{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T06:58:27Z","timestamp":1781074707628,"version":"3.54.1"},"reference-count":43,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T00:00:00Z","timestamp":1772150400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T00:00:00Z","timestamp":1772150400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol Phys Technol"],"published-print":{"date-parts":[[2026,6]]},"DOI":"10.1007\/s12194-026-01033-1","type":"journal-article","created":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T06:10:27Z","timestamp":1772172627000},"page":"651-665","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Establishment of local diagnostic reference levels for planning CT in adult and pediatric radiotherapy patients in 18 Japanese university hospitals"],"prefix":"10.1007","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2305-1121","authenticated-orcid":false,"given":"Hideki","family":"Obara","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kiyokazu","family":"Sato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Satoshi","family":"Abe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroki","family":"Katayama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takahiro","family":"Ushijima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takuro","family":"Okumura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuki","family":"Yuasa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshinobu","family":"Shimohigashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hironori","family":"Kojima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taka-aki","family":"Hirose","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mizuho","family":"Saito","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takashi","family":"Iimori","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masanobu","family":"Terui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,2,27]]},"reference":[{"key":"1033_CR1","doi-asserted-by":"publisher","first-page":"864","DOI":"10.1093\/jrr\/rrae078","volume":"65","author":"S Okazaki","year":"2024","unstructured":"Okazaki S, Murata M, Kitamoto Y. Current situation and rends of radiation therapy in Japan based on the National Database Open Data. J Radiat Res. 2024;65:864\u201371. https:\/\/doi.org\/10.1093\/jrr\/rrae078.","journal-title":"J Radiat Res"},{"key":"1033_CR2","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1016\/j.radonc.2016.02.016","volume":"119","author":"JM Borras","year":"2016","unstructured":"Borras JM, Lievens Y, Barton M, et al. How many new cancer patients in EUROPE will require radiotherapy by 2025? An ESTRO-HERO analysis. Radiother Oncol. 2016;119:5\u201311. https:\/\/doi.org\/10.1016\/j.radonc.2016.02.016.","journal-title":"Radiother Oncol"},{"key":"1033_CR3","doi-asserted-by":"publisher","first-page":"963","DOI":"10.1158\/1055-9965.EPI-16-1023","volume":"26","author":"AK Bryant","year":"2017","unstructured":"Bryant AK, Banegas MP, Martinez ME, et al. Trends in radiation therapy among cancer survivors in the United States, 2000\u20132030. Cancer Epidemiol Biomarkers Prev. 2017;26:963\u201370. https:\/\/doi.org\/10.1158\/1055-9965.EPI-16-1023.","journal-title":"Cancer Epidemiol Biomarkers Prev"},{"key":"1033_CR4","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1016\/S0140-6736(04)15433-0","volume":"363","author":"A Berrington de Gonzalez","year":"2004","unstructured":"Berrington de Gonzalez A, Darby S. Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries. Lancet. 2004;363:345\u201351. https:\/\/doi.org\/10.1016\/S0140-6736(04)15433-0.","journal-title":"Lancet"},{"key":"1033_CR5","doi-asserted-by":"publisher","first-page":"437","DOI":"10.3322\/caac.21689","volume":"71","author":"K Wang","year":"2021","unstructured":"Wang K, Tepper JE. Radiation therapy-associated toxicity: etiology, management, and prevention. CA Cancer J Clin. 2021;71:437\u201354. https:\/\/doi.org\/10.3322\/caac.21689.","journal-title":"CA Cancer J Clin"},{"key":"1033_CR6","doi-asserted-by":"publisher","DOI":"10.61092\/iaea.u2pu-60vm","volume-title":"Radiation protection and safety of radiation sources: international basic safety standards","author":"International Atomic Energy Agency (IAEA)","year":"2014","unstructured":"International Atomic Energy Agency (IAEA). Radiation protection and safety of radiation sources: international basic safety standards. IAEA Safety Standards Series. Vienna: IAEA; 2014. https:\/\/doi.org\/10.61092\/iaea.u2pu-60vm."