{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T21:48:45Z","timestamp":1780523325069,"version":"3.54.1"},"reference-count":41,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2021,2,1]],"date-time":"2021-02-01T00:00:00Z","timestamp":1612137600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,2,1]],"date-time":"2021-02-01T00:00:00Z","timestamp":1612137600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["journals.elsevierhealth.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Nuclear Cardiology"],"published-print":{"date-parts":[[2021,2]]},"DOI":"10.1007\/s12350-018-01585-9","type":"journal-article","created":{"date-parts":[[2019,1,2]],"date-time":"2019-01-02T15:30:06Z","timestamp":1546443006000},"page":"187-195","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":12,"title":["Feasibility of simultaneous 99mTc-tetrofosmin and 123I-BMIPP dual-tracer imaging with cadmium-zinc-telluride detectors in patients undergoing primary coronary intervention for acute myocardial infarction"],"prefix":"10.1016","volume":"28","author":[{"given":"Yoshihiro","family":"Yamada","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shintaro","family":"Nakano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Youdou","family":"Gatate","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nanami","family":"Okano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshihiro","family":"Muramatsu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigeyuki","family":"Nishimura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ichiei","family":"Kuji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenji","family":"Fukushima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ichiro","family":"Matsunari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1007\/s12350-018-01585-9_bib1","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1016\/S0008-6363(96)00245-3","article-title":"Regulation of myocardial carbohydrate metabolism under normal and ischaemic conditions. Potential for pharmacological interventions","volume":"33","author":"Stanley","year":"1997","journal-title":"Cardiovasc Res"},{"key":"10.1007\/s12350-018-01585-9_bib2","doi-asserted-by":"crossref","first-page":"1671","DOI":"10.1161\/01.CIR.86.6.1671","article-title":"Myocardial \u2018stunning\u2019 in man","volume":"86","author":"Bolli","year":"1992","journal-title":"Circulation"},{"key":"10.1007\/s12350-018-01585-9_bib3","doi-asserted-by":"crossref","first-page":"2169","DOI":"10.1161\/CIRCULATIONAHA.104.530428","article-title":"Metabolic imaging with beta-methyl-p-[(123)I]-iodophenyl-pentadecanoic acid identifies ischemic memory after demand ischemia","volume":"112","author":"Dilsizian","year":"2005","journal-title":"Circulation"},{"key":"10.1007\/s12350-018-01585-9_bib4","doi-asserted-by":"crossref","first-page":"S118","DOI":"10.1016\/j.nuclcard.2007.02.007","article-title":"Imaging of myocardial fatty acid metabolism with PET","volume":"14","author":"Bergmann","year":"2007","journal-title":"J Nucl Cardiol"},{"key":"10.1007\/s12350-018-01585-9_bib5","first-page":"707","article-title":"Influence of methodology on the presence and extent of mismatching between 99 mTc-MIBI and 123I-BMIPP in myocardial viability studies","volume":"40","author":"Dobbeleir","year":"1999","journal-title":"J Nucl Med"},{"key":"10.1007\/s12350-018-01585-9_bib6","first-page":"1974","article-title":"Decreased uptake of iodinated branched fatty acid analog indicates metabolic alterations in ischemic myocardium","volume":"36","author":"Tamaki","year":"1995","journal-title":"J Nucl Med"},{"key":"10.1007\/s12350-018-01585-9_bib7","doi-asserted-by":"crossref","first-page":"1494","DOI":"10.1007\/s002590000332","article-title":"Prediction of functional outcome by quantification of sestamibi and BMIPP after acute myocardial infarction","volume":"27","author":"Hambye","year":"2000","journal-title":"Eur J Nucl Med"},{"key":"10.1007\/s12350-018-01585-9_bib8","first-page":"718","article-title":"Prediction of functional outcome after myocardial infarction using BMIPP and sestamibi