{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T08:12:40Z","timestamp":1767859960282,"version":"3.49.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2019,5,30]],"date-time":"2019-05-30T00:00:00Z","timestamp":1559174400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,5,30]],"date-time":"2019-05-30T00:00:00Z","timestamp":1559174400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Musculoskelet Surg"],"published-print":{"date-parts":[[2020,8]]},"DOI":"10.1007\/s12306-019-00612-3","type":"journal-article","created":{"date-parts":[[2019,5,30]],"date-time":"2019-05-30T06:02:33Z","timestamp":1559196153000},"page":"195-200","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Single-use, patient-specific instrumentation technology in knee arthroplasty: a comparative study between standard instrumentation and PSI efficiency system"],"prefix":"10.1007","volume":"104","author":[{"given":"S.","family":"Giannotti","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1276-0624","authenticated-orcid":false,"given":"F.","family":"Sacchetti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Citarelli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"V.","family":"Bottai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N.","family":"Bianchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Agostini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Capanna","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,5,30]]},"reference":[{"key":"612_CR1","doi-asserted-by":"publisher","DOI":"10.1016\/j.pharma.2017.12.002","author":"T Vaillant","year":"2018","unstructured":"Vaillant T et al (2018) Review of patient-specific instrumentation for total knee prosthesis. Ann Pharm Fr. \nhttps:\/\/doi.org\/10.1016\/j.pharma.2017.12.002","journal-title":"Ann Pharm Fr"},{"key":"612_CR2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.16.00496","author":"E Thienpont","year":"2017","unstructured":"Thienpont E et al (2017) Efficacy of patient-specific instruments in total knee arthroplasty. J Bone Joint Surg. \nhttps:\/\/doi.org\/10.2106\/JBJS.16.00496","journal-title":"J Bone Joint Surg"},{"key":"612_CR3","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1097\/00003086-200211000-00003","volume":"404","author":"PF Sharkey","year":"2002","unstructured":"Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM (2002) Insall Award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res 404:7\u201313","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"612_CR4","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/j.arth.2011.07.006","volume":"27","author":"JW Noble Jr","year":"2012","unstructured":"Noble JW Jr, Moore CA, Liu N (2012) The value of patient-matched instrumentation in total knee arthroplasty. J Arthroplasty [Internet] 27(1):153\u2013155. \nhttps:\/\/doi.org\/10.1016\/j.arth.2011.07.006","journal-title":"J Arthroplasty [Internet]"},{"key":"612_CR5","doi-asserted-by":"publisher","DOI":"10.5402\/2012\/509750","author":"CH Yeo","year":"2012","unstructured":"Yeo CH, Jariwala A, Pourgiezis N, Pillai A (2012) Assessing the accuracy of bone resection by cutting blocks in patient-specific total knee replacements. ISRN Orthop. \nhttps:\/\/doi.org\/10.5402\/2012\/509750","journal-title":"ISRN Orthop"},{"key":"612_CR6","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1007\/s11999-011-1996-6","volume":"470","author":"VY Ng","year":"2012","unstructured":"Ng VY, Declaire JH, Berend KR, Gulick BCRT, Lombardi AV Jr (2012) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470:99\u2013107","journal-title":"Clin Orthop Relat Res"},{"key":"612_CR7","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1055\/s-0032-1319785","volume":"25","author":"D Nam","year":"2012","unstructured":"Nam D, Mcarthur MDBA, Mayman DJ, Haas MDSB, Cross MB, Pearle AD (2012) Patient-specific instrumentation in total knee arthroplasty: a review. J Knee Surg 25:213\u2013219","journal-title":"J Knee Surg"},{"issue":"11","key":"612_CR8","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1302\/0301-620X.94B11.30834","volume":"94","author":"RL Barrack","year":"2012","unstructured":"Barrack RL, Ford AD, Foreman K, Nunley RM (2012) Patient specific cutting blocks are currently of no proven value. J Bone Joint Surg 94(11):95\u201399","journal-title":"J Bone Joint Surg"},{"issue":"3","key":"612_CR9","doi-asserted-by":"publisher","first-page":"354","DOI":"10.1302\/0301-620x.95b3.29903","volume":"95-B","author":"K