{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T18:02:26Z","timestamp":1787680946637,"version":"build-2784847793"},"reference-count":65,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T00:00:00Z","timestamp":1773360000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T00:00:00Z","timestamp":1773360000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol Phys Technol"],"published-print":{"date-parts":[[2026,6]]},"DOI":"10.1007\/s12194-026-01038-w","type":"journal-article","created":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T13:41:29Z","timestamp":1773409289000},"page":"421-431","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Contemporary strategies for dose optimization in pediatric congenital heart disease CT: size-specific acquisition and detector-level advances"],"prefix":"10.1007","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4164-4369","authenticated-orcid":false,"given":"Takanori","family":"Masuda","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshinori","family":"Funama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takeshi","family":"Nakaura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,13]]},"reference":[{"key":"1038_CR1","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1007\/s00247-022-05526-0","volume":"53","author":"E Nagy","year":"2023","unstructured":"Nagy E, Tschauner S, Schramek C, Sorantin E. Paediatric CT made easy. Pediatr Radiol. 2023;53:581\u20138.","journal-title":"Pediatr Radiol"},{"key":"1038_CR2","doi-asserted-by":"publisher","first-page":"1073","DOI":"10.1007\/s00247-011-2140-1","volume":"41","author":"S Don","year":"2011","unstructured":"Don S. Exposure abstracts. Pediatr Radiol. 2011;41:1073\u20134.","journal-title":"Pediatr Radiol"},{"key":"1038_CR3","unstructured":"https:\/\/ww.unscear.org\/unscear\/uploads\/documents\/unscear-reports\/UNSCEAR_2020_21_Report_Vol.I.pdf"},{"key":"1038_CR4","first-page":"1","volume":"37","author":"The 2007 Recommendations of the International Commission on Radiological Protection","year":"2007","unstructured":"The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP. 2007;37:1\u2013332.","journal-title":"Ann ICRP"},{"key":"1038_CR5","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1016\/S0140-6736(12)60815-0","volume":"380","author":"MS Pearce","year":"2012","unstructured":"Pearce MS, Salotti JA, Little MP, McHugh K, Lee C, Kim KP, et al. Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet. 2012;380:499\u2013505.","journal-title":"Lancet"},{"key":"1038_CR6","doi-asserted-by":"publisher","first-page":"f2360","DOI":"10.1136\/bmj.f2360","volume":"346","author":"JD Mathews","year":"2013","unstructured":"Mathews JD, Forsythe AV, Brady Z, Butler MW, Goergen SK, Byrnes GB, Giles GG, Wallace AB, Anderson PR, Guiver TA, McGale P, Cain TM, Dowty JG, Bickerstaffe AC, Darby SC. Cancer risk in 680,000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians. BMJ. 2013;346:f2360.","journal-title":"BMJ"},{"key":"1038_CR7","doi-asserted-by":"publisher","first-page":"3111","DOI":"10.1038\/s41591-023-02620-0","volume":"29","author":"M de Bosch Basea","year":"2023","unstructured":"de Bosch Basea M, Thierry-Chef I, Harbron R, Hauptmann M, Byrnes G, Bernier MO, et al. Risk of hematological malignancies from CT radiation exposure in children, adolescents and young adults. Nat Med. 2023;29:3111\u20139.","journal-title":"Nat Med"},{"key":"1038_CR8","doi-asserted-by":"publisher","first-page":"273","DOI":"10.2214\/AJR.07.3526","volume":"190","author":"MJ Goske","year":"2008","unstructured":"Goske MJ, Applegate KE, Boylan J, Butler PF, Callahan MJ, Coley BD, et al. The image gently campaign: working together to change practice. AJR Am J Roentgenol. 