{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T11:05:39Z","timestamp":1782990339182,"version":"3.54.5"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2012,5,4]],"date-time":"2012-05-04T00:00:00Z","timestamp":1336089600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Can J Anesth\/J Can Anesth"],"published-print":{"date-parts":[[2012,7]]},"DOI":"10.1007\/s12630-012-9718-4","type":"journal-article","created":{"date-parts":[[2012,5,3]],"date-time":"2012-05-03T15:25:29Z","timestamp":1336058729000},"page":"648-654","source":"Crossref","is-referenced-by-count":55,"title":["The LMA Supreme\u2122 in 700 parturients undergoing Cesarean delivery: an observational study","Utilisation du LMA Supreme\u2122 chez 700\u00a0parturientes accouchant par c\u00e9sarienne: une \u00e9tude observationnelle"],"prefix":"10.1007","volume":"59","author":[{"given":"Wei Yu","family":"Yao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shi Yang","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ban Leong","family":"Sng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yvonne","family":"Lim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alex Tiong Heng","family":"Sia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2012,5,4]]},"reference":[{"key":"9718_CR1","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1093\/bja\/aen174","volume":"101","author":"C Verghese","year":"2008","unstructured":"Verghese C, Ramaswamy B. LMA-Supreme\u2013a new single-use LMA with gastric access: a report on its clinical efficacy. Br J Anaesth 2008; 101: 405-10.","journal-title":"Br J Anaesth"},{"key":"9718_CR2","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1097\/EJA.0b013e32833679e3","volume":"27","author":"E Seet","year":"2010","unstructured":"Seet E, Rajeev S, Firoz T, et al. Safety and efficacy of laryngeal mask airway Supreme versus laryngeal mask airway ProSeal: a randomized controlled trial. Eur J Anaesthesiol 2010; 27: 602-7.","journal-title":"Eur J Anaesthesiol"},{"key":"9718_CR3","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1177\/0310057X0903700537","volume":"37","author":"AK Lee","year":"2009","unstructured":"Lee AK, Tey JB, Lim Y, Sia AT. Comparison of the single-use LMA supreme with the reusable ProSeal LMA for anaesthesia in gynaecological laparoscopic surgery. Anaesth Intensive Care 2009; 37: 815-9.","journal-title":"Anaesth Intensive Care"},{"key":"9718_CR4","doi-asserted-by":"crossref","first-page":"852","DOI":"10.1111\/j.1399-6576.2009.01986.x","volume":"53","author":"T Hosten","year":"2009","unstructured":"Hosten T, Gurkan Y, Ozdamar D, Tekin M, Toker K, Solak M. A new supraglottic airway device: LMA-supreme, comparison with LMA-Proseal. Acta Anaesthesiol Scand 2009; 53: 852-7.","journal-title":"Acta Anaesthesiol Scand"},{"key":"9718_CR5","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1111\/j.1365-2044.2008.05682.x","volume":"64","author":"S Eschertzhuber","year":"2009","unstructured":"Eschertzhuber S, Brimacombe J, Hohlrieder M, Keller C. The laryngeal mask airway Supreme\u2013a single use laryngeal mask airway with an oesophageal vent. A randomised, cross-over study with the laryngeal mask airway ProSeal in paralysed, anaesthetised patients. Anaesthesia 2009; 64: 79-83.","journal-title":"Anaesthesia"},{"key":"9718_CR6","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1111\/j.1365-2044.2008.05824.x","volume":"64","author":"TM Cook","year":"2009","unstructured":"Cook TM, Gatward JJ, Handel J, et al. Evaluation of the LMA Supreme in 100 non-paralysed patients. Anaesthesia 2009; 64: 555-62.","journal-title":"Anaesthesia"},{"key":"9718_CR7","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1097\/ALN.0b013e3181a4c6b9","volume":"111","author":"LG Theiler","year":"2009","unstructured":"Theiler LG, Kleine-Brueggeney M, Kaiser D, et al. Crossover comparison of the laryngeal mask supreme and the i-gel in simulated difficult airway scenario in anesthetized