{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T06:58:27Z","timestamp":1781074707737,"version":"3.54.1"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T00:00:00Z","timestamp":1778630400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T00:00:00Z","timestamp":1778630400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol Phys Technol"],"published-print":{"date-parts":[[2026,6]]},"DOI":"10.1007\/s12194-026-01067-5","type":"journal-article","created":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T05:38:16Z","timestamp":1778650696000},"page":"842-854","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The effect of boosted injection of saline on contrast effect in angiography"],"prefix":"10.1007","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-8580-4660","authenticated-orcid":false,"given":"Takashi","family":"Iwasaki","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hajime","family":"Sakamoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masaki","family":"Kuwabara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masashi","family":"Saito","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Kobayashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuji","family":"Sato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takashi","family":"Omino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yosuke","family":"Kogure","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shinsuke","family":"Kyogoku","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michimasa","family":"Suzuki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,13]]},"reference":[{"key":"1067_CR1","doi-asserted-by":"crossref","first-page":"46","DOI":"10.3143\/geriatrics.55.46","volume":"55","author":"N Yoshihara","year":"2018","unstructured":"Yoshihara N, Ishihara M. Geriatric Cardiovascular care update. Japan Geriatr J. 2018;55:46\u201350.","journal-title":"Japan Geriatr J"},{"key":"1067_CR2","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1016\/0002-9343(89)90437-3","volume":"86","author":"RG Cigarroa","year":"1989","unstructured":"Cigarroa RG, Lange RA, Williams RH, Hillis LD. Dosing of contrast material to prevent contrast nephropathy in patients with renal disease. Am J Med. 1989;86:649\u201352. https:\/\/doi.org\/10.1016\/0002-9343(89)90437-3.","journal-title":"Am J Med"},{"key":"1067_CR3","first-page":"933","volume":"61","author":"Guidelines for the","year":"2019","unstructured":"Guidelines for the. use of iodinated contrast media in patients with renal impairment. J Japanese Soc Nephrol. 2019;61:933\u20131081.","journal-title":"J Japanese Soc Nephrol"},{"key":"1067_CR4","doi-asserted-by":"publisher","first-page":"356","DOI":"10.1007\/s12928-014-0304-2","volume":"30","author":"T Nakama","year":"2015","unstructured":"Nakama T, Shibata Y, Kimura T, Fukushima Y, Inoue Y, Kuriyama N. A breakthrough transcollateral retrograde access for occlusive superficial femoral artery: Multi-Site Access and Sheath Insertion (MUSASHI) technique. Cardiovasc Interv Ther. 2015;30:356\u201361. https:\/\/doi.org\/10.1007\/s12928-014-0304-2.","journal-title":"Cardiovasc Interv Ther"},{"key":"1067_CR5","doi-asserted-by":"publisher","first-page":"2711","DOI":"10.4103\/0973-1482.206242","volume":"123","author":"X Wang","year":"2017","unstructured":"Wang X, Yarmohammadi H, Cao G, et al. Dual-phase cone-beam computed tomography in detecting small (<\u20093\u00a0cm) hepatocellular carcinoma during transarterial chemoembolization. Cancer. 2017;123:2711\u201320. https:\/\/doi.org\/10.4103\/0973-1482.206242.","journal-title":"Cancer"},{"key":"1067_CR6","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1136\/jnis-2022-018722","volume":"15","author":"E Raz","year":"2023","unstructured":"Raz E, Shapiro M, Nossek E, et al. Principles, techniques, and applications of high-resolution cone-beam CT angiography in the neuroangio suite. J Neurointerv Surg. 2023;15:124\u201332. https:\/\/doi.org\/10.1136\/jnis-2022-018722.","journal-title":"J Neurointerv Surg"},{"key":"1067_CR7","doi-asserted-by":"publisher","first-page":"711","DOI":"10.6009\/jjrt.2012_JSRT_68.6.711","volume":"68","author":"K Muroga","year":"2012","unstructured":"Muroga K, Hatcho A, Otsuka T, Fukuzawa A, Tsukimata T, Kawamura C. Examination of the effects of saline boosting on contrast injection duration and saline boosting methods. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2012;68:711\u20139. https:\/\/doi.org\/10.6009\/jjrt.2012_JSRT_68.6.711.","journal-title":"Nihon Hoshasen Gijutsu Gakkai Zasshi"},{"issue":"10","key":"1067_CR8","first-page":"756","volume":"62","author":"T Yuba","year":"2015","unstructured":"Yuba T. Development of CT contrast media injectors evolving with CT systems: DUAL SHOT GX7. J Japan Association Radiological Technol (Jpn J Radiol Technol). 