2008;190:273\u20134.","journal-title":"AJR Am J Roentgenol"},{"key":"1038_CR9","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1148\/radiol.2020202317","volume":"298","author":"SL Brady","year":"2021","unstructured":"Brady SL, Trout AT, Somasundaram E, Anton CG, Li Y, Dillman JR. Improving image quality and reducing radiation dose for pediatric CT by using deep learning reconstruction. Radiology. 2021;298:180\u20138.","journal-title":"Radiology"},{"key":"1038_CR10","doi-asserted-by":"publisher","first-page":"1421","DOI":"10.1148\/rg.2018180041","volume":"38","author":"Y Nagayama","year":"2018","unstructured":"Nagayama Y, Oda S, Nakaura T, Tsuji A, Urata J, Furusawa M, et al. Radiation dose reduction at pediatric CT: use of low tube voltage and iterative reconstruction. Radiographics. 2018;38:1421\u201340.","journal-title":"Radiographics"},{"key":"1038_CR11","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1148\/radiol.2021211241","volume":"302","author":"KM Kanal","year":"2022","unstructured":"Kanal KM, Butler PF, Chatfield MB, Wells J, Samei E, Simanowith M, et al. U.S. diagnostic reference levels and achievable doses for 10 pediatric CT examinations. Radiology. 2022;302:164\u201374.","journal-title":"Radiology"},{"key":"1038_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/0146645317717209","volume":"46","author":"E Va\u00f1\u00f3","year":"2017","unstructured":"Va\u00f1\u00f3 E, Miller DL, Martin CJ, Rehani MM, Kang K, Rosenstein M, et al. ICRP publication 135: diagnostic reference levels in medical imaging. Ann ICRP. 2017;46:1\u2013144.","journal-title":"Ann ICRP"},{"key":"1038_CR13","unstructured":"European guidelines on diagnostic reference levels for paediatric imaging. Publications Office; 2018."},{"key":"1038_CR14","unstructured":"https:\/\/j-rime.qst.go.jp\/report\/JapanDRLs2025_ja.pdf"},{"key":"1038_CR15","first-page":"58","volume":"8","author":"V Rajaraman","year":"2020","unstructured":"Rajaraman V, Ponnusamy M, Halanaik D. Size specific dose estimate (SSDE) for estimating patient dose from CT used in myocardial perfusion SPECT\/CT. Asia Ocean J Nucl Med Biol. 2020;8:58\u201363.","journal-title":"Asia Ocean J Nucl Med Biol"},{"key":"1038_CR16","first-page":"6","volume":"2014","author":"C McCollough","year":"2014","unstructured":"McCollough C, Bakalyar DM, Bostani M, Brady S, Boedeker K, Boone JM, et al. Use of water equivalent diameter for calculating patient size and size-specific dose estimates (SSDE) in CT: the report of AAPM task group 220. AAPM Rep. 2014;2014:6\u201323.","journal-title":"AAPM Rep"},{"key":"1038_CR17","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1002\/acm2.12223","volume":"19","author":"CS Burton","year":"2018","unstructured":"Burton CS, Szczykutowicz TP. Evaluation of AAPM reports 204 and 220: estimation of effective diameter, water-equivalent diameter, and ellipticity ratios for chest, abdomen, pelvis, and head CT scans. J Appl Clin Med Phys. 2018;19:228\u201338.","journal-title":"J Appl Clin Med Phys"},{"key":"1038_CR18","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1148\/radiol.2015141507","volume":"279","author":"JV Spearman","year":"2016","unstructured":"Spearman JV, Schoepf UJ, Rottenkolber M, Driesser I, Canstein C, Thierfelder KM, et al. Effect of automated attenuation-based tube voltage selection on radiation dose at CT: an observational study on a global scale. Radiology. 