Chareancholvanich","year":"2013","unstructured":"Chareancholvanich K, Narkbunnam R (2013) A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement. Bone Joint J 95-B(3):354\u2013359. \nhttps:\/\/doi.org\/10.1302\/0301-620x.95b3.29903","journal-title":"Bone Joint J"},{"issue":"3","key":"612_CR10","doi-asserted-by":"publisher","first-page":"523","DOI":"10.3233\/thc-171167-&gt","volume":"26","author":"A Klasan","year":"2018","unstructured":"Klasan A, Dworschak P, Heyse TJ, Lahner M, Malcherczyk D, Efe T, El-Zayat BF (2018) Patient-specific instruments\u2019 routine use over conventional total knee arthroplasty remains inconclusive: analysis of 961 cases. Technol Health Care 26(3):523\u2013528. \nhttps:\/\/doi.org\/10.3233\/thc-171167-&gt","journal-title":"Technol Health Care"},{"issue":"3","key":"612_CR11","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1016\/j.arth.2012.07.012","volume":"28","author":"S Lustig","year":"2013","unstructured":"Lustig S, Scholes CJ, Oussedik SI, Kinzel V, Coolican MRJ, Parker DA (2013) Unsatisfactory accuracy as determined by computer navigation of VISIONAIRE patient-specific instrumentation for total knee arthroplasty. J Arthroplasty [Internet] 28(3):469\u2013473. \nhttps:\/\/doi.org\/10.1016\/j.arth.2012.07.012","journal-title":"J Arthroplasty [Internet]"},{"key":"612_CR12","first-page":"6168","volume":"2","author":"M Calbiyik","year":"2017","unstructured":"Calbiyik M (2017) Clinical outcome of total knee arthroplasty performed using patient-specific cutting guides. Med Sci Monit Int Med J Exp Clin Res 2:6168\u20136173","journal-title":"Med Sci Monit Int Med J Exp Clin Res"},{"issue":"29","key":"612_CR13","first-page":"5","volume":"4","author":"I Nizam","year":"2018","unstructured":"Nizam I, Batra AV (2018) Accuracy of bone resection in total knee arthroplasty using CT assisted-3D printed patient speci fi c cutting guides. SICOT-J 4(29):5","journal-title":"SICOT-J"},{"key":"612_CR14","doi-asserted-by":"crossref","unstructured":"Stolarczyk A, Nagraba L, Mitek T, Stolarczyk M, Jakucinski M (2018) Does patient-specific instrumentation improve femoral and tibial component alignment in total knee arthroplasty? A prospective randomized study","DOI":"10.1007\/5584_2018_193"},{"key":"612_CR15","doi-asserted-by":"publisher","first-page":"2055","DOI":"10.1007\/s00167-014-2952-2","volume":"23","author":"E Thienpont","year":"2015","unstructured":"Thienpont E, Grosu I, Schwab FPP (2015) The use of patient-specific instruments does not reduce blood loss during minimally invasive total knee arthroplasty? Knee Surg Sports Traumatol Arthrosc 23:2055\u20132060","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"612_CR16","doi-asserted-by":"publisher","first-page":"1709","DOI":"10.1016\/j.arth.2014.01.039","volume":"29","author":"PB Voleti","year":"2014","unstructured":"Voleti PB, Hamula MJ, Baldwin KD et al (2014) Current data do not support routine use of patient-specific instrumentation in total knee arthroplasty. J Arthroplasty 29:1709\u20131712","journal-title":"J Arthroplasty"},{"issue":"1","key":"612_CR17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3758\/BF03203630","volume":"28","author":"E Erdfelder","year":"1996","unstructured":"Erdfelder E, Faul F, Buchner A (1996) GPOWER: A general power analysis program. Behav Res Methods Instrum Comput 28(1):1\u201311","journal-title":"Behav Res Methods Instrum Comput"},{"key":"612_CR18","first-page":"243","volume":"28","author":"G Dell\u2019Osso","year":"2016","unstructured":"Dell\u2019Osso G et al (2016) Single-use instrumentation technologies in knee arthroplasty: state of the art. Orthopaedic Surgery surgical technology international XXVIII. Surg Technol Int 28:243\u2013246","journal-title":"Surg Technol Int"},{"issue":"7","key":"612_CR19","doi-asserted-by":"publisher","first-page":"126","DOI":"10.21037\/atm.2016.03.33","volume":"4","author":"L Mattei","year":"2016","unstructured":"Mattei L et al (2016) Patient specific instrumentation in total knee arthroplasty: a state of the art. Cto hospital, citt\u00e0 della salute e della scienza, turin, Italy. Ann Transl Med 4(7):126","journal-title":"Ann Transl Med"},{"issue":"1","key":"612_CR20","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1007\/s11999-014-3804-6","volume":"473","author":"A Sassoon","year":"2015","unstructured":"Sassoon A, Nam D, Nunley