patients. Anesthesiology 2009; 111: 55-62.","journal-title":"Anesthesiology"},{"key":"9718_CR8","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1111\/j.1399-6576.2009.02095.x","volume":"54","author":"W Abdi","year":"2010","unstructured":"Abdi W, Amathieu R, Adhoum A, et al. Sparing the larynx during gynecological laparoscopy: a randomized trial comparing the LMA Supreme and the ETT. Acta Anaesthesiol Scand 2010; 54: 141-6.","journal-title":"Acta Anaesthesiol Scand"},{"key":"9718_CR9","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1007\/BF03020191","volume":"50","author":"JR Maltby","year":"2003","unstructured":"Maltby JR, Beriault MT, Watson NC, Liepert DJ, Fick GH. LMA-Classic and LMA-ProSeal are effective alternatives to endotracheal intubation for gynecologic laparoscopy. Can J Anesth 2003; 50: 71-7.","journal-title":"Can J Anesth"},{"key":"9718_CR10","doi-asserted-by":"crossref","first-page":"1624","DOI":"10.1007\/s11695-009-9953-0","volume":"19","author":"W Abdi","year":"2009","unstructured":"Abdi W, Dhonneur G, Amathieu R, et al. LMA supreme versus facemask ventilation performed by novices: a comparative study in morbidly obese patients showing difficult ventilation predictors. Obes Surg 2009; 19: 1624-30.","journal-title":"Obes Surg"},{"key":"9718_CR11","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1111\/j.1365-2044.2009.06185.x","volume":"65","author":"AM Lopez","year":"2010","unstructured":"Lopez AM, Valero R, Brimacombe J. Insertion and use of the LMA Supreme in the prone position. Anaesthesia 2010; 65: 154-7.","journal-title":"Anaesthesia"},{"key":"9718_CR12","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1093\/bja\/aeq118","volume":"105","author":"V Sharma","year":"2010","unstructured":"Sharma V, Verghese C, McKenna PJ. Prospective audit on the use of the LMA-Supreme for airway management of adult patients undergoing elective orthopaedic surgery in prone position. Br J Anaesth 2010; 105: 228-32.","journal-title":"Br J Anaesth"},{"key":"9718_CR13","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1016\/j.resuscitation.2010.06.001","volume":"81","author":"D Braude","year":"2010","unstructured":"Braude D, Southard A, Bajema T, Sims E, Martinez J. Rapid sequence airway using the LMA-Supreme as a primary airway for 9\u00a0h in a multi-system trauma patient. Resuscitation 2010; 81: 1217.","journal-title":"Resuscitation"},{"key":"9718_CR14","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1016\/j.ijoa.2006.04.010","volume":"15","author":"B Sharma","year":"2006","unstructured":"Sharma B, Sahai C, Sood J, Kumra VP. The ProSeal laryngeal mask airway in two failed obstetric tracheal intubation scenarios. Int J Obstet Anesth 2006; 15: 338-9.","journal-title":"Int J Obstet Anesth"},{"key":"9718_CR15","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1007\/BF03015775","volume":"52","author":"TM Cook","year":"2005","unstructured":"Cook TM, Brooks TS, Van der Westhuizen J, Clarke M. The Proseal LMA is a useful rescue device during failed rapid sequence intubation: two additional cases. Can J Anesth 2005; 52: 630-3.","journal-title":"Can J Anesth"},{"key":"9718_CR16","doi-asserted-by":"crossref","unstructured":"Vaida SJ, Gaitini LA. Another case of use of the ProSeal laryngeal mask airway in a difficult obstetric airway. Br J Anaesth 2004; 92: 905; author reply 905.","DOI":"10.1093\/bja\/aeh569"},{"key":"9718_CR17","doi-asserted-by":"crossref","unstructured":"Bullingham A. Use of the ProSeal laryngeal mask airway for airway maintenance during emergency caesarean section after failed intubation. Br J Anaesth 2004; 92: 903; author reply 904.","DOI":"10.1093\/bja\/aeh560"},{"key":"9718_CR18","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1093\/bja\/aeh019","volume":"92","author":"R Awan","year":"2004","unstructured":"Awan R, Nolan JP, Cook TM. Use of a ProSeal laryngeal mask airway for airway maintenance during emergency caesarean section after failed tracheal