{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T23:38:03Z","timestamp":1790725083036,"version":"4.1.0"},"reference-count":29,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2021,12,1]],"date-time":"2021-12-01T00:00:00Z","timestamp":1638316800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,12,1]],"date-time":"2021-12-01T00:00:00Z","timestamp":1638316800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["journals.elsevierhealth.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Nuclear Cardiology"],"published-print":{"date-parts":[[2021,12]]},"DOI":"10.1007\/s12350-020-02081-9","type":"journal-article","created":{"date-parts":[[2020,2,26]],"date-time":"2020-02-26T21:03:44Z","timestamp":1582751024000},"page":"2569-2577","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":9,"title":["The utility of heart-to-mediastinum ratio using a planar image created from IQ-SPECT with Iodine-123 meta-iodobenzylguanidine"],"prefix":"10.1016","volume":"28","author":[{"given":"Takayuki","family":"Shibutani","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenichi","family":"Nakajima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroto","family":"Yoneyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takahiro","family":"Konishi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koichi","family":"Okuda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masahisa","family":"Onoguchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seigo","family":"Kinuya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1007\/s12350-020-02081-9_bib1","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1136\/hrt.76.3.218","article-title":"Increased myocardial [123I]-metaiodobenzylguanidine uptake after enalapril treatment in patients with chronic heart failure","volume":"76","author":"Somsen","year":"1996","journal-title":"Heart"},{"key":"10.1007\/s12350-020-02081-9_bib2","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1007\/s12149-012-0662-8","article-title":"Iodine-123 metaiodobenzylguanidine imaging can predict future cardiac events in Japanese patients with Parkinson\u2019s disease","volume":"27","author":"Kinbara","year":"2013","journal-title":"Ann Nucl Med"},{"key":"10.1007\/s12350-020-02081-9_bib3","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0120540","article-title":"Diagnostic accuracy of 123I-meta-iodobenzylguanidine myocardial scintigraphy in dementia with Lewy bodies: a multicenter study","volume":"10","author":"Yoshita","year":"2015","journal-title":"PLoS ONE"},{"key":"10.1007\/s12350-020-02081-9_bib4","doi-asserted-by":"crossref","first-page":"1138","DOI":"10.1093\/ehjci\/jev322","article-title":"Creation of mortality risk charts using 123I meta-iodobenzylguanidine heart-to-mediastinum ratio in patients with heart failure: 2- and 5-year risk models","volume":"17","author":"Nakajima","year":"2016","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"10.1007\/s12350-020-02081-9_bib5","doi-asserted-by":"crossref","first-page":"1673","DOI":"10.1007\/s00259-014-2759-x","article-title":"A prediction model for 5-year cardiac mortality in patients with chronic heart failure using 123I-metaiodobenzylguanidine imaging","volume":"41","author":"Nakajima","year":"2014","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"10.1007\/s12350-020-02081-9_bib6","first-page":"378","article-title":"Iodine-123-MIBG sympathetic imaging in Lewy-body diseases and related movement disorders","volume":"52","author":"Nakajima","year":"2008","journal-title":"Q J Nucl Med Mol Imaging"},{"issue":"Suppl 4","key":"10.1007\/s12350-020-02081-9_bib7","doi-asserted-by":"crossref","first-page":"25S","DOI":"10.2967\/jnumed.115.157503","article-title":"123I-MIBG SPECT for evaluation of patients with heart failure","volume":"56","author":"Dimitriu-Leen","year":"2015","journal-title":"J Nucl Med."