{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T06:58:31Z","timestamp":1781074711000,"version":"3.54.1"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T00:00:00Z","timestamp":1778803200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T00:00:00Z","timestamp":1778803200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Manipal Academy of Higher Education, Manipal"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol Phys Technol"],"published-print":{"date-parts":[[2026,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Paediatric pelvic radiography is a frequently performed diagnostic procedure that exposes radiosensitive organs to ionising radiation. Optimisation of imaging parameters is essential to minimise radiation dose while preserving diagnostic image quality. This systematic review aimed to evaluate technical strategies for radiation dose optimisation in paediatric pelvic radiography and assess their impact on radiation dose and image quality. A systematic search of PubMed, Scopus, Embase, and Web of Science was conducted for studies published between 2004 and 2025. Experimental and clinical studies assessing radiation dose and image quality in paediatric pelvic radiography were included. Data on exposure parameters, dose metrics, and image quality assessment methods were extracted and synthesised narratively. Nine studies met the inclusion criteria, predominantly comprising phantom-based experimental designs. Increasing tube potential (kVp), extending source-to-image distance (SID), and applying additional aluminium or copper filtration consistently reduced radiation dose. Dose reductions of up to 60\u201370% were reported without clinically significant loss of image quality. Although objective image quality metrics (e.g., CNR, SNR) occasionally declined, subjective assessments confirmed that images remained diagnostically acceptable. Optimisation of technical parameters in paediatric pelvic radiography can achieve substantial radiation dose reduction while maintaining clinically acceptable image quality. However, the predominance of phantom-based evidence highlights the need for further patient-based clinical studies to support routine implementation.<\/jats:p>","DOI":"10.1007\/s12194-026-01055-9","type":"journal-article","created":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T13:59:37Z","timestamp":1778853577000},"page":"454-470","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Technical strategies for radiation dose optimisation in paediatric pelvic radiography: a systematic review"],"prefix":"10.1007","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4286-1891","authenticated-orcid":false,"given":"Koustubh","family":"Kamath","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9345-9790","authenticated-orcid":false,"given":"Suresh","family":"Sukumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leena R.","family":"David","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3486-8740","authenticated-orcid":false,"given":"Rajagopal","family":"Kadavigere","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hitesh Hasmukhlal","family":"Shah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3725-6774","authenticated-orcid":false,"given":"Nitika C.","family":"Panakkal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2910-5338","authenticated-orcid":false,"given":"Abhimanyu","family":"Pradhan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5963-3230","authenticated-orcid":false,"given":"Winniecia","family":"Dkhar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hari Prakash","family":"Planiswamy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4421-038X","authenticated-orcid":false,"given":"Sneha","family":"Ravichandran","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-7053-4878","authenticated-orcid":false,"given":"Dilip","family":"Shettigar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-8629-7891","authenticated-orcid":false,"given":"Sathya Sabina","family":"Muthu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,15]]},"reference":[{"key":"1055_CR1","unstructured":"Ibrahim D, Ayaninola, Hamza, Umar AM. Determination Of Entrance Skin Dose From Diagnostic X-Ray Of Human Chest At Federal Medical Centre Keffi, Nigeria. Sci World J 2014;9(1):14\u201318."