{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T15:40:06Z","timestamp":1775144406404,"version":"3.50.1"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2024,10,18]],"date-time":"2024-10-18T00:00:00Z","timestamp":1729209600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,10,18]],"date-time":"2024-10-18T00:00:00Z","timestamp":1729209600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100009938","name":"University of Denver","doi-asserted-by":"publisher","award":["84993-142235"],"award-info":[{"award-number":["84993-142235"]}],"id":[{"id":"10.13039\/100009938","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J. Cardiovasc. Transl. Res."],"published-print":{"date-parts":[[2024,12]]},"DOI":"10.1007\/s12265-024-10528-4","type":"journal-article","created":{"date-parts":[[2024,10,18]],"date-time":"2024-10-18T15:03:02Z","timestamp":1729263782000},"page":"1338-1346","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Adaptation of Aortic Bioprosthetic Valves for Pulmonary Position: Comparative Analysis of Transcatheter and Surgical Valves"],"prefix":"10.1007","volume":"17","author":[{"given":"Mina","family":"Shafiei","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dong","family":"Qiu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9769-9342","authenticated-orcid":false,"given":"Ali N.","family":"Azadani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,10,18]]},"reference":[{"issue":"1","key":"10528_CR1","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1038\/nrcardio.2010.166","volume":"8","author":"T Van Der Bom","year":"2011","unstructured":"Van Der Bom T, et al. The changing epidemiology of congenital heart disease. Nat Rev Cardiol. 2011;8(1):50\u201360.","journal-title":"Nat Rev Cardiol"},{"key":"10528_CR2","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1161\/CIRCULATIONAHA.116.023370","volume":"134","author":"RA Krasuski","year":"2016","unstructured":"Krasuski RA, Bashore TM. Congenital heart disease epidemiology in the United States: blindly feeling for the charging elephant. Circulation. 2016;134:110\u20133.","journal-title":"Circulation"},{"issue":"4","key":"10528_CR3","doi-asserted-by":"publisher","first-page":"327","DOI":"10.2459\/JCM.0b013e32821626ce","volume":"9","author":"S-M Yuan","year":"2008","unstructured":"Yuan S-M, et al. Right ventricular outflow tract reconstruction: valved conduit of choice and clinical outcomes. J Cardiovasc Med. 2008;9(4):327\u201337.","journal-title":"J Cardiovasc Med"},{"issue":"2","key":"10528_CR4","doi-asserted-by":"publisher","first-page":"630","DOI":"10.3390\/jcm13020630","volume":"13","author":"D Galzerano","year":"2024","unstructured":"Galzerano D, et al. The Ross Procedure: Imaging, Outcomes and Future Directions in Aortic Valve Replacement. J Clin Med. 2024;13(2):630.","journal-title":"J Clin Med"},{"issue":"8","key":"10528_CR5","doi-asserted-by":"publisher","first-page":"1252","DOI":"10.1016\/j.amjcard.2015.07.043","volume":"116","author":"JM Oliver","year":"2015","unstructured":"Oliver JM, et al. Risk factors for prosthetic pulmonary valve failure in patients with congenital heart disease. Am J Cardiol. 2015;116(8):1252\u20136.","journal-title":"Am J Cardiol"},{"issue":"1","key":"10528_CR6","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1016\/j.jacc.2021.10.031","volume":"79","author":"DB McElhinney","year":"2022","unstructured":"McElhinney DB, et al. Reintervention and survival after transcatheter pulmonary valve replacement. J Am Coll Cardiol. 2022;79(1):18\u201332.","journal-title":"J Am Coll Cardiol"},{"issue":"9239","key":"10528_CR7","doi-asserted-by":"publisher","first-page":"1403","DOI":"10.1016\/S0140-6736(00)02844-0","volume":"356","author":"P Bonhoeffer","year":"2000","unstructured":"Bonhoeffer P, et al. Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction. Lancet. 2000;356(9239):1403\u20135.","journal-title":"Lancet"},{"issue":"22","key":"10528_CR8","doi-asserted-by":"publisher","first-page":"1960","DOI":"10.1161\/CIRCULATIONAHA.114.013588","volume":"131","author":"JP Cheatham","year":"2015","unstructured":"Cheatham JP, et al. Clinical and hemodynamic outcomes up to 7 years after transcatheter pulmonary valve replacement in the US melody valve investigational device exemption trial. Circulation. 2015;131(22):1960\u201370.","journal-title":"Circulation"},{"issue":"24","key":"10528_CR9","doi-asserted-by":"publisher","first-page":"2847","DOI":"10.1016\/j.jacc.2020.10.041","volume":"76","author":"S Shahanavaz","year":"2020","unstructured":"Shahanavaz S, et al. Transcatheter pulmonary valve replacement with the Sapien prosthesis. J Am Coll Cardiol. 2020;76(24):2847\u201358.","journal-title":"J Am Coll Cardiol"},{"issue":"19","key":"10528_CR10","doi-asserted-by":"publisher","first-page":"1920","DOI":"10.1016\/j.jcin.2018.06.001","volume":"11","author":"D Kenny","year":"2018","unstructured":"Kenny D, et al. 3-year outcomes of the Edwards SAPIEN transcatheter heart valve for conduit failure in the pulmonary position from the COMPASSION multicenter clinical trial. JACC Cardiovasc Interv. 2018;11(19):1920\u20139.","journal-title":"JACC Cardiovasc Interv"},{"issue":"1","key":"10528_CR11","first-page":"130","volume":"11","author":"S Hascoet","year":"2019","unstructured":"Hascoet S, et al. Early outcomes of percutaneous pulmonary valve implantation using the Edwards SAPIEN 3 transcatheter heart valve system. Arch Cardiovasc Dis Suppl. 2019;11(1):130\u20131.","journal-title":"Arch Cardiovasc Dis Suppl"},{"issue":"16","key":"10528_CR12","doi-asserted-by":"publisher","first-page":"1642","DOI":"10.1016\/j.jcin.2018.05.051","volume":"11","author":"MH Martin","year":"2018","unstructured":"Martin MH, et al. Safety and feasibility of melody transcatheter pulmonary valve replacement in the native right ventricular outflow tract: a multicenter pediatric heart network scholar study. JACC Cardiovasc Interv. 2018;11(16):1642\u201350.","journal-title":"JACC Cardiovasc Interv"},{"issue":"17","key":"10528_CR13","doi-asserted-by":"publisher","first-page":"1763","DOI":"10.1016\/j.jcin.2017.05.034","volume":"10","author":"L Bergersen","year":"2017","unstructured":"Bergersen L, et al. Harmony feasibility trial: acute and short-term outcomes with a self-expanding transcatheter pulmonary valve. JACC Cardiovasc Interv. 2017;10(17):1763\u201373.","journal-title":"JACC Cardiovasc Interv"},{"issue":"6","key":"10528_CR14","doi-asserted-by":"publisher","first-page":"1125","DOI":"10.1002\/ccd.27581","volume":"91","author":"EM Zahn","year":"2018","unstructured":"Zahn EM, et al. First human implant of the Alterra Adaptive PrestentTM: A new self-expanding device designed to remodel the right ventricular outflow tract. Catheter Cardiovasc Interv. 2018;91(6):1125\u20139.","journal-title":"Catheter Cardiovasc Interv"},{"key":"10528_CR15","doi-asserted-by":"publisher","first-page":"101369","DOI":"10.1016\/j.ppedcard.2021.101369","volume":"61","author":"S Shahanavaz","year":"2021","unstructured":"Shahanavaz S, et al. Emerging solutions for the dilated native right ventricular outflow tract. Prog Pediatr Cardiol. 2021;61:101369.","journal-title":"Prog Pediatr Cardiol"},{"issue":"5","key":"10528_CR16","doi-asserted-by":"publisher","first-page":"1333","DOI":"10.1016\/j.jtcvs.2016.06.064","volume":"152","author":"R Nomoto","year":"2016","unstructured":"Nomoto R, et al. Outcome and performance of bioprosthetic pulmonary valve replacement in patients with congenital heart disease. J Thorac Cardiovasc Surg. 2016;152(5):1333\u20131342.e3.