},{"key":"1033_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/0146645317717209","volume":"46","author":"E Vano","year":"2017","unstructured":"Vano E, Miller DL, Martin CJ, et al. ICRP publication 135: Diagnostic reference levels in medical imaging. Ann ICRP. 2017;46:1\u2013144. https:\/\/doi.org\/10.1177\/0146645317717209.","journal-title":"Ann ICRP"},{"key":"1033_CR8","first-page":"1","volume-title":"Recommendations of the International Commission on Radiological Protection. ICRP Publication 26. Ann. ICRP","author":"International Commission on Radiological Protection (ICRP)","year":"1977","unstructured":"International Commission on Radiological Protection (ICRP). Recommendations of the International Commission on Radiological Protection. ICRP Publication 26. Ann. ICRP. Ottawa: ICRP; 1977. p. 1."},{"key":"1033_CR9","doi-asserted-by":"crossref","unstructured":"ICRP. 1990 Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. Ann. ICRP. Ottawa: ICRP; 1991;21.","DOI":"10.1016\/0146-6453(91)90066-P"},{"key":"1033_CR10","doi-asserted-by":"publisher","unstructured":"ICRP. The 2007 Recommendations of the International Commission on Radiological Protection, Ottawa. ICRP Publication 103. Ann. ICRP. ICRP; 2007. p. 37. https:\/\/doi.org\/10.1016\/j.icrp.2007.10.003.","DOI":"10.1016\/j.icrp.2007.10.003"},{"key":"1033_CR11","doi-asserted-by":"crossref","unstructured":"ICRP. Radiological Protection and Safety in Medicine. ICRP Publication 73. Ann. ICRP. Ottawa: ICRP. 1996;26.","DOI":"10.1016\/S0146-6453(00)89195-2"},{"key":"1033_CR12","first-page":"31","volume-title":"Radiation and your patient \u2013 A Guide for Medical Practitioners. ICRP Supporting Guidance 2. Ann. ICRP","author":"ICRP","year":"2001","unstructured":"ICRP. Radiation and your patient \u2013 A Guide for Medical Practitioners. ICRP Supporting Guidance 2. Ann. ICRP. Ottawa: ICRP; 2001. p. 31."},{"key":"1033_CR13","unstructured":"Ministry of Health, Labour and Welfare, Enforcement of the Ministerial Ordinance Partially Amending the Enforcement Regulations of the Medical Care Act. Notification No. 0312-7. 12 Mar 2019. https:\/\/www.mhlw.go.jp\/stf\/seisakunitsuite\/bunya\/0000137802_00005.html. Accessed 26 Feb 2025."},{"key":"1033_CR14","unstructured":"Japanese Society for Radiation Oncology (JASTRO), Medical Safety Committee, Subcommittee on Image-Guided Radiation Therapy. Response of the Radiation Oncology Department to the Partial Revision of the Enforcement Regulations of the Medical Care Act. JASTRO. 16. May 2020. https:\/\/www.jastro.or.jp\/medicalpersonnel\/safety\/20200518.pdf. Accessed 26 Feb 2025."},{"key":"1033_CR15","unstructured":"Japan Network for Research and Information on Medical Exposure (J-RIME), Japan Radiological Physics Society (JRP), Japan Health Physics Society (JHPS), et al. National diagnostic reference levels in Japan et al. (2020) -Japan DRLs 2020-. 2020. https:\/\/j-rime.qst.go.jp\/report\/DRL2020_Engver.pdf. Accessed 27 Feb 2025."},{"key":"1033_CR16","unstructured":"J-RIME, National Diagnostic Reference Levels in Japan. (2025) - Japan DRLs 2025-. https:\/\/j-rime.qst.go.jp\/report\/JapanDRLs2025_en.pdf. Accessed 11 Jul 2025."},{"key":"1033_CR17","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1093\/jrr\/rrad098","volume":"65","author":"S Kito","year":"2024","unstructured":"Kito S, Suda Y, Tanabe S, et al. Radiological imaging protection: a study on imaging dose used while planning computed tomography for external radiotherapy in Japan. J Radiat Res. 2024;65:159\u201367. https:\/\/doi.org\/10.1093\/jrr\/rrad098.","journal-title":"J Radiat Res"},{"key":"1033_CR18","doi-asserted-by":"crossref","unstructured":"ICRP. Managing patient dose in computed tomography. ICRP Publication 87. Ann. ICRP. Ottawa: ICRP. 2000;30.","DOI":"10.1016\/S0146-6453(01)00049-5"},{"key":"1033_CR19","unstructured":"Dixon RL, Anderson JA, Bakalyar DM, et al. Comprehensive Methodology for the Evaluation of Radiation Dose in X-ray Computed Tomography. American Association of Physicists in Medicine (AAPM) Task Group 111, Report of AAPM Task Group 111: The Future of CT Dosimetry. American Association of Physicists in Medicine; 2010."