{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T14:56:27Z","timestamp":1740149787558,"version":"3.37.3"},"reference-count":11,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,9,21]],"date-time":"2020-09-21T00:00:00Z","timestamp":1600646400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,9,21]],"date-time":"2020-09-21T00:00:00Z","timestamp":1600646400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Clin J Gastroenterol"],"published-print":{"date-parts":[[2021,2]]},"DOI":"10.1007\/s12328-020-01235-z","type":"journal-article","created":{"date-parts":[[2020,9,21]],"date-time":"2020-09-21T10:03:00Z","timestamp":1600682580000},"page":"141-145","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Detection of inadequate anastomotic perfusion with handheld vital microscopy in two patients during colorectal surgery"],"prefix":"10.1007","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0505-4492","authenticated-orcid":false,"given":"Arthur L. M.","family":"Tavy","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anton F. J.","family":"de Bruin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mat","family":"van Iterson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anke B.","family":"Smits","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E. Christaan","family":"Boerma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Can","family":"Ince","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter G.","family":"Noordzij","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Djamila","family":"Boerma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,9,21]]},"reference":[{"key":"1235_CR1","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1016\/j.ejso.2009.08.011","volume":"36","author":"R Kube","year":"2010","unstructured":"Kube R, Mroczkowski P, Granowski D, et al. Anastomotic leakage after colon cancer surgery: a predictor of significant morbidity and hospital mortality, and diminished tumour-free survival. Eur J Surg Oncol. 2010;36:120\u20134.","journal-title":"Eur J Surg Oncol"},{"doi-asserted-by":"crossref","unstructured":"Karliczek A, Harlaar NJ, Zeebregts CJ, et al (2009) Surgeons lack predictive accuracy for anastomotic leakage in gastrointestinal surgery. Int J Colorectal Dis 24:569\u2013576","key":"1235_CR2","DOI":"10.1007\/s00384-009-0658-6"},{"key":"1235_CR3","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1111\/codi.13250","volume":"18","author":"AFJ de Bruin","year":"2016","unstructured":"de Bruin AFJ, Kornmann VNN, van der Sloot K, et al. Sidestream dark field imaging of the serosal microcirculation during gastrointestinal surgery. Color Dis. 2016;18:103\u201310.","journal-title":"Color Dis"},{"key":"1235_CR4","doi-asserted-by":"publisher","first-page":"3911","DOI":"10.1007\/s00268-018-4746-z","volume":"42","author":"ALM Tavy","year":"2018","unstructured":"Tavy ALM, De BAFJ, Van Der SK, et al. Effects of thoracic epidural anaesthesia on the serosal microcirculation of the human small intestine. World J Surg. 2018;42:3911\u20137.","journal-title":"World J Surg"},{"key":"1235_CR5","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1159\/000448735","volume":"53","author":"AFJ De Bruin","year":"2016","unstructured":"De Bruin AFJ, Tavy A, Van Der Sloot K, et al. Use of an image acquisition stabilizer improves sidestream dark field imaging of the serosa during open gastrointestinal surgery. J Vasc Res. 2016;53:121\u20137.","journal-title":"J Vasc Res"},{"key":"1235_CR6","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1007\/s00134-018-5070-7","volume":"44","author":"C Ince","year":"2018","unstructured":"Ince C, Boerma EC, Cecconi M, et al. Second consensus on the assessment of sublingual microcirculation in critically ill patients: results from a task force of the European Society of Intensive Care Medicine. Intensive Care Med. 2018;44:281\u201399.","journal-title":"Intensive Care Med"},{"key":"1235_CR7","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1007\/s10151-017-1731-8","volume":"22","author":"RB Colino","year":"2018","unstructured":"Colino RB, Basany EE. Intraoperative use of ICG fluorescence imaging to reduce the risk of anastomotic leakage in colorectal surgery: a systematic review and meta-analysis. Tech Coloproctol. 2018;22:15\u201323.","journal-title":"Tech Coloproctol"},{"key":"1235_CR8","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1007\/s10151-018-1872-4","volume":"22","author":"AFJ de Bruin","year":"2018","unstructured":"de Bruin AFJ, Tavy ALM, van der Sloot K, et al. Can sidestream dark field (SDF) imaging identify subtle microvascular changes of the bowel during colorectal surgery ? Tech Coloproctol. 2018;22:793\u2013800.","journal-title":"Tech Coloproctol"},{"key":"1235_CR9","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1159\/000505325","volume":"60","author":"ALM Tavy","year":"2019","unstructured":"Tavy ALM, de Bruin AFJ, Smits AB, et al. Intestinal mucosal and serosal microcirculation at the planned anastomosis during abdominal surgery. Eur Surg Res. 2019;60:248\u201356.","journal-title":"Eur Surg Res"},{"key":"1235_CR10","first-page":"698","volume":"77","author":"EC Boerma","year":"2011","unstructured":"Boerma EC, Kaiferov\u00e1 K, Konijn AJM, et al. Rectal microcirculatory alterations after elective on-pump cardiac surgery. Minerva Anestesiol. 2011;77:698\u2013703.","journal-title":"Minerva Anestesiol"},{"key":"1235_CR11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s42003-019-0473-8","volume":"2","author":"MP Hilty","year":"2019","unstructured":"Hilty MP, Guerci P, Ince Y, et al. MicroTools enables automated quantification of capillary density and red blood cell velocity in handheld vital microscopy. Commun Biol. 2019;2:1\u201315.","journal-title":"Commun Biol"}],"container-title":["Clinical Journal of Gastroenterology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12328-020-01235-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12328-020-01235-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12328-020-01235-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,21]],"date-time":"2021-09-21T00:33:32Z","timestamp":1632184412000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12328-020-01235-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,21]]},"references-count":11,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,2]]}},"alternative-id":["1235"],"URL":"https:\/\/doi.org\/10.1007\/s12328-020-01235-z","relation":{},"ISSN":["1865-7257","1865-7265"],"issn-type":[{"type":"print","value":"1865-7257"},{"type":"electronic","value":"1865-7265"}],"subject":[],"published":{"date-parts":[[2020,9,21]]},"assertion":[{"value":"23 June 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 September 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 September 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"C.I. and his team developed SDF imaging and AVA software for analysis of microcirculation images used in this paper. These products are commercialized by MicroVision Medical (MVM) under a license from the Amsterdam University Medical Center. Braedius Medical, a company owned by a relative of C.I., has developed and designed a handheld microscope called CytoCam-IDF imaging used in this study. C.I. has no financial relationship with Braedius Medical of any sort, that is, never owned shares, or received consultancy or speaker fees from Braedius Medical. Active Medical BV, of which C.I. is a shareholder, runs an internet site called microcirculationacademy.org which offers educational courses and services related to clinical microcirculation. MicroTools software automatic analysis of microcirculation images is being developed with support from Active Medical BV. The other authors have no conflict of interest to declare.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study complied with ethical requirements and was approved by the medical ethical committee. Informed consent was obtained from all individual participants. Trial registry number: ClinicalTrials.gov identifier NCT02688946.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"All study participants gave written informed consent to participate in the study, as described in the methods section.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}