scintigraphy","volume":"37","author":"Franken","year":"1996","journal-title":"J Nucl Med"},{"key":"10.1007\/s12350-018-01585-9_bib9","doi-asserted-by":"crossref","DOI":"10.1155\/2014\/942960","article-title":"New SPECT and PET radiopharmaceuticals for imaging cardiovascular disease","volume":"2014","author":"Sogbein","year":"2014","journal-title":"Biomed Res Int"},{"key":"10.1007\/s12350-018-01585-9_bib10","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1007\/s12149-015-1055-6","article-title":"Simultaneous acquisition of (99 m)Tc- and (123)I-labeled radiotracers using a preclinical SPECT scanner with CZT detectors","volume":"30","author":"Kobayashi","year":"2016","journal-title":"Ann Nucl Med"},{"key":"10.1007\/s12350-018-01585-9_bib11","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1007\/s00380-014-0578-4","article-title":"A preliminary feasibility study of simultaneous dual-isotope imaging with a solid-state dedicated cardiac camera for evaluating myocardial perfusion and fatty acid metabolism","volume":"31","author":"Ko","year":"2016","journal-title":"Heart Vessels"},{"key":"10.1007\/s12350-018-01585-9_bib12","doi-asserted-by":"crossref","first-page":"661","DOI":"10.2967\/jnumed.106.032680","article-title":"Recent advances in SPECT imaging","volume":"48","author":"Madsen","year":"2007","journal-title":"J Nucl Med"},{"key":"10.1007\/s12350-018-01585-9_bib13","doi-asserted-by":"crossref","first-page":"635","DOI":"10.2967\/jnumed.108.060020","article-title":"A novel high-sensitivity rapid-acquisition single-photon cardiac imaging camera","volume":"50","author":"Gambhir","year":"2009","journal-title":"J Nucl Med"},{"key":"10.1007\/s12350-018-01585-9_bib14","doi-asserted-by":"crossref","first-page":"1887","DOI":"10.1007\/s00259-010-1488-z","article-title":"A fast cardiac gamma camera with dynamic SPECT capabilities: Design, system validation and future potential","volume":"37","author":"Bocher","year":"2010","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"10.1007\/s12350-018-01585-9_bib15","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1093\/ehjci\/jet149","article-title":"Rapid-acquisition myocardial perfusion scintigraphy (MPS) on a novel gamma camera using multipinhole collimation and miniaturized cadmium-zinc-telluride (CZT) detectors: Prognostic value and diagnostic accuracy in a \u2018real-world\u2019 nuclear cardiology service","volume":"15","author":"Chowdhury","year":"2014","journal-title":"Eur Heart J Cardiovas Imaging"},{"key":"10.1007\/s12350-018-01585-9_bib16","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1016\/S1071-3581(99)90014-4","article-title":"American Society of Nuclear Cardiology position statement on electrocardiographic gating of myocardial perfusion SPECT scintigrams","volume":"6","author":"Bateman","year":"1999","journal-title":"J Nucl Cardiol"},{"key":"10.1007\/s12350-018-01585-9_bib17","doi-asserted-by":"crossref","first-page":"46","DOI":"10.2967\/jnumed.109.065532","article-title":"Nuclear myocardial perfusion imaging with a cadmium-zinc-telluride detector technique: Optimized protocol for scan time reduction","volume":"51","author":"Herzog","year":"2010","journal-title":"J Nucl Med"},{"key":"10.1007\/s12350-018-01585-9_bib18","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1161\/hc0402.102975","article-title":"Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association","volume":"105","author":"Cerqueira","year":"2002","journal-title":"Circulation"},{"key":"10.1007\/s12350-018-01585-9_bib19","first-page":"1630","article-title":"Quantitative analysis of regional motion and thickening by gated myocardial perfusion SPECT: Normal heterogeneity and criteria for abnormality","volume":"42","author":"Sharir","year":"2001","journal-title":"J Nucl Med"},{"key":"10.1007\/s12350-018-01585-9_bib20","first-page":"712","article-title":"A new algorithm for the quantitation of myocardial perfusion SPECT. I: Technical principles and reproducibility","volume":"41","author":"Germano","year":"2000","journal-title":"J Nucl Med"},{"key":"10.1007\/s12350-018-01585-9_bib21","doi-asserted-by":"crossref","first-page":"2423","DOI":"10.1007\/s00259-016-3467-5","article-title":"Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: A review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM)","volume":"43","author":"Agostini","year":"2016","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"10.1007\/s12350-018-01585-9_bib22","doi-asserted-by":"crossref","first-page":"1397","DOI":"10.1088\/0031-9155\/56\/5\/012","article-title":"Iterative deconvolution of simultaneous 99mTc and 201Tl projection data measured on a CdZnTe-based cardiac SPECT scanner","volume":"56","author":"Kacperski","year":"2011","journal-title":"Phys Med Biol"},{"key":"10.1007\/s12350-018-01585-9_bib23","doi-asserted-by":"crossref","first-page":"2635","DOI":"10.1088\/0031-9155\/54\/9\/003","article-title":"Performance evaluation of D-SPECT: A novel SPECT system for nuclear cardiology","volume":"54","author":"Erlandsson","year":"2009","journal-title":"Phys Med Biol"},{"key":"10.1007\/s12350-018-01585-9_bib24","doi-asserted-by":"crossref","first-page":"1710","DOI":"10.1007\/s00259-010-1441-1","article-title":"Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera","volume":"37","author":"Ben-Haim","year":"2010","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"10.1007\/s12350-018-01585-9_bib25","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1007\/s00259-009-1375-7","article-title":"Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: First clinical validation","volume":"37","author":"Buechel","year":"2010","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"10.1007\/s12350-018-01585-9_bib26","doi-asserted-by":"crossref","first-page":"1048","DOI":"10.1007\/s00259-012-2086-z","article-title":"Impact of a new ultrafast CZT SPECT camera for myocardial perfusion imaging: Fewer equivocal results and lower radiation dose","volume":"39","author":"Mouden","year":"2012","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"10.1007\/s12350-018-01585-9_bib27","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1161\/CIRCIMAGING.110.957399","article-title":"Comparison between ultrafast and standard single-photon emission CT in patients with coronary artery disease: A pilot study","volume":"4","author":"Gimelli","year":"2011","journal-title":"Circ Cardiovasc Imaging"},{"key":"10.1007\/s12350-018-01585-9_bib28","doi-asserted-by":"crossref","first-page":"1084","DOI":"10.1007\/s00259-013-2399-6","article-title":"Initial multicentre experience of high-speed myocardial perfusion imaging: Comparison between high-speed and conventional single-photon emission computed tomography with angiographic validation","volume":"40","author":"Neill","year":"2013","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"10.1007\/s12350-018-01585-9_bib29","doi-asserted-by":"crossref","first-page":"556","DOI":"10.2967\/jnumed.112.110577","article-title":"Absolute quantification of left ventricular global and regional function at nuclear MPI using ultrafast CZT SPECT: Initial validation vs cardiac MR","volume":"54","author":"Cochet","year":"2013","journal-title":"J Nucl Med"},{"key":"10.1007\/s12350-018-01585-9_bib30","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1007\/s12350-013-9844-6","article-title":"Gated tomographic radionuclide angiography using cadmium-zinc-telluride detector gamma camera; comparison to traditional gamma cameras","volume":"21","author":"Jensen","year":"2014","journal-title":"J Nucl Cardiol"},{"key":"10.1007\/s12350-018-01585-9_bib31","first-page":"1605","article-title":"Improved myocardial fatty acid utilization after percutaneous transluminal coronary angioplasty","volume":"36","author":"Matsunari","year":"1995","journal-title":"J Nucl Med"},{"key":"10.1007\/s12350-018-01585-9_bib32","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1007\/BF03164986","article-title":"Combined study with I-123 fatty acid and thallium-201 to assess ischemic myocardium: Comparison with thallium redistribution and glucose metabolism","volume":"8","author":"Kawamoto","year":"1994","journal-title":"Ann Nucl Med"},{"key":"10.1007\/s12350-018-01585-9_bib33","first-page":"1503","article-title":"Assessment of