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"11","key":"10528_CR17","doi-asserted-by":"publisher","first-page":"E357","DOI":"10.1111\/aor.13290","volume":"42","author":"M Barakat","year":"2018","unstructured":"Barakat M, Dvir D, Azadani AN. Fluid dynamic characterization of transcatheter aortic valves using particle image velocimetry. Artif Organs. 2018;42(11):E357\u201368.","journal-title":"Artif Organs"},{"issue":"1","key":"10528_CR18","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1510\/icvts.2009.225144","volume":"11","author":"AN Azadani","year":"2010","unstructured":"Azadani AN, et al. Transcatheter aortic valves inadequately relieve stenosis in small degenerated bioprostheses. Interact Cardiovasc Thorac Surg. 2010;11(1):70\u20137.","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"10528_CR19","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.jbiomech.2018.05.020","volume":"76","author":"M Abbasi","year":"2018","unstructured":"Abbasi M, et al. High resolution three-dimensional strain mapping of bioprosthetic heart valves using digital image correlation. J Biomech. 2018;76:27\u201334.","journal-title":"J Biomech"},{"key":"10528_CR20","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1007\/s10439-018-02129-5","volume":"47","author":"M Abbasi","year":"2019","unstructured":"Abbasi M, et al. A non-invasive material characterization framework for bioprosthetic heart valves. Ann Biomed Eng. 2019;47:97\u2013112.","journal-title":"Ann Biomed Eng"},{"key":"10528_CR21","doi-asserted-by":"publisher","DOI":"10.1115\/1.2244578","volume-title":"Dynamic simulation pericardial bioprosthetic heart valve function","author":"H Kim","year":"2006","unstructured":"Kim, H., et al., Dynamic simulation pericardial bioprosthetic heart valve function. 2006."},{"issue":"22","key":"10528_CR22","doi-asserted-by":"publisher","first-page":"2264","DOI":"10.1161\/CIRCULATIONAHA.110.946343","volume":"122","author":"P Moons","year":"2010","unstructured":"Moons P, et al. Temporal trends in survival to adulthood among patients born with congenital heart disease from 1970 to 1992 in Belgium. Circulation. 2010;122(22):2264\u201372.","journal-title":"Circulation"},{"issue":"3","key":"10528_CR23","doi-asserted-by":"publisher","first-page":"1051","DOI":"10.1016\/j.jtcvs.2019.05.084","volume":"159","author":"H Pragt","year":"2020","unstructured":"Pragt H, et al. Pulmonary versus aortic pressure behavior of a bovine pericardial valve. J Thorac Cardiovasc Surg. 2020;159(3):1051\u20131059.e1.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"4","key":"10528_CR24","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1016\/j.hlc.2009.10.009","volume":"19","author":"JG Kwak","year":"2010","unstructured":"Kwak JG, et al. Mid-term results of the Hancock II valve and Carpentier-Edward Perimount valve in the pulmonary portion in congenital heart disease. Heart Lung Circ. 2010;19(4):243\u20136.","journal-title":"Heart Lung Circ"},{"issue":"2","key":"10528_CR25","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1016\/j.jtcvs.2010.12.020","volume":"142","author":"C Lee","year":"2011","unstructured":"Lee C, et al. Durability of bioprosthetic valves in the pulmonary position: long-term follow-up of 181 implants in patients with congenital heart disease. J Thorac Cardiovasc Surg. 2011;142(2):351\u20138.