{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T01:03:11Z","timestamp":1767142991302,"version":"build-2238731810"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2017,2,15]],"date-time":"2017-02-15T00:00:00Z","timestamp":1487116800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Neth Heart J"],"published-print":{"date-parts":[[2017,6]]},"DOI":"10.1007\/s12471-017-0962-7","type":"journal-article","created":{"date-parts":[[2017,2,15]],"date-time":"2017-02-15T04:00:06Z","timestamp":1487131206000},"page":"388-393","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Use of three-dimensional computed tomography overlay for real-time cryoballoon ablation in atrial fibrillation reduces radiation dose and contrast dye"],"prefix":"10.1007","volume":"25","author":[{"given":"B.","family":"Oude Velthuis","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Molenaar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H. G.","family":"Reinhart Dorman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J. Y.","family":"Stevenhagen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M. F.","family":"Scholten","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"van der Palen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J. M.","family":"van Opstal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2017,2,15]]},"reference":[{"key":"962_CR1","doi-asserted-by":"crossref","unstructured":"Camm AJ, Lip GY, De CR, et\u00a0al. 2012 focused update of the ESC Guidelines for the management of atrial fibrillation: an update of the 2010 ESC Guidelines for the management of atrial fibrillation. Developed with the special contribution of the European Heart Rhythm Association. Eur Heart\u00a0J. 2012;33(21):2719\u201347.","DOI":"10.1093\/eurheartj\/ehs253"},{"key":"962_CR2","doi-asserted-by":"crossref","unstructured":"Haissaguerre M, Jais P, Shah DC, et\u00a0al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N\u00a0Engl J Med. 1998;339(10):659\u201366.","DOI":"10.1056\/NEJM199809033391003"},{"key":"962_CR3","doi-asserted-by":"crossref","unstructured":"Cosedis NJ, Johannessen A, Raatikainen P, et\u00a0al. Radiofrequency ablation as initial therapy in paroxysmal atrial fibrillation. N\u00a0Engl J Med. 2012;367(17):1587\u201395.","DOI":"10.1056\/NEJMoa1113566"},{"key":"962_CR4","doi-asserted-by":"crossref","unstructured":"Jais P, Cauchemez B, Macle L, et\u00a0al. Catheter ablation versus antiarrhythmic drugs for atrial fibrillation: the A4 study. Circulation. 2008;118(24):2498\u2013505.","DOI":"10.1161\/CIRCULATIONAHA.108.772582"},{"key":"962_CR5","doi-asserted-by":"crossref","unstructured":"Wilber DJ, Pappone C, Neuzil P, et\u00a0al. Comparison of antiarrhythmic drug therapy and radiofrequency catheter ablation in patients with paroxysmal atrial fibrillation: a\u00a0randomized controlled trial. JAMA. 2010;303(4):333\u201340.","DOI":"10.1001\/jama.2009.2029"},{"key":"962_CR6","doi-asserted-by":"crossref","unstructured":"Packer DL, Kowal RC, Wheelan KR, et\u00a0al. Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: first results of the North American Arctic Front (STOP AF) pivotal trial. J\u00a0Am Coll Cardiol. 2013;61(16):1713\u201323.","DOI":"10.1016\/j.jacc.2012.11.064"},{"key":"962_CR7","doi-asserted-by":"crossref","unstructured":"Andrade JG, Khairy P, Guerra PG, et\u00a0al. Efficacy and safety of cryoballoon ablation for atrial fibrillation: a\u00a0systematic review of published studies. Heart Rhythm. 2011;8(9):1444\u201351.","DOI":"10.1016\/j.hrthm.2011.03.050"},{"key":"962_CR8","doi-asserted-by":"crossref","unstructured":"Kuck KH, Brugada J, Furnkranz A, et\u00a0al. Cryoballoon or radiofrequency ablation for paroxysmal atrial fibrillation. N\u00a0Engl J Med. 2016;374(23):2235\u201345.","DOI":"10.1056\/NEJMoa1602014"},{"key":"962_CR9","doi-asserted-by":"crossref","unstructured":"Sarabanda AV, Bunch TJ, Johnson SB, et\u00a0al. Efficacy and safety of circumferential pulmonary vein isolation using a\u00a0novel cryothermal balloon ablation system. J\u00a0Am Coll Cardiol. 2005;46(10):1902\u201312.","DOI":"10.1016\/j.jacc.2005.07.046"},{"key":"962_CR10","doi-asserted-by":"crossref","unstructured":"Schmidt M, Dorwarth U, Andresen D, et\u00a0al. Cryoballoon versus RF ablation in paroxysmal atrial fibrillation: results from the German ablation registry. J\u00a0Cardiovasc Electrophysiol. 2014;25(1):1\u20137.","DOI":"10.1111\/jce.12267"},{"key":"962_CR11","doi-asserted-by":"crossref","unstructured":"Ottaviano L, Chierchia GB, Bregasi A, et al. Cryoballoon ablation for atrial fibrillation guided by real-time three-dimensional transoesophageal echocardiography: a\u00a0feasibility study. Europace. 2013;15(7):944\u201350.","DOI":"10.1093\/europace\/eus431"},{"key":"962_CR12","doi-asserted-by":"crossref","unstructured":"Stevenhagen J, Van Der Voort PH, Dekker LR, Bullens RW, Van Den Bosch H, Meijer A. Three-dimensional CT overlay in comparison to CartoMerge for pulmonary vein antrum isolation. J\u00a0Cardiovasc Electrophysiol. 2010;21(6):634\u20139.","DOI":"10.1111\/j.1540-8167.2009.01665.x"},{"key":"962_CR13","doi-asserted-by":"crossref","unstructured":"Camm AJ, Kirchhof P, Lip GY, et\u00a0al. Guidelines for the management of atrial fibrillation: the Task Force for the Management of Atrial Fibrillation of the European Society of Cardiology (ESC). Europace. 