},{"key":"1033_CR20","unstructured":"International Electrotechnical Commission (IEC). Medical electrical equipment - Part 2\u201344: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography. IEC 60601-2-44, 3rd edition. Geneva:IEC; 2009."},{"key":"1033_CR21","unstructured":"IEC. Medical electrical equipment - Part 2\u201344: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography. IEC 60601-2-44:2009\u2009+\u2009AMD1:2012 CSV, 3rd edition (consolidated version). Geneva:IEC; 2012."},{"key":"1033_CR22","doi-asserted-by":"publisher","unstructured":"Boone JM, Strauss KJ, Cody DD et al. Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations: Report of AAPM Task Group 204. College Park:AAPM; 2011. https:\/\/doi.org\/10.37206\/143","DOI":"10.37206\/143"},{"key":"1033_CR23","doi-asserted-by":"publisher","first-page":"1166","DOI":"10.6009\/jjrt.2014_jsrt_70.10.1166","volume":"70","author":"K Yokomachi","year":"2014","unstructured":"Yokomachi K, Nishimaru E, Fujioka C, et al. Effects of differences in head holder on image quality and radiation dose in head CT. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2014;70:1166\u201372. https:\/\/doi.org\/10.6009\/jjrt.2014_jsrt_70.10.1166.","journal-title":"Nihon Hoshasen Gijutsu Gakkai Zasshi"},{"key":"1033_CR24","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1093\/jrr\/rraa088","volume":"62","author":"H Okamoto","year":"2021","unstructured":"Okamoto H, Kito S, Tohyama N, et al. Radiation protection in radiological imaging: a survey of imaging modalities used in Japanese institutions for verifying applicator placements in high-dose-rate brachytherapy. J Radiat Res. 2021;62:58\u201366. https:\/\/doi.org\/10.1093\/jrr\/rraa088.","journal-title":"J Radiat Res"},{"key":"1033_CR25","doi-asserted-by":"publisher","first-page":"20160428","DOI":"10.1259\/bjr.20160428","volume":"89","author":"S O\u2019 Connor","year":"2016","unstructured":"O\u2019 Connor S, Mc Ardle O, Mullaney L, et al. Establishment of national diagnostic reference levels for breast cancer CT protocols in radiation therapy. Br J Radiol. 2016;89:20160428. https:\/\/doi.org\/10.1259\/bjr.20160428.","journal-title":"Br J Radiol"},{"key":"1033_CR26","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1016\/j.rpor.2018.07.012","volume":"23","author":"C Clerkin","year":"2018","unstructured":"Clerkin C, Brennan S, Mullaney LM, et al. Establishment of national diagnostic reference levels (DRLs) for radiotherapy localisation computer tomography of the head and neck. Rep Pract Oncol Radiother. 2018;23:407\u201312. https:\/\/doi.org\/10.1016\/j.rpor.2018.07.012.","journal-title":"Rep Pract Oncol Radiother"},{"key":"1033_CR27","doi-asserted-by":"publisher","first-page":"185008","DOI":"10.1088\/1361-6560\/aacc87","volume":"10","author":"TJ Wood","year":"2018","unstructured":"Wood TJ, Davis AT, Earley J, et al. IPEM topical report: the first UK survey of dose indices from radiotherapy treatment planning computed tomography scans for adult patients. Phys Med Biol. 2018;10:63:185008. https:\/\/doi.org\/10.1088\/1361-6560\/aacc87.","journal-title":"Phys Med Biol"},{"key":"1033_CR28","unstructured":"GOV.UK. National Diagnostic Reference Levels from 8 July 2025. https:\/\/www.gov.uk\/government\/publications\/diagnostic-radiology-national-diagnostic-reference-levels-ndrls\/ndrl. Accessed 13 Jul 2025."