improvement of myocardial fatty acid uptake and function after revascularization using iodine-123-BMIPP","volume":"38","author":"Taki","year":"1997","journal-title":"J Nucl Med"},{"key":"10.1007\/s12350-018-01585-9_bib34","doi-asserted-by":"crossref","first-page":"1888","DOI":"10.1016\/S0735-1097(01)01634-5","article-title":"Significance of reduced uptake of iodinated fatty acid analogue for the evaluation of patients with acute chest pain","volume":"38","author":"Kawai","year":"2001","journal-title":"J Am Coll Cardiol"},{"key":"10.1007\/s12350-018-01585-9_bib35","doi-asserted-by":"crossref","first-page":"2092","DOI":"10.1016\/S0735-1097(99)00150-3","volume":"33","author":"Gibbons","year":"1999","journal-title":"J Am Coll Cardiol"},{"key":"10.1007\/s12350-018-01585-9_bib36","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1016\/j.amjcard.2003.12.003","volume":"93","author":"Iwado","year":"2004","journal-title":"Am J Cardiol"},{"key":"10.1007\/s12350-018-01585-9_bib37","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1007\/BF02987846","article-title":"Completely inverse images in dual-isotope SPECT with Tl-201 and I-123 MIBG in a patient with myocarditis","volume":"15","author":"Nakahara","year":"2001","journal-title":"Ann Nucl Med"},{"key":"10.1007\/s12350-018-01585-9_bib38","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1118\/1.3063544","article-title":"Quantitative simultaneous 99mTc\/123I cardiac SPECT using MC-JOSEM","volume":"36","author":"Ouyang","year":"2009","journal-title":"Med Phys"},{"key":"10.1007\/s12350-018-01585-9_bib39","doi-asserted-by":"crossref","first-page":"3530","DOI":"10.1118\/1.2768863","article-title":"Model-based crosstalk compensation for simultaneous 99mTc\/123I dual-isotope brain SPECT imaging","volume":"34","author":"Du","year":"2007","journal-title":"Med Phys"},{"key":"10.1007\/s12350-018-01585-9_bib40","doi-asserted-by":"crossref","first-page":"1692","DOI":"10.1007\/s12350-017-0841-z","article-title":"First assessment of simultaneous dual isotope ((123)I\/(99m)Tc) cardiac SPECT on two different CZT cameras: A phantom study","volume":"25","author":"Blaire","year":"2017","journal-title":"J Nucl Cardiol"},{"key":"10.1007\/s12350-018-01585-9_bib41","doi-asserted-by":"crossref","first-page":"1390","DOI":"10.1007\/s002590050313","article-title":"Use of 123I-BMIPP single-photon emission tomography to estimate areas at risk following successful revascularization in patients with acute myocardial infarction","volume":"25","author":"Kawai","year":"1998","journal-title":"Eur J Nucl Med"}],"container-title":["Journal of Nuclear Cardiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12350-018-01585-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s12350-018-01585-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1071358123007444?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1071358123007444?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12350-018-01585-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T06:07:32Z","timestamp":1761026852000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1071358123007444"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2]]},"references-count":41,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,2]]}},"alternative-id":["S1071358123007444"],"URL":"https:\/\/doi.org\/10.1007\/s12350-018-01585-9","relation":{},"ISSN":["1071-3581"],"issn-type":[{"value":"1071-3581","type":"print"}],"subject":[],"published":{"date-parts":[[2021,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Feasibility of simultaneous 99mTc-tetrofosmin and 123I-BMIPP dual-tracer imaging with cadmium-zinc-telluride detectors in patients undergoing primary coronary intervention for acute myocardial infarction","name":"articletitle","label":"Article Title"},{"value":"Journal of Nuclear Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1007\/s12350-018-01585-9","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2021 American Society of Nuclear Cardiology. Published by ELSEVIER INC. All rights reserved. Published by Mosby, Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}