2016;279:167\u201374.","journal-title":"Radiology"},{"key":"1038_CR19","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20170079","volume":"90","author":"AJ Aschoff","year":"2017","unstructured":"Aschoff AJ, Catalano C, Kirchin MA, Krix M, Albrecht T. Low radiation dose in computed tomography: the role of iodine. Br J Radiol. 2017;90:20170079.","journal-title":"Br J Radiol"},{"key":"1038_CR20","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1016\/j.carj.2018.05.004","volume":"69","author":"T Masuda","year":"2018","unstructured":"Masuda T, Funama Y, Nakaura T, Tahara M, Yamashita Y, Kiguchi M, et al. Radiation dose reduction with a low-tube voltage technique for pediatric chest computed tomographic angiography based on the contrast-to-noise ratio index. Can Assoc Radiol J. 2018;69:390\u20136.","journal-title":"Can Assoc Radiol J"},{"key":"1038_CR21","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1097\/RLI.0000000000000537","volume":"54","author":"AE Papadakis","year":"2019","unstructured":"Papadakis AE. Automatic tube current modulation and tube voltage selection in pediatric computed tomography: a phantom study on radiation dose and image quality. Invest Radiol. 2019;54:265\u201372.","journal-title":"Invest Radiol"},{"key":"1038_CR22","doi-asserted-by":"publisher","first-page":"1332","DOI":"10.2214\/AJR.14.13957","volume":"205","author":"M Kok","year":"2015","unstructured":"Kok M, Mihl C, Seehofnerov\u00e1 A, Turek J, Jost G, Pietsch H, et al. Automated tube voltage selection for radiation dose reduction in CT angiography using different contrast media concentrations and a constant iodine delivery rate. AJR Am J Roentgenol. 2015;205:1332\u20138.","journal-title":"AJR Am J Roentgenol"},{"key":"1038_CR23","doi-asserted-by":"publisher","first-page":"1031","DOI":"10.3348\/kjr.2018.19.6.1031","volume":"19","author":"HW Goo","year":"2018","unstructured":"Goo HW. Image quality and radiation dose of high-pitch dual-source spiral cardiothoracic computed tomography in young children with congenital heart disease: comparison of non-electrocardiography synchronization and prospective electrocardiography triggering. Korean J Radiol. 2018;19:1031\u201341.","journal-title":"Korean J Radiol"},{"key":"1038_CR24","doi-asserted-by":"publisher","first-page":"1306","DOI":"10.2214\/AJR.10.4416","volume":"195","author":"WH Sommer","year":"2010","unstructured":"Sommer WH, Albrecht E, Bamberg F, Schenzle JC, Johnson TR, Neumaier K, et al. Feasibility and radiation dose of high-pitch acquisition protocols in patients undergoing dual-source cardiac CT. AJR Am J Roentgenol. 2010;195:1306\u201312.","journal-title":"AJR Am J Roentgenol"},{"key":"1038_CR25","doi-asserted-by":"publisher","DOI":"10.1016\/j.radi.2025.102985","volume":"31","author":"T Masuda","year":"2025","unstructured":"Masuda T, Nakaura T, Funama Y, Sato T, Arao K, Miyata J, et al. Radiation dose in 1-60-month children undergoing 64-detector cardiac CT angiography: ECG-gated versus non-gated scans. Radiography (Lond). 2025;31:102985.","journal-title":"Radiography (Lond)"},{"key":"1038_CR26","doi-asserted-by":"publisher","first-page":"766","DOI":"10.1016\/j.radi.2022.03.004","volume":"28","author":"T Masuda","year":"2022","unstructured":"Masuda T, Funama Y, Nakaura T, Sato T, Okimoto T, Gotanda R, Arao K, Imaizumi H, Arao S, Ono A, Hiratsuka J, Awai K. Radiation dose reduction method combining the ECG-Edit function and high helical pitch in retrospectively-gated CT angiography. Radiography (Lond). 