2015;62(10):756.","journal-title":"J Japan Association Radiological Technol (Jpn J Radiol Technol)"},{"key":"1067_CR9","unstructured":"Japan Network for Research and Information on Medical Exposure (J-RIME). Diagnostic Reference Levels in Japan 2025. (Japan DRLs 2025). Published July 7, 2025. National Institutes for Quantum Science and Technology (QST), National Institute of Radiological Sciences. Available from: https:\/\/jrime.qst.go.jp\/report\/JapanDRLs2025_en.pdf)."},{"key":"1067_CR10","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1016\/S0741-5214(99)70279-X","volume":"29","author":"T Sandgren","year":"1999","unstructured":"Sandgren T, Sonesson B, Ahlgren \u00c5R, L\u00e4nne T. The diameter of the common femoral artery in healthy humans: influence of sex, age, and body size. J Vasc Surg. 1999;29:503\u201310. https:\/\/doi.org\/10.1016\/S0741-5214(99)70279-X.","journal-title":"J Vasc Surg"},{"key":"1067_CR11","first-page":"345","volume":"5","author":"AF AbuRahma","year":"1986","unstructured":"AbuRahma AF, Robinson PA, Boland JP. Doppler flow measurements of lower extremity arteries: adjusted normal velocities. J Ultrasound Med. 1986;5:345\u201351.","journal-title":"J Ultrasound Med"},{"key":"1067_CR12","first-page":"334","volume-title":"Vascular and Interventional Radiology: The Requisites","author":"JA Kaufman","year":"2014","unstructured":"Kaufman JA. Lower-extremity arteries. In: Kaufman JA, Lee MJ, editors. Vascular and Interventional Radiology: The Requisites. 2nd ed. Philadelphia: Elsevier Saunders; 2014. pp. 334\u201364.","edition":"2"},{"key":"1067_CR13","doi-asserted-by":"publisher","first-page":"E376","DOI":"10.1002\/ccd.29347","volume":"97","author":"Y Soga","year":"2021","unstructured":"Soga Y, Takahara M, Ito N, et al. Clinical impact of intravascular ultrasound-guided balloon angioplasty in patients with chronic limb threatening ischemia for isolated infrapopliteal lesion. Catheter Cardiovasc Interv. 2021;97:E376\u201384. https:\/\/doi.org\/10.1002\/ccd.29347.","journal-title":"Catheter Cardiovasc Interv"},{"key":"1067_CR14","doi-asserted-by":"publisher","first-page":"568","DOI":"10.21037\/qims-20-1097","volume":"12","author":"S Mori","year":"2022","unstructured":"Mori S, Hirano K, Takahara M, et al. Accuracy of quantitative vessel analysis in endovascular treatment for femoropopliteal lesions. Quant Imaging Med Surg. 2022;12:568\u201375. https:\/\/doi.org\/10.21037\/qims-20-1097.","journal-title":"Quant Imaging Med Surg"},{"key":"1067_CR15","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1177\/1708538120957480","volume":"29","author":"AS Verschuur","year":"2021","unstructured":"Verschuur AS, Groot Jebbink E, Lo-A-Njoe PE, van Weel V. Clinical validation of 2D perfusion angiography using Syngo iFlow software during peripheral arterial interventions. Vascular. 2021;29:380\u20136. https:\/\/doi.org\/10.1177\/1708538120957480.","journal-title":"Vascular"},{"key":"1067_CR16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/15910199211024056","volume":"16","author":"A Simgen","year":"2021","unstructured":"Simgen A, Mayer C, Kettner M, M\u00fchl-Benninghaus R, Reith W, Yilmaz U. Retrospective analysis of intracranial aneurysms after flow diverter treatment including color-coded imaging (syngo iFlow) as a predictor of aneurysm occlusion. Interv Neuroradiol. 2021;16:1\u201311. https:\/\/doi.org\/10.1177\/15910199211024056.","journal-title":"Interv Neuroradiol"},{"key":"1067_CR17","doi-asserted-by":"publisher","first-page":"66","DOI":"10.6009\/jjrt.2014_JSRT_70.1.66","volume":"70","author":"M Yasuo","year":"2014","unstructured":"Yasuo M. Evaluation study of abnormal detectability with Thurstone and Scheff\u00e9 (Nakaya) of paired comparison method using chest phantom. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2014;70:66\u201372. https:\/\/doi.org\/10.6009\/jjrt.2014_JSRT_70.1.66.","journal-title":"Nihon Hoshasen Gijutsu Gakkai Zasshi"},{"key":"1067_CR18","doi-asserted-by":"publisher","first-page":"17","DOI":"10.6009\/jjrt.2023-1174","volume":"79","author":"M Yasuo","year":"2023","unstructured":"Yasuo M. Design of X-ray images based on quantitative analysis: predictive model of image quality and physical quantity factors by multiple regression equation of visual evaluation (Scheff\u00e9\u2019s) and Physical quantities (Dose and Noise). Nihon Hoshasen Gijutsu Gakkai Zasshi. 2023;79:17\u201324. https:\/\/doi.org\/10.6009\/jjrt.2023-1174.","journal-title":"Nihon Hoshasen Gijutsu Gakkai Zasshi"},{"key":"1067_CR19","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1186\/s13244-024-01750-4","volume":"15","author":"MC McDermott","year":"2024","unstructured":"McDermott MC, Wildberger JE, Bae KT. Critical but commonly neglected factors that affect contrast medium administration in CT. Insights Imaging. 2024;15:219. https:\/\/doi.org\/10.1186\/s13244-024-01750-4.","journal-title":"Insights Imaging"},{"key":"1067_CR20","doi-asserted-by":"publisher","first-page":"962","DOI":"10.1097\/RCT.0000000000000292","volume":"39","author":"T Masuda","year":"2015","unstructured":"Masuda T, Funama Y, Nakaura T, et al. Delivering the saline chaser via a spiral flow-generating tube improves arterial enhancement for computed tomography angiography of the lower extremities. J Comput Assist Tomogr. 