R et al (2015) Systematic review of patient-specific instrumentation in total knee arthroplasty: new but not improved. Clin Orthop Relat Res 473(1):151\u2013158","journal-title":"Clin Orthop Relat Res"},{"issue":"6","key":"612_CR21","doi-asserted-by":"publisher","first-page":"446","DOI":"10.5312\/wjo.v6.i6.446","volume":"6","author":"P Sadoghi","year":"2015","unstructured":"Sadoghi P (2015) Current concepts in total knee arthroplasty: patient specific instrumentation Department of Orthopedic Surgery, Medical University of Graz, 8036 Graz. Austria. World J Orthop 6(6):446\u2013448","journal-title":"Austria. World J Orthop"},{"issue":"12","key":"612_CR22","doi-asserted-by":"publisher","first-page":"2271","DOI":"10.1016\/j.arth.2015.05.037","volume":"30","author":"Siegel Gw","year":"2015","unstructured":"Gw Siegel et al (2015) Cost analysis and surgical site infection rates in total knee arthroplasty comparing traditional vs. single-use instrumentation. J Arthroplasty 30(12):2271\u20132274. \nhttps:\/\/doi.org\/10.1016\/j.arth.2015.05.037","journal-title":"J Arthroplasty"},{"issue":"4","key":"612_CR23","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1055\/s-0033-1333664","volume":"26","author":"MA Mont","year":"2013","unstructured":"Mont MA, Johnson AJ, Issa K et al (2013) Single-use instrumentation, cutting blocks, and trials decrease contamination during total knee arthroplasty: a prospective comparison of navigated and non-navigated cases. J Knee Surg 26(4):285\u2013290","journal-title":"J Knee Surg"},{"issue":"6","key":"612_CR24","doi-asserted-by":"publisher","first-page":"1216","DOI":"10.1016\/j.knee.2014.09.008","volume":"21","author":"L Renson","year":"2014","unstructured":"Renson L, Poilvache P, Van den Wyngaert H (2014) Improved alignment and operating room efficiency with patient-specific instrumentation for TKA. Knee. 21(6):1216\u20131220","journal-title":"Knee."},{"issue":"5","key":"612_CR25","doi-asserted-by":"publisher","first-page":"e17","DOI":"10.1016\/j.ocl.2012.07.004","volume":"43","author":"MP Ast","year":"2012","unstructured":"Ast MP, Nam D (2012) Instrumentation for total knee arthroplasty: a review. Orthop Clin NA [Internet]. 43(5):e17\u2013e22. \nhttps:\/\/doi.org\/10.1016\/j.ocl.2012.07.004","journal-title":"Orthop Clin NA [Internet]."},{"key":"612_CR26","unstructured":"Conteduca F, Iorio R, Mazza D, Caperna L, Bolle G, Argento G et al Evaluation of the accuracy of a patient-specific instrumentation by navigation"},{"key":"612_CR27","doi-asserted-by":"publisher","first-page":"1705","DOI":"10.1016\/j.arth.2014.04.025","volume":"29","author":"BM Stronach","year":"2014","unstructured":"Stronach BM, Pelt CE, Erickson JA et al (2014) Patient-specific instrumentation in total knee arthroplasty provides no improvement in component alignment. J Arthroplasty 29:1705\u20131708","journal-title":"J Arthroplasty"},{"issue":"11","key":"612_CR28","doi-asserted-by":"publisher","first-page":"1601","DOI":"10.1007\/s00402-018-3031-9","volume":"138","author":"GG Jones","year":"2018","unstructured":"Jones GG, Clarke KLS, Collins R, Jaere RCM, Harris S, Cobb SHJP (2018) Do\u00a0patient-specific\u00a0instruments\u00a0(PSI) for UKA allow non-expert surgeons to achieve the same saw cut accuracy as expert surgeons? Arch Orthop Trauma Surg 138(11):1601\u20131608","journal-title":"Arch Orthop Trauma Surg"}],"container-title":["MUSCULOSKELETAL SURGERY"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12306-019-00612-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s12306-019-00612-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12306-019-00612-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,7,13]],"date-time":"2020-07-13T14:16:23Z","timestamp":1594649783000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s12306-019-00612-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5,30]]},"references-count":28,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,8]]}},"alternative-id":["612"],"URL":"https:\/\/doi.org\/10.1007\/s12306-019-00612-3","relation":{},"ISSN":["2035-5106","2035-5114"],"issn-type":[{"value":"2035-5106","type":"print"},{"value":"2035-5114","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,5,30]]},"assertion":[{"value":"25 July 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 May 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 May 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}