{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,24]],"date-time":"2025-10-24T17:17:49Z","timestamp":1761326269377,"version":"build-2065373602"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2025,8,20]],"date-time":"2025-08-20T00:00:00Z","timestamp":1755648000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,8,20]],"date-time":"2025-08-20T00:00:00Z","timestamp":1755648000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Breast Cancer"],"published-print":{"date-parts":[[2025,11]]},"DOI":"10.1007\/s12282-025-01763-x","type":"journal-article","created":{"date-parts":[[2025,8,20]],"date-time":"2025-08-20T15:19:17Z","timestamp":1755703157000},"page":"1375-1383","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Prospective randomized-controlled trial: efficacy of 37\u00a0\u00b0C-preheated thermoplastic elastomer (TPE) bolus in postoperative radiotherapy for breast cancer patients"],"prefix":"10.1007","volume":"32","author":[{"given":"Lihua","family":"Zhang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bo","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rong","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jie","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rong","family":"Cai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fengbin","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fating","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zixuan","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lin","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juan","family":"Ma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaowei","family":"Yao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qiuxia","family":"Hu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Linlin","family":"Xu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jian","family":"Zang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fei","family":"Bai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lina","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,8,20]]},"reference":[{"key":"1763_CR1","doi-asserted-by":"publisher","first-page":"1941","DOI":"10.1002\/ijc.31937","volume":"144","author":"J Ferlay","year":"2019","unstructured":"Ferlay J, Colombet M, Soerjomataram I, Mathers C, Parkin DM, Pi\u00f1eros M, et al. Estimating the global cancer incidence and mortality in 2018: GLOBOCAN sources and methods. Int J Cancer. 2019;144:1941\u201353. https:\/\/doi.org\/10.1002\/ijc.31937.","journal-title":"Int J Cancer"},{"key":"1763_CR2","doi-asserted-by":"publisher","first-page":"277","DOI":"10.3322\/canjclin.52.5.277","volume":"52","author":"M Morrow","year":"2002","unstructured":"Morrow M, Strom EA, Bassett LW, Dershaw DD, Fowble B, Giuliano A, et al. Standard for breast conservation therapy in the management of invasive breast carcinoma. CA Cancer J Clin. 2002;52:277\u2013300. https:\/\/doi.org\/10.3322\/canjclin.52.5.277.","journal-title":"CA Cancer J Clin"},{"key":"1763_CR3","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1097\/SLA.0b013e3182263bb0","volume":"254","author":"CC Greenberg","year":"2011","unstructured":"Greenberg CC, Lipsitz SR, Hughes ME, Edge SB, Theriault R, Wilson JL, et al. Institutional variation in the surgical treatment of breast cancer: a study of the NCCN. Ann Surg. 2011;254:339\u201345. https:\/\/doi.org\/10.1097\/SLA.0b013e3182263bb0.","journal-title":"Ann Surg"},{"key":"1763_CR4","doi-asserted-by":"publisher","first-page":"956","DOI":"10.1056\/NEJM199710023371402","volume":"337","author":"J Ragaz","year":"1997","unstructured":"Ragaz J, Jackson SM, Le N, Plenderleith IH, Spinelli JJ, Basco VE, et al. Adjuvant radiotherapy and chemotherapy in node-positive premenopausal women with breast cancer. N Engl J Med. 1997;337:956\u201362. https:\/\/doi.org\/10.1056\/NEJM199710023371402.","journal-title":"N Engl J Med"},{"key":"1763_CR5","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1016\/j.radonc.2007.02.001","volume":"82","author":"M Overgaard","year":"2007","unstructured":"Overgaard M, Nielsen HM, Overgaard J. Is the benefit of postmastectomy irradiation limited to patients with four or more positive nodes, as recommended in international consensus reports? A subgroup analysis of the DBCG 82 b&c randomized trials. Radiother Oncol. 