{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T20:11:48Z","timestamp":1788639108098,"version":"build-2803163510"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2026,6,18]],"date-time":"2026-06-18T00:00:00Z","timestamp":1781740800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,6,18]],"date-time":"2026-06-18T00:00:00Z","timestamp":1781740800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["JP24K10920"],"award-info":[{"award-number":["JP24K10920"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol Phys Technol"],"published-print":{"date-parts":[[2026,9]]},"DOI":"10.1007\/s12194-026-01085-3","type":"journal-article","created":{"date-parts":[[2026,6,18]],"date-time":"2026-06-18T00:43:27Z","timestamp":1781743407000},"page":"1077-1088","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Dose rate dependence of incorrect sensing and triggering of defibrillation in cardiac implantable electronic devices: single manufacturer result with kV beam"],"prefix":"10.1007","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8408-4234","authenticated-orcid":false,"given":"Hiroaki","family":"Matsubara","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shina","family":"Watanabe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karin","family":"Shimosaka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryushi","family":"Kanou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takehiro","family":"Yoshida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideaki","family":"Hashizume","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masaru","family":"Yamamoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,18]]},"reference":[{"key":"1085_CR1","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1186\/1748-717X-7-198","volume":"7","author":"CW Hurkmans","year":"2012","unstructured":"Hurkmans CW, Knegjens JL, Oei BS, et al. Management of radiation oncology patients with a pacemaker or ICD: a new comprehensive practical guideline in The Netherlands. Dutch Society of Radiotherapy and Oncology (NVRO). Radiot Oncol. 2012;7:198.","journal-title":"Radiot Oncol"},{"key":"1085_CR2","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1007\/s00066-015-0817-3","volume":"191","author":"B Gauter-Fleckenstein","year":"2015","unstructured":"Gauter-Fleckenstein B, Israel CW, Dorenkamp M, et al. DEGRO\/DGK guideline for radiotherapy in patients with cardiac implantable electronic devices. Strahlenther Onkol. 2015;191:393\u2013404.","journal-title":"Strahlenther Onkol"},{"key":"1085_CR3","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1007\/s11547-015-0616-z","volume":"121","author":"F Salerno","year":"2016","unstructured":"Salerno F, Gomellini S, Caruso C, et al. Management of radiation therapy patients with cardiac defibrillator or pacemaker. Radiol Med. 2016;121:515\u201320.","journal-title":"Radiol Med"},{"key":"1085_CR4","doi-asserted-by":"publisher","first-page":"1247","DOI":"10.1111\/jce.13034","volume":"27","author":"M Tajstra","year":"2016","unstructured":"Tajstra M, Gadula-Gacek E, Buchta P, et al. Effect of therapeutic ionizing radiation on implantable electronic devices: systematic review and practical guidance. J Cardiovasc Electrophysiol. 2016;27:1247\u2013125.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"1085_CR5","doi-asserted-by":"publisher","first-page":"e97","DOI":"10.1016\/j.hrthm.2017.04.025","volume":"14","author":"JH Indik","year":"2017","unstructured":"Indik JH, Gimbel JR, Abe H, et al. 2017 HRS expert consensus statement on magnetic resonance imaging and radiation exposure in patients with cardiovascular implantable electronic devices. Heart Rhythm. 2017;14:e97\u2013153.","journal-title":"Heart Rhythm"},{"key":"1085_CR6","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/j.ijcard.2017.12.061","volume":"225","author":"M Zecchin","year":"2018","unstructured":"Zecchin M, Severgnini M, Fiorentino A, et al. Management of patients with cardiac implantable electronic devices (CIED) undergoing radiotherapy: a consensus document from Associazione Italiana Aritmologia e Cardiostimolazione (AIAC), Associazione Italiana Radioterapia Oncologica (AIRO), Associazione Italiana Fisica Medica (AIFM). Int J Cardiol. 