{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T16:39:35Z","timestamp":1740155975506,"version":"3.37.3"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2020,8,19]],"date-time":"2020-08-19T00:00:00Z","timestamp":1597795200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,8,19]],"date-time":"2020-08-19T00:00:00Z","timestamp":1597795200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Can J Anesth\/J Can Anesth"],"published-print":{"date-parts":[[2020,11]]},"DOI":"10.1007\/s12630-020-01778-2","type":"journal-article","created":{"date-parts":[[2020,8,19]],"date-time":"2020-08-19T21:03:24Z","timestamp":1597871004000},"page":"1515-1523","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Simultaneous en bloc endotracheal tube insertion with GlideScope\u00ae Titanium\u2122 video laryngoscope use: a randomized-controlled trial","Insertion simultan\u00e9e \u2018en bloc\u2019 du tube endotrach\u00e9al et du vid\u00e9olaryngoscope GlideScope\u00ae Titanium\u2122\u00a0: une \u00e9tude randomis\u00e9e contr\u00f4l\u00e9e"],"prefix":"10.1007","volume":"67","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4615-9415","authenticated-orcid":false,"given":"Timothy P.","family":"Turkstra","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel C.","family":"Turkstra","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexander W.","family":"Pavlosky","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philip M.","family":"Jones","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,8,19]]},"reference":[{"key":"1778_CR1","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1093\/bja\/aei041","volume":"94","author":"DA Sun","year":"2005","unstructured":"Sun DA, Warriner CB, Parsons DG, Klein R, Umedaly HS, Moult M. The GlideScope video laryngoscope: randomized clinical trial in 200 patients. Br J Anaesth 2005; 94: 381-4.","journal-title":"Br J Anaesth"},{"key":"1778_CR2","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1007\/BF03027728","volume":"52","author":"RM Cooper","year":"2005","unstructured":"Cooper RM, Pacey JA, Bishop MJ, McCluskey SA. Early clinical experience with a new videolaryngoscope (GlideScope) in 728 patients. Can J Anesth 2005; 52: 191-8.","journal-title":"Can J Anesth"},{"key":"1778_CR3","first-page":"451","volume":"73","author":"FS Xue","year":"2007","unstructured":"Xue FS, Zhang GH, Liu J, et al. The clinical assessment of Glidescope in orotracheal intubation under general anesthesia. Minerva Anestesiol 2007; 73: 451-7.","journal-title":"Minerva Anestesiol"},{"key":"1778_CR4","doi-asserted-by":"crossref","unstructured":"Andersen LH, Rovsing L, Olsen KS. GlideScope videolaryngoscope vs. Macintosh direct laryngoscope for intubation of morbidly obese patients: a randomized trial. Acta Anaesthesiol Scand 2011; 55: 1090-7.","DOI":"10.1111\/j.1399-6576.2011.02498.x"},{"key":"1778_CR5","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1007\/s12630-011-9620-5","volume":"59","author":"DE Griesdale","year":"2012","unstructured":"Griesdale DE, Liu D, McKinney J, Choi PT. Glidescope\u00ae video-laryngoscopy versus direct laryngoscopy for endotracheal intubation: a systematic review and meta-analysis. Can J Anesth 2012; 59: 41-52.","journal-title":"Can J Anesth"},{"key":"1778_CR6","doi-asserted-by":"publisher","first-page":"1105","DOI":"10.1111\/j.1365-2044.1984.tb08932.x","volume":"39","author":"RS Cormack","year":"1984","unstructured":"Cormack RS, Lehane J. Difficult tracheal intubation in obstetrics. Anaesthesia 1984; 39: 1105-11.","journal-title":"Anaesthesia"},{"key":"1778_CR7","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.1007\/s12630-013-0020-x","volume":"60","author":"JA Law","year":"2013","unstructured":"Law JA, Broemling N, Cooper RM, et al. The difficult airway with recommendations for management-part 2: the anticipated difficult airway. Can J Anesth 2013; 60: 1119-38.","journal-title":"Can J Anesth"},{"key":"1778_CR8","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1097\/ALN.0b013e31828604c6","volume":"118","author":"JL Apfelbaum","year":"2013","unstructured":"Apfelbaum JL, Hagberg CA, Caplan RA, et al. Practice guidelines for management