2022;28:766\u201371.","journal-title":"Radiography (Lond)"},{"key":"1038_CR27","doi-asserted-by":"publisher","first-page":"758","DOI":"10.1007\/s00247-024-05862-3","volume":"54","author":"T Masuda","year":"2024","unstructured":"Masuda T, Kiguchi M, Fujioka C, Oku T, Ishibashi T, Katsunuma Y, Yoshitake T, Abe S, Awai K. Impact of beam collimation of z-overscanning on dose to the lens and thyroid gland in paediatric thoracic computed tomography imaging. Pediatr Radiol. 2024;54:758\u201363.","journal-title":"Pediatr Radiol"},{"key":"1038_CR28","doi-asserted-by":"publisher","first-page":"1197","DOI":"10.1007\/s00247-024-05947-z","volume":"54","author":"T Masuda","year":"2024","unstructured":"Masuda T, Kiguchi M, Fujioka C, Oku T, Ishibashi T, Katsunuma Y, Yoshitake T, Abe S, Awai K. Comparison of pediatric lens scattered dose measurements between axial 40-mm and helical 160-mm detector width computed tomography scan modes. Pediatr Radiol. 2024;54:1197\u2013204.","journal-title":"Pediatr Radiol"},{"key":"1038_CR29","doi-asserted-by":"publisher","first-page":"1315","DOI":"10.2214\/AJR.14.13941","volume":"205","author":"YJ Ryu","year":"2015","unstructured":"Ryu YJ, Kim WS, Choi YH, Cheon JE, Lee SM, Cho HH, et al. Pediatric chest CT: wide-volume and helical scan modes in 320-MDCT. AJR Am J Roentgenol. 2015;205:1315\u201321.","journal-title":"AJR Am J Roentgenol"},{"key":"1038_CR30","doi-asserted-by":"publisher","first-page":"1463","DOI":"10.1007\/s00247-017-3901-2","volume":"47","author":"G Shirota","year":"2017","unstructured":"Shirota G, Maeda E, Namiki Y, Bari R, Ino K, Torigoe R, Abe O. Pediatric 320-row cardiac computed tomography using electrocardiogram-gated model-based full iterative reconstruction. Pediatr Radiol. 2017;47:1463\u201370.","journal-title":"Pediatr Radiol"},{"key":"1038_CR31","doi-asserted-by":"publisher","first-page":"163","DOI":"10.2214\/AJR.10.5250","volume":"197","author":"A Khan","year":"2011","unstructured":"Khan A, Khosa F, Nasir K, Yassin A, Clouse ME. Comparison of radiation dose and image quality: 320-MDCT versus 64-MDCT coronary angiography. AJR Am J Roentgenol. 2011;197:163\u20138.","journal-title":"AJR Am J Roentgenol"},{"key":"1038_CR32","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3348\/kjr.2012.13.1.1","volume":"13","author":"HW Goo","year":"2012","unstructured":"Goo HW. CT radiation dose optimization and estimation: an update for radiologists. Korean J Radiol. 2012;13:1\u201311.","journal-title":"Korean J Radiol"},{"key":"1038_CR33","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.221257","volume":"306","author":"LR Koetzier","year":"2023","unstructured":"Koetzier LR, Mastrodicasa D, Szczykutowicz TP, van der Werf NR, Wang AS, Sandfort V, et al. Deep learning image reconstruction for CT: technical principles and clinical prospects. Radiology. 2023;306:e221257.","journal-title":"Radiology"},{"key":"1038_CR34","doi-asserted-by":"publisher","first-page":"1936","DOI":"10.1148\/rg.2021210105","volume":"41","author":"Y Nagayama","year":"2021","unstructured":"Nagayama Y, Sakabe D, Goto M, Emoto T, Oda S, Nakaura T, et al. Deep learning\u2013based reconstruction for lower-dose pediatric CT: technical principles, image characteristics, and clinical implementations. Radiographics. 