"},{"issue":"5","key":"953_CR25","doi-asserted-by":"publisher","first-page":"1132","DOI":"10.2214\/AJR.11.7445","volume":"198","author":"JK Hoang","year":"2012","unstructured":"Hoang JK, Yoshizumi TT, Choudhury KR, Nguyen GB, Toncheva G, Gafton AR, Eastwood JD, Lowry C, Hurwitz LM. Organ-based dose current modulation and thyroid shields: techniques of radiation dose reduction for neck CT. AJR Am J Roentgenol. 2012;198(5):1132\u20138. https:\/\/doi.org\/10.2214\/AJR.11.7445.","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"953_CR26","doi-asserted-by":"publisher","first-page":"321","DOI":"10.4314\/ejhs.v33i2.17","volume":"33","author":"HM Derbew","year":"2023","unstructured":"Derbew HM, Kebede T, Teferi S, Otero HJ. Inadvertent thyroid radiation during computed tomography of the chest: a retrospective study. Ethiop J Health Sci. 2023;33(2):321\u20136. https:\/\/doi.org\/10.4314\/ejhs.v33i2.17.","journal-title":"Ethiop J Health Sci"},{"key":"953_CR27","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1186\/s13244-021-01085-4","volume":"12","author":"P Hiles","year":"2021","unstructured":"Hiles P, Gilligan P, Damilakis J, et al. European consensus on patient contact shielding. Insights Imaging. 2021;12:194. https:\/\/doi.org\/10.1186\/s13244-021-01085-4.","journal-title":"Insights Imaging"},{"issue":"2\u20134","key":"953_CR28","first-page":"1","volume":"37","author":"J Valentin","year":"2007","unstructured":"Valentin J. The 2007 recommendations of the international commission on radiological protection. Ann ICRP. 2007;37(2\u20134):1\u2013133.","journal-title":"Ann ICRP"},{"issue":"1","key":"953_CR29","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-85060-5","volume":"11","author":"K Yamashita","year":"2021","unstructured":"Yamashita K, Higashino K, Hayashi H, Takegami K, Hayashi F, Tsuruo Y, Sairyo K. Direct measurement of radiation exposure dose to individual organs during diagnostic computed tomography examination. Sci Rep. 2021;11(1): 5435. https:\/\/doi.org\/10.1038\/s41598-021-85060-5.","journal-title":"Sci Rep"},{"issue":"S1","key":"953_CR30","doi-asserted-by":"publisher","first-page":"129","DOI":"10.56899\/153.S1.12","volume":"153","author":"J Sanghu","year":"2024","unstructured":"Sanghu J, Dean KMR, Grande MLML, Panlaqui AA, Sanuan B. Impact of angular dependence on dose measurement for whole-body thermoluminescence dosimeters in clinical applications. Philipp J Sci. 2024;153(S1):129\u201337.","journal-title":"Philipp J Sci"},{"key":"953_CR31","unstructured":"https:\/\/www.fujielectric.com\/products\/sensors_measurements\/radiation\/product_series\/personal_dosei.html"},{"key":"953_CR32","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2020.109265","volume":"180","author":"M Saeedi-Moghadam","year":"2021","unstructured":"Saeedi-Moghadam M, Tayebi M, Chegeni N, Sina S, Kolayi T. Efficiency of non-lead and lead thyroid shields in radiation protection of CT examinations. Radiat Phys Chem. 2021;180: 109265.","journal-title":"Radiat Phys Chem"},{"issue":"3","key":"953_CR33","doi-asserted-by":"publisher","first-page":"20140285","DOI":"10.1259\/dmfr.20140285","volume":"44","author":"A Hidalgo","year":"2015","unstructured":"Hidalgo A, Davies J, Horner K, Theodorakou C. Effectiveness of thyroid gland shielding in dental CBCT using a paediatric anthropomorphic phantom. Dentomaxillofac Radiol. 2015;44(3):20140285.","journal-title":"Dentomaxillofac Radiol"},{"key":"953_CR34","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1186\/s41747-025-00562-5","volume":"9","author":"L Melazzini","year":"2025","unstructured":"Melazzini L, Bortolotto C, Brizzi L, et al. AI for image quality and patient safety in CT and MRI. Eur Radiol Exp. 2025;9:28. https:\/\/doi.org\/10.1186\/s41747-025-00562-5.","journal-title":"Eur Radiol Exp"},{"issue":"6","key":"953_CR35","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1016\/j.diii.2020.04.004","volume":"101","author":"M Sapoval","year":"2020","unstructured":"Sapoval M, Gaultier AL, Del Giudice C, Pellerin O, Kassis-Chikhani N, Lemarteleur V, Fouquet V, Tapie L, Morenton P, Tavitian B, Attal JP. 3D-printed face protective shield in interventional radiology: evaluation of an immediate solution in the era of COVID-19 pandemic. Diagn Interv Imaging. 2020;101(6):413\u20135. https:\/\/doi.org\/10.1016\/j.diii.2020.04.004.","journal-title":"Diagn Interv Imaging"}],"container-title":["Radiological Physics and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-025-00953-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12194-025-00953-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-025-00953-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,19]],"date-time":"2025-11-19T14:10:51Z","timestamp":1763561451000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12194-025-00953-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,22]]},"references-count":35,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,12]]}},"alternative-id":["953"],"URL":"https:\/\/doi.org\/10.1007\/s12194-025-00953-8","relation":{},"ISSN":["1865-0333","1865-0341"],"issn-type":[{"value":"1865-0333","type":"print"},{"value":"1865-0341","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,22]]},"assertion":[{"value":"29 April 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 August 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 August 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 August 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Ethical approval for this study was obtained from the Ethics Review Committee (ERC) of the Faculty of Allied Health Sciences, University of Peradeniya (ERC number AHS\/ERC\/2024\/095).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Written informed consent was obtained for anonymized patient information to be published in this article.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}