of the difficult airway: an updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Anesthesiology 2013; 118: 251-70.","journal-title":"Anesthesiology"},{"key":"1778_CR9","first-page":"449","volume":"35","author":"KJ Chin","year":"2007","unstructured":"Chin KJ, Arango MF, Paez AF, Turkstra TP. Palatal injury associated with the GlideScope. Anaesth Intensive Care 2007; 35: 449-50.","journal-title":"Anaesth Intensive Care"},{"key":"1778_CR10","doi-asserted-by":"publisher","first-page":"1610","DOI":"10.1213\/01.ane.0000264321.04403.06","volume":"104","author":"AM Malik","year":"2007","unstructured":"Malik AM, Frogel JK. Anterior tonsillar pillar perforation during GlideScope video laryngoscopy. Anesth Analg 2007; 104: 1610-1.","journal-title":"Anesth Analg"},{"key":"1778_CR11","doi-asserted-by":"publisher","first-page":"1609","DOI":"10.1213\/01.ane.0000265490.26332.48","volume":"104","author":"WT Hsu","year":"2007","unstructured":"Hsu WT, Hsu SC, Lee YL, Huang JS, Chen CL. Penetrating injury of the soft palate during GlideScope intubation. Anesth Analg 2007; 104: 1609-10.","journal-title":"Anesth Analg"},{"key":"1778_CR12","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1007\/BF03021900","volume":"54","author":"RM Cooper","year":"2007","unstructured":"Cooper RM. Complications associated with the use of the GlideScope videolaryngoscope. Can J Anesth 2007; 54: 54-7.","journal-title":"Can J Anesth"},{"key":"1778_CR13","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1007\/s12630-012-9824-3","volume":"10","author":"AW Amundson","year":"2013","unstructured":"Amundson AW, Weingarten TN. Traumatic GlideScope(\u00ae) video laryngoscopy resulting in perforation of the soft palate. Can J Anesth 2013; 10: 210-1.","journal-title":"Can J Anesth"},{"key":"1778_CR14","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1111\/coa.12266","volume":"39","author":"J Raja","year":"2014","unstructured":"Raja J, Clyne S, Levine J, Tebbit C, Mair E. Otorhinolaryngology management of seven patients with iatrogenic penetrating injuries from GlideScope\u00ae: our experience. Clin Otolaryngol 2014; 39: 251-4.","journal-title":"Clin Otolaryngol"},{"key":"1778_CR15","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1016\/j.jclinane.2016.08.011","volume":"35","author":"JP Allencherril","year":"2016","unstructured":"Allencherril JP, Joseph L. Soft palate trauma induced during GlideScope intubation. J Clin Anesth 2016; 35: 278-80.","journal-title":"J Clin Anesth"},{"key":"1778_CR16","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1111\/j.1365-2044.2005.04164.x","volume":"60","author":"DJ Doyle","year":"2005","unstructured":"Doyle DJ. The GlideScope video laryngoscope. Anaesthesia 2005; 60: 414-5.","journal-title":"Anaesthesia"},{"key":"1778_CR17","doi-asserted-by":"publisher","first-page":"1050","DOI":"10.1111\/j.1399-6576.2010.02285.x","volume":"54","author":"P Niforopoulou","year":"2010","unstructured":"Niforopoulou P, Pantazopoulos I, Demestiha T, Koudouna E, Xanthos T. Video-laryngoscopes in the adult airway management: a topical review of the literature. Acta Anaesthesiol Scand 2010; 54: 1050-61.","journal-title":"Acta Anaesthesiol Scand"},{"key":"1778_CR18","first-page":"342","volume":"81","author":"FE Agr\u00f2","year":"2015","unstructured":"Agr\u00f2 FE, Doyle DJ, Vennari M. Use of GlideScope\u00ae in adults: an overview. Minerva Anestesiol 2015; 81: 342-51.","journal-title":"Minerva Anestesiol"},{"key":"1778_CR19","doi-asserted-by":"publisher","first-page":"891","DOI":"10.1007\/BF03026792","volume":"54","author":"TP Turkstra","year":"2007","unstructured":"Turkstra TP, Harle CC, Armstrong KP, et al. The GlideScope-specific rigid stylet and standard malleable stylet are equally effective for GlideScope use. Can J Anesth 2007; 54: 891-6.","journal-title":"Can J Anesth"},{"key":"1778_CR20","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1007\/s12630-010-9440-z","volume":"58","author":"PM Jones","year":"2011","unstructured":"Jones PM, Loh FL, Youssef HN, Turkstra TP. A randomized comparison of the GlideRite\u00ae Rigid Stylet to a malleable stylet for orotracheal intubation by novices using the