2021;41:1936\u201353.","journal-title":"Radiographics"},{"key":"1038_CR35","doi-asserted-by":"publisher","first-page":"3238","DOI":"10.21037\/qims-21-936","volume":"12","author":"K Zhang","year":"2022","unstructured":"Zhang K, Shi X, Xie SS, Sun JH, Liu ZH, Zhang S, Song JY, Shen W. Deep learning image reconstruction in pediatric abdominal and chest computed tomography: a comparison of image quality and radiation dose. Quant Imaging Med Surg. 2022;12:3238\u201350.","journal-title":"Quant Imaging Med Surg"},{"key":"1038_CR36","doi-asserted-by":"publisher","first-page":"645","DOI":"10.2214\/AJR.14.12590","volume":"204","author":"MJ AMd Harder","year":"2015","unstructured":"AMd Harder MJ, Willemink RPJ, Budde AMR, Schilham T, Leiner. PAd Jong. Hybrid and Model-Based Iterative Reconstruction Techniques for Pediatric CT. Am J Roentgenol. 2015;204:645\u201353.","journal-title":"Am J Roentgenol"},{"key":"1038_CR37","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1007\/s00247-017-3991-x","volume":"48","author":"CK Rigsby","year":"2018","unstructured":"Rigsby CK, McKenney SE, Hill KD, Chelliah A, Einstein AJ, Han BK, et al. Radiation dose management for pediatric cardiac computed tomography: a report from the image gently \u2018have-a-heart\u2019 campaign. Pediatr Radiol. 2018;48:5\u201320.","journal-title":"Pediatr Radiol"},{"key":"1038_CR38","doi-asserted-by":"publisher","first-page":"759","DOI":"10.5152\/akd.2014.5720","volume":"15","author":"E \u00dcnal","year":"2015","unstructured":"\u00dcnal E, Y\u0131ld\u0131z AE, G\u00fcler E, Karcaalt\u0131ncaba M, Akata D, K\u0131l\u0131n\u00e7er A, et al. Comparison of image quality and radiation dose between prospectively ECG-triggered and retrospectively ECG-gated CT angiography: establishing heart rate cut-off values in first-generation dual-source CT. Anatol J Cardiol. 2015;15:759\u201364.","journal-title":"Anatol J Cardiol"},{"key":"1038_CR39","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1016\/j.ejmp.2018.05.015","volume":"49","author":"BH Geryes","year":"2018","unstructured":"Geryes BH, Calmon R, Donciu V, Khraiche D, Warin-Fresse K, Bonnet D, et al. Low-dose paediatric cardiac and thoracic computed tomography with prospective triggering: is it possible at any heart rate? Phys Med. 2018;49:99\u2013104.","journal-title":"Phys Med"},{"key":"1038_CR40","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-025-11719-6","author":"S Hellms","year":"2025","unstructured":"Hellms S, Werncke T, B\u00f6ttcher J, Happel CM, Eckstein J, Krueger MB, et al. Reduction of radiation exposure and preserved image quality using photon-counting detector cardiac computed tomography without electrocardiographic gating in children with congenital heart disease. Eur Radiol. 2025. https:\/\/doi.org\/10.1007\/s00330-025-11719-6.","journal-title":"Eur Radiol"},{"key":"1038_CR41","doi-asserted-by":"publisher","DOI":"10.1007\/s00247-025-06336-w","author":"GM Arguello Fletes","year":"2025","unstructured":"Arguello Fletes GM, Zhou W, Malone LJ, Fuentealba Cargill AI, Weinman JP, Browne LP. Comparative radiation dose analysis in pediatric high-pitch cardiac CTA using photon-counting versus energy-integrating detector CT. Pediatr Radiol. 2025. https:\/\/doi.org\/10.1007\/s00247-025-06336-w.","journal-title":"Pediatr Radiol"},{"key":"1038_CR42","doi-asserted-by":"publisher","first-page":"580","DOI":"10.2214\/AJR.22.28391","volume":"220","author":"J Cao","year":"2023","unstructured":"Cao J, Bache S, Schwartz FR, Frush D. Pediatric applications of photon-counting detector CT. AJR Am J Roentgenol. 2023;220:580\u20139.","journal-title":"AJR Am J Roentgenol"},{"key":"1038_CR43","doi-asserted-by":"publisher","first-page":"1984","DOI":"10.1007\/s00247-024-06078-1","volume":"54","author":"AM El-Ali","year":"2024","unstructured":"El-Ali AM, Strubel N, Pinkney L, Xue C, Dane B, Lala SV. Pediatric contrast-enhanced chest CT on a photon-counting detector CT: radiation dose and image quality compared to energy-integrated detector CT. Pediatr Radiol. 