{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,3]],"date-time":"2026-02-03T19:23:41Z","timestamp":1770146621499,"version":"3.49.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2021,5,29]],"date-time":"2021-05-29T00:00:00Z","timestamp":1622246400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,5,29]],"date-time":"2021-05-29T00:00:00Z","timestamp":1622246400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Alma Mater Studiorum - Universit\u00e0 di Bologna"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Musculoskelet Surg"],"published-print":{"date-parts":[[2021,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Pedicle screws are the gold standard in spine surgery, allowing a solid tricolumnar fixation which is unmatched by hooks and wires. The freehand technique is the most widely adopted for pedicle screws placing. While freehand technique has been classically performed with manual tools, there has been a recent trend toward the use of power tools. The aim of this review is to summarize and expose potential risks and advantages of power pedicle screws placing. The literature showed that the use of power tools offers an acceptable safety profile, comparable to manual technique. With an adequate training, the power technique may speed up the screw placing, reduce the fluoroscopy time and the physical stress to the spine surgeon. Regarding differences in pull-out strength between power and manual techniques, the literature is still uncertain and inconsistent, both in clinical and preclinical studies. The choice between the use of power and manual freehand pedicle screws placing is still based on the surgeon\u2019s own preference.<\/jats:p>","DOI":"10.1007\/s12306-021-00714-x","type":"journal-article","created":{"date-parts":[[2021,5,29]],"date-time":"2021-05-29T03:41:07Z","timestamp":1622259667000},"page":"117-123","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Power-assisted pedicle screws placement: Is it as safe and as effective as manual technique? Narrative review of the literature and our technique"],"prefix":"10.1007","volume":"105","author":[{"given":"C.","family":"Faldini","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4348-0983","authenticated-orcid":false,"given":"G.","family":"Viroli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Fiore","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F.","family":"Barile","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Manzetti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Di Martino","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Ruffilli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,5,29]]},"reference":[{"key":"714_CR1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620x.41b2.248","author":"HH Boucher","year":"1959","unstructured":"Boucher HH (1959) A method of spinal fusion. J Bone Joint Surg Br. https:\/\/doi.org\/10.1302\/0301-620x.41b2.248","journal-title":"J Bone Joint Surg Br"},{"key":"714_CR2","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/S0030-5898(20)30425-9","volume":"17","author":"R Roy-Camille","year":"1986","unstructured":"Roy-Camille R, Saillant G, Mazel C (1986) Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates. Orthop Clin North Am 17:147\u2013159","journal-title":"Orthop Clin North Am"},{"key":"714_CR3","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-198602000-00003","author":"R Roy-Camille","year":"1986","unstructured":"Roy-Camille R, Saillant G, Mazel C (1986) Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res. https:\/\/doi.org\/10.1097\/00003086-198602000-00003","journal-title":"Clin Orthop Relat Res"},{"key":"714_CR4","doi-asserted-by":"publisher","first-page":"104","DOI":"10.3171\/spi.2003.99.1.0104","volume":"99","author":"PW Hitchon","year":"2003","unstructured":"Hitchon PW, Brenton MD, Black AG, From A, Harrod JS, Barry C, Serhan H, Torner JC (2003) In vitro biomechanical comparison of pedicle screws, sublaminar hooks, and sublaminar cables. J Neurosurg 99:104\u2013109. https:\/\/doi.org\/10.3171\/spi.2003.99.1.0104","journal-title":"J Neurosurg"},{"key":"714_CR5","doi-asserted-by":"publisher","first-page":"1702","DOI":"10.1016\/j.spinee.2014.03.044","volume":"14","author":"E Koktekir","year":"2014","unstructured":"Koktekir E, Ceylan D, Tatarli N, Karabagli H, Recber F, Akdemir G (2014) Accuracy of fluoroscopically-assisted pedicle screw placement: analysis of 1,218 screws in 198 patients. Spine J 