GlideScope\u00ae. Can J Anesth 2011; 58: 256-61.","journal-title":"Can J Anesth"},{"key":"1778_CR21","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1007\/BF03021895","volume":"54","author":"PM Jones","year":"2007","unstructured":"Jones PM, Turkstra TP, Armstrong KP, et al. Effect of stylet angulation and endotracheal tube camber on time to intubation with the GlideScope. Can J Anesth 2007; 54: 21-7.","journal-title":"Can J Anesth"},{"key":"1778_CR22","doi-asserted-by":"publisher","first-page":"352","DOI":"10.1016\/j.jclinane.2009.10.008","volume":"22","author":"M Dupanovi\u0107","year":"2010","unstructured":"Dupanovi\u0107 M, Isaacson SA, Borovcanin Z, et al. Clinical comparison of two stylet angles for orotracheal intubation with the GlideScope video laryngoscope. J Clin Anesth 2010; 22: 352-9.","journal-title":"J Clin Anesth"},{"key":"1778_CR23","doi-asserted-by":"publisher","first-page":"928","DOI":"10.1007\/s12630-016-0654-6","volume":"63","author":"Y Gu","year":"2016","unstructured":"Gu Y, Robert J, Kovacs G, et al. A deliberately restricted laryngeal view with the GlideScope\u00ae video laryngoscope is associated with faster and easier tracheal intubation when compared with a full glottic view: a randomized clinical trial. Can J Anesth 2016; 63: 928-37.","journal-title":"Can J Anesth"},{"key":"1778_CR24","doi-asserted-by":"publisher","first-page":"937","DOI":"10.1093\/ije\/dyt270","volume":"43","author":"A Hr\u00f3bjartsson","year":"2014","unstructured":"Hr\u00f3bjartsson A, Thomsen AS, Emanuelsson F, et al. Observer bias in randomized clinical trials with time-to-event outcomes: systematic review of trials with both blinded and non-blinded outcome assessors. Int J Epidemiol 2014; 43: 937-48.","journal-title":"Int J Epidemiol"},{"key":"1778_CR25","doi-asserted-by":"publisher","first-page":"1236","DOI":"10.1136\/bmj.316.7139.1236","volume":"316","author":"TV Perneger","year":"1998","unstructured":"Perneger TV. What\u2019s wrong with Bonferroni adjustments. BMJ 1998; 316: 1236-8.","journal-title":"BMJ"},{"key":"1778_CR26","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1046\/j.1365-2753.2001.00280.x","volume":"7","author":"JD Holden","year":"2001","unstructured":"Holden JD. Hawthorne effects and research into professional practice. J Eval Clin Pract 2001; 7: 65-70.","journal-title":"J Eval Clin Pract"}],"container-title":["Canadian Journal of Anesthesia\/Journal canadien d'anesth\u00e9sie"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12630-020-01778-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12630-020-01778-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12630-020-01778-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,19]],"date-time":"2021-08-19T00:18:33Z","timestamp":1629332313000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12630-020-01778-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,19]]},"references-count":26,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2020,11]]}},"alternative-id":["1778"],"URL":"https:\/\/doi.org\/10.1007\/s12630-020-01778-2","relation":{},"ISSN":["0832-610X","1496-8975"],"issn-type":[{"type":"print","value":"0832-610X"},{"type":"electronic","value":"1496-8975"}],"subject":[],"published":{"date-parts":[[2020,8,19]]},"assertion":[{"value":"4 April 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 May 2020","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 May 2020","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 August 2020","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"None.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Disclosures"}},{"value":"This study was personally funded by the authors. The GlideScopes and endotracheal tubes were provided by the London Health Sciences Centre for routine clinical care.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Funding statement"}},{"value":"This submission was handled by Dr. Hilary P. Grocott, Editor-in-Chief, <i>Canadian Journal of Anesthesia.<\/i>","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Editorial responsibility"}},{"value":"This content has been made available to all.","name":"free","label":"Free to read"}]}}