},{"key":"10.1007\/s12350-020-02081-9_bib8","article-title":"Role of cardiac 123I-mIBG imaging in predicting arrhythmic events in stable chronic heart failure patients with an ICD","author":"De Vincentis","year":"2018","journal-title":"J Nucl Cardiol"},{"key":"10.1007\/s12350-020-02081-9_bib9","first-page":"129","article-title":"Development of an 123I-metaiodobenzylguanidine myocardial three-dimensional quantification method for the diagnosis of lewy body disease","volume":"6","author":"Kamiya","year":"2018","journal-title":"Asia Ocean J Nucl Med Biol"},{"key":"10.1007\/s12350-020-02081-9_bib10","first-page":"1566","article-title":"Effect of patient motion on tomographic myocardial perfusion imaging","volume":"33","author":"Cooper","year":"1992","journal-title":"J Nucl Med"},{"key":"10.1007\/s12350-020-02081-9_bib11","first-page":"303","article-title":"A quantitative assessment of patient motion and its effect on myocardial perfusion SPECT images","volume":"34","author":"Botvinick","year":"1993","journal-title":"J Nucl Med"},{"key":"10.1007\/s12350-020-02081-9_bib12","doi-asserted-by":"crossref","first-page":"2635","DOI":"10.1088\/0031-9155\/54\/9\/003","article-title":"Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology","volume":"54","author":"Erlandsson","year":"2009","journal-title":"Phys Med Biol"},{"key":"10.1007\/s12350-020-02081-9_bib13","doi-asserted-by":"crossref","first-page":"2064","DOI":"10.2967\/jnumed.114.143560","article-title":"IQ SPECT allows a significant reduction in administered dose and acquisition time for myocardial perfusion imaging: evidence from a phantom study","volume":"55","author":"Caobelli","year":"2014","journal-title":"J Nucl Med"},{"key":"10.1007\/s12350-020-02081-9_bib14","doi-asserted-by":"crossref","unstructured":"Zeintl J, Rempel TD, Bhattacharya M, Malmin RE, Vija AH. Performance characteristics of the SMARTZOOM\u00ae collimator. Nuclear Science Symposium and Medical Imaging Conference (NSS\/MIC) IEEE 2011;2426-29.","DOI":"10.1109\/NSSMIC.2011.6152660"},{"key":"10.1007\/s12350-020-02081-9_bib15","doi-asserted-by":"crossref","first-page":"68","DOI":"10.17996\/ANC.02.01.68","article-title":"Technical aspects: image reconstruction","volume":"2","author":"Onoguchi","year":"2016","journal-title":"Ann Nucl Cardiol"},{"key":"10.1007\/s12350-020-02081-9_bib16","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1007\/s12149-018-1310-8","article-title":"Characteristics of iodine-123 IQ-SPECT\/CT imaging compared with conventional SPECT\/CT","volume":"33","author":"Shibutani","year":"2019","journal-title":"Ann Nucl Med"},{"issue":"1","key":"10.1007\/s12350-020-02081-9_bib17","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1007\/s00259-013-2549-x","article-title":"Feasibility of [(123)I]-meta-iodobenzylguanidine dynamic 3-D kinetic analysis in vivo using a CZT ultrafast camera: preliminary results","volume":"41","author":"Tinti","year":"2014","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"10.1007\/s12350-020-02081-9_bib18","doi-asserted-by":"crossref","first-page":"1912","DOI":"10.1007\/s00259-015-3141-3","article-title":"First determination of the heart-to-mediastinum ratio using cardiac dual isotope (123I-MIBG\/99mTc-tetrofosmin) CZT imaging in patients with heart failure: the ADRECARD study","volume":"42","author":"Bellevre","year":"2015","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"10.1007\/s12350-020-02081-9_bib19","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1007\/s12149-017-1191-2","article-title":"Cross calibration of 123I-meta-iodobenzylguanidine heart-to-mediastinum ratio with D-SPECT planogram and Anger camera","volume":"31","author":"Nakajima","year":"2017","journal-title":"Ann Nucl Med"},{"key":"10.1007\/s12350-020-02081-9_bib20","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1007\/s12350-010-9313-4","article-title":"Semi-automated algorithm for calculating heart-to-mediastinum ratio in cardiac Iodine-123 MIBG imaging","volume":"18","author":"Okuda","year":"2011","journal-title":"J Nucl Cardiol"},{"key":"10.1007\/s12350-020-02081-9_bib21","doi-asserted-by":"crossref","first-page":"970","DOI":"10.1007\/s12350-014-9916-2","article-title":"Multicenter cross-calibration of I-123 metaiodobenzylguanidine heart-to-mediastinum ratios to overcome camera-collimator variations","volume":"21","author":"Nakajima","year":"2014","journal-title":"J Nucl