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"6","key":"10528_CR26","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1080\/17434440.2020.1775578","volume":"17","author":"W Alkashkari","year":"2020","unstructured":"Alkashkari W, et al. Transcatheter pulmonary valve replacement in pediatric patients. Expert Rev Med Devices. 2020;17(6):541\u201354.","journal-title":"Expert Rev Med Devices"},{"issue":"5","key":"10528_CR27","doi-asserted-by":"publisher","first-page":"990","DOI":"10.1002\/ccd.29862","volume":"98","author":"R Le Ruz","year":"2021","unstructured":"Le Ruz R, et al. Edwards SAPIEN XT transcatheter pulmonary valve implantation: 5-year follow-up in a French Registry. Catheter Cardiovasc Interv. 2021;98(5):990\u20139.","journal-title":"Catheter Cardiovasc Interv"},{"issue":"5","key":"10528_CR28","first-page":"100408","volume":"1","author":"K Durongpisitkul","year":"2022","unstructured":"Durongpisitkul K, et al. Outcomes of Transcatheter Pulmonary Valve Replacement and Surgical Pulmonary Valve Replacement: A Cohort Analysis. J Soc Cardiovasc Angiogr Interv. 2022;1(5):100408.","journal-title":"J Soc Cardiovasc Angiogr Interv"},{"issue":"3","key":"10528_CR29","first-page":"421","volume":"15","author":"EE Roselli","year":"2006","unstructured":"Roselli EE, Smedira NG, Blackstone EH. Failure modes of the Carpentier-Edwards pericardial bioprosthesis in the aortic position. J Heart Valve Dis. 2006;15(3):421\u20137. discussion 427","journal-title":"J Heart Valve Dis"},{"issue":"4","key":"10528_CR30","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1161\/CIRCULATIONAHA.105.549311","volume":"114","author":"RA Manji","year":"2006","unstructured":"Manji RA, et al. Glutaraldehyde-fixed bioprosthetic heart valve conduits calcify and fail from xenograft rejection. Circulation. 2006;114(4):318\u201327.","journal-title":"Circulation"},{"key":"10528_CR31","first-page":"124","volume":"19","author":"CS Park","year":"2010","unstructured":"Park CS, et al. Anti-Gal immune response following porcine bioprosthesis implantation in children. J Heart Valve Dis. 2010;19:124\u201330.","journal-title":"J Heart Valve Dis"},{"key":"10528_CR32","doi-asserted-by":"publisher","first-page":"1258","DOI":"10.1007\/s00392-019-01461-7","volume":"108","author":"C Pellegrini","year":"2019","unstructured":"Pellegrini C, et al. One year VARC-2-defined clinical outcomes after transcatheter aortic valve implantation with the SAPIEN 3. Clin Res Cardiol. 2019;108:1258\u201365.","journal-title":"Clin Res Cardiol"},{"issue":"3","key":"10528_CR33","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1093\/eurheartj\/ehad663","volume":"45","author":"S Hasco\u00ebt","year":"2024","unstructured":"Hasco\u00ebt S, et al. Outcomes of transcatheter pulmonary SAPIEN 3 valve implantation: an international registry. Eur Heart J. 2024;45(3):198\u2013210.","journal-title":"Eur Heart J"},{"issue":"5","key":"10528_CR34","first-page":"927","volume":"51","author":"K Vahidkhah","year":"2017","unstructured":"Vahidkhah K, et al. Valve thrombosis following transcatheter aortic valve replacement: significance of blood stasis on the leaflets. Eur J Cardiothorac Surg. 2017;51(5):927\u201335.","journal-title":"Eur J Cardiothorac Surg"},{"issue":"3","key":"10528_CR35","doi-asserted-by":"publisher","first-page":"751","DOI":"10.1016\/j.athoracsur.2017.02.052","volume":"104","author":"K Vahidkhah","year":"2017","unstructured":"Vahidkhah K, et al. Blood stasis on transcatheter valve leaflets and implications for valve-in-valve leaflet thrombosis. Ann Thorac Surg. 2017;104(3):751\u20139.","journal-title":"Ann Thorac Surg"},{"issue":"7","key":"10528_CR36","doi-asserted-by":"publisher","first-page":"811","DOI":"10.4244\/EIJ-D-17-00094","volume":"13","author":"K Vahidkhah","year":"2017","unstructured":"Vahidkhah K, et al. Effect of reduced cardiac output on blood stasis on transcatheter aortic valve leaflets: implications for valve thrombosis. EuroIntervention. 