},{"key":"1033_CR29","doi-asserted-by":"publisher","first-page":"1","DOI":"10.12688\/f1000research.110966.2","volume":"11","author":"S Rao","year":"2022","unstructured":"Rao S, Kadavigere R, Sharan K, et al. Establishment of diagnostic reference level and radiation dose variation in head & neck and pelvis treatment planning in radiation therapy computed tomography. F1000Res. 2022;11:1\u201312. https:\/\/doi.org\/10.12688\/f1000research.110966.2.","journal-title":"F1000Res"},{"key":"1033_CR30","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1016\/j.ejmp.2022.03.001","volume":"96","author":"A Bo\u017eani\u0107","year":"2022","unstructured":"Bo\u017eani\u0107 A, \u0160egota D, Dundara Debeljuh D, et al. National reference levels of CT procedures dedicated for treatment planning in radiation oncology. Phys Med. 2022;96:123\u201329. https:\/\/doi.org\/10.1016\/j.ejmp.2022.03.001.","journal-title":"Phys Med"},{"key":"1033_CR31","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.ejrad.2020.108979","volume":"127","author":"N Zalokar","year":"2020","unstructured":"Zalokar N, ZagerMarcius V, Mekis N. Establishment of national diagnostic reference levels for radiotherapy computed tomography simulation procedures in Slovenia. Eur J Radiol. 2020;127:1\u20135. https:\/\/doi.org\/10.1016\/j.ejrad.2020.108979.","journal-title":"Eur J Radiol"},{"key":"1033_CR32","doi-asserted-by":"publisher","first-page":"602","DOI":"10.1093\/rpd\/ncu363","volume":"167","author":"P Toroi","year":"2015","unstructured":"Toroi P, Kaijaluoto S, Bly R. Patient exposure levels in radiotherapy CT simulations in Finland. Radiat Prot Dosim. 2015;167:602\u20137. https:\/\/doi.org\/10.1093\/rpd\/ncu363.","journal-title":"Radiat Prot Dosim"},{"key":"1033_CR33","doi-asserted-by":"publisher","first-page":"932","DOI":"10.1016\/j.radi.2024.04.007","volume":"30","author":"R Guisantes","year":"2024","unstructured":"Guisantes R, Santos J, Ferreira AJ. Characterisation of Portuguese radiotherapy departments: Organisation, occupational exposure values and diagnostic reference levels for breast and prostate computed tomography planning. Radiography. 2024;30:932\u201337. https:\/\/doi.org\/10.1016\/j.radi.2024.04.007.","journal-title":"Radiography"},{"key":"1033_CR34","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1051\/radiopro\/2024007","volume":"59","author":"S Semghouli","year":"2024","unstructured":"Semghouli S, EI Fahssi M, Choukri A, et al. Radiation risk during thoracic CT scan for diagnostic and radiotherapy planning procedures in Hassan II, Hospital, Agadir Morocco. Radioprotection. 2024;59:123\u201330. https:\/\/doi.org\/10.1051\/radiopro\/2024007.","journal-title":"Radioprotection"},{"key":"1033_CR35","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1051\/radiopro\/2023047","volume":"59","author":"O Nhila","year":"2024","unstructured":"Nhila O, Talbi M, Youssoufi MA, et al. Establishment of local diagnostic reference levels for breast cancer CT protocols in radiotherapy in a single Moroccan center. Radioprotection. 2024;59:50\u20134. https:\/\/doi.org\/10.1051\/radiopro\/2023047.","journal-title":"Radioprotection"},{"key":"1033_CR36","doi-asserted-by":"publisher","first-page":"999","DOI":"10.61186\/ijrr.22.4.999","volume":"22","author":"E Hasanpour","year":"2024","unstructured":"Hasanpour E, Maziar A, Paydar R, et al. Establishment of regional diagnostic reference level for CT planning of breast cancer and comparing them with international values. Int J Radiat Res. 2024;22:999\u20131007. https:\/\/doi.org\/10.61186\/ijrr.22.4.999.","journal-title":"Int J Radiat Res"},{"key":"1033_CR37","doi-asserted-by":"publisher","first-page":"2762","DOI":"10.1118\/1.1609271","volume":"30","author":"S Mutic","year":"2003","unstructured":"Mutic S, Palta JR, Butker EK, et al. Quality assurance for computed-tomography simulators and the computed tomography-simulation process: Report of the AAPM Radiation Therapy Committee Task Group 66. Med Phys. 2003;30:2762\u201392. https:\/\/doi.org\/10.1118\/1.1609271.","journal-title":"Med Phys"},{"key":"1033_CR38","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1007\/s00330-011-2271-7","volume":"22","author":"A Gervaise","year":"2012","unstructured":"Gervaise A, Osemont B, Lecocq S, et al. CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT. Eur Radiol. 2012;22:295\u2013301. https:\/\/doi.org\/10.1007\/s00330-011-2271-7.","journal-title":"Eur Radiol"},{"key":"1033_CR39","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/diagnostics14090921","volume":"14","author":"S Rao","year":"2024","unstructured":"Rao S, Sharan K, Gururajarao S, et al. Advanced Computational Methods for Radiation Dose Optimization in CT. Diagnostics. 