2015;39:962\u20138. https:\/\/doi.org\/10.1097\/RCT.0000000000000292.","journal-title":"J Comput Assist Tomogr"},{"key":"1067_CR21","doi-asserted-by":"publisher","first-page":"1192","DOI":"10.1299\/kikaib.70.1192","volume":"70","author":"H Hinohara","year":"2004","unstructured":"Hinohara H, Matsumura T, Hirata N, et al. Flow in a T-Junction Pipe. Trans Japan Soc Mech Eng (Series B). 2004;70:1192\u2013200. https:\/\/doi.org\/10.1299\/kikaib.70.1192.","journal-title":"Trans Japan Soc Mech Eng (Series B)"},{"key":"1067_CR22","doi-asserted-by":"publisher","first-page":"615","DOI":"10.1161\/CIRCULATIONAHA.113.001811","volume":"128","author":"F Liistro","year":"2013","unstructured":"Liistro F, Porto I, Angioli P, et al. Drug-eluting balloon in peripheral intervention for below-the-knee angioplasty evaluation (DEBATE-BTK): a randomized trial in diabetic patients with critical limb ischemia. Circulation. 2013;128:615\u201321. https:\/\/doi.org\/10.1161\/CIRCULATIONAHA.113.001811.","journal-title":"Circulation"},{"key":"1067_CR23","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1016\/j.ejrad.2009.08.011","volume":"77","author":"AN Keeling","year":"2011","unstructured":"Keeling AN, Khalidi K, Leong S, et al. Below knee angioplasty in elderly patients: predictors of major adverse clinical outcomes. Eur J Radiol. 2011;77:483\u20139. https:\/\/doi.org\/10.1016\/j.ejrad.2009.08.011.","journal-title":"Eur J Radiol"},{"key":"1067_CR24","doi-asserted-by":"publisher","first-page":"1329","DOI":"10.3389\/fphys.2019.01329","volume":"10","author":"E Nader","year":"2019","unstructured":"Nader E, Skinner S, Romana M, et al. Blood rheology: key parameters, impact on blood flow, role in sickle cell disease and effects of exercise. Front Physiol. 2019;10:1329. https:\/\/doi.org\/10.3389\/fphys.2019.01329.","journal-title":"Front Physiol"},{"key":"1067_CR25","doi-asserted-by":"publisher","first-page":"107","DOI":"10.3233\/BIR-1993-30202","volume":"30","author":"KA Brookshier","year":"1993","unstructured":"Brookshier KA, Tarbell JM. Evaluation of transparent blood analogue fluids: aqueous xanthan gum\u2013glycerin. Biorheology. 1993;30:107\u201316. https:\/\/doi.org\/10.3233\/BIR-1993-30202.","journal-title":"Biorheology"}],"container-title":["Radiological Physics and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-026-01067-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12194-026-01067-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-026-01067-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T06:17:07Z","timestamp":1781072227000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12194-026-01067-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,13]]},"references-count":25,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,6]]}},"alternative-id":["1067"],"URL":"https:\/\/doi.org\/10.1007\/s12194-026-01067-5","relation":{},"ISSN":["1865-0333","1865-0341"],"issn-type":[{"value":"1865-0333","type":"print"},{"value":"1865-0341","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,13]]},"assertion":[{"value":"28 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 April 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 May 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 May 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Kobayashi is an employee at Nemoto Kyorindo, Japan. The rest of the authors do not have any conflicts of interest to declare.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"<!--Emphasis Type='Bold' removed-->Conflict of interest"}},{"value":"This study was conducted based on a plan approved by the Ethics Committee of Juntendo University Urayasu Hospital (approval number: E21-0167) for evaluating the usefulness of dilution contrast imaging using a two-step injection method with dual injector and a new dilution solution using a phantom. Visual evaluation was conducted with the evaluators\u2019 health conditions taken into consideration, and the research method was explained to them (approval number: E21-0167). This study was also performed in accordance with the ethical standards as laid down in the 1964 Declaration of Helsinki and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"<!--Emphasis Type='Bold' removed-->Ethical approval"}},{"value":"The evaluators were given a thorough 10-min explanation before the study, and informed verbal consent was obtained regarding the contents of the experiment and use of the results.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"<!--Emphasis Type='Bold' removed-->Consent to participate"}},{"value":"Not applicable.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"<!--Emphasis Type='Bold' removed-->Consent for publication"}}]}}