2007;82:247\u201353. https:\/\/doi.org\/10.1016\/j.radonc.2007.02.001.","journal-title":"Radiother Oncol"},{"key":"1763_CR6","first-page":"199","volume":"11","author":"L Gao","year":"2011","unstructured":"Gao L, Wu Y, Li Y, Huang J. Application of breast bracket in intensity-modulated radiation therapy after breast-conserving surgery for breast cancer. Lingnan Mod Clin Surg. 2011;11:199\u2013201.","journal-title":"Lingnan Mod Clin Surg"},{"key":"1763_CR7","first-page":"1278","volume":"30","author":"F Lei","year":"2014","unstructured":"Lei F, Gu D, Bai Y, Li M, Liu Y, Liu X. Volumetric rotational intensity modulated radiotherapy and conventional radiotherapy in the early breast cancer after breast conserving surgery. J Pract Lab. 2014;30:1278\u201380.","journal-title":"J Pract Lab"},{"issue":"12","key":"1763_CR8","doi-asserted-by":"publisher","first-page":"3091","DOI":"10.1118\/1.1625116","volume":"30","author":"N Dogan","year":"2003","unstructured":"Dogan N, Glasgow GP. Surface and build-up region dosimetry for obliquely incident intensity-modulated radiotherapy 6 MV x rays. Med Phys. 2003;30(12):3091\u20136. https:\/\/doi.org\/10.1118\/1.1625116.","journal-title":"Med Phys"},{"key":"1763_CR9","doi-asserted-by":"publisher","first-page":"5937","DOI":"10.1088\/0031-9155\/51\/22\/015","volume":"51","author":"CF Behrens","year":"2006","unstructured":"Behrens CF. Dose build-up behind air cavities for Co-60, 4, 6 and 8 MV. Measurements Monte Carlo simulations. Phys Med Biol. 2006;51:5937\u201350. https:\/\/doi.org\/10.1088\/0031-9155\/51\/22\/015.","journal-title":"Phys Med Biol"},{"key":"1763_CR10","doi-asserted-by":"publisher","first-page":"1266","DOI":"10.1118\/1.2710951","volume":"34","author":"HF Xiang","year":"2007","unstructured":"Xiang HF, Song JS, Chin DW, Cormack RA, Tishler RB, Makrigiorgos GM, et al. Build-up and surface dose measurements on phantoms using micro-MOSFET in 6 and 10 MV x-ray beams and comparisons with Monte Carlo calculations. Med Phys. 2007;34:1266\u201373. https:\/\/doi.org\/10.1118\/1.2710951.","journal-title":"Med Phys"},{"key":"1763_CR11","doi-asserted-by":"publisher","first-page":"2627","DOI":"10.1039\/c9tb02967b","volume":"8","author":"Y Hou","year":"2020","unstructured":"Hou Y, Song Y, Sun X, Jiang Y, He M, Li Y, et al. Multifunctional composite hydrogel bolus with combined self-healing, antibacterial and adhesive functions for radiotherapy. J Mater Chem B. 2020;8:2627\u201335. https:\/\/doi.org\/10.1039\/c9tb02967b.","journal-title":"J Mater Chem B"},{"key":"1763_CR12","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/j.clon.2006.10.004","volume":"19","author":"TT Vu","year":"2007","unstructured":"Vu TT, Pignol JP, Rakovitch E, Spayne J, Paszat L. Variability in radiation oncologists\u2019 opinion on the indication of a bolus in post-mastectomy radiotherapy: an international survey. Clin Oncol. 2007;19:115\u20139. https:\/\/doi.org\/10.1016\/j.clon.2006.10.004.","journal-title":"Clin Oncol"},{"key":"1763_CR13","doi-asserted-by":"publisher","first-page":"124","DOI":"10.2478\/raon-2024-0001","volume":"58","author":"J Li","year":"2024","unstructured":"Li J, Yang L, Yao X, Xu L, Zhao L, Bai F. A retrospective study on improving the accuracy of radiotherapy for breast cancer patients with lymph node metastasis using Styrofoam. Radiol Oncol. 