14:1702\u20131708. https:\/\/doi.org\/10.1016\/j.spinee.2014.03.044","journal-title":"Spine J"},{"key":"714_CR6","doi-asserted-by":"publisher","first-page":"e87","DOI":"10.1016\/j.wneu.2020.07.205","volume":"144","author":"J Sun","year":"2020","unstructured":"Sun J, Wu D, Wang Q, Wei Y, Yuan F (2020) Pedicle screw insertion: is O-arm-based navigation superior to the conventional freehand technique? A systematic review and meta-analysis. World Neurosurg 144:e87\u2013e99. https:\/\/doi.org\/10.1016\/j.wneu.2020.07.205","journal-title":"World Neurosurg"},{"key":"714_CR7","doi-asserted-by":"publisher","DOI":"10.1177\/2192568220956979","author":"BD Crawford","year":"2020","unstructured":"Crawford BD, Nchako CM, Rebehn KA, Israel H, Place HM (2020) Transpedicular screw placement accuracy using the O-arm versus freehand technique at a single institution. Glob Spine J. https:\/\/doi.org\/10.1177\/2192568220956979","journal-title":"Glob Spine J"},{"key":"714_CR8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.2106\/JBJS.ST.19.00020","volume":"10","author":"IH Lieberman","year":"2020","unstructured":"Lieberman IH, Kisinde S, Hesselbacher S (2020) Robotic-assisted pedicle screw placement during spine surgery. JBJS Essent Surg Tech 10:1\u201315. https:\/\/doi.org\/10.2106\/JBJS.ST.19.00020","journal-title":"JBJS Essent Surg Tech"},{"key":"714_CR9","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0000000000003193","author":"HM Li","year":"2020","unstructured":"Li HM, Zhang RJ, Shen CL (2020) Accuracy of pedicle screw placement and clinical outcomes of robot-assisted technique versus conventional freehand technique in spine surgery from nine randomized controlled trials: a meta-analysis. Spine (Phila PA 1976). https:\/\/doi.org\/10.1097\/BRS.0000000000003193","journal-title":"Spine (Phila PA 1976)"},{"key":"714_CR10","doi-asserted-by":"publisher","first-page":"1715","DOI":"10.1097\/BRS.0b013e31821cd140","volume":"36","author":"JD Auerbach","year":"2011","unstructured":"Auerbach JD, Weidner ZD, Milby AH, Diab M, Lonner BS (2011) Musculoskeletal disorders among spine surgeons: results of a survey of the scoliosis research society membership. Spine (Phila PA 1976) 36:1715\u20131721. https:\/\/doi.org\/10.1097\/BRS.0b013e31821cd140","journal-title":"Spine (Phila PA 1976)"},{"key":"714_CR11","doi-asserted-by":"publisher","first-page":"1337","DOI":"10.1016\/j.wneu.2014.07.041","volume":"82","author":"D Srinivasan","year":"2014","unstructured":"Srinivasan D, Than KD, Wang AC, La Marca F, Wang PI, Schermerhorn TC, Park P (2014) Radiation safety and spine surgery: systematic review of exposure limits and methods to minimize radiation exposure. World Neurosurg 82:1337\u20131343. https:\/\/doi.org\/10.1016\/j.wneu.2014.07.041","journal-title":"World Neurosurg"},{"key":"714_CR12","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-200006150-00013","author":"YR Rampersaud","year":"2000","unstructured":"Rampersaud YR, Foley KT, Shen AC, Williams S, Solomito M (2000) Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine. https:\/\/doi.org\/10.1097\/00007632-200006150-00013","journal-title":"Spine"},{"key":"714_CR13","doi-asserted-by":"publisher","first-page":"268","DOI":"10.5435\/JAAOS-D-16-00342","volume":"26","author":"RA Hayda","year":"2018","unstructured":"Hayda RA, Hsu RY, Mason DePasse J, Gil JA (2018) Radiation exposure and health risks for orthopaedic surgeons. J Am Acad Orthop Surg 26:268\u2013277. https:\/\/doi.org\/10.5435\/JAAOS-D-16-00342","journal-title":"J Am Acad Orthop Surg"},{"key":"714_CR14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-019-53472-z","volume":"9","author":"G Bratschitsch","year":"2019","unstructured":"Bratschitsch G, Leitner L, St\u00fccklschweiger G, Guss H, Sadoghi P, Puchwein P, Leithner A, Radl R (2019) Radiation exposure of patient and operating room personnel by fluoroscopy and navigation during spinal surgery. Sci Rep 9:1\u20135. https:\/\/doi.org\/10.1038\/s41598-019-53472-z","journal-title":"Sci Rep"},{"key":"714_CR15","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199116020-00015","author":"DC George","year":"1991","unstructured":"George DC, Krag MH, Johnson CC, Van Hal ME, Haugh LD, Grobler LJ (1991) Hole preparation techniques for transpedicle screws: Effect on pull-out strength from human cadaveric vertebrae. Spine (Phila PA 1976). https:\/\/doi.org\/10.1097\/00007632-199116020-00015","journal-title":"Spine (Phila PA 1976)"},{"key":"714_CR16","doi-asserted-by":"publisher","DOI":"10.1590\/S1413-78522012000500006","author":"GS