},{"key":"1055_CR2","doi-asserted-by":"publisher","first-page":"p1","DOI":"10.30560\/mhs.v3n2p1","volume":"3","author":"R Davoodi","year":"2020","unstructured":"Davoodi R, Eydian M-R, Karampour H, Nassarpour M, Rezazadeh-Farokh R, Maraei A, et al. Application of Dose Area Product (DAP) to Estimate Entrance Surface Dose (ESD) in Pediatric Chest X-Rays. Mod Health Sci. 2020;3(2):1\u20136. https:\/\/doi.org\/10.30560\/mhs.v3n2p1","journal-title":"Mod Health Sci"},{"key":"1055_CR3","doi-asserted-by":"publisher","first-page":"119","DOI":"10.2478\/pjmpe-2020-0013","volume":"26","author":"K Shamsi","year":"2020","unstructured":"Shamsi K, Monfared AS, Deevband MR, Mohsenzadeh B, Ghorbani M, Gorji KE, et al. Evaluation of effective dose and entrance skin dose in digital radiology. Pol J Med Phys Eng. 2020;26(2):119\u2013125. https:\/\/doi.org\/10.2478\/pjmpe-2020-0013","journal-title":"Pol J Med Phys Eng"},{"key":"1055_CR4","doi-asserted-by":"publisher","DOI":"10.1186\/s44330-024-00010-7","author":"J Rong","year":"2024","unstructured":"Rong J, Liu Y. Advances in medical imaging techniques. BMC Methods. 2024;1(10). https:\/\/doi.org\/10.1186\/s44330-024-00010-7","journal-title":"BMC Methods"},{"key":"1055_CR5","doi-asserted-by":"publisher","first-page":"152435","DOI":"10.1016\/j.semarthrit.2024.152435","volume":"67","author":"C-P Enrique","year":"2024","unstructured":"Enrique C-P, Mar\u00eda SA, Gustavo R-S, Igor R, Magali C-M, Diana P-O, et al. Assessment of enthesopathy in conventional pelvis radiography: Another tool for spondyloarthritis diagnosis beyond sacroiliitis. Semin Arthritis Rheum. 2024;67:152435. https:\/\/doi.org\/10.1016\/j.semarthrit.2024.152435","journal-title":"Semin Arthritis Rheum"},{"key":"1055_CR6","doi-asserted-by":"publisher","unstructured":"PheyMing Yeap MJB. The pelvic radiograph: lines, arcs and stripes. Singapore Med J 2021;62(7):333\u201334 . https:\/\/doi.org\/10.11622\/smedj.2021091","DOI":"10.11622\/smedj.2021091"},{"key":"1055_CR7","doi-asserted-by":"publisher","first-page":"3182","DOI":"10.1111\/ans.17890","volume":"92","author":"ATM Nguyen","year":"2022","unstructured":"Nguyen ATM, Drynan DP, Holland AJA. Paediatric pelvic fractures \u2013 an updated literature review. ANZ J Surg. 2022;92(12):3182\u201394. https:\/\/doi.org\/10.1111\/ans.17890","journal-title":"ANZ J Surg"},{"key":"1055_CR8","doi-asserted-by":"publisher","unstructured":"Gaillard F, Weerakkody Y, Qureshi PAAA. Developmental dysplasia of the hip. Radiopaedia.org, Radiopaedia.org; 2008. https:\/\/doi.org\/10.53347\/rID-1214","DOI":"10.53347\/rID-1214"},{"key":"1055_CR9","doi-asserted-by":"publisher","unstructured":"Ibrahim SAM, Salem Alyafei T, Saloum NM, Sabawi M. Role of imaging in a limping child. 2019. https:\/\/doi.org\/10.26044\/ecr2019\/C-1429","DOI":"10.26044\/ecr2019\/C-1429"},{"key":"1055_CR10","doi-asserted-by":"publisher","unstructured":"Ng J, Campos A, Murphy A et al. Pelvis radiograph (paediatric). Reference article Radiopaedia.or; 2019. https:\/\/doi.org\/10.53347\/rID-66653","DOI":"10.53347\/rID-66653"},{"key":"1055_CR11","doi-asserted-by":"publisher","unstructured":"Riskof ionizing radiation exposure to children: a subject review. American Academy of Pediatrics. Committee on Environmental Health. (1998). Pediatrics, 101(4 Pt 1), 717\u201319. https:\/\/doi.org\/10.1542\/peds.101.4.717","DOI":"10.1542\/peds.101.4.717"},{"key":"1055_CR12","doi-asserted-by":"publisher","first-page":"2078","DOI":"10.1001\/archinternmed.2009.427","volume":"169","author":"R Smith-Bindman","year":"2009","unstructured":"Smith-Bindman R, Lipson J, Marcus R, Kim KP, Mahesh M, Gould R, et al. Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch Intern Med. 2009;169(22):2078\u201386. https:\/\/doi.org\/10.1001\/archinternmed.2009.427","journal-title":"Arch Intern Med"},{"key":"1055_CR13","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1016\/S0140-6736(12)60815-0","volume":"380","author":"MS Pearce","year":"2012","unstructured":"Pearce MS, Salotti JA, Little MP, McHugh K, Lee C, Kim KP, et al. Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: A retrospective cohort study. Lancet. 2012;380:499\u2013505. https:\/\/doi.org\/10.1016\/S0140-6736(12)60815-0.","journal-title":"Lancet"},{"key":"1055_CR14","doi-asserted-by":"publisher","unstructured":"Mathews JD, Forsythe AV, Brady Z, Butler MW, Goergen SK, Byrnes GB, et al. Cancer risk in 680 000 people exposed to computed tomography scans in childhood or adolescence: Data linkage study of 11 million Australians. BMJ. 2013;346:f2360. https:\/\/doi.org\/10.1136\/bmj.f2360","DOI":"10.1136\/bmj.f2360"},{"key":"1055_CR15","unstructured":"EdwardW. Webster. Dose and Risk in Diagnostic Radiology: How Big? how Little? . Issue 16 of Lauriston S. Taylor lectures in radiation protection and measurements. ISSN 0277\u20139196 Issue 16 of Taylor Lectures n.d. Journal of Nuclear Medicine October 1993;34(10):1838. https:\/\/jnm.snmjournals.org\/content\/34\/10\/1838"},{"key":"1055_CR16","unstructured":"ICRP. The 2007 recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Annals of the ICRP, 2007;37."},{"key":"1055_CR17","doi-asserted-by":"publisher","first-page":"289","DOI":"10.2214\/ajr.176.2.1760289","volume":"176","author":"DJ Brenner","year":"2001","unstructured":"Brenner DJ, Elliston CD, Hall EJ, Berdon WE. Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT. Am J Roentgenol. 2001;176:289\u201396. https:\/\/doi.org\/10.2214\/ajr.176.2.1760289","journal-title":"Am J Roentgenol"},{"key":"1055_CR18","doi-asserted-by":"publisher","first-page":"868","DOI":"10.2214\/AJR.09.4091","volume":"194","author":"KJ Strauss","year":"2010","unstructured":"Strauss KJ, Goske MJ, Kaste SC, Bulas D, Frush DP, Butler P, et al. Image Gently: Ten Steps You Can Take to Optimize Image Quality and Lower CT Dose for Pediatric Patients. Am J Roentgenol. 2010;194:868\u201373. https:\/\/doi.org\/10.2214\/AJR.09.4091","journal-title":"Am J Roentgenol"},{"key":"1055_CR19","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1016\/j.jacr.2003.11.012","volume":"1","author":"DP Frush","year":"2004","unstructured":"Frush DP, Applegate K. Computed tomography and radiation: understanding the issues. J Am Coll Radiol. 2004;1:113\u201319. https:\/\/doi.org\/10.1016\/j.jacr.2003.11.012","journal-title":"J Am Coll Radiol"},{"key":"1055_CR20","unstructured":"Communicatingradiation risks in paediatric imaging: Information to support healthcare discussions about benefit and risk 2016:ISBN: 978924151034 :88. https:\/\/www.who.int\/publications\/i\/item\/978924151034"},{"key":"1055_CR21","doi-asserted-by":"publisher","first-page":"407","DOI":"10.3238\/arztebl.2011.0407","volume":"108","author":"G Alzen","year":"2011","unstructured":"Alzen G, Benz-Bohm G. Radiation protection in pediatric radiology. Dtsch Arztebl Int. 2011;108(24):407\u201314. https:\/\/doi.org\/10.3238\/arztebl.2011.0407","journal-title":"Dtsch Arztebl"},{"key":"1055_CR22","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1148\/radiol.2481071451","volume":"248","author":"FA Mettler","year":"2008","unstructured":"Mettler FA, Huda W, Yoshizumi TT, Mahesh M. Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog. Radiology. 