2024;54:1984\u201395.","journal-title":"Pediatr Radiol"},{"key":"1038_CR44","doi-asserted-by":"publisher","DOI":"10.1093\/bjr\/tqaf088","author":"KK Horst","year":"2025","unstructured":"Horst KK, Yu L, Larson HT, Siegel MJ. Photon-counting detector CT in paediatric imaging: a review of current literature and future directions. Br J Radiol. 2025. https:\/\/doi.org\/10.1093\/bjr\/tqaf088.","journal-title":"Br J Radiol"},{"key":"1038_CR45","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1007\/s42399-023-01624-8","volume":"5","author":"K Arao","year":"2023","unstructured":"Arao K, Masuda T, Funama Y, Nakaura T, Sato T, Masuda S, Oku T, Arao S, Ono A, Hiratsuka J, Awai K. Posteroanterior Scout View of Pediatric Patients Using Computed Tomography During Different Tube Voltages: Validation Using Pediatric Anthropomorphic Phantoms. SN Compr Clin Med. 2023;5:282.","journal-title":"SN Compr Clin Med"},{"key":"1038_CR46","doi-asserted-by":"crossref","unstructured":"Masuda T, Funama Y, Nakaura T, Sato T, Tahara M, Yamashita Y, Masuda S, Yoshiura T, Oku T, Arao S, Hiratsuka J, Awai K. Usefulness of the superior orbitomeatal line without the lens included in the scan range at different tube voltage during pediatric head CT. Radiolog\u00eda. 2024 Sep-Oct;66(5):403-409.47.","DOI":"10.1016\/j.rxeng.2023.05.003"},{"key":"1038_CR47","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1007\/s13246-023-01217-8","volume":"46","author":"T Masuda","year":"2023","unstructured":"Masuda T, Funama Y, Nakaura T, Sato T, Urayama K, Kiguchi M, Oku T, Yoshida M, Arao S, Ono A, Hiratsuka J, Awai K. Usefulness of large beam-shaping filters at different tube voltages of newborn chest CT. Phys Eng Sci Med. 2023;46:289\u201393.","journal-title":"Phys Eng Sci Med"},{"key":"1038_CR48","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1007\/s12194-024-00855-1","volume":"18","author":"T Masuda","year":"2025","unstructured":"Masuda T, Funama Y, Nakaura T, Sato T, Oku T, Ono A, Awai K. Effectiveness of the air-gap method for reducing radiation dose in neonate CT examinations. Radiol Phys Technol. 2025;18:293\u20139.","journal-title":"Radiol Phys Technol"},{"key":"1038_CR49","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1093\/rpd\/ncab102","volume":"194","author":"T Masuda","year":"2021","unstructured":"Masuda T, Funama Y, Nakaura T, Sato T, Tahara M, Takei Y, et al. USE OF VACUUM MATTRESSES CAN REDUCE THE ABSORBED DOSE DURING PEDIATRIC CT. Radiat Prot Dosimetry. 2021;194:201\u20137.","journal-title":"Radiat Prot Dosimetry"},{"key":"1038_CR50","doi-asserted-by":"publisher","first-page":"802","DOI":"10.6009\/jjrt.2020_JSRT_76.8.802","volume":"76","author":"T Yoshiura","year":"2020","unstructured":"Yoshiura T, Masuda T, Matsumoto Y, Sato T, Kikuhara Y, Kobayashi Y, et al. [New Potential Method for Optimizing the ATCM Technique in Pediatric CT Examination]. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2020;76:802\u20137.","journal-title":"Nihon Hoshasen Gijutsu Gakkai Zasshi"},{"key":"1038_CR51","doi-asserted-by":"publisher","first-page":"3093","DOI":"10.1118\/1.2748113","volume":"34","author":"T Toth","year":"2007","unstructured":"Toth T, Ge Z, Daly MP. The influence of patient centering on CT dose and image noise. Med Phys. 2007;34:3093\u2013101.","journal-title":"Med Phys"},{"key":"1038_CR52","doi-asserted-by":"publisher","DOI":"10.1186\/s12880-025-01860-5","volume":"25","author":"RY Ampofo","year":"2025","unstructured":"Ampofo RY, Kyei KA, Daniels J, Nyantakyi AY. Determination of redundant scan coverages along the Z-axis and dose implications for common paediatric computed tomography imaging examinations in a limited resource setting. BMC Med Imaging. 