Abrah\u00e3o","year":"2012","unstructured":"Abrah\u00e3o GS, Rosa RC, Okubo R, Shimano AC (2012) Effect of the pilot hole preparation on the anchorage of pedicle screws. Acta Ortop Bras. https:\/\/doi.org\/10.1590\/S1413-78522012000500006","journal-title":"Acta Ortop Bras"},{"key":"714_CR17","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2020.104997","author":"S Oikonomidis","year":"2020","unstructured":"Oikonomidis S, Grevenstein D, Yagdiran A, Scheyerer MJ, Eh M, Wegmann K, Eysel P, Sircar K (2020) Probe versus drill: a biomechanical evaluation of two different pedicle preparation techniques for pedicle screw fixation in human cadaveric osteoporotic spine. Clin Biomech. https:\/\/doi.org\/10.1016\/j.clinbiomech.2020.104997","journal-title":"Clin Biomech"},{"key":"714_CR18","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/j.jspd.2014.07.001","volume":"3","author":"DA Seehausen","year":"2015","unstructured":"Seehausen DA, Skaggs DL, Andras LM, Javidan Y (2015) Safety and efficacy of power-assisted pedicle tract preparation and screw placement. Spine Deform 3:159\u2013165. https:\/\/doi.org\/10.1016\/j.jspd.2014.07.001","journal-title":"Spine Deform"},{"key":"714_CR19","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1007\/s12306-016-0438-8","volume":"100","author":"F Perna","year":"2016","unstructured":"Perna F, Borghi R, Pilla F, Stefanini N, Mazzotti A, Chehrassan M (2016) Pedicle screw insertion techniques: an update and review of the literature. Musculoskelet Surg 100:165\u2013169. https:\/\/doi.org\/10.1007\/s12306-016-0438-8","journal-title":"Musculoskelet Surg"},{"key":"714_CR20","doi-asserted-by":"publisher","first-page":"23","DOI":"10.14444\/2023","volume":"9","author":"J Allen","year":"2015","unstructured":"Allen J, Akpolat YT, Kishan S, Peppers T, Asgarzadie F, Cheng WK (2015) Comparison between gearshift and drill techniques for pedicle screw placement by resident surgeons. Int J Spine Surg. 9:23","journal-title":"Int J Spine Surg."},{"key":"714_CR21","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2020.05.413","author":"DL Skaggs","year":"2020","unstructured":"Skaggs DL, Claeson A, Schwab FJ, Gandhi A (2020) P15: Power-assisted pedicle screw placement decreases screw wobble. Spine J. https:\/\/doi.org\/10.1016\/j.spinee.2020.05.413","journal-title":"Spine J"},{"key":"714_CR22","unstructured":"Mahajan A, Vadapalli S, Steele B (2012) Biomechanical evaluation of the POWEREASE tapper\/driver system. Medtronic Intern White Pap 1\u20134"},{"key":"714_CR23","doi-asserted-by":"publisher","first-page":"e79","DOI":"10.1016\/j.wneu.2018.04.047","volume":"116","author":"H Yan","year":"2018","unstructured":"Yan H, Jiang D, Xu L, Liu Z, Sun X, Sha S, Qiu Y, Zhu Z (2018) Does the full power-assisted technique used in pedical screw placement affect the safety and efficacy of adolescent idiopathic scoliosis surgery? World Neurosurg 116:e79\u2013e85. https:\/\/doi.org\/10.1016\/j.wneu.2018.04.047","journal-title":"World Neurosurg"},{"key":"714_CR24","doi-asserted-by":"publisher","first-page":"60","DOI":"10.22603\/ssrr.2017-0029","volume":"2","author":"A Kojima","year":"2018","unstructured":"Kojima A, Fujii A, Morioka S, Torii Y, Arai K, Sasao Y (2018) Safety and efficacy of percutaneous pedicle screw placement using a power tool. Spine Surg Relat Res 2:60\u201364","journal-title":"Spine Surg Relat Res"},{"key":"714_CR25","unstructured":"Skaggs DL, Schwab F, Cleason AGA (2019) Power-assisted pedicle screw insertion reduces muscle exertion. In: Congress of neurological surgeons annual meeting"},{"key":"714_CR26","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1007\/s00586-018-5595-z","volume":"27","author":"C Faldini","year":"2018","unstructured":"Faldini C, Perna F, Geraci G, Pardo F, Mazzotti A, Pilla F, Ruffilli A (2018) Triplanar correction of adolescent idiopathic scoliosis by asymmetrically shaped and simultaneously applied rods associated with direct vertebral rotation: clinical and radiological analysis of 36 patients. Eur Spine J 27:165\u2013174. https:\/\/doi.org\/10.1007\/s00586-018-5595-z","journal-title":"Eur Spine J"},{"key":"714_CR27","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1007\/s00586-018-05865-3","volume":"28","author":"C Faldini","year":"2019","unstructured":"Faldini C, Perna F, Ruffilli A, Mazzotti A, Panciera A, Traina F (2019) Surgical correction in AIS. Eur Spine J 