2010;12(10):1360\u2013420.","DOI":"10.1093\/europace\/euq350"},{"key":"962_CR14","doi-asserted-by":"crossref","unstructured":"Oude VB, Stevenhagen J, van Opstal JM, Scholten MF. Continuation of vitamin K antagonists as acceptable anticoagulation regimen in patients undergoing pulmonary vein isolation. Neth Heart\u00a0J. 2012;20(1):12\u20135.","DOI":"10.1007\/s12471-011-0223-0"},{"key":"962_CR15","doi-asserted-by":"crossref","unstructured":"Andrade JG, Dubuc M, Guerra PG,et al. Pulmonary vein isolation using a\u00a0second-generation cryoballoon catheter: a\u00a0randomized comparison of ablation duration and method of deflation. J\u00a0Cardiovasc Electrophysiol. 2013;24(6):692\u20138.","DOI":"10.1111\/jce.12114"},{"issue":"1\u20133","key":"962_CR16","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1093\/rpd\/nci753","volume":"117","author":"FW Schultz","year":"2005","unstructured":"Schultz FW, Zoetelief J. Dose conversion coefficients for interventional procedures. Radiat Prot Dosimetry. 2005;117(1\u20133):225\u201330.","journal-title":"Radiat Prot Dosimetry"},{"issue":"4","key":"962_CR17","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1111\/1754-9485.12036","volume":"57","author":"E Karaarslan","year":"2013","unstructured":"Karaarslan E, Ulus S, Bavbek C. Estimated radiation dose and image quality comparison of the scan protocols in dual-source computed tomography coronary angiography. J\u00a0Med Imaging Radiat Oncol. 2013;57(4):407\u201314.","journal-title":"J Med Imaging Radiat Oncol"},{"key":"962_CR18","doi-asserted-by":"crossref","unstructured":"Ector J, Dragusin O, Adriaenssens B, et\u00a0al. Obesity is a\u00a0major determinant of radiation dose in patients undergoing pulmonary vein isolation for atrial fibrillation. J\u00a0Am Coll Cardiol. 2007;50(3):234\u201342.","DOI":"10.1016\/j.jacc.2007.03.040"},{"issue":"8","key":"962_CR19","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1258\/jtt.2009.090402","volume":"15","author":"A Muller","year":"2009","unstructured":"Muller A, Scharner W, Borchardt T, Och W, Korb H. Reliability of an external loop recorder for automatic recognition and transtelephonic ECG transmission of atrial fibrillation. J\u00a0Telemed Telecare. 2009;15(8):391\u20136.","journal-title":"J Telemed Telecare"},{"key":"962_CR20","doi-asserted-by":"crossref","unstructured":"Velthuis BO, Bos J, Kraaier K, et\u00a0al. Performance of an external transtelephonic loop recorder for automated detection of paroxysmal atrial fibrillation. Ann Noninvasive Electrocardiol. 2013;18(6):564\u201370.","DOI":"10.1111\/anec.12075"},{"key":"962_CR21","volume-title":"High incidence of low esophageal temperatures during cryoballoon therapy for atrial fibrillation","author":"MMD Molenaar","year":"2014","unstructured":"Molenaar MMD, Scholten MF, Hesselink T, Stevenhagen YJ, van Opstal JM. High incidence of low esophageal temperatures during cryoballoon therapy for atrial fibrillation. HRS Boston, Ref Type: Abstract, 8\u20111-2014. 2014."},{"issue":"15","key":"962_CR22","doi-asserted-by":"crossref","first-page":"1419","DOI":"10.1016\/j.jacc.2007.12.035","volume":"51","author":"PA McCullough","year":"2008","unstructured":"McCullough PA. Contrast-induced acute kidney injury. J\u00a0Am Coll Cardiol. 2008;51(15):1419\u201328.","journal-title":"J Am Coll Cardiol"},{"key":"962_CR23","doi-asserted-by":"crossref","unstructured":"Kuwahara T, Takahashi A, Takahashi Y, et\u00a0al. Clinical characteristics and management of periesophageal vagal nerve injury complicating left atrial ablation of atrial fibrillation: lessons from eleven cases. J\u00a0Cardiovasc Electrophysiol. 2013;24(8):847\u201351.","DOI":"10.1111\/jce.12130"},{"key":"962_CR24","doi-asserted-by":"crossref","unstructured":"Metzner A, Burchard A, Wohlmuth P, et al. Increased incidence of esophageal thermal lesions using the second-generation 28-mm cryoballoon. Circ Arrhythm Electrophysiol. 2013;6(4):769\u201375.","DOI":"10.1161\/CIRCEP.113.000228"}],"updated-by":[{"DOI":"10.1007\/s12471-017-1013-0","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2017,6,19]],"date-time":"2017-06-19T00:00:00Z","timestamp":1497830400000}}],"container-title":["Netherlands Heart Journal"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s12471-017-0962-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12471-017-0962-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12471-017-0962-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,18]],"date-time":"2019-09-18T14:11:47Z","timestamp":1568815907000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s12471-017-0962-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,2,15]]},"references-count":24,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2017,6]]}},"alternative-id":["962"],"URL":"https:\/\/doi.org\/10.1007\/s12471-017-0962-7","relation":{},"ISSN":["1568-5888","1876-6250"],"issn-type":[{"value":"1568-5888","type":"print"},{"value":"1876-6250","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,2,15]]}}}