2008;248:254(1)\u2013263. https:\/\/doi.org\/10.1148\/radiol.2481071451","journal-title":"Radiology"},{"key":"1055_CR23","doi-asserted-by":"publisher","unstructured":"Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD et al. The PRISMA 2020 statement: An updated guideline for reporting systematic reviews. BMJ 2021;372:n71. https:\/\/doi.org\/10.1136\/bmj.n71","DOI":"10.1136\/bmj.n71"},{"key":"1055_CR24","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1093\/rpd\/nch015","volume":"108","author":"Y Grondin","year":"2004","unstructured":"Grondin Y, Matthews K, McEntee M, Rainford L, Casey M, Tonra M, et al. Dose-reducing strategies in combination offers substantial potential benefits to females requiring X-ray examination. Radiat Prot Dosimetry. 2004;108(2):123\u201332. https:\/\/doi.org\/10.1093\/rpd\/nch015","journal-title":"Radiat Prot Dosimetry"},{"key":"1055_CR25","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.jmir.2008.11.002","volume":"40","author":"ML Butler","year":"2009","unstructured":"Butler ML, Brennan PC. Nonselective Filters Offer Important Dose-Reducing Potential in Radiological Examination of the Paediatric Pelvis. J Med Imaging Radiat Sci. 2009;40(1):15\u201323. https:\/\/doi.org\/10.1016\/j.jmir.2008.11.002","journal-title":"J Med Imaging Radiat Sci"},{"key":"1055_CR26","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1007\/s12194-011-0115-4","volume":"4","author":"P Brosi","year":"2011","unstructured":"Brosi P, Stuessi A, Verdun FR, Vock P, Wolf R. Copper filtration in pediatric digital X-ray imaging: Its impact on image quality and dose. Radiol Phys Technol. 2011;4(2):148\u201355. https:\/\/doi.org\/10.1007\/s12194-011-0115-4","journal-title":"Radiol Phys Technol"},{"key":"1055_CR27","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1016\/j.radi.2014.05.012","volume":"20","author":"J Tugwell","year":"2014","unstructured":"Tugwell J, Everton C, Kingma A, Oomkens DM, Pereira GA, Pimentinha DB, et al. Increasing source to image distance for AP pelvis imaging - Impact on radiation dose and image quality. Radiography. 2014;20(4):351\u201355. https:\/\/doi.org\/10.1016\/j.radi.2014.05.012","journal-title":"Radiography"},{"key":"1055_CR28","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/j.radi.2014.04.007","volume":"20","author":"L Lan\u00e7a","year":"2014","unstructured":"Lan\u00e7a L, Franco L, Ahmed A, Harderwijk M, Marti C, Nasir S, et al. 10kVp rule - An anthropomorphic pelvis phantom imaging study using a CR system: Impact on image quality and effective dose using AEC and manual mode. Radiography. 2014;20 (4):333\u201338. https:\/\/doi.org\/10.1016\/j.radi.2014.04.007","journal-title":"Radiography"},{"key":"1055_CR29","doi-asserted-by":"publisher","unstructured":"Jreije A, Krynke L, Gricien\u0117 B, Rimkus B, Dementavi\u010dien\u0117 J, Skovorodko K. Evaluation of the performance of digital x-ray systems in pelvis radiography. J Radiol Prot 2024;44(3). https:\/\/doi.org\/10.1088\/1361-6498\/ad5d79","DOI":"10.1088\/1361-6498\/ad5d79"},{"key":"1055_CR30","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1007\/s12194-025-00890-6","volume":"18","author":"A Suzuki","year":"2025","unstructured":"Suzuki A, Hirofuji Y, Miyaji N, Funashima K, Takahashi I. Optimization of imaging conditions for infant hip imaging using flat panel detectors. Radiol Phys Technol. 2025;18(2):399\u2013406. https:\/\/doi.org\/10.1007\/s12194-025-00890-6","journal-title":"Radiol Phys Technol"},{"key":"1055_CR31","unstructured":"Bloomfield C, Boavida F, Chabloz D et al . Experimental article- Reducing effective dose to a pediatric phantom by using different combination of kVp, mAs and additional filters whilst maintaining image quality, radiation dose and image quality OPTIMAX 2014 \u2013 Radiation dose and image quality optimisation in medical imaging, 85\u201391."