{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T01:25:53Z","timestamp":1793841953333,"version":"4.6.1"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2020,3,9]],"date-time":"2020-03-09T00:00:00Z","timestamp":1583712000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,3,9]],"date-time":"2020-03-09T00:00:00Z","timestamp":1583712000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Can J Anesth\/J Can Anesth"],"published-print":{"date-parts":[[2020,5]]},"DOI":"10.1007\/s12630-020-01583-x","type":"journal-article","created":{"date-parts":[[2020,3,9]],"date-time":"2020-03-09T19:02:42Z","timestamp":1583780562000},"page":"515-520","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":26,"title":["Direct versus indirect laryngoscopy using a Macintosh video laryngoscope: a mannequin study comparing applied forces","Laryngoscopie directe versus indirecte \u00e0 l\u2019aide d\u2019un vid\u00e9olaryngoscope Macintosh: une \u00e9tude sur mannequin comparant les forces appliqu\u00e9es"],"prefix":"10.1007","volume":"67","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1904-5973","authenticated-orcid":false,"given":"Joanna K.","family":"Gordon","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vaughan E.","family":"Bertram","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Cavallin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matteo","family":"Parotto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard M.","family":"Cooper","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,3,9]]},"reference":[{"key":"1583_CR1","doi-asserted-by":"crossref","unstructured":"Prys-Roberts C, Greene LT, Miloche R, Foex P. Studies of anaesthesia in relation to hypertension. II. Haemodynamic consequences of induction and endotracheal intubation. Br J Anaesth 1971; 43: 531-47.","DOI":"10.1093\/bja\/43.6.531"},{"key":"1583_CR2","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1093\/bja\/59.3.295","volume":"59","author":"AJ Shribman","year":"1987","unstructured":"Shribman AJ, Smith G, Achola KJ. Cardiovascular and catecholamine responses to laryngoscopy with and without tracheal intubation. Br J Anaesth 1987; 59: 295-9.","journal-title":"Br J Anaesth"},{"key":"1583_CR3","doi-asserted-by":"publisher","first-page":"855","DOI":"10.1093\/bja\/55.9.855","volume":"55","author":"DR Derbyshire","year":"1983","unstructured":"Derbyshire DR, Chmielewski A, Fell D, Vater M, Achola K, Smith G. Plasma catecholamine responses to tracheal intubation. Br J Anaesth 1983; 55: 855-60.","journal-title":"Br J Anaesth"},{"key":"1583_CR4","doi-asserted-by":"crossref","unstructured":"Hassan HG, El-Sharkawy TY, Renck H, Mansour G, Fouda A. Hemodynamic and catecholamine responses to laryngoscopy with vs. without endotracheal intubation. Acta Anaesthesiol Scand 1991; 35: 442-7.","DOI":"10.1111\/j.1399-6576.1991.tb03325.x"},{"key":"1583_CR5","doi-asserted-by":"publisher","first-page":"492","DOI":"10.1111\/anae.12209","volume":"68","author":"C Lee","year":"2013","unstructured":"Lee C, Russell T, Firat M, Cooper RM. Forces generated by Macintosh and GlideScope\u00ae laryngoscopes in four airway-training manikins. Anaesthesia 2013; 68: 492-6.","journal-title":"Anaesthesia"},{"key":"1583_CR6","doi-asserted-by":"publisher","first-page":"626","DOI":"10.1111\/j.1365-2044.2012.07087.x","volume":"67","author":"T Russell","year":"2012","unstructured":"Russell T, Khan S, Elman J, Katznelson R, Cooper RM. Measurement of forces applied during Macintosh direct laryngoscopy compared with GlideScope\u00ae videolaryngoscopy. Anaesthesia 2012; 67: 626-31.","journal-title":"Anaesthesia"},{"key":"1583_CR7","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1097\/EJA.0000000000000901","volume":"36","author":"D Cordovani","year":"2019","unstructured":"Cordovani D, Russell T, Wee W, Suen A, Cooper RM. Measurement of forces applied using a Macintosh direct laryngoscope compared with a Glidescope video laryngoscope in patients with predictors of difficult laryngoscopy: a randomised controlled trial. Eur J Anaesthesiol 2019; 36: 221-6.","journal-title":"Eur J Anaesthesiol"},{"key":"1583_CR8","doi-asserted-by":"publisher","first-page":"1009","DOI":"10.1046\/j.1365-2044.1999.1133f.x","volume":"54","author":"RM Levitan","year":"1999","unstructured":"Levitan RM, Hollander JE, Ochroch EA. A grading system for direct laryngoscopy. Anaesthesia 1999; 54: 1009-10.","journal-title":"Anaesthesia"},{"key":"1583_CR9","unstructured":"R Core Team. R: A language and environment for statistical computing. R Foundation for Statistical Computing, Vienna, Austria, 2018. Available from URL: https:\/\/www.R-project.org\/ (accessed November 2019)."