intubation. Br J Anaesth 2004; 92: 144-6.","journal-title":"Br J Anaesth"},{"key":"9718_CR19","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.ijoa.2004.10.007","volume":"14","author":"NR Evans","year":"2005","unstructured":"Evans NR, Skowno JJ, Bennett PJ, James MF, Dyer RA. A prospective observational study of the use of the Proseal laryngeal mask airway for postpartum tubal ligation. Int J Obstet Anesth 2005; 14: 90-5.","journal-title":"Int J Obstet Anesth"},{"key":"9718_CR20","doi-asserted-by":"crossref","first-page":"1010","DOI":"10.1097\/EJA.0b013e3283313fdd","volume":"26","author":"A Ali","year":"2009","unstructured":"Ali A, Canturk S, Turkmen A, Turgut N, Altan A. Comparison of the laryngeal mask airway Supreme and laryngeal mask airway Classic in adults. Eur J Anaesthesiol 2009; 26: 1010-4.","journal-title":"Eur J Anaesthesiol"},{"key":"9718_CR21","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1136\/gut.28.5.519","volume":"28","author":"JS Caestecker de","year":"1987","unstructured":"de Caestecker JS, Blackwell JN, Pryde A, Heading RC. Daytime gastro-oesophageal reflux is important in oesophagitis. Gut 1987; 28: 519-26.","journal-title":"Gut"},{"key":"9718_CR22","doi-asserted-by":"crossref","first-page":"1017","DOI":"10.1097\/00000539-200010000-00046","volume":"91","author":"C Keller","year":"2000","unstructured":"Keller C, Brimacombe J, Kleinsasser A, Loeckinger A. Does the ProSeal laryngeal mask airway prevent aspiration of regurgitated fluid? Anesth Analg 2000; 91: 1017-20.","journal-title":"Anesth Analg"},{"key":"9718_CR23","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1177\/0310057X0703500106","volume":"35","author":"Y Lim","year":"2007","unstructured":"Lim Y, Goel S, Brimacombe JR. The ProSeal laryngeal mask airway is an effective alternative to laryngoscope-guided tracheal intubation for gynaecological laparoscopy. Anaesth Intensive Care 2007; 35: 52-6.","journal-title":"Anaesth Intensive Care"},{"key":"9718_CR24","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1213\/ane.0b013e3181602ae1","volume":"106","author":"S Bercker","year":"2008","unstructured":"Bercker S, Schmidbauer W, Volk T, et al. A comparison of seal in seven supraglottic airway devices using a cadaver model of elevated esophageal pressure. Anesth Analg 2008; 106: 445-8.","journal-title":"Anesth Analg"},{"key":"9718_CR25","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1093\/bja\/aen319","volume":"102","author":"W Schmidbauer","year":"2009","unstructured":"Schmidbauer W, Bercker S, Volk T, Bogusch G, Mager G, Kerner T. Oesophageal seal of the novel supralaryngeal airway device I-Gel in comparison with the laryngeal mask airways Classic and ProSeal using a cadaver model. Br J Anaesth 2009; 102: 135-9.","journal-title":"Br J Anaesth"},{"key":"9718_CR26","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1093\/bja\/88.4.584","volume":"88","author":"NR Evans","year":"2002","unstructured":"Evans NR, Gardner SV, James MF. ProSeal laryngeal mask protects against aspiration of fluid in the pharynx. Br J Anaesth 2002; 88: 584-7.","journal-title":"Br J Anaesth"},{"key":"9718_CR27","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1016\/j.jclinane.2008.12.015","volume":"21","author":"SJ Vaida","year":"2009","unstructured":"Vaida SJ, Pott LM, Budde AO, Gaitini LA. Suggested algorithm for management of the unexpected difficult airway in obstetric anesthesia. J Clin Anesth 2009; 21: 385-6.","journal-title":"J Clin Anesth"},{"key":"9718_CR28","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/S0002-9378(16)39829-5","volume":"52","author":"CL Mendelson","year":"1946","unstructured":"Mendelson CL. The aspiration of stomach contents into the lungs during obstetric anesthesia. Am J Obstet Gynecol 1946; 52: 191-205.","journal-title":"Am J Obstet Gynecol"},{"key":"9718_CR29","doi-asserted-by":"crossref","first-page":"1117","DOI":"10.1007\/BF03020379","volume":"48","author":"TH