{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T14:57:43Z","timestamp":1740149863330,"version":"3.37.3"},"reference-count":10,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,11,12]],"date-time":"2024-11-12T00:00:00Z","timestamp":1731369600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,11,12]],"date-time":"2024-11-12T00:00:00Z","timestamp":1731369600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100004721","name":"The University of Tokyo","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100004721","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Clin J Gastroenterol"],"published-print":{"date-parts":[[2025,2]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>This case report presents a common but instructive clinical scenario of accidental ingestion of a press-through package. Despite an initial negative chest X-ray and mild symptoms, the diagnosis was confirmed with additional computed tomography. The patient was eventually went through the successful endoscopic removal of the press-through package. Furthermore, a retrospective re-reviewing of the X-ray revealed a faint ring-shaped gas sign, characteristic of press-through package ingestion. This case underscores the intractableness to diagnosis of accidental ingestion of press-through package by only X-rays in real time and the potential role of computed tomography in ensuring timely diagnosis and treatment.<\/jats:p>","DOI":"10.1007\/s12328-024-02060-4","type":"journal-article","created":{"date-parts":[[2024,11,12]],"date-time":"2024-11-12T06:16:26Z","timestamp":1731392186000},"page":"53-56","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A ring-shaped gas sign: a case of the accidental ingestion of a press-through package"],"prefix":"10.1007","volume":"18","author":[{"given":"Dai","family":"Kubota","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9537-4993","authenticated-orcid":false,"given":"Yosuke","family":"Tsuji","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoku","family":"Hayakawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mitsuhiro","family":"Fujishiro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,11,12]]},"reference":[{"key":"2060_CR1","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1016\/j.gie.2010.11.010","volume":"73","author":"SO Ikenberry","year":"2011","unstructured":"Ikenberry SO, Jue TL, Anderson MA, et al. Management of ingested foreign bodies and food impactions. Gastrointest Endosc. 2011;73:1085\u201391.","journal-title":"Gastrointest Endosc"},{"key":"2060_CR2","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1186\/s13017-019-0245-2","volume":"14","author":"M Chirica","year":"2019","unstructured":"Chirica M, Kelly MD, Siboni S, et al. Esophageal emergencies: WSES guidelines. World J Emerg Surg. 2019;14:26.","journal-title":"World J Emerg Surg"},{"key":"2060_CR3","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1055\/s-0042-100456","volume":"48","author":"M Birk","year":"2016","unstructured":"Birk M, Bauerfeind P, Deprez PH, et al. Removal of foreign bodies in the upper gastrointestinal tract in adults: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline. Endoscopy. 2016;48:489\u201396.","journal-title":"Endoscopy"},{"key":"2060_CR4","doi-asserted-by":"publisher","first-page":"33","DOI":"10.4253\/wjge.v12.i1.33","volume":"12","author":"KJ Limpias Kamiya","year":"2020","unstructured":"Limpias Kamiya KJ, Hosoe N, Takabayashi K, et al. Endoscopic removal of foreign bodies: a retrospective study in Japan. World J Gastrointest Endosc. 2020;12:33\u201341.","journal-title":"World J Gastrointest Endosc"},{"key":"2060_CR5","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1111\/j.1742-1241.2006.00766.x","volume":"60","author":"S-K Hou","year":"2006","unstructured":"Hou S-K, Chern C-H, How C-K, et al. Press through package mis-swallowing. Int J Clin Pract. 2006;60:234\u20137.","journal-title":"Int J Clin Pract"},{"key":"2060_CR6","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1016\/j.annemergmed.2007.11.017","volume":"52","author":"K-I Lee","year":"2008","unstructured":"Lee K-I, Wang C-P. Throat pain. Ann Emerg Med. 2008;52:98\u2013115.","journal-title":"Ann Emerg Med"},{"key":"2060_CR7","doi-asserted-by":"publisher","first-page":"5909","DOI":"10.3748\/wjg.v12.i36.5909","volume":"12","author":"YS Seo","year":"2006","unstructured":"Seo YS, Park JJ, Kim JH, et al. Removal of press-through-packs impacted in the upper esophagus using an overtube. World J Gastroenterol. 2006;12:5909\u201312.","journal-title":"World J Gastroenterol"},{"key":"2060_CR8","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/j.ajem.2021.07.048","volume":"50","author":"X Wang","year":"2021","unstructured":"Wang X, Zhao J, Jiao Y, et al. Upper gastrointestinal foreign bodies in adults: a systematic review. Am J Emerg Med. 2021;50:136\u201341.","journal-title":"Am J Emerg Med"},{"key":"2060_CR9","doi-asserted-by":"publisher","first-page":"1467","DOI":"10.1111\/j.1532-5415.2006.00858.x","volume":"54","author":"JM Bosmans","year":"2006","unstructured":"Bosmans JM, Spinhoven MJ, Deckers FP, et al. Accidental ingestion of a press-through package: an underestimated cause of serious iatrogenic disease in the elderly? J Am Geriatr Soc. 2006;54:1467\u20138.","journal-title":"J Am Geriatr Soc"},{"key":"2060_CR10","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1002\/ams2.90","volume":"2","author":"A Kanazawa","year":"2015","unstructured":"Kanazawa A, Kamezaki F, Kido T, et al. Press-through package mis-swallowing: usefulness of computed tomography. Acute Med Surg. 2015;2:195\u20138.","journal-title":"Acute Med Surg"}],"container-title":["Clinical Journal of Gastroenterology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12328-024-02060-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12328-024-02060-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12328-024-02060-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,31]],"date-time":"2025-01-31T13:17:11Z","timestamp":1738329431000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12328-024-02060-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,12]]},"references-count":10,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025,2]]}},"alternative-id":["2060"],"URL":"https:\/\/doi.org\/10.1007\/s12328-024-02060-4","relation":{},"ISSN":["1865-7257","1865-7265"],"issn-type":[{"type":"print","value":"1865-7257"},{"type":"electronic","value":"1865-7265"}],"subject":[],"published":{"date-parts":[[2024,11,12]]},"assertion":[{"value":"21 July 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 November 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 November 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"DK and YT belong to Next-generation Endoscopic Computer Vision, which is an endowment department, supported with an unrestricted grant from AI Medical Service Inc. The other authors declare no conflict of interest for this article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The study was performed according to the 1964 Declaration of Helsinki including its later amendments.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human rights"}},{"value":"Informed consent was obtained from the patient to be included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}