{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,28]],"date-time":"2026-02-28T11:16:59Z","timestamp":1772277419455,"version":"3.50.1"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T00:00:00Z","timestamp":1767916800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T00:00:00Z","timestamp":1767916800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol Phys Technol"],"published-print":{"date-parts":[[2026,3]]},"DOI":"10.1007\/s12194-026-01005-5","type":"journal-article","created":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T06:12:19Z","timestamp":1767939139000},"page":"270-283","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Evaluating the utility of simulated respiratory-gated four-dimensional computed tomography in internal-target-volume-based treatment planning for irregular breathing patterns"],"prefix":"10.1007","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-8905-3453","authenticated-orcid":false,"given":"Satoki","family":"Hinai","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keisuke","family":"Usui","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yusuke","family":"Obara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshiya","family":"Maebayashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoshi","family":"Ookubo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Atsushi","family":"Ichikawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshihisa","family":"Sasaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hajime","family":"Sakamoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shinsuke","family":"Kyogoku","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroyuki","family":"Daida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,1,9]]},"reference":[{"key":"1005_CR1","doi-asserted-by":"publisher","first-page":"933","DOI":"10.1016\/j.ijrobp.2004.06.021","volume":"60","author":"GS Mageras","year":"2004","unstructured":"Mageras GS, Pevsner A, Yorke ED, et al. Measurement of lung tumor motion using respiration-correlated CT. Int J Radiat Oncol Biol Phys. 2004;60:933\u201341. https:\/\/doi.org\/10.1016\/j.ijrobp.2004.06.021.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1005_CR2","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1053\/j.semradonc.2003.10.008","volume":"14","author":"H Shirato","year":"2004","unstructured":"Shirato H, Seppenwoolde Y, Kitamura K, Onimura R, Shimizu S. Intrafractional tumor motion: lung and liver. Semin Radiat Oncol. 2004;14:10\u20138. https:\/\/doi.org\/10.1053\/j.semradonc.2003.10.008.","journal-title":"Semin Radiat Oncol"},{"key":"1005_CR3","doi-asserted-by":"publisher","first-page":"554","DOI":"10.1016\/j.ijrobp.2005.01.032","volume":"62","author":"RW Underberg","year":"2005","unstructured":"Underberg RW, Lagerwaard FJ, Slotman BJ, Cuijpers JP, Senan S. Benefit of respiration-gated stereotactic radiotherapy for stage I lung cancer: an analysis of 4DCT datasets. Int J Radiat Oncol Biol Phys. 2005;62:554\u201360. https:\/\/doi.org\/10.1016\/j.ijrobp.2005.01.032.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1005_CR4","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1186\/s13014-022-02094-3","volume":"17","author":"Y Ryuno","year":"2022","unstructured":"Ryuno Y, Abe T, Iino M, et al. High-dose stereotactic body radiotherapy using CyberKnife\u00ae for stage I peripheral lung cancer: a single-center retrospective study. Radiat Oncol. 2022;17:128. https:\/\/doi.org\/10.1186\/s13014-022-02094-3.","journal-title":"Radiat Oncol"},{"key":"1005_CR5","doi-asserted-by":"publisher","first-page":"153303382513307","DOI":"10.1177\/15330338251330781","volume":"24","author":"Z Shen","year":"2025","unstructured":"Shen Z, Pan M, Sun L, et al. Comparative dosimetry and biological risk assessment of lung oligometastasis SBRT: VMAT, helical tomotherapy, and cyberknife. Technol Cancer Res Treat. 