{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,7]],"date-time":"2026-06-07T06:27:52Z","timestamp":1780813672762,"version":"3.54.1"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T00:00:00Z","timestamp":1770163200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T00:00:00Z","timestamp":1770163200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol Phys Technol"],"published-print":{"date-parts":[[2026,3]]},"DOI":"10.1007\/s12194-026-01017-1","type":"journal-article","created":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T06:16:42Z","timestamp":1770185802000},"page":"321-333","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Enhancement of electron beam conformity in MRI-guided radiotherapy with parallel magnetic fields: a Monte Carlo analysis"],"prefix":"10.1007","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6184-7203","authenticated-orcid":false,"given":"Mohammed","family":"Rezzoug","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yassine","family":"Oulhouq","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Omar","family":"Hamzaoui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mustapha","family":"Zerfaoui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdeslem","family":"Rrhioua","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dikra","family":"Bakari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,2,4]]},"reference":[{"issue":"1","key":"1017_CR1","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1186\/s13014-023-02221-8","volume":"18","author":"X Liu","year":"2023","unstructured":"Liu X, Li Z, Yin Y. Clinical application of MR-Linac in tumor radiotherapy: a systematic review. Radiat Oncol. 2023;18(1):52.","journal-title":"Radiat Oncol"},{"key":"1017_CR2","doi-asserted-by":"crossref","unstructured":"Benitez CM, Chuong MD, K\u00fcnzel LA, Thorwarth D. MRI-guided adaptive radiation therapy. Semin Radiat Oncol 2024;34(1):84-91","DOI":"10.1016\/j.semradonc.2023.10.013"},{"issue":"1","key":"1017_CR3","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1002\/mp.17454","volume":"52","author":"H Fuchs","year":"2025","unstructured":"Fuchs H, Palmans H, Heilemann G, Zuschlag D, Georg D, Kuess P. Dosimetry in mrgpt: impact of magnetic fields on TLD dose response during proton irradiation. Med Phys. 2025;52(1):633\u20139.","journal-title":"Med Phys"},{"issue":"8Part1","key":"1017_CR4","doi-asserted-by":"publisher","first-page":"4915","DOI":"10.1118\/1.4959785","volume":"43","author":"DJ O\u2019Brien","year":"2016","unstructured":"O\u2019Brien DJ, Roberts DA, Ibbott GS, Sawakuchi GO. Reference dosimetry in magnetic fields: formalism and ionization chamber correction factors. Med Phys. 2016;43(8Part1):4915\u201327.","journal-title":"Med Phys"},{"issue":"2","key":"1017_CR5","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1016\/j.radonc.2017.09.036","volume":"125","author":"CL Tseng","year":"2017","unstructured":"Tseng CL, Eppinga W, Seravalli E, Hackett S, Brand E, Ruschin M, Sahgal A. Dosimetric feasibility of the hybrid magnetic resonance imaging (MRI)-linac system (MRL) for brain metastases: the impact of the magnetic field. Radiother Oncol. 2017;125(2):273\u20139.","journal-title":"Radiother Oncol"},{"issue":"7","key":"1017_CR6","doi-asserted-by":"publisher","first-page":"1363","DOI":"10.1088\/0031-9155\/50\/7\/002","volume":"50","author":"AJ Raaijmakers","year":"2005","unstructured":"Raaijmakers AJ, Raaymakers BW, Lagendijk JJ. Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose increase at tissue\u2013air interfaces in a lateral magnetic field due to returning electrons. Phys Med Biol. 2005;50(7):1363.","journal-title":"Phys Med Biol"},{"issue":"17","key":"1017_CR7","doi-asserted-by":"publisher","first-page":"175013","DOI":"10.1088\/1361-6560\/ab325b","volume":"64","author":"S H\u00f6fel","year":"2019","unstructured":"H\u00f6fel S, Fix MK, Zwicker F, Sterpin E, Drescher M. EPR imaging of magnetic field effects on radiation dose distributions around millimeter-size air cavities. Phys Med Biol. 2019;64(17):175013.","journal-title":"Phys Med Biol"},{"issue":"3","key":"1017_CR8","doi-asserted-by":"publisher","first-page":"035012","DOI":"10.1088\/1361-6560\/aafab4","volume":"64","author":"A L\u00fchr","year":"2019","unstructured":"L\u00fchr A, Burigo LN, Gantz S, Schellhammer SM, Hoffmann AL. Proton beam electron return effect: Monte Carlo simulations and experimental verification. Phys Med Biol. 2019;64(3):035012.","journal-title":"Phys Med Biol"},{"issue":"3","key":"1017_CR9","doi-asserted-by":"publisher","first-page":"1258","DOI":"10.1002\/mp.13954","volume":"47","author":"JM Andreozzi","year":"2020","unstructured":"Andreozzi JM, Br\u016f\u017ea P, Cammin J, Pogue BW, Gladstone DJ, Green O. Optical imaging method to quantify Spatial dose variation due to the electron return effect in an MR-linac. Med Phys. 2020;47(3):1258\u201367.","journal-title":"Med Phys"},{"key":"1017_CR10","doi-asserted-by":"publisher","first-page":"136","DOI":"10.3389\/fonc.2020.00136","volume":"10","author":"U Jelen","year":"2020","unstructured":"Jelen U, Dong B, Begg J, Roberts N, Whelan B, Keall P, Liney G. Dosimetric optimization and commissioning of a high field inline MRI-linac. Front Oncol. 2020;10:136.","journal-title":"Front Oncol"},{"key":"1017_CR11","doi-asserted-by":"publisher","unstructured":"Zhou J, Jiang W, Lu C, Liu G, Wu Z, Wang M, Song F. The design and analysis of a novel multistage depressed collector for gyro-TWT. Phys Plasmas. 