28:6\u20138. https:\/\/doi.org\/10.1007\/s00586-018-05865-3","journal-title":"Eur Spine J"},{"key":"714_CR28","doi-asserted-by":"publisher","DOI":"10.1007\/s43390-021-00343-1","author":"A Ruffilli","year":"2021","unstructured":"Ruffilli A, Fiore M, Martikos K, Barile F, Pasini S, Battaglia M, Greggi T, Faldini C (2021) Does use of pre-operative low-dose CT-scan in adolescent idiopathic scoliosis improve accuracy in screw placement? Results of a retrospective study. Spine Deformity. https:\/\/doi.org\/10.1007\/s43390-021-00343-1","journal-title":"Spine Deformity"},{"key":"714_CR29","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1227\/NEU.0b013e3181fdfaf4","volume":"68","author":"SL Parker","year":"2011","unstructured":"Parker SL, McGirt MJ, Farber SH, Amin AG, Rick AM, Suk I, Bydon A, Sciubba DM, Wolinsky JP, Gokaslan ZL, Witham TF (2011) Accuracy of free-hand pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws. Neurosurgery 68:170\u2013178. https:\/\/doi.org\/10.1227\/NEU.0b013e3181fdfaf4","journal-title":"Neurosurgery"},{"key":"714_CR30","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1007\/s00264-007-0363-4","volume":"32","author":"KJ Chung","year":"2008","unstructured":"Chung KJ, Suh SW, Desai S, Song HR (2008) Ideal entry point for the thoracic pedicle screw during the free hand technique. Int Orthop 32:657\u2013662. https:\/\/doi.org\/10.1007\/s00264-007-0363-4","journal-title":"Int Orthop"},{"key":"714_CR31","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1097\/MD.0000000000009907","volume":"97","author":"TH Kim","year":"2018","unstructured":"Kim TH, Lee SH, Yang JH, Hong JY, Suh SW (2018) Clinical significance of superior articular process as a reference point for free-hand pedicle screw insertion in thoracic spine. Med (United States) 97:1\u20137. https:\/\/doi.org\/10.1097\/MD.0000000000009907","journal-title":"Med (United States)"},{"issue":"1","key":"714_CR32","first-page":"1","volume":"1","author":"KD Illingworth","year":"2019","unstructured":"Illingworth KD, Andras LM, Claeson AA, Skaggs DL (2019) Surgical technique: power pedicle preparation and screw insertion in the treatment of pediatric spinal deformity. JPONSA 1(1):1\u20138","journal-title":"JPONSA"},{"key":"714_CR33","doi-asserted-by":"publisher","first-page":"1836","DOI":"10.1097\/brs.0b013e3181d3cfde","volume":"35","author":"K Watanabe","year":"2010","unstructured":"Watanabe K, Lenke LG, Matsumoto M, Harimaya K, Kim YJ, Hensley M, Stobbs G, Toyama Y, Chiba K (2010) A novel pedicle channel classification describing osseous anatomy. Spine (Phila PA 1976) 35:1836\u20131842. https:\/\/doi.org\/10.1097\/brs.0b013e3181d3cfde","journal-title":"Spine (Phila PA 1976)"},{"key":"714_CR34","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1097\/00002517-199806000-00007","volume":"11","author":"JW Barber","year":"1998","unstructured":"Barber JW, Boden SD, Ganey T, Hutton WC (1998) Biomechanical study of lumbar pedicle screws: does convergence affect axial pullout strength? J Spinal Disord 11:215\u2013220","journal-title":"J Spinal Disord"},{"key":"714_CR35","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-009-1063-0","author":"S Erkan","year":"2010","unstructured":"Erkan S, Hsu B, Wu C, Mehbod AA, Perl J, Transfeldt EE (2010) Alignment of pedicle screws with pilot holes: can tapping improve screw trajectory in thoracic spines? Eur Spine J. https:\/\/doi.org\/10.1007\/s00586-009-1063-0","journal-title":"Eur Spine J"}],"container-title":["MUSCULOSKELETAL SURGERY"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12306-021-00714-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12306-021-00714-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12306-021-00714-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,30]],"date-time":"2021-07-30T14:45:45Z","timestamp":1627656345000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12306-021-00714-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,29]]},"references-count":35,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,8]]}},"alternative-id":["714"],"URL":"https:\/\/doi.org\/10.1007\/s12306-021-00714-x","relation":{},"ISSN":["2035-5106","2035-5114"],"issn-type":[{"value":"2035-5106","type":"print"},{"value":"2035-5114","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,5,29]]},"assertion":[{"value":"28 April 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 May 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 May 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}