{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T18:18:41Z","timestamp":1791656321423,"version":"4.3.4"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T00:00:00Z","timestamp":1785715200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T00:00:00Z","timestamp":1785715200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol Phys Technol"],"published-print":{"date-parts":[[2026,9]]},"DOI":"10.1007\/s12194-026-01111-4","type":"journal-article","created":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T10:39:39Z","timestamp":1785753579000},"page":"1450-1459","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Accuracy evaluation and acceleration of Monte Carlo simulation of scattered radiation using a high-fidelity mobile X-ray fluoroscopy system model"],"prefix":"10.1007","volume":"19","author":[{"given":"Mao","family":"Tabuchi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9713-6155","authenticated-orcid":false,"given":"Toshioh","family":"Fujibuchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Donghee","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,3]]},"reference":[{"issue":"1","key":"1111_CR1","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1053\/j.tvir.2017.12.008","volume":"21","author":"DL Miller","year":"2018","unstructured":"Miller DL. Make radiation protection a habit. Tech Vasc Interv Radiol. 2018;21(1):37\u201342.","journal-title":"Tech Vasc Interv Radiol"},{"key":"1111_CR2","doi-asserted-by":"crossref","unstructured":"International Commission on Radiological Protection. Radiological protection in fluoroscopically guided procedures outside the imaging department. ICRP Publication 117. Ann ICRP. 2010;40(6).","DOI":"10.1016\/j.icrp.2012.03.001"},{"key":"1111_CR3","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.ejmp.2020.08.016","volume":"78","author":"M Abdelrahman","year":"2020","unstructured":"Abdelrahman M, Lombardo P, Camp A, et al. A parametric study of occupational radiation dose in interventional radiology by Monte Carlo simulations. Phys Med. 2020;78:58\u201370.","journal-title":"Phys Med"},{"issue":"5","key":"1111_CR4","doi-asserted-by":"publisher","first-page":"638","DOI":"10.1097\/01.HP.0000326341.86359.0b","volume":"95","author":"DL Miller","year":"2008","unstructured":"Miller DL. Overview of contemporary interventional fluoroscopy procedures. Health Phys. 2008;95(5):638\u201344.","journal-title":"Health Phys"},{"issue":"3","key":"1111_CR5","doi-asserted-by":"publisher","first-page":"945","DOI":"10.1148\/radiol.2482071800","volume":"248","author":"E Va\u00f1\u00f3","year":"2008","unstructured":"Va\u00f1\u00f3 E, Gonz\u00e1lez L, Fern\u00e1ndez JM, Haskal ZJ. Eye lens exposure to radiation in interventional suites: caution is warranted. Radiology. 2008;248(3):945\u201353.","journal-title":"Radiology"},{"issue":"3","key":"1111_CR6","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1097\/01.HP.0000290614.76386.35","volume":"94","author":"KP Kim","year":"2008","unstructured":"Kim KP, Miller DL, Balter S, et al. Occupational radiation doses to operators performing cardiac catheterization procedures. Health Phys. 2008;94(3):211\u201327.","journal-title":"Health Phys"},{"issue":"4","key":"1111_CR7","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1007\/s12194-019-00538-2","volume":"12","author":"Y Hirata","year":"2019","unstructured":"Hirata Y, Fujibuchi T, Fujita K, et al. Angular dependence of shielding effect of radiation protective eyewear for radiation protection of the crystalline lens. Radiol Phys Technol. 2019;12(4):401\u20138.","journal-title":"Radiol Phys Technol"},{"issue":"5","key":"1111_CR8","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1093\/jrr\/rraa034","volume":"61","author":"Y Haga","year":"2020","unstructured":"Haga Y, Chida K, Kimura Y, et al. Radiation eye dose to medical staff during respiratory endoscopy under X-ray fluoroscopy. J Radiat Res. 2020;61(5):691\u20136.","journal-title":"J Radiat Res"},{"key":"1111_CR9","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1016\/j.ejmp.2022.11.002","volume":"104","author":"S Busoni","year":"2022","unstructured":"Busoni S, Bruzzi M, Giomi S, et al. Surgeon eye lens dose monitoring in interventional neuroradiology, cardiovascular, and radiology procedures. Phys Med. 2022;104:123\u20138.","journal-title":"Phys Med"},{"issue":"4","key":"1111_CR10","doi-asserted-by":"publisher","first-page":"1956","DOI":"10.1002\/mp.14753","volume":"48","author":"AB Morcillo","year":"2021","unstructured":"Morcillo AB, Alejo L, Huerga C, et al. Occupational doses to the eye lens in pediatric and adult noncardiac interventional radiology procedures. Med Phys. 2021;48(4):1956\u201366.","journal-title":"Med Phys"},{"issue":"1","key":"1111_CR11","doi-asserted-by":"publisher","first-page":"288","DOI":"10.1007\/s12194-024-00779-w","volume":"17","author":"K Hizukuri","year":"2024","unstructured":"Hizukuri K, Fujibuchi T, Arakawa H. Directional vector visualization of scattered rays in mobile C-arm fluoroscopy. Radiol Phys Technol. 2024;17(1):288\u201396.","journal-title":"Radiol Phys Technol"},{"issue":"1","key":"1111_CR12","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1007\/s12194-026-01006-4","volume":"19","author":"T Fujibuchi","year":"2026","unstructured":"Fujibuchi T, Katayama R. Utilization of extended-reality technologies in the field of medical radiation. Radiol Phys Technol. 