},{"key":"1055_CR32","doi-asserted-by":"publisher","first-page":"4771","DOI":"10.22038\/ijp.2017.22010.1841","volume":"5","author":"V Karami","year":"2017","unstructured":"Karami V, Zabihzadeh M, Shams N, Gilavand A. Optimization of radiological protection in pediatric patients undergoing common conventional radiological procedures: Effectiveness of increasing the film to focus distance (FFD). Int J Pediatr. 2017;5(4):4771\u201382. https:\/\/doi.org\/10.22038\/ijp.2017.22010.1841","journal-title":"Int J Pediatr"},{"key":"1055_CR33","doi-asserted-by":"publisher","unstructured":"Lai ZH, S\u00e1 dos Reis C, Sun Z. Effective dose and image optimisation of lateral lumbar spine radiography: a phantom study. Eur Radiol Exp. 2020;4(1). https:\/\/doi.org\/10.1186\/s41747-019-0132-3","DOI":"10.1186\/s41747-019-0132-3"},{"key":"1055_CR34","unstructured":"Heath R, England A, Ward A,et al. Digital pelvic radiography: increasing distance to reduce dose. Radiol Technol. 2011;83(1):20\u201328."},{"key":"1055_CR35","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1016\/j.radi.2013.05.003","volume":"19","author":"E Allen","year":"2013","unstructured":"Allen E, Hogg P, Ma WK, Szczepura K. Fact or fiction: An analysis of the 10kVp rule in computed radiography. Radiography. 2013;19(3):223\u201327. https:\/\/doi.org\/10.1016\/j.radi.2013.05.003","journal-title":"Radiography"},{"key":"1055_CR36","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1016\/j.clinimag.2011.09.006","volume":"36","author":"Z Sun","year":"2012","unstructured":"Sun Z, Lin C, Tyan YS, Ng KH. Optimization of chest radiographic imaging parameters: A comparison of image quality and entrance skin dose for digital chest radiography systems. Clin Imaging. 2012;36(4):279\u201386. https:\/\/doi.org\/10.1016\/j.clinimag.2011.09.006","journal-title":"Clin Imaging"},{"key":"1055_CR37","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1259\/bjr\/01948454","volume":"81","author":"EJ Hall","year":"2008","unstructured":"Hall EJ, Brenner DJ. Cancer risks from diagnostic radiology. Br J Radiol. 2008;81(965):362\u201378. https:\/\/doi.org\/10.1259\/bjr\/01948454","journal-title":"Br J Radiol"},{"key":"1055_CR38","doi-asserted-by":"publisher","first-page":"197","DOI":"10.2147\/DHPS.S507740","volume":"17","author":"M AlHawadi","year":"2025","unstructured":"AlHawadi M, Ayasrah M. Establishing of a National Diagnostic Reference Level for Radiation Dose in Digital Paediatric Pelvic X-Rays in Jordan: A Multicenter Retrospective Study. Drug Healthc Patient Saf. 2025;17:197\u201307. https:\/\/doi.org\/10.2147\/DHPS.S507740","journal-title":"Drug Healthc Patient Saf"}],"container-title":["Radiological Physics and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-026-01055-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12194-026-01055-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-026-01055-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T06:17:42Z","timestamp":1781072262000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12194-026-01055-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,15]]},"references-count":38,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,6]]}},"alternative-id":["1055"],"URL":"https:\/\/doi.org\/10.1007\/s12194-026-01055-9","relation":{},"ISSN":["1865-0333","1865-0341"],"issn-type":[{"value":"1865-0333","type":"print"},{"value":"1865-0341","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,15]]},"assertion":[{"value":"22 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 March 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 April 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 May 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Ethical approval was not required for this study as it is a systematic review based exclusively on previously published studies and did not involve human participants or identifiable patient data.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}