2024;31(5): 053107. https:\/\/doi.org\/10.1063\/5.0209628","DOI":"10.1063\/5.0209628"},{"issue":"7","key":"1017_CR12","doi-asserted-by":"publisher","first-page":"4174","DOI":"10.1118\/1.3600695","volume":"38","author":"DE Constantin","year":"2011","unstructured":"Constantin DE, Fahrig R, Keall PJ. A study of the effect of in-line and perpendicular magnetic fields on beam characteristics of electron guns in medical linear accelerators. Med Phys. 2011;38(7):4174\u201385.","journal-title":"Med Phys"},{"issue":"8","key":"1017_CR13","doi-asserted-by":"publisher","first-page":"e18052","DOI":"10.1002\/mp.18052","volume":"52","author":"AU Khan","year":"2025","unstructured":"Khan AU. Impact of magnetic fields on small field dosimetry for parallel MR-linacs. Med Phys. 2025;52(8):e18052.","journal-title":"Med Phys"},{"key":"1017_CR14","doi-asserted-by":"publisher","first-page":"170505","DOI":"10.1016\/j.nima.2025.170505","volume":"1076","author":"M Hashemizadeh","year":"2025","unstructured":"Hashemizadeh M, Tarahomi F, Zabihzadeh M, Alvani P. Dose perturbation calculation of 9\u00a0MeV electron beams in the presence of a 1.5 Tesla longitudinal magnetic field and different inhomogeneities: A Monte Carlo study. Nucl Instrum Methods Phys Res Sect A. 2025;1076:170505.","journal-title":"Nucl Instrum Methods Phys Res Sect A"},{"key":"1017_CR15","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/j.ejmp.2020.09.001","volume":"78","author":"R Kueng","year":"2020","unstructured":"Kueng R, Oborn BM, Roberts NF, Causer T, Stampanoni MFM, Manser P, Fix MK. Towards MR-guided electron therapy: measurement and simulation of clinical electron beams in magnetic fields. Physica Med. 2020;78:83\u201392.","journal-title":"Physica Med"},{"issue":"6Part25","key":"1017_CR16","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1118\/1.4889201","volume":"41","author":"A Rubinstein","year":"2014","unstructured":"Rubinstein A, Guindani M, Followill D, Melancon A, Hazle J, Court L. MO-G\u2010BRF\u201009: investigating magnetic field dose effects in mice: A Monte Carlo study. Med Phys. 2014;41(6Part25):436\u2013436.","journal-title":"Med Phys"},{"issue":"6Part1","key":"1017_CR17","doi-asserted-by":"publisher","first-page":"064301","DOI":"10.1118\/1.4871617","volume":"41","author":"D Sarrut","year":"2014","unstructured":"Sarrut D, Bardi\u00e8s M, Boussion N, Freud N, Jan S, L\u00e9tang JM, Buvat I. A review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications. Med Phys. 2014;41(6Part1):064301.","journal-title":"Med Phys"},{"key":"1017_CR18","doi-asserted-by":"publisher","first-page":"110859","DOI":"10.1016\/j.radphyschem.2023.110859","volume":"207","author":"M Rezzoug","year":"2023","unstructured":"Rezzoug M, Zerfaoui M, Oulhouq Y, Rrhioua A, Didi S, Hamal M, Moussa A. Varian clinac 2100 linear accelerator simulation employing PRIMO phase space model. Radiat Phys Chem. 2023;207:110859.","journal-title":"Radiat Phys Chem"},{"issue":"17","key":"1017_CR19","doi-asserted-by":"publisher","first-page":"3033","DOI":"10.1088\/0031-9155\/47\/17\/301","volume":"47","author":"P Andreo","year":"2002","unstructured":"Andreo P, Huq MS, Westermark M, Song H, Tilikidis A, DeWerd L, Shortt K. Protocols for the dosimetry of high-energy photon and electron beams: a comparison of the IAEA TRS-398 and previous international codes of practice. Phys Med Biol. 2002;47(17):3033.","journal-title":"Phys Med Biol"},{"issue":"8Part1","key":"1017_CR20","doi-asserted-by":"publisher","first-page":"4797","DOI":"10.1118\/1.4959534","volume":"43","author":"X Chen","year":"2016","unstructured":"Chen X, Prior P, Chen GP, Schultz CJ, Li XA. Dose effects of 1.5 T transverse magnetic field on tissue interfaces in MRI-guided radiotherapy. Med Phys. 2016;43(8Part1):4797\u2013802.","journal-title":"Med Phys"},{"key":"1017_CR21","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1016\/j.radphyschem.2018.12.016","volume":"157","author":"A Mahmoudi","year":"2019","unstructured":"Mahmoudi A, Geraily G, Shirazi A. Penumbra reduction technique and factors affecting it in radiotherapy machines\u2013Review study. Radiat Phys Chem. 2019;157:22\u20137.","journal-title":"Radiat Phys Chem"}],"container-title":["Radiological Physics and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-026-01017-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12194-026-01017-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-026-01017-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,28]],"date-time":"2026-02-28T07:12:03Z","timestamp":1772262723000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12194-026-01017-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,4]]},"references-count":21,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,3]]}},"alternative-id":["1017"],"URL":"https:\/\/doi.org\/10.1007\/s12194-026-01017-1","relation":{},"ISSN":["1865-0333","1865-0341"],"issn-type":[{"value":"1865-0333","type":"print"},{"value":"1865-0341","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,4]]},"assertion":[{"value":"19 July 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 December 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 January 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 February 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Not applicable. This study did not involve human participants or animals.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Preliminary findings from this study were not previously published or presented in conference proceedings.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}]}}