2024;14:1\u201314. https:\/\/doi.org\/10.3390\/diagnostics14090921.","journal-title":"Diagnostics"},{"key":"1033_CR40","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-023-42775-x","volume":"13","author":"K Yasui","year":"2023","unstructured":"Yasui K, Saito Y, Ito A, et al. Validation of deep learning\u2013based CT image reconstruction for treatment planning. Sci Rep. 2023;13:1\u20136. https:\/\/doi.org\/10.1038\/s41598-023-42775-x.","journal-title":"Sci Rep"},{"key":"1033_CR41","doi-asserted-by":"publisher","first-page":"1192","DOI":"10.1007\/s12194-025-00967-2","volume":"18","author":"K Yasui","year":"2025","unstructured":"Yasui K, Kasugai Y, Morishita M, et al. Dose reduction in radiotherapy treatment planning CT via deep learning\u2013based reconstruction: a single\u2013institution study. Radiol Phys Technol. 2025;18:1192\u201398. https:\/\/doi.org\/10.1007\/s12194-025-00967-2.","journal-title":"Radiol Phys Technol"},{"key":"1033_CR42","doi-asserted-by":"publisher","first-page":"e45","DOI":"10.1002\/mp.12824","volume":"45","author":"GX Ding","year":"2018","unstructured":"Ding GX, Alaei P, Curran B, et al. Image guidance doses delivered during radiotherapy: Quantification, management, and reduction: Report of the AAPM Therapy Physics Committee Task Group 180. Med Phys. 2018;45:e45\u201399. https:\/\/doi.org\/10.1002\/mp.12824.","journal-title":"Med Phys"},{"key":"1033_CR43","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1016\/j.radi.2015.08.003","volume":"22","author":"A Sanderud","year":"2015","unstructured":"Sanderud A, England A, Hogg P, et al. Radiation dose differences between thoracic radiotherapy planning CT and thoracic diagnostic CT scans. Radiography. 2015;22:107\u201311. https:\/\/doi.org\/10.1016\/j.radi.2015.08.003.","journal-title":"Radiography"}],"container-title":["Radiological Physics and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-026-01033-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12194-026-01033-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-026-01033-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T06:16:54Z","timestamp":1781072214000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12194-026-01033-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,27]]},"references-count":43,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,6]]}},"alternative-id":["1033"],"URL":"https:\/\/doi.org\/10.1007\/s12194-026-01033-1","relation":{},"ISSN":["1865-0333","1865-0341"],"issn-type":[{"value":"1865-0333","type":"print"},{"value":"1865-0341","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,27]]},"assertion":[{"value":"16 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 February 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 February 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 February 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest related to this paper.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Formal consent to publish individual participant data was not obtained for this study. The research exclusively involved the analysis of aggregated and de-identified data, and no personally identifiable information is presented in this manuscript.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Participation consent was not required for this study as it involved the analysis of pre-existing, anonymized data and did not involve any direct interaction with human subjects. An opt-out option was provided in accordance with national ethical guidelines.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"This study was approved by the Medical Ethics Committee of Hirosaki University Graduate School of Medicine (Approval No. 2023-010-1). Among the collaborating institutions, Saga University Hospital received ethical approval from its Clinical Research Ethics Review Committee (Approval No.: 2023-04-R-12), subsequent to the approval granted by the ethics committee of Hirosaki University, the institution to which the principal investigator is affiliated.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}