2026;19(1):21\u201344.","journal-title":"Radiol Phys Technol"},{"key":"1111_CR13","doi-asserted-by":"crossref","unstructured":"Nishi K, Fujibuchi T, Yoshinaga T. Development and evaluation of the effectiveness of educational material for radiological protection using augmented reality and virtual reality. J Radiol Prot. 2022;42(1).","DOI":"10.1088\/1361-6498\/ac3e0a"},{"key":"1111_CR14","doi-asserted-by":"crossref","unstructured":"Nishi K, Fujibuchi T, Yoshinaga T. Development of an application to visualize the spread of scattered radiation in radiography using augmented reality. J Radiol Prot. 2020;40(4).","DOI":"10.1088\/1361-6498\/abc14b"},{"key":"1111_CR15","doi-asserted-by":"crossref","unstructured":"Fujibuchi T. Radiation protection education using virtual reality by visualization of scatter distribution in radiological examination. J Radiol Prot. 2021;41(4).","DOI":"10.1088\/1361-6498\/ac16b1"},{"key":"1111_CR16","doi-asserted-by":"publisher","first-page":"405","DOI":"10.4028\/www.scientific.net\/AMR.1087.405","volume":"1087","author":"H Salleh","year":"2015","unstructured":"Salleh H, Samat S, Matori MK, et al. Anode\u2013cathode position: how it influences the radiation risk to staff involved in fluoroscopy procedures. Adv Mater Res. 2015;1087:405\u20139.","journal-title":"Adv Mater Res"},{"issue":"4","key":"1111_CR17","first-page":"627","volume":"62","author":"T Sato","year":"2021","unstructured":"Sato T, Iwamoto Y, Hashimoto S, et al. Track-structure modes in Particle and Heavy Ion Transport code System (PHITS): application to radiobiological research. J Radiat Res. 2021;62(4):627\u201340.","journal-title":"J Radiat Res"},{"issue":"6","key":"1111_CR18","doi-asserted-by":"publisher","first-page":"3782","DOI":"10.3390\/app13063782","volume":"13","author":"Y Hagihara","year":"2023","unstructured":"Hagihara Y, Sato T, Iwamoto Y, et al. Evaluation of parallel computing on MPI version PHITS code. Appl Sci. 2023;13(6):3782.","journal-title":"Appl Sci"},{"issue":"3","key":"1111_CR19","first-page":"264","volume":"35","author":"Y Sakamoto","year":"2015","unstructured":"Sakamoto Y, Sato T, Iwamoto Y, et al. Medical applications of the PHITS code (2): acceleration by parallel computing. Jpn J Med Phys. 2015;35(3):264\u201370.","journal-title":"Jpn J Med Phys"},{"issue":"6","key":"1111_CR20","doi-asserted-by":"publisher","first-page":"684","DOI":"10.1080\/00223131.2017.1419890","volume":"55","author":"T Sato","year":"2018","unstructured":"Sato T, Iwamoto Y, Hashimoto S, et al. Features of Particle and Heavy Ion Transport code System (PHITS) version 3.02. J Nucl Sci Technol. 2018;55(6):684\u201390.","journal-title":"J Nucl Sci Technol"},{"key":"1111_CR21","unstructured":"Sato T, Iwamoto Y, Hashimoto S et al. Overview of PHITS Ver. 3.34 with particular focus on track-structure calculation. EPJ Nucl Sci Technol. 2024."},{"issue":"1","key":"1111_CR22","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.1002\/mp.12702","volume":"45","author":"I Sechopoulos","year":"2018","unstructured":"Sechopoulos I, Rogers DWO, Bazalova-Carter M, et al. RECORDS: Improved reporting of Monte Carlo radiation transport studies. Med Phys. 2018;45(1):e1\u20135.","journal-title":"Med Phys"},{"key":"1111_CR23","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.ejmp.2020.04.026","volume":"75","author":"R Bujila","year":"2020","unstructured":"Bujila R, Omar A, Poludniowski G, et al. A validation of SpekPy: A software toolkit for modeling X-ray tube spectra. Phys Med. 2020;75:44\u201354.","journal-title":"Phys Med"},{"issue":"7","key":"1111_CR24","doi-asserted-by":"publisher","first-page":"3630","DOI":"10.1002\/mp.14945","volume":"48","author":"G Poludniowski","year":"2021","unstructured":"Poludniowski G, Omar A, Bujila R, et al. Technical note: SpekPy v2.0\u2014A software toolkit for modeling X-ray tube spectra. Med Phys. 2021;48(7):3630\u20137.","journal-title":"Med Phys"},{"key":"1111_CR25","doi-asserted-by":"crossref","unstructured":"Batista WO, Soares MR, Rios JMG. Effect of rotation axis and modulation on x-ray emission in dose assessment in panoramic radiographs using the Monte Carlo method. J Radiol Prot. 2026;46(2).","DOI":"10.1088\/1361-6498\/ae597a"}],"container-title":["Radiological Physics and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-026-01111-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12194-026-01111-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-026-01111-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T08:06:46Z","timestamp":1788595606000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12194-026-01111-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,3]]},"references-count":25,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,9]]}},"alternative-id":["1111"],"URL":"https:\/\/doi.org\/10.1007\/s12194-026-01111-4","relation":{},"ISSN":["1865-0333","1865-0341"],"issn-type":[{"value":"1865-0333","type":"print"},{"value":"1865-0341","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,3]]},"assertion":[{"value":"1 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 July 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 July 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 August 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no conflict of interest.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study did not involve human participants or animals and ethical approval was not required.","order":2,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Informed consent was not required for this study.","order":3,"name":"Ethics","label":"Informed consent","group":{"name":"EthicsHeading","label":"Declarations"}}]}}