2025;24:15330338251330781. https:\/\/doi.org\/10.1177\/15330338251330781.","journal-title":"Technol Cancer Res Treat"},{"key":"1005_CR6","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1186\/s13014-016-0699-2","volume":"11","author":"J Kim","year":"2016","unstructured":"Kim J, Wu Q, Zhao B, et al. To gate or not to gate\u2014dosimetric evaluation comparing gated vs. ITV-based methodologies in stereotactic ablative body radiotherapy (SABR) treatment of lung cancer. Radiat Oncol. 2016;11:125. https:\/\/doi.org\/10.1186\/s13014-016-0699-2.","journal-title":"Radiat Oncol"},{"key":"1005_CR7","doi-asserted-by":"publisher","first-page":"3874","DOI":"10.1118\/1.2349696","volume":"33","author":"PJ Keall","year":"2006","unstructured":"Keall PJ, Mageras GS, Balter JM, et al. The management of respiratory motion in radiation oncology report of AAPM task group 76. Med Phys. 2006;33:3874\u2013900. https:\/\/doi.org\/10.1118\/1.2349696.","journal-title":"Med Phys"},{"key":"1005_CR8","unstructured":"Japanese Society for Radiation Oncology. Guidelines of SBRT [author\u2019s translation]. https:\/\/www.jastro.or.jp\/customer\/guideline\/2016\/10\/SRT.pdf. Accessed Jul 15, 2025."},{"key":"1005_CR9","doi-asserted-by":"publisher","first-page":"292","DOI":"10.5603\/NJO.2017.0048","volume":"67","author":"M Adamczyk","year":"2017","unstructured":"Adamczyk M, Piotrowski T. Respiratory motion and its compensation possibilities in the modern external beam radiotherapy of lung cancer. Nowotwory J Oncol. 2017;67:292\u201396. https:\/\/doi.org\/10.5603\/NJO.2017.0048.","journal-title":"Nowotwory J Oncol"},{"key":"1005_CR10","doi-asserted-by":"publisher","first-page":"932","DOI":"10.1016\/S0360-3016(01)01716-3","volume":"51","author":"FJ Lagerwaard","year":"2001","unstructured":"Lagerwaard FJ, Van Sornsen de Koste JR, Nijssen-Visser MR, et al. Multiple \u2018slow\u2019 CT scans for incorporating lung tumor mobility in radiotherapy planning. Int J Radiat Oncol Biol Phys. 2001;51:932\u201337. https:\/\/doi.org\/10.1016\/S0360-3016(01)01716-3.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1005_CR11","doi-asserted-by":"publisher","first-page":"297","DOI":"10.6009\/jjrt.64.297","volume":"64","author":"M Tachibana","year":"2008","unstructured":"Tachibana M. Total breathing phase scan (slow scan) method in the free breathing state by multi-detector-row computed tomography scanner in radiotherapy planning. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2008;64:297\u2013305. https:\/\/doi.org\/10.6009\/jjrt.64.297.","journal-title":"Nihon Hoshasen Gijutsu Gakkai Zasshi"},{"key":"1005_CR12","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1186\/1748-717X-9-106","volume":"9","author":"SS Jang","year":"2014","unstructured":"Jang SS, Huh GJ, Park SY, et al. Reconstitution of internal target volumes by combining four-dimensional computed tomography and a modified slow computed tomography scan in stereotactic body radiotherapy planning for lung cancer. Radiat Oncol. 2014;9:106. https:\/\/doi.org\/10.1186\/1748-717X-9-106.","journal-title":"Radiat Oncol"},{"key":"1005_CR13","doi-asserted-by":"publisher","first-page":"1283","DOI":"10.1016\/j.ijrobp.2004.07.665","volume":"60","author":"RW Underberg","year":"2004","unstructured":"Underberg RW, Lagerwaard FJ, Cuijpers JP, Slotman BJ, van S\u00f6rnsen de Koste JR, Senan S. Four-dimensional CT scans for treatment planning in stereotactic radiotherapy for stage I lung cancer. Int J Radiat Oncol Biol Phys. 2004;60:1283\u201390. https:\/\/doi.org\/10.1016\/j.ijrobp.2004.07.665.