2025;25:317.","journal-title":"BMC Med Imaging"},{"key":"1038_CR53","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1007\/s10278-021-00580-w","volume":"35","author":"L DeWeese","year":"2022","unstructured":"DeWeese L, Griglock T, Moody A, Mehlberg A, Winters C. The improvement of patient centering in computed tomography through a technologist-focused education initiative. J Digit Imaging. 2022;35:327\u201334.","journal-title":"J Digit Imaging"},{"key":"1038_CR54","doi-asserted-by":"publisher","DOI":"10.1093\/bjr\/tqaf116","author":"L Ren","year":"2025","unstructured":"Ren L, Duan X, Ahn R, Kay F, Daftaribesheli L, Zhou W, et al. Photon-counting detector CT: technology overview and radiation dose reduction. Br J Radiol. 2025. https:\/\/doi.org\/10.1093\/bjr\/tqaf116.","journal-title":"Br J Radiol"},{"key":"1038_CR55","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1002\/jmrs.824","volume":"72","author":"E Gyan","year":"2025","unstructured":"Gyan E, Subaar C, Edusei G, Antwi Nyarko L. Paediatric computed tomography diagnostic reference levels in Africa: a systematic review. J Med Radiat Sci. 2025;72:139\u201347.","journal-title":"J Med Radiat Sci"},{"key":"1038_CR56","doi-asserted-by":"publisher","DOI":"10.3390\/app14177583","volume":"14","author":"KM Aloufi","year":"2024","unstructured":"Aloufi KM, Alhazmi FH, Alrehily FA, Alraddadi NS, Alharbi AS, Alamin AM, et al. Assessing effective doses and proposing DRLs for pediatric CT procedures in Madinah (Single Hospital), Saudi Arabia. Appl Sci. 2024;14:7583.","journal-title":"Appl Sci"},{"key":"1038_CR57","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2025.105056","volume":"136","author":"M Alanazi","year":"2025","unstructured":"Alanazi M, Kench P, Tavakoli-Taba S, Ekpo E. Automated radiation dose monitoring software packages: impact on computed tomography (CT) dose management and optimisation, implementation challenges, and practical considerations: a systematic review. Phys Med. 2025;136:105056.","journal-title":"Phys Med"},{"key":"1038_CR58","doi-asserted-by":"publisher","first-page":"1027","DOI":"10.1007\/s12149-025-02102-y","volume":"39","author":"K Abe","year":"2025","unstructured":"Abe K, Baba S, Etani R, Fujimto T, Hosono M, Iimori T, et al. Establishment of national diagnostic reference levels 2025 for nuclear medicine in Japan. Ann Nucl Med. 2025;39:1027\u201336.","journal-title":"Ann Nucl Med"},{"key":"1038_CR59","doi-asserted-by":"publisher","DOI":"10.3390\/children10040645","author":"E Shelly","year":"2023","unstructured":"Shelly E, Waldron MG, Field E, Moore N, Young R, Scally A, et al. Cumulative radiation dose from medical imaging in children with congenital heart disease: a systematic review. Children (Basel). 2023. https:\/\/doi.org\/10.3390\/children10040645.","journal-title":"Children (Basel)"},{"key":"1038_CR60","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1016\/j.jmir.2021.12.005","volume":"53","author":"O Lackay","year":"2022","unstructured":"Lackay O, Horn-Lodewyk J, Muller H. A practical guide for paediatric diagnostic reference levels (PiDRLs). J Med Imaging Radiat Sci. 2022;53:123\u201337.","journal-title":"J Med Imaging Radiat Sci"},{"key":"1038_CR61","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1148\/radiol.2482071804","volume":"248","author":"N Hirai","year":"2008","unstructured":"Hirai N, Horiguchi J, Fujioka C, Kiguchi M, Yamamoto H, Matsuura N, et al. Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: assessment of image quality, stenosis, and radiation dose. Radiology. 2008;248:424\u201330.","journal-title":"Radiology"},{"key":"1038_CR62","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1016\/j.rxeng.2023.05.003","volume":"66","author":"T Masuda","year":"2024","unstructured":"Masuda T, Funama Y, Nakaura T, Sato T, Kiguchi M, Oku T, Awai K. Usefulness of the superior orbitomeatal line without the lens included in the scan range at different tube voltage during pediatric head CT. Radiologia (Engl Ed). 2024;66:403\u20139.","journal-title":"Radiologia (Engl Ed)"},{"key":"1038_CR63","doi-asserted-by":"publisher","first-page":"1315","DOI":"10.2214\/AJR.14.13941","volume":"205","author":"YJ Ryu","year":"2015","unstructured":"Ryu YJ, Kim WS, Choi YH, Cheon J-E, Lee SM, Cho H-H, et al. Pediatric chest CT: wide-volume and helical scan modes in 320-MDCT. AJR Am J Roentgenol. 2015;205:1315\u201321.","journal-title":"AJR Am J Roentgenol"},{"key":"1038_CR64","doi-asserted-by":"publisher","first-page":"123","DOI":"10.2214\/AJR.13.12028","volume":"203","author":"T Kaasalainen","year":"2014","unstructured":"Kaasalainen T, Palmu K, Reijonen V, Kortesniemi M. Effect of patient centering on patient dose and image noise in chest CT. AJR Am J Roentgenol. 2014;203:123\u201330.","journal-title":"AJR Am J Roentgenol"},{"key":"1038_CR65","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-022-13404-w","volume":"12","author":"D Kravchenko","year":"2022","unstructured":"Kravchenko D, Hart C, Garbe S, Luetkens JA, Isaak A, Mesropyan N, et al. Image quality and radiation dose of dual source high pitch computed tomography in pediatric congenital heart disease. Sci Rep. 2022;12:9934.","journal-title":"Sci Rep"}],"container-title":["Radiological Physics and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-026-01038-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12194-026-01038-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-026-01038-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T08:03:15Z","timestamp":1781078595000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12194-026-01038-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,13]]},"references-count":65,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,6]]}},"alternative-id":["1038"],"URL":"https:\/\/doi.org\/10.1007\/s12194-026-01038-w","relation":{},"ISSN":["1865-0333","1865-0341"],"issn-type":[{"value":"1865-0333","type":"print"},{"value":"1865-0341","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,13]]},"assertion":[{"value":"7 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 March 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 March 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 March 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflicts of interest related to this work.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Ethics approval was waived by the Institutional Review Board of Kawasaki university of Medical Welfare because the study used anonymized data.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"This study did not involve human participants or identifiable human data; therefore, ethics approval and informed consent were not required.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}