2024;58:124\u201332. https:\/\/doi.org\/10.2478\/raon-2024-0001.","journal-title":"Radiol Oncol"},{"key":"1763_CR14","first-page":"1","volume-title":"On target: ensuring geometric accuracy in radiotherapy. A Joint RCR\/IPEM\/SCoR report","author":"P Hoskin","year":"2008","unstructured":"Hoskin P, Gaze M, Greener T. On target: ensuring geometric accuracy in radiotherapy. A Joint RCR\/IPEM\/SCoR report. London: Royal College of Radiologists; 2008. p. 1\u201378."},{"key":"1763_CR15","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1053\/j.semradonc.2003.10.003","volume":"14","author":"M van Herk","year":"2004","unstructured":"van Herk M. Errors and margins in radiotherapy. Semin Radiat Oncol. 2004;14:52\u201364. https:\/\/doi.org\/10.1053\/j.semradonc.2003.10.003.","journal-title":"Semin Radiat Oncol"},{"key":"1763_CR16","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1186\/s13014-025-02609-8","volume":"20","author":"F Yang","year":"2025","unstructured":"Yang F, Li JL, Li B, Zhang L, Li J, Yao X, et al. Effectiveness of personalized open-face mask combined with styrofoam fixation in radiotherapy treatment of head and neck cancers: a prospective randomized controlled trial. Radiat Oncol. 2025;20:34. https:\/\/doi.org\/10.1186\/s13014-025-02609-8.","journal-title":"Radiat Oncol"},{"issue":"10","key":"1763_CR17","doi-asserted-by":"publisher","first-page":"2593","DOI":"10.1088\/0031-9155\/53\/10\/010","volume":"53","author":"SH Hsu","year":"2008","unstructured":"Hsu SH, Roberson PL, Chen Y, Marsh RB, Pierce LJ, Moran JM. Assessment of skin dose for breast chest wall radiotherapy as a function of bolus material. Phys Med Biol. 2008;53(10):2593\u2013606. https:\/\/doi.org\/10.1088\/0031-9155\/53\/10\/010.","journal-title":"Phys Med Biol"},{"key":"1763_CR18","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1016\/j.breast.2022.11.008","volume":"66","author":"G Pan","year":"2022","unstructured":"Pan G, Dai G, Wu X, Wang X, Xie L, Xu S, et al. Application of thermoplastic elastomer (TPE) bolus in postmastectomy radiotherapy. Breast. 2022;66:317\u201323. https:\/\/doi.org\/10.1016\/j.breast.2022.11.008.","journal-title":"Breast"},{"key":"1763_CR19","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0168063","volume":"11","author":"SY Park","year":"2016","unstructured":"Park SY, Choi CH, Park JM, Chun M, Han JH, Kim J. A patient-specific polylactic acid bolus made by a 3D printer for breast cancer radiation therapy. PLoS ONE. 2016;11: e0168063. https:\/\/doi.org\/10.1371\/journal.pone.0168063.","journal-title":"PLoS ONE"},{"key":"1763_CR20","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1016\/j.prro.2017.12.008","volume":"8","author":"JL Robar","year":"2018","unstructured":"Robar JL, Moran K, Allan J, Clancey J, Joseph T, Chytyk-Praznik K, et al. Intrapatient study comparing 3D printed bolus versus standard vinyl gel sheetbolus for postmastectomy chest wall radiation therapy. Pract Radiat Oncol. 2018;8:221\u20139. https:\/\/doi.org\/10.1016\/j.prro.2017.12.008.","journal-title":"Pract Radiat Oncol"},{"key":"1763_CR21","first-page":"83","volume":"32","author":"C Li","year":"2011","unstructured":"Li C, Hu J, Zhang A, Xu L. Effect of tissue equivalent compensation film and human air gap on surface dose of 6MV X-ray. Chin Med Equ J. 2011;32:83\u20134.","journal-title":"Chin Med Equ J"},{"key":"1763_CR22","doi-asserted-by":"publisher","first-page":"1235","DOI":"10.1016\/j.ijrobp.2009.12.021","volume":"78","author":"R Topolnjak","year":"2010","unstructured":"Topolnjak R, Sonke JJ, Nijkamp J, Rasch C, Minkema D, Remeijer P, et al. Breast patient setup error assessment: comparison of electronic portal image devices and cone-beam computed tomography matching results. Int J Radiat Oncol Biol Phys. 2010;78:1235\u201343. https:\/\/doi.org\/10.1016\/j.ijrobp.2009.12.021.