},{"key":"1583_CR10","doi-asserted-by":"publisher","first-page":"712","DOI":"10.1016\/j.bja.2017.12.041","volume":"120","author":"N Arulkumaran","year":"2018","unstructured":"Arulkumaran N, Lowe J, Ions R, Mendoza M, Bennett V, Dunser MW. Videolaryngoscopy versus direct laryngoscopy for emergency orotracheal intubation outside the operating room: a systematic review and meta-analysis. Br J Anaesth 2018; 120: 712-24.","journal-title":"Br J Anaesth"},{"key":"1583_CR11","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1093\/bja\/aev188","volume":"115","author":"FE Kelly","year":"2015","unstructured":"Kelly FE, Cook TM, Boniface N, Hughes J, Seller C, Simpson T. Videolaryngoscopes confer benefits in human factors in addition to technical skills. Br J Anaesth 2015; 115: 132-3.","journal-title":"Br J Anaesth"},{"key":"1583_CR12","doi-asserted-by":"publisher","first-page":"1098","DOI":"10.1177\/0310057X1103900619","volume":"39","author":"T Russell","year":"2011","unstructured":"Russell T, Lee C, Firat M, Cooper RM. A comparison of the forces applied to a manikin during laryngoscopy with the GlideScope and Macintosh laryngoscopes. Anaesth Intensive Care 2011; 39: 1098-102.","journal-title":"Anaesth Intensive Care"},{"key":"1583_CR13","first-page":"462","volume":"82","author":"RH Hastings","year":"1996","unstructured":"Hastings RH, Hon ED, Nghiem C, Wahrenbrock EA. Force and torque vary between laryngoscopists and laryngoscope blades. Anesth Analg 1996; 82: 462-8.","journal-title":"Anesth Analg"},{"key":"1583_CR14","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1097\/00000542-200308000-00005","volume":"99","author":"A Tanaka","year":"2003","unstructured":"Tanaka A, Isono S, Ishikawa T, Sato J, Nishino T. Laryngeal resistance before and after minor surgery: endotracheal tube versus Laryngeal Mask Airway. Anesthesiology 2003; 99: 252-8.","journal-title":"Anesthesiology"},{"key":"1583_CR15","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.1097\/00000542-200305000-00005","volume":"98","author":"T Mencke","year":"2003","unstructured":"Mencke T, Echternach M, Kleinschmidt S, et al. Laryngeal morbidity and quality of tracheal intubation: a randomized controlled trial. Anesthesiology 2003; 98: 1049-56.","journal-title":"Anesthesiology"},{"key":"1583_CR16","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1093\/bja\/aeu313","volume":"113","author":"JJ Pandit","year":"2014","unstructured":"Pandit JJ, Andrade J, Bogod DG, et al. 5th National Audit Project (NAP5) on accidental awareness during general anaesthesia: summary of main findings and risk factors. Br J Anaesth 2014; 113: 549-59.","journal-title":"Br J Anaesth"},{"key":"1583_CR17","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1097\/ALN.0b013e318190b556","volume":"110","author":"BG Santoni","year":"2009","unstructured":"Santoni BG, Hindman BJ, Puttlitz CM, et al. Manual in-line stabilization increases pressures applied by the laryngoscope blade during direct laryngoscopy and orotracheal intubation. Anesthesiology 2009; 110: 24-31.","journal-title":"Anesthesiology"},{"key":"1583_CR18","doi-asserted-by":"crossref","unstructured":"Ward PA, Irwin MG. Man vs. manikin revisited - the ethical boundaries of simulating difficult airways in patients. Anaesthesia 2016; 71: 1399-403.","DOI":"10.1111\/anae.13526"},{"key":"1583_CR19","doi-asserted-by":"publisher","first-page":"886","DOI":"10.1093\/bja\/86.6.886","volume":"86","author":"M Mercer","year":"2001","unstructured":"Mercer M. Respiratory failure after tracheal extubation in a patient with halo frame cervical spine immobilization\u2013rescue therapy using the Combitube airway. Br J Anaesth 2001; 86: 886-91.","journal-title":"Br J Anaesth"},{"key":"1583_CR20","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1136\/emj.2008.066456","volume":"27","author":"JH Yang","year":"2010","unstructured":"Yang JH, Kim YM, Chung HS, et al. Comparison of four manikins and fresh frozen cadaver models for direct laryngoscopic orotracheal intubation training. Emerg Med J 2010; 27: 13-6.","journal-title":"Emerg Med J"}],"container-title":["Canadian Journal of Anesthesia\/Journal canadien d'anesth\u00e9sie"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12630-020-01583-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s12630-020-01583-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12630-020-01583-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,9]],"date-time":"2021-03-09T01:03:32Z","timestamp":1615251812000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s12630-020-01583-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,3,9]]},"references-count":20,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2020,5]]}},"alternative-id":["1583"],"URL":"https:\/\/doi.org\/10.1007\/s12630-020-01583-x","relation":{},"ISSN":["0832-610X","1496-8975"],"issn-type":[{"value":"0832-610X","type":"print"},{"value":"1496-8975","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,3,9]]},"assertion":[{"value":"16 December 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 November 2019","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 January 2020","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 March 2020","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This content has been made available to all.","name":"free","label":"Free to read"}]}}