{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T08:12:52Z","timestamp":1788595972603,"version":"build-2803163510"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T00:00:00Z","timestamp":1786060800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T00:00:00Z","timestamp":1786060800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol Phys Technol"],"published-print":{"date-parts":[[2026,9]]},"DOI":"10.1007\/s12194-026-01117-y","type":"journal-article","created":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T10:02:11Z","timestamp":1786096931000},"page":"1460-1465","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Effect of 70-kVp chest CT on surface dose at the mammary gland level in a neonatal phantom under matched CTDIvol conditions"],"prefix":"10.1007","volume":"19","author":[{"given":"Nanami","family":"Usui","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4164-4369","authenticated-orcid":false,"given":"Takanori","family":"Masuda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Norimi","family":"Nishiyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junichi","family":"Nakagawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mako","family":"Yamada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nagito","family":"Kuwada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hitoshi","family":"Takahata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takashi","family":"Amano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shinichi","family":"Arao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,7]]},"reference":[{"key":"1117_CR1","doi-asserted-by":"publisher","first-page":"289","DOI":"10.2214\/ajr.176.2.1760289","volume":"176","author":"DJ Brenner","year":"2001","unstructured":"Brenner DJ, Elliston CD, Hall EJ, Berdon WE. Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR Am J Roentgenol. 2001;176:289\u201396.","journal-title":"AJR Am J Roentgenol"},{"key":"1117_CR2","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1148\/radiol.2332032107","volume":"233","author":"MJ Siegel","year":"2004","unstructured":"Siegel MJ, Schmidt B, Bradley D, Suess C, Hildebolt C. Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape. Radiology. 2004;233:515\u201322.","journal-title":"Radiology"},{"key":"1117_CR3","doi-asserted-by":"publisher","first-page":"1421","DOI":"10.1148\/rg.2018180041","volume":"38","author":"Y Nagayama","year":"2018","unstructured":"Nagayama Y, Oda S, Nakaura T, Tsuji A, Urata J, Furusawa M, Utsunomiya D, Funama Y, Kidoh M, Yamashita Y. Radiation dose reduction at pediatric CT: use of low tube voltage and iterative reconstruction. Radiographics. 2018;38:1421\u201340.","journal-title":"Radiographics"},{"key":"1117_CR4","doi-asserted-by":"publisher","DOI":"10.1007\/s12194-026-01038-w","author":"T Masuda","year":"2026","unstructured":"Masuda T, Funama Y, Nakaura T. Contemporary strategies for dose optimization in pediatric congenital heart disease CT: size-specific acquisition and detector-level advances. Radiol Phys Technol. 2026. https:\/\/doi.org\/10.1007\/s12194-026-01038-w.","journal-title":"Radiol Phys Technol"},{"key":"1117_CR5","doi-asserted-by":"publisher","first-page":"1347","DOI":"10.1007\/s00247-014-3027-8","volume":"44","author":"T Niemann","year":"2014","unstructured":"Niemann T, Henry S, Duhamel A, Faivre JB, Deschildre A, Colas L, et al. Pediatric chest CT at 70 kVp: a feasibility study in 129 children. Pediatr Radiol. 2014;44:1347\u201357.","journal-title":"Pediatr Radiol"},{"key":"1117_CR6","doi-asserted-by":"publisher","first-page":"20150784","DOI":"10.1259\/bjr.20150184","volume":"89","author":"J Shi","year":"2016","unstructured":"Shi J, Xu D, Nie P, Li Y, Yu M. Evaluation of chest CT scan in low-weight children with ultralow tube voltage (70 kVp) combined with flash scan technique. Br J Radiol. 