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1005_CR14","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1120\/jacmp.v16i2.4949","volume":"16","author":"SJ Castillo","year":"2015","unstructured":"Castillo SJ, Castillo R, Castillo E, et al. Evaluation of 4D CT acquisition methods designed to reduce artifacts. J Appl Clin Med Phys. 2015;16:23\u201332. https:\/\/doi.org\/10.1120\/jacmp.v16i2.4949.","journal-title":"J Appl Clin Med Phys"},{"key":"1005_CR15","doi-asserted-by":"publisher","first-page":"1250","DOI":"10.1016\/j.ijrobp.2008.06.1937","volume":"72","author":"T Yamamoto","year":"2008","unstructured":"Yamamoto T, Langner U, Loo BW Jr, Shen J, Keall PJ. Retrospective analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients. Int J Radiat Oncol Biol Phys. 2008;72:1250\u201358. https:\/\/doi.org\/10.1016\/j.ijrobp.2008.06.1937.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1005_CR16","doi-asserted-by":"publisher","first-page":"1254","DOI":"10.1118\/1.3298007","volume":"37","author":"J Sarker","year":"2010","unstructured":"Sarker J, Chu A, Mui K, et al. Variations in tumor size and position due to irregular breathing in 4d-ct: a simulation study. Med Phys. 2010;37:1254\u201360. https:\/\/doi.org\/10.1118\/1.3298007.","journal-title":"Med Phys"},{"key":"1005_CR17","doi-asserted-by":"publisher","first-page":"736","DOI":"10.6009\/jjrt.2019_JSRT_75.8.736","volume":"75","author":"N Tsuda","year":"2019","unstructured":"Tsuda N, Mitsui K, Oda S. Evaluation for resolution property of CT image with half-reconstruction algorithm. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2019;75:736\u201346. https:\/\/doi.org\/10.6009\/jjrt.2019_JSRT_75.8.736.","journal-title":"Nihon Hoshasen Gijutsu Gakkai Zasshi"},{"key":"1005_CR18","doi-asserted-by":"publisher","first-page":"760","DOI":"10.1186\/s12885-018-4647-4","volume":"18","author":"KJ Borm","year":"2018","unstructured":"Borm KJ, Oechsner M, Wiegandt M, Hofmeister A, Combs SE, Duma MN. Moving targets in 4D-CTs versus MIP and AIP: comparison of patients data to phantom data. BMC Cancer. 2018;18:760. https:\/\/doi.org\/10.1186\/s12885-018-4647-4.","journal-title":"BMC Cancer"},{"key":"1005_CR19","doi-asserted-by":"publisher","first-page":"297","DOI":"10.2307\/1932409","volume":"26","author":"LR Dice","year":"1945","unstructured":"Dice LR. Measures of the amount of ecologic association between species. Ecology. 1945;26:297\u2013302. https:\/\/doi.org\/10.2307\/1932409.","journal-title":"Ecology"},{"key":"1005_CR20","doi-asserted-by":"publisher","first-page":"e43","DOI":"10.1002\/mp.12256","volume":"44","author":"KK Brock","year":"2017","unstructured":"Brock KK, Mutic S, McNutt TR, Li H, Kessler ML. Use of image registration and fusion algorithms and techniques in radiotherapy: report of the AAPM radiation therapy committee task group 132. Med Phys. 2017;44:e43\u201376. https:\/\/doi.org\/10.1002\/mp.12256.","journal-title":"Med Phys"},{"key":"1005_CR21","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1038\/bmt.2012.244","volume":"48","author":"Y Kanda","year":"2013","unstructured":"Kanda Y. Investigation of the freely available easy-to-use software \u2018EZR\u2019 for medical statistics. Bone Marrow Transpl. 2013;48:452\u20138. https:\/\/doi.org\/10.1038\/bmt.2012.244.","journal-title":"Bone Marrow Transpl"},{"key":"1005_CR22","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1016\/j.radonc.2009.12.028","volume":"95","author":"AV Louie","year":"2010","unstructured":"Louie AV, Rodrigues G, Olsthoorn J, et al. Inter-observer and intra-observer reliability for lung cancer target volume delineation in the 4D-CT era. Radiother Oncol. 2010;95:166\u201371. https:\/\/doi.org\/10.1016\/j.radonc.2009.12.028.","journal-title":"Radiother Oncol"},{"key":"1005_CR23","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1007\/s00411-022-01009-w","volume":"62","author":"Y Yedekci","year":"2023","unstructured":"Yedekci Y, Hurmuz P, Ozyigit G. Effects of reconstruction methods on dose distribution for lung stereotactic body radiotherapy treatment plans. Radiat Environ Biophys. 