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1763_CR23","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1002\/jmrs.180","volume":"63","author":"V Batumalai","year":"2016","unstructured":"Batumalai V, Phan P, Choong C, Holloway L, Delaney GP. Comparison of setup accuracy of three different image assessment methods for tangential breast radiotherapy. J Med Radiat Sci. 2016;63:224\u201331. https:\/\/doi.org\/10.1002\/jmrs.180.","journal-title":"J Med Radiat Sci"},{"issue":"5","key":"1763_CR24","doi-asserted-by":"publisher","first-page":"2055","DOI":"10.1016\/j.ijrobp.2010.10.070","volume":"82","author":"L Veldeman","year":"2012","unstructured":"Veldeman L, De Gersem W, Speleers B, Truyens B, Van Greveling A, Van den Broecke R, et al. Alternated prone and supine whole-breast irradiation using IMRT: setup precision, respiratory movement and treatment time. Int J Radiat Oncol Biol Phys. 2012;82(5):2055\u201364. https:\/\/doi.org\/10.1016\/j.ijrobp.2010.10.070.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1763_CR25","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1016\/j.ijrobp.2010.02.022","volume":"80","author":"S Offerman","year":"2011","unstructured":"Offerman S, Lamba M, Lavigne R. Effect of breast volume on treatment reproducibility on a tomotherapy unit in the treatment ofbreast cancer. Int J Radiat Oncol Biol Phys. 2011;80:417\u201321.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1763_CR26","doi-asserted-by":"publisher","first-page":"e187","DOI":"10.1016\/j.ijrobp.2010.12.027","volume":"81","author":"R Topolnjak","year":"2011","unstructured":"Topolnjak R, de Ruiter P, Remeijer P, van Vliet-Vroegindeweij C, Rasch C, Sonke JJ. Image-guided radiotherapy for breast cancer patients: surgical clips as surrogate for breast excision cavity. Int J Radiat Oncol Biol Phys. 2011;81:e187\u201395. https:\/\/doi.org\/10.1016\/j.ijrobp.2010.12.027.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1763_CR27","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1016\/j.radonc.2008.10.010","volume":"90","author":"P Jain","year":"2009","unstructured":"Jain P, Marchant T, Green M, Watkins G, Davies J, McCarthy C, et al. Inter-fraction motion and dosimetric consequences during breast intensity-modulated radiotherapy (IMRT). Radiother Oncol. 2009;90:93\u20138. https:\/\/doi.org\/10.1016\/j.radonc.2008.10.010.","journal-title":"Radiother Oncol"},{"key":"1763_CR28","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1186\/s13014-023-02363-9","volume":"18","author":"X Long","year":"2023","unstructured":"Long X, Guo J, Yin Y, Cheng M, Zhang X, Zhang J, et al. A blinded-endpoint, randomized controlled trial of Sanyrene with natural active ingredient for prophylaxis of radiation dermatitis in patients receiving radiotherapy. Radiat Oncol. 2023;18:174. https:\/\/doi.org\/10.1186\/s13014-023-02363-9.","journal-title":"Radiat Oncol"}],"container-title":["Breast Cancer"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12282-025-01763-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12282-025-01763-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12282-025-01763-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,24]],"date-time":"2025-10-24T17:13:17Z","timestamp":1761325997000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12282-025-01763-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,20]]},"references-count":28,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025,11]]}},"alternative-id":["1763"],"URL":"https:\/\/doi.org\/10.1007\/s12282-025-01763-x","relation":{},"ISSN":["1340-6868","1880-4233"],"issn-type":[{"type":"print","value":"1340-6868"},{"type":"electronic","value":"1880-4233"}],"subject":[],"published":{"date-parts":[[2025,8,20]]},"assertion":[{"value":"31 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 August 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was approved by the Ethics Committee of the First Affiliated Hospital of Air Force Medical University (ethical approval number: KY20232162-F-1). Written informed consent was obtained from participants to participate in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}}]}}