{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T16:40:00Z","timestamp":1740156000701,"version":"3.37.3"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2017,8,11]],"date-time":"2017-08-11T00:00:00Z","timestamp":1502409600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Musculoskelet Surg"],"DOI":"10.1007\/s12306-017-0498-4","type":"journal-article","created":{"date-parts":[[2017,8,11]],"date-time":"2017-08-11T08:17:32Z","timestamp":1502439452000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Pedicle screw fixation in thoracolumbar and lumbar spine assisted by lateral fluoroscopic imaging: a study to evaluate the accuracy of screw placement"],"prefix":"10.1007","author":[{"given":"S. P.","family":"Mohanty","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S. N.","family":"Bhat","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0001-5491","authenticated-orcid":false,"given":"M.","family":"Pai Kanhangad","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G. S.","family":"Gosal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2017,8,11]]},"reference":[{"key":"498_CR1","first-page":"45","volume":"203","author":"AD Steffee","year":"1986","unstructured":"Steffee AD, Biscup RS, Sitkowskj DJ (1986) Segmental spine plates with pedicle screw fixation a new internal fixation device for disorders of the lumbar and thoracolumbar spine. Clin Orthop Relat Res 203:45\u201353","journal-title":"Clin Orthop Relat Res"},{"key":"498_CR2","first-page":"2","volume":"15","author":"R Roy-Camille","year":"1976","unstructured":"Roy-Camille R, Saillant G, Berteaux D, Salgado V (1976) Osteosynthesis of thoraco-lumbar spine fractures with metal plates screwed through the vertebral pedicles. Reconstr Surg Traumatol 15:2\u201316","journal-title":"Reconstr Surg Traumatol"},{"key":"498_CR3","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","volume":"15","author":"SD Gertzbein","year":"1990","unstructured":"Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976) 15:11\u201314","journal-title":"Spine (Phila Pa 1976)"},{"issue":"20","key":"498_CR4","doi-asserted-by":"crossref","first-page":"2274S","DOI":"10.1097\/00007632-199410151-00004","volume":"19","author":"MA Yahiro","year":"1994","unstructured":"Yahiro MA (1994) Comprehensive literature review: pedicle screw fixation devices. Spine 19(20):2274S\u20132278S","journal-title":"Spine"},{"issue":"2","key":"498_CR5","doi-asserted-by":"crossref","first-page":"112","DOI":"10.5312\/wjo.v5.i2.112","volume":"5","author":"V Puvanesarajah","year":"2014","unstructured":"Puvanesarajah V, Liauw JA, Lo SF, Lina IA, Witham TF (2014) Techniques and accuracy of thoracolumbar pedicle screw placement. World J Orthop 5(2):112","journal-title":"World J Orthop"},{"key":"498_CR6","doi-asserted-by":"crossref","first-page":"641","DOI":"10.3171\/jns.1995.83.4.0641","volume":"83","author":"IH Kalfas","year":"1995","unstructured":"Kalfas IH, Kormos DW, Murphy MA et al (1995) Application of frameless stereotaxy to pedicle fixation of the spine. J Neurosurg 83:641\u2013647","journal-title":"J Neurosurg"},{"key":"498_CR7","unstructured":"Amiot LP, Lang K, Zippel H, Labelle H (1998) Comparative accuracy between conventional and computer-assisted pedicle screw installation. Presented at the annual meeting of the international society for the study of the lumbar spine, Brussels, Belgium"},{"key":"498_CR8","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1097\/00003086-199809000-00006","volume":"354","author":"P Merloz","year":"1998","unstructured":"Merloz P, Tonetti J, Pittet L et al (1998) Pedicle screw placement using image guided techniques. Clin Orthop 354:39\u201348","journal-title":"Clin Orthop"},{"key":"498_CR9","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1097\/00007632-199702150-00020","volume":"22","author":"O Schwarzenbach","year":"1997","unstructured":"Schwarzenbach O, Berleman U, Jost B et al (1997) Accuracy of computer-assisted pedicle screw placement. An in vivo computed tomography analysis. Spine 22:452\u2013458","journal-title":"Spine"},{"key":"498_CR10","doi-asserted-by":"crossref","first-page":"1254","DOI":"10.1097\/00007632-199706010-00018","volume":"22","author":"T Laine","year":"1997","unstructured":"Laine T, Schlenzka D, M\u00e4kitalo K et al (1997) Improved accuracy of pedicle screw insertion with computer-assisted surgery. Spine 22:1254\u20131258","journal-title":"Spine"},{"key":"498_CR11","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1038\/sj.sc.3100432","volume":"35","author":"FM Maynard","year":"1997","unstructured":"Maynard FM et al (1997) International standards for neurological and functional classification of spinal cord injury. Spinal Cord 35:266\u2013274","journal-title":"Spinal Cord"},{"key":"498_CR12","first-page":"261","volume-title":"Instructional course lectures","author":"JR Cobb","year":"1948","unstructured":"Cobb JR (1948) Outline for the study of scoliosis. In: Edwards JW (ed) Instructional course lectures, vol 5. The American Academy of Orthopedic Surgeons, Ann Arbor, pp 