2023;62:107\u201315. https:\/\/doi.org\/10.1007\/s00411-022-01009-w.","journal-title":"Radiat Environ Biophys"},{"key":"1005_CR24","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1016\/j.meddos.2024.11.001","volume":"50","author":"S Hinai","year":"2025","unstructured":"Hinai S, Usui K, Obara Y, et al. Effectiveness of 4-dimensional maximum intensity projection (4D-MIP) for respiratory motion management with uncertain interobserver delineation. Med Dosim. 2025;50:141\u201347. https:\/\/doi.org\/10.1016\/j.meddos.2024.11.001.","journal-title":"Med Dosim"},{"key":"1005_CR25","doi-asserted-by":"publisher","first-page":"1433","DOI":"10.1097\/JTO.0b013e31818e5db7","volume":"3","author":"R Muirhead","year":"2008","unstructured":"Muirhead R, McNee SG, Featherstone C, Moore K, Muscat S. Use of maximum intensity projections (MIPs) for target outlining in 4DCT radiotherapy planning. J Thorac Oncol. 2008;3:1433\u20138. https:\/\/doi.org\/10.1097\/JTO.0b013e31818e5db7.","journal-title":"J Thorac Oncol"},{"key":"1005_CR26","doi-asserted-by":"publisher","first-page":"572","DOI":"10.1007\/s11604-016-0560-4","volume":"34","author":"F Baba","year":"2016","unstructured":"Baba F, Tanaka S, Nonogaki Y, et al. Effects of audio coaching and visual feedback on the stability of respiration during radiotherapy. Jpn J Radiol. 2016;34:572\u20138. https:\/\/doi.org\/10.1007\/s11604-016-0560-4.","journal-title":"Jpn J Radiol"},{"key":"1005_CR27","doi-asserted-by":"publisher","first-page":"822","DOI":"10.1016\/S0360-3016(02)02803-1","volume":"53","author":"Y Seppenwoolde","year":"2002","unstructured":"Seppenwoolde Y, Shirato H, Kitamura K, et al. Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys. 2002;53:822\u201334. https:\/\/doi.org\/10.1016\/S0360-3016(02)02803-1.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1005_CR28","doi-asserted-by":"publisher","first-page":"8927290","DOI":"10.1155\/2018\/8927290","volume":"2018","author":"C Yang","year":"2018","unstructured":"Yang C, Liu R, Ming X, Liu N, Guan Y, Feng Y. Thoracic organ doses and cancer risk from low pitch helical 4-dimensional computed tomography scans. BioMed Res Int. 2018;2018:8927290. https:\/\/doi.org\/10.1155\/2018\/8927290.","journal-title":"BioMed Res Int"}],"container-title":["Radiological Physics and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-026-01005-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12194-026-01005-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-026-01005-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,28]],"date-time":"2026-02-28T07:12:00Z","timestamp":1772262720000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12194-026-01005-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,9]]},"references-count":28,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,3]]}},"alternative-id":["1005"],"URL":"https:\/\/doi.org\/10.1007\/s12194-026-01005-5","relation":{},"ISSN":["1865-0333","1865-0341"],"issn-type":[{"value":"1865-0333","type":"print"},{"value":"1865-0341","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,9]]},"assertion":[{"value":"9 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 December 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 December 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 January 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was approved by the Ethics Committee of Nihon University Itabashi Hospital (number RK-250610-4).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Opt-out consent was performed.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}