2018;225:175\u201383.","journal-title":"Int J Cardiol"},{"key":"1085_CR7","doi-asserted-by":"publisher","first-page":"1106","DOI":"10.33963\/KP.15063","volume":"77","author":"M Tajstra","year":"2019","unstructured":"Tajstra M, Blamek S, Niedziela JT, et al. Patients with cardiac implantable electronic devices undergoing radiotherapy in Poland. Expert opinion of the heart rhythm section of the polish cardiac society and the polish society of radiation oncology. Kardiol Pol. 2019;77:1106\u201316.","journal-title":"Kardiol Pol"},{"key":"1085_CR8","doi-asserted-by":"publisher","first-page":"e757","DOI":"10.1002\/mp.13838","volume":"46","author":"M Miften","year":"2019","unstructured":"Miften M, Mihailidis D, Kry SF, et al. Management of radiotherapy patients with implanted cardiac pacemakers and defibrillators: a report of the AAPM TG-203. Med Phys. 2019;46:e757\u201388.","journal-title":"Med Phys"},{"key":"1085_CR9","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1093\/jrr\/rraa102","volume":"62","author":"T Ohno","year":"2021","unstructured":"Ohno T, Soejima T, Sekiguchi Y, et al. JASTRO\/JCS Guidelines for radiotherapy in patients with cardiac implantable electronic devices. J Radiat Res. 2021;62:172\u201384.","journal-title":"J Radiat Res"},{"issue":"4","key":"1085_CR10","doi-asserted-by":"publisher","first-page":"1489","DOI":"10.1002\/mp.14057","volume":"47","author":"H Matsubara","year":"2020","unstructured":"Matsubara H, Ezura T, Hashimoto Y, et al. Prediction of radiation-induced malfunction for cardiac implantable electronic devices (CIEDs). Med Phys. 2020;47(4):1489\u201398.","journal-title":"Med Phys"},{"key":"1085_CR11","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1093\/europace\/eut249","volume":"16","author":"T Zaremba","year":"2014","unstructured":"Zaremba T, Jakobsen AR, Thogersen AM, et al. The effect of radiotherapy beam energy on modern cardiac devices: an in vitro study. Europace. 2014;16:612\u20136.","journal-title":"Europace"},{"key":"1085_CR12","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1007\/s10840-013-9861-z","volume":"39","author":"M Mollerus","year":"2014","unstructured":"Mollerus M, Naslund L, Lipinski M, et al. Radiation tolerance of contemporary implantable cardioverter-defibrillators. J Interv Card Electrophysiol. 2014;39:171\u20135.","journal-title":"J Interv Card Electrophysiol"},{"key":"1085_CR13","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1016\/j.zemedi.2020.12.003","volume":"31","author":"A Baehr","year":"2021","unstructured":"Baehr A, Conrads L, Oertel M, Haverkamp U, et al. Impact of different radiation techniques and doses on cardiac implantable electronic devices. Z Med Phys. 2021;31:327\u201335.","journal-title":"Z Med Phys"},{"key":"1085_CR14","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1016\/j.ijrobp.2005.04.047","volume":"63","author":"CW Hurkmans","year":"2005","unstructured":"Hurkmans CW, Scheepers E, Springorum BG, et al. Influence of radiotherapy on the latest generation of implantable cardioverter defibrillators. Int J Radiat Oncol Biol Phys. 2005;63:282\u20139.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1085_CR15","doi-asserted-by":"crossref","unstructured":"Gauter-Fleckenstein B, Nguyen J, Jahnke L, et al. Interaction between CIEDs and modern radiotherapy techniques: flattening filter free-VMAT, dose-rate effects, scatter radiation, and neutron-generating energies. Radiother Oncol. 2020;153:196\u2013202. and Gauter-Fleckenstein B, Nguyen J, Jahnke L, et al. Corrigendum to \u201dInteraction between CIEDs and modern radiotherapy techniques: flattening filter free-VMAT, dose-rate effects, scatter radiation, and neutron-generating energies\u201d [Radiother Oncol 152 (2020) 196-202]. Radiother Oncol. 2021; 154:291.","DOI":"10.1016\/j.radonc.2020.12.023"},{"key":"1085_CR16","doi-asserted-by":"publisher","first-page":"5936","DOI":"10.19102\/icrm.2024.15073","volume":"15","author":"Y Nishikawa","year":"2024","unstructured":"Nishikawa Y, Fujimoto N, Kurata T, et al. Effects of irradiation during computed tomography scanning on the function of implantable cardioverter-defibrillators. J Innov Card Rhythm Manag. 