261\u2013275"},{"key":"498_CR13","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1097\/00007632-199306150-00003","volume":"18","author":"J Mumford","year":"1993","unstructured":"Mumford J, Weinstein JN, Spratt KF, Goel VK (1993) Thoracolumbar burst fractures: the clinical efficacy and outcome of non-operative management. Spine 18:955\u2013970","journal-title":"Spine"},{"key":"498_CR14","doi-asserted-by":"crossref","first-page":"1268","DOI":"10.1097\/00007632-198811000-00011","volume":"13","author":"T Hashimoto","year":"1988","unstructured":"Hashimoto T, Kaneda K, Abumi K (1988) Relationship between traumatic spinal canal stenosis and neurologic deficits in thoracolumbar burst fractures. Spine 13:1268\u20131272","journal-title":"Spine"},{"issue":"4","key":"498_CR15","doi-asserted-by":"crossref","first-page":"541","DOI":"10.2106\/00004623-199072040-00011","volume":"72","author":"JM Olsewski","year":"1990","unstructured":"Olsewski JM, Simmons EH, Kallen FC, Mendel FC, Severin CM, Berens DL (1990) Morphometry of the lumbar spine: anatomical perspectives related to transpedicular fixation. J Bone Joint Surg 72(4):541\u2013549","journal-title":"J Bone Joint Surg"},{"key":"498_CR16","doi-asserted-by":"crossref","first-page":"1458","DOI":"10.2106\/00004623-200010000-00013","volume":"82-A","author":"RW Gaines","year":"2000","unstructured":"Gaines RW (2000) The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 82-A:1458\u20131476","journal-title":"J Bone Joint Surg Am"},{"key":"498_CR17","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1097\/00007632-198801000-00007","volume":"13","author":"MH Krag","year":"1988","unstructured":"Krag MH, Weaver DL, Beynnon BD, Haugh LD (1988) Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation. Spine (Phila Pa 1976) 13:27\u201332","journal-title":"Spine (Phila Pa 1976)"},{"issue":"2","key":"498_CR18","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1097\/00007632-199302000-00005","volume":"18","author":"D Zou","year":"1993","unstructured":"Zou D, Yoo JU, Edwards WT, Donovan DM, Chang KW, Bayley JC, Fredrickson BE, Yuan HA (1993) Mechanics of anatomic reduction of thoracolumbar burst fractures| comparison of distraction versus distraction plus lordosis, in the anatomic reduction of the thoracolumbar burst fracture. Spine 18(2):195\u2013203","journal-title":"Spine"},{"issue":"6","key":"498_CR19","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1097\/00007632-199305000-00003","volume":"18","author":"RM Harrington","year":"1993","unstructured":"Harrington RM, Budorick T, Hoyt J, Anderson PA, Tencer AF (1993) Biomechanics of indirect reduction of bone retropulsed into the spinal canal in vertebral fracture. Spine 18(6):692\u2013699","journal-title":"Spine"},{"issue":"2","key":"498_CR20","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1007\/s12306-011-0111-1","volume":"95","author":"SP Mohanty","year":"2011","unstructured":"Mohanty SP, Bhat SN, Ishwara-Keerthi C (2011) The effect of posterior instrumentation of the spine on canal dimensions and neurological recovery in thoracolumbar and lumbar burst fractures. Musculoskelet Surg 95(2):101\u2013106","journal-title":"Musculoskelet Surg"},{"issue":"4","key":"498_CR21","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1097\/00002517-199608000-00011","volume":"9","author":"CJ Odgers","year":"1996","unstructured":"Odgers CJ, Vaccaro AR, Pollack ME, Cotler JM (1996) Accuracy of pedicle screw placement with the assistance of lateral plain radiography. J Spinal Disord 9(4):334\u2013338","journal-title":"J Spinal Disord"},{"key":"498_CR22","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.1097\/00007632-199606010-00008","volume":"21","author":"WH Castro","year":"1996","unstructured":"Castro WH, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S (1996) Accuracy of pedicle screw placement in lumbar vertebrae. Spine 21:1320\u20131324","journal-title":"Spine"},{"key":"498_CR23","doi-asserted-by":"crossref","first-page":"1012","DOI":"10.1097\/00007632-198809000-00008","volume":"13","author":"JN Weinstein","year":"1998","unstructured":"Weinstein JN, Spratt KF, Spengler D, Brick C (1998) Spinal pedicle fixation: reality and validity of roentgenogram \u2013 based assessment and surgical factors on successful screw placement. Spine 13:1012\u20131016","journal-title":"Spine"}],"container-title":["MUSCULOSKELETAL SURGERY"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12306-017-0498-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s12306-017-0498-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12306-017-0498-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,8,11]],"date-time":"2017-08-11T08:17:46Z","timestamp":1502439466000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s12306-017-0498-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,8,11]]},"references-count":23,"alternative-id":["498"],"URL":"https:\/\/doi.org\/10.1007\/s12306-017-0498-4","relation":{},"ISSN":["2035-5106","2035-5114"],"issn-type":[{"type":"print","value":"2035-5106"},{"type":"electronic","value":"2035-5114"}],"subject":[],"published":{"date-parts":[[2017,8,11]]}}}