Cardiol"},{"key":"10.1007\/s12350-020-02081-9_bib22","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1007\/s40336-017-0230-2","article-title":"Standardization of 123I-meta-iodobenzylguanidine myocardial sympathetic activity imaging: phantom calibration and clinical applications","volume":"5","author":"Nakajima","year":"2017","journal-title":"Clin Transl Imaging"},{"key":"10.1007\/s12350-020-02081-9_bib23","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1016\/j.nuclcard.2007.08.002","article-title":"Correction of iodine-123-labeled meta-iodobenzylguanidine uptake with multi-window methods for standardization of the heart-to-mediastinum ratio","volume":"14","author":"Nakajima","year":"2007","journal-title":"J Nucl Cardiol"},{"key":"10.1007\/s12350-020-02081-9_bib24","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1212\/WNL.0000000000004058","article-title":"Diagnosis and management of dementia with Lewy bodies: Fourth consensus report of the DLB Consortium","volume":"89","author":"McKeith","year":"2017","journal-title":"Neurology"},{"key":"10.1007\/s12350-020-02081-9_bib25","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1016\/j.amjcard.2016.10.024","article-title":"Persistence of 123I-mIBG prognostic capability in relation to medical therapy in heart failure (from the ADMIRE-HF Trial)","volume":"119","author":"Pi\u00f1a","year":"2017","journal-title":"Am J Cardiol"},{"issue":"1","key":"10.1007\/s12350-020-02081-9_bib26","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1111\/ene.12022","article-title":"EFNS\/MDS-ES\/ENS [corrected] recommendations for the diagnosis of Parkinson\u2019s disease","volume":"20","author":"Berardelli","year":"2013","journal-title":"Eur J Neurol"},{"key":"10.1007\/s12350-020-02081-9_bib27","doi-asserted-by":"crossref","first-page":"1920","DOI":"10.1007\/s00259-015-3142-2","article-title":"Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT","volume":"42","author":"Caobelli","year":"2015","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"10.1007\/s12350-020-02081-9_bib28","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1007\/s12149-015-0965-7","article-title":"Nuclear myocardial perfusion imaging using thallium-201 with a novel multifocal collimator SPECT\/CT: IQ-SPECT versus conventional protocols in normal subjects","volume":"29","author":"Matsuo","year":"2015","journal-title":"Ann Nucl Med"},{"key":"10.1007\/s12350-020-02081-9_bib29","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1007\/s12149-017-1210-3","article-title":"IQ\u00b7SPECT technology and its clinical applications using multicenter normal databases","volume":"31","author":"Nakajima","year":"2017","journal-title":"Ann Nucl Med"}],"container-title":["Journal of Nuclear Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12350-020-02081-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12350-020-02081-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1071358123016537?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1071358123016537?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12350-020-02081-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,30]],"date-time":"2024-12-30T15:50:47Z","timestamp":1735573847000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1071358123016537"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12]]},"references-count":29,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["S1071358123016537"],"URL":"https:\/\/doi.org\/10.1007\/s12350-020-02081-9","relation":{},"ISSN":["1071-3581"],"issn-type":[{"value":"1071-3581","type":"print"}],"subject":[],"published":{"date-parts":[[2021,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The utility of heart-to-mediastinum ratio using a planar image created from IQ-SPECT with Iodine-123 meta-iodobenzylguanidine","name":"articletitle","label":"Article Title"},{"value":"Journal of Nuclear Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1007\/s12350-020-02081-9","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2021 American Society of Nuclear Cardiology. Published by ELSEVIER INC. All rights reserved. Published by Mosby, Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}