2024;15:5936\u201344.","journal-title":"J Innov Card Rhythm Manag"},{"key":"1085_CR17","doi-asserted-by":"publisher","first-page":"155","DOI":"10.2459\/JCM.0000000000000623","volume":"19","author":"M Zecchin","year":"2018","unstructured":"Zecchin M, Artico J, Morea G, et al. Radiotherapy and risk of implantable cardioverter-defibrillator malfunctions: experimental data from direct exposure at increasing doses. J Cardiovasc Med. 2018;19:155\u201360.","journal-title":"J Cardiovasc Med"},{"key":"1085_CR18","doi-asserted-by":"publisher","first-page":"1336","DOI":"10.1111\/jce.15475","volume":"33","author":"K Tsutsui","year":"2022","unstructured":"Tsutsui K, Kato R, Mori H, et al. Chest computer tomography is safe without additional interrogation or monitoring for modern cardiac implantable electrical devices. J Cardiovasc Electrophysiol. 2022;33:1336\u201340.","journal-title":"J Cardiovasc Electrophysiol"},{"key":"1085_CR19","first-page":"1006","volume":"62","author":"H Matsubara","year":"2021","unstructured":"Matsubara H, Ezura T, Hashimoto Y, et al. Study of feasible and safe condition for total body irradiation using cardiac implantable electronic devices. J Radiat Res. 2021;62:1006\u201314.","journal-title":"J Radiat Res"},{"key":"1085_CR20","doi-asserted-by":"publisher","first-page":"2879","DOI":"10.1088\/0031-9155\/47\/16\/304","volume":"47","author":"J Mouton","year":"2002","unstructured":"Mouton J, Haug R, Bridier A, et al. Influence of high-energy photon beam irradiation on pacemaker operation. Phys Med Biol. 2002;47:2879\u201393.","journal-title":"Phys Med Biol"},{"key":"1085_CR21","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1007\/s12194-023-00705-6","volume":"16","author":"H Matsubara","year":"2023","unstructured":"Matsubara H. Neutron dose from a 6-MV X-ray beam in radiotherapy. Radiol Phys Technol. 2023;16:186\u201394.","journal-title":"Radiol Phys Technol"},{"key":"1085_CR22","doi-asserted-by":"publisher","first-page":"e220","DOI":"10.1016\/j.hrthm.2019.02.034","volume":"17","author":"MK Stiles","year":"2020","unstructured":"Stiles MK, Fauchier L, Morillo C, et al. 2019 HRS\/EHRA\/APHRS\/LAHRS focused update to 2015 expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing. Heart Rhythm. 2020;17:e220\u20138.","journal-title":"Heart Rhythm"},{"key":"1085_CR23","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1016\/0360-3016(91)90172-Z","volume":"21","author":"C Burman","year":"1991","unstructured":"Burman C, Kutcher GJ, Enami B, et al. Fitting of normal tissue tolerance data to an analytic function. Int J Radiat Oncol Biol Phys. 1991;21:123\u201335.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1085_CR24","doi-asserted-by":"publisher","first-page":"766","DOI":"10.1148\/radiol.2433060993","volume":"243","author":"CH McCollough","year":"2007","unstructured":"McCollough CH, Zhang J, Primak AN, et al. Effects of CT irradiation on implantable cardiac rhythm management devices. Radiology. 2007;243:766\u201374.","journal-title":"Radiology"},{"key":"1085_CR25","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1080\/00223131.2023.2275736","volume":"61","author":"T Sato","year":"2024","unstructured":"Sato T, Iwamoto Y, Hashimoto S, et al. Recent improvements of the particle and heavy ion transport code system - PHITS version 3.33. J Nucl Sci Technol. 2024;61:127\u201335.","journal-title":"J Nucl Sci Technol"}],"container-title":["Radiological Physics and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-026-01085-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12194-026-01085-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-026-01085-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T20:03:08Z","timestamp":1788638588000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12194-026-01085-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,18]]},"references-count":25,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,9]]}},"alternative-id":["1085"],"URL":"https:\/\/doi.org\/10.1007\/s12194-026-01085-3","relation":{},"ISSN":["1865-0333","1865-0341"],"issn-type":[{"value":"1865-0333","type":"print"},{"value":"1865-0341","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,18]]},"assertion":[{"value":"17 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 June 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 June 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 June 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors have no conflicts of interest.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This research did not require IRB approval because no human\/animal data were employed.","order":2,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}}]}}