2017;13(7):811\u20139.","journal-title":"EuroIntervention"},{"issue":"12","key":"10528_CR37","doi-asserted-by":"publisher","first-page":"1688.e13","DOI":"10.1016\/j.cjca.2018.08.025","volume":"34","author":"J Kellermair","year":"2018","unstructured":"Kellermair J, et al. First report of an acute, obstructive thrombosis of a Melody valve used for transcatheter pulmonary replacement. Can J Cardiol. 2018;34(12):1688.e13\u20135.","journal-title":"Can J Cardiol"},{"issue":"13","key":"10528_CR38","doi-asserted-by":"publisher","first-page":"e119","DOI":"10.1016\/j.jcin.2017.04.009","volume":"10","author":"PA Verhoeven","year":"2017","unstructured":"Verhoeven PA, et al. Noninfective transcatheter pulmonary valve thrombosis: a rare cause of post-implantation pulmonary valve obstruction. JACC Cardiovasc Interv. 2017;10(13):e119\u201322.","journal-title":"JACC Cardiovasc Interv"},{"issue":"5","key":"10528_CR39","doi-asserted-by":"publisher","first-page":"925","DOI":"10.1002\/ccd.27183","volume":"92","author":"M Riahi","year":"2018","unstructured":"Riahi M, et al. Early leaflet thrombosis complicating transcatheter implantation of a Sapien 3 valve in a native right ventricular outflow tract. Catheter Cardiovasc Interv. 2018;92(5):925\u20139.","journal-title":"Catheter Cardiovasc Interv"},{"issue":"10","key":"10528_CR40","first-page":"2047","volume":"14","author":"M Hammadah","year":"2021","unstructured":"Hammadah M, et al. Hypoattenuated leaflet thickening after transcatheter pulmonary valve replacement with the SAPIEN 3 valve. Cardiovasc Imaging. 2021;14(10):2047\u20138.","journal-title":"Cardiovasc Imaging"},{"issue":"1","key":"10528_CR41","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1093\/icvts\/ivz213","volume":"30","author":"F Khodaee","year":"2020","unstructured":"Khodaee F, et al. Incomplete expansion of transcatheter aortic valves is associated with propensity for valve thrombosis. Interact Cardiovasc Thorac Surg. 2020;30(1):39\u201346.","journal-title":"Interact Cardiovasc Thorac Surg"}],"container-title":["Journal of Cardiovascular Translational Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12265-024-10528-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12265-024-10528-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12265-024-10528-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,11]],"date-time":"2024-12-11T22:37:26Z","timestamp":1733956646000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12265-024-10528-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,18]]},"references-count":41,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2024,12]]}},"alternative-id":["10528"],"URL":"https:\/\/doi.org\/10.1007\/s12265-024-10528-4","relation":{},"ISSN":["1937-5387","1937-5395"],"issn-type":[{"value":"1937-5387","type":"print"},{"value":"1937-5395","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,10,18]]},"assertion":[{"value":"13 December 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 May 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 October 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"No human studies were carried out by the authors for this article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human Subjects"}},{"value":"No animal studies were carried out by the authors for this article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Animal Studies"}},{"value":"The authors have no conflict of interest to declare.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}]}}