2016;89:20150784.","journal-title":"Br J Radiol"},{"key":"1117_CR7","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1016\/j.ejmp.2015.12.005","volume":"32","author":"T Shimonobo","year":"2016","unstructured":"Shimonobo T, Funama Y, Utsunomiya D, Nakaura T, Oda S, Kiguchi M, Masuda T, Sakabe D, Yamashita Y, Awai K. Low-tube-voltage selection for non-contrast-enhanced CT: comparison of the radiation dose in pediatric and adult phantoms. Phys Med. 2016;32:197\u2013201.","journal-title":"Phys Med"},{"key":"1117_CR8","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1002\/acm2.12192","volume":"18","author":"T Masuda","year":"2017","unstructured":"Masuda T, Funama Y, Kiguchi M, Osawa K, Suzuki S, Oku T, et al. Relationship between the radiation doses at nonenhanced CT studies using different tube voltages and automatic tube current modulation during anthropomorphic phantoms of young children. J Appl Clin Med Phys. 2017;18:232\u201343.","journal-title":"J Appl Clin Med Phys"},{"key":"1117_CR9","doi-asserted-by":"publisher","first-page":"1197","DOI":"10.1007\/s00247-024-05947-z","volume":"54","author":"T Masuda","year":"2024","unstructured":"Masuda T, Kiguchi M, Fujioka C, Oku T, Ishibashi T, Katsunuma Y, Yoshitake T, Abe S, Awai K. Comparison of pediatric lens scattered dose measurements between axial 40-mm and helical 160-mm detector width computed tomography scan modes. Pediatr Radiol. 2024;54:1197\u2013204.","journal-title":"Pediatr Radiol"},{"key":"1117_CR10","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.1093\/rpd\/ncae165","volume":"200","author":"T Masuda","year":"2024","unstructured":"Masuda T, Kiguchi M, Fujioka C, Oku T, Ishibashi T, Katsunuma Y, Yoshitake T, Abe S, Awai K. Comparison of the equivalent doses of the eye lenses, thyroid, and mammary gland among three pediatric and one adult anthropomorphic phantom during the chest CT examinations using a 40\u00a0mm volume helical scan. Radiat Prot Dosim. 2024;200:1391\u20137.","journal-title":"Radiat Prot Dosim"},{"key":"1117_CR11","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1002\/acm2.13171","volume":"22","author":"Y Matsunaga","year":"2021","unstructured":"Matsunaga Y, Haba T, Asada Y, Kobayashi M, Suzuki S, Chida K. Fetal radiation dose of four tube voltages in abdominal CT examinations during pregnancy: a phantom study. J Appl Clin Med Phys. 2021;22:178\u201384.","journal-title":"J Appl Clin Med Phys"},{"key":"1117_CR12","doi-asserted-by":"publisher","first-page":"W54","DOI":"10.2214\/AJR.07.2017","volume":"190","author":"CA Coursey","year":"2008","unstructured":"Coursey CA, Frush DP, Yoshizumi T, Toncheva G, Nguyen G, Greenberg SB. Pediatric chest MDCT using tube current modulation: effect on radiation dose with breast shielding. AJR Am J Roentgenol. 2008;190:W54\u201361.","journal-title":"AJR Am J Roentgenol"},{"key":"1117_CR13","doi-asserted-by":"publisher","first-page":"407","DOI":"10.2214\/ajr.180.2.1800407","volume":"180","author":"BL Fricke","year":"2003","unstructured":"Fricke BL, Donnelly LF, Frush DP, Yoshizumi T, Varchena V, Nguyen G, Thomas KE. In-plane bismuth breast shields for pediatric CT: effects on radiation dose and image quality using experimental and clinical data. AJR Am J Roentgenol. 2003;180:407\u201311.","journal-title":"AJR Am J Roentgenol"}],"container-title":["Radiological Physics and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-026-01117-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12194-026-01117-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12194-026-01117-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T08:07:00Z","timestamp":1788595620000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12194-026-01117-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,7]]},"references-count":13,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,9]]}},"alternative-id":["1117"],"URL":"https:\/\/doi.org\/10.1007\/s12194-026-01117-y","relation":{},"ISSN":["1865-0333","1865-0341"],"issn-type":[{"value":"1865-0333","type":"print"},{"value":"1865-0341","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,7]]},"assertion":[{"value":"13 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 July 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 July 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 August 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that they have no competing interests.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was performed using a commercially available anthropomorphic phantom and did not involve human participants or animals.","order":3,"name":"Ethics","label":"Human and animal participate","group":{"name":"EthicsHeading","label":"Declarations"}}]}}