Han","year":"2001","unstructured":"Han TH, Brimacombe J, Lee EJ, Yang HS. The laryngeal mask airway is effective (and probably safe) in selected healthy parturients for elective cesarean section: a prospective study of 1067 cases. Can J Anesth 2001; 48: 1117-21.","journal-title":"Can J Anesth"},{"key":"9718_CR30","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1177\/0310057X1003800610","volume":"38","author":"BK Halaseh","year":"2010","unstructured":"Halaseh BK, Sukkar ZF, Hassan LH, Sia AT, Bushnaq WA, Adarbeh H. The use of ProSeal laryngeal mask airway in caesarean section\u2013experience in 3000 cases. Anaesth Intensive Care 2010; 38: 1023-8.","journal-title":"Anaesth Intensive Care"},{"key":"9718_CR31","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1111\/j.1365-2044.1985.tb11000.x","volume":"40","author":"G Lyons","year":"1985","unstructured":"Lyons G. Failed intubation. Six years\u2019 experience in a teaching maternity unit. Anaesthesia 1985; 40: 759-62.","journal-title":"Anaesthesia"},{"key":"9718_CR32","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1111\/j.1365-2044.1987.tb04039.x","volume":"42","author":"GL Samsoon","year":"1987","unstructured":"Samsoon GL, Young JR. Difficult tracheal intubation: a retrospective study. Anaesthesia 1987; 42: 487-90.","journal-title":"Anaesthesia"},{"key":"9718_CR33","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1046\/j.1365-2044.2000.01536.x","volume":"55","author":"PD Barnardo","year":"2000","unstructured":"Barnardo PD, Jenkins JG. Failed tracheal intubation in obstetrics: a 6-year review in a UK region. Anaesthesia 2000; 55: 690-4.","journal-title":"Anaesthesia"},{"key":"9718_CR34","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1097\/00006250-199102000-00030","volume":"77","author":"KW Elkington","year":"1991","unstructured":"Elkington KW. At the water\u2019s edge: where obstetrics and anesthesia meet. Obstet Gynecol 1991; 77: 304-8.","journal-title":"Obstet Gynecol"},{"key":"9718_CR35","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1093\/bja\/55.5.367","volume":"55","author":"AR Hunter","year":"1983","unstructured":"Hunter AR, Moir DD. Confidential enquiry into maternal deaths. Br J Anaesth 1983; 55: 367-9.","journal-title":"Br J Anaesth"},{"key":"9718_CR36","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1016\/0002-9378(89)90355-4","volume":"161","author":"WJ May","year":"1989","unstructured":"May WJ, Greiss FC Jr. Maternal mortality in North Carolina: a forty-year experience. Am J Obstet Gynecol 1989; 161: 555-60. discussion 560-1.","journal-title":"Am J Obstet Gynecol"},{"key":"9718_CR37","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1111\/j.1365-2044.1984.tb08932.x","volume":"39","author":"RS Cormack","year":"1984","unstructured":"Cormack RS, Lehane J. Difficult tracheal intubation in obstetrics. Anaesthesia 1984; 39: 1105-11.","journal-title":"Anaesthesia"}],"container-title":["Canadian Journal of Anesthesia\/Journal canadien d'anesth\u00e9sie"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12630-012-9718-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s12630-012-9718-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12630-012-9718-4","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,28]],"date-time":"2019-06-28T02:15:17Z","timestamp":1561688117000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s12630-012-9718-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,5,4]]},"references-count":37,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2012,7]]}},"alternative-id":["9718"],"URL":"https:\/\/doi.org\/10.1007\/s12630-012-9718-4","relation":{"has-review":[{"id-type":"doi","id":"10.3410\/f.716497802.791902806","asserted-by":"object"},{"id-type":"doi","id":"10.3410\/f.716497802.793302815","asserted-by":"object"}]},"ISSN":["0832-610X","1496-8975"],"issn-type":[{"value":"0832-610X","type":"print"},{"value":"1496-8975","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,5,4]]}}}