{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T17:02:24Z","timestamp":1793379744485,"version":"4.5.0"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,10,7]],"date-time":"2020-10-07T00:00:00Z","timestamp":1602028800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,10,7]],"date-time":"2020-10-07T00:00:00Z","timestamp":1602028800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Can J Anesth\/J Can Anesth"],"published-print":{"date-parts":[[2021,1]]},"DOI":"10.1007\/s12630-020-01826-x","type":"journal-article","created":{"date-parts":[[2020,10,7]],"date-time":"2020-10-07T03:41:50Z","timestamp":1602042110000},"page":"24-29","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["The effect of patient positioning on ultrasound landmarking for cricothyrotomy"],"prefix":"10.1007","volume":"68","author":[{"given":"Lauren","family":"Arthurs","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shannon","family":"Erdelyi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0470-8279","authenticated-orcid":false,"given":"Daniel J.","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,10,7]]},"reference":[{"key":"1826_CR1","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1097\/ALN.0b013e31828604c6","volume":"118","author":"JL Apfelbaum","year":"2013","unstructured":"Apfelbaum JL, Hagberg CA, Caplan RA, et al. Practice guidelines for management of the difficult airway: an updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Anesthesiology 2013; 118: 251-70.","journal-title":"Anesthesiology"},{"key":"1826_CR2","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1093\/bja\/aev371","volume":"115","author":"C Frerk","year":"2015","unstructured":"Frerk C, Mitchell VS, McNarry AF, et al. Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults. Br J Anaesth 2015; 115: 827-48.","journal-title":"Br J Anaesth"},{"key":"1826_CR3","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1007\/s12245-008-0030-6","volume":"1","author":"E Wong","year":"2008","unstructured":"Wong E, Ng YY. The difficult airway in the emergency department. Int J Emerg Med 2008; 1: 107-11.","journal-title":"Int J Emerg Med"},{"key":"1826_CR4","doi-asserted-by":"publisher","first-page":"363.e1","DOI":"10.1016\/j.annemergmed.2014.10.036","volume":"65","author":"CA Brown 3rd","year":"2015","unstructured":"Brown CA 3rd, Bair AE, Pallin DJ, Walls RM, NEAR III Investigators. Techniques, success, and adverse events of emergency department adult intubations. Ann Emerg Med 2015; 65: 363-70.e1.","journal-title":"Ann Emerg Med"},{"key":"1826_CR5","doi-asserted-by":"publisher","first-page":"889","DOI":"10.1111\/j.1365-2044.2010.06425.x","volume":"65","author":"DS Elliott","year":"2010","unstructured":"Elliott DS, Baker PA, Scott MR, Birch CW, Thompson JM. Accuracy of surface landmark identification for cannula cricothyroidotomy. Anaesthesia 2010; 65: 889-94.","journal-title":"Anaesthesia"},{"key":"1826_CR6","doi-asserted-by":"publisher","first-page":"908","DOI":"10.1111\/acem.12732","volume":"22","author":"AE Bair","year":"2015","unstructured":"Bair AE, Chima R. The inaccuracy of using landmark techniques for cricothyroid membrane identification: a comparison of three techniques. Acad Emerg Med 2015; 22: 908-14.","journal-title":"Acad Emerg Med"},{"key":"1826_CR7","doi-asserted-by":"publisher","first-page":"1132","DOI":"10.1097\/ALN.0000000000002454","volume":"129","author":"N Siddiqui","year":"2018","unstructured":"Siddiqui N, Yu E, Boulis S, You-Ten KE. Ultrasound is superior to palpation in identifying the cricothyroid membrane in subjects with poorly defined neck landmarks: a randomized clinical trial. Anesthesiology 2018; 129: 1132-9.","journal-title":"Anesthesiology"},{"key":"1826_CR8","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1007\/s10140-003-0286-3","volume":"10","author":"M Sandoval","year":"2004","unstructured":"Sandoval M, Shestak W, St\u00fcrmann K, Hsu C. Optimal patient position for lumbar puncture, measured by ultrasonography. Emerg Radiol 2004; 10: 179-81.","journal-title":"Emerg Radiol"},{"key":"1826_CR9","first-page":"83641","volume":"95","author":"F Adnet","year":"2001","unstructured":"Adnet F, Baillard C, Borron SW, et al. Randomized study comparing the \u201csniffing position\u201d with simple head extension for laryngoscopic view in elective surgery patients. Anesthesiology 2001; 95: 83641.","journal-title":"Anesthesiology"},{"issue":"Suppl 1","key":"1826_CR10","doi-asserted-by":"publisher","first-page":"i39","DOI":"10.1093\/bja\/aew176","volume":"117","author":"MS Kristensen","year":"2016","unstructured":"Kristensen MS, Teoh WH, Rudolph SS. Ultrasonographic identification of the cricothyroid membrane: Best evidence, techniques, and clinical impact. Br J Anaesth 2016; 117(Suppl 1): i39-48.","journal-title":"Br J Anaesth"},{"key":"1826_CR11","volume-title":"Statistical Power Analysis for the Behavioral Sciences","author":"J Cohen","year":"1988","unstructured":"Cohen J. Statistical Power Analysis for the Behavioral Sciences. 2nd ed. Hillsdale, NJ: Lawrence Earlbaum Associates; 1988 .","edition":"2"},{"key":"1826_CR12","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1111\/anae.14445","volume":"74","author":"A Dixit","year":"2019","unstructured":"Dixit A, Ramaswamy KK, Perera S, Sukumar V, Frerk C. Impact of change in head and neck position on ultrasound localisation of the cricothyroid membrane: an observational study. Anaesthesia 2019; 74: 29-32.","journal-title":"Anaesthesia"},{"key":"1826_CR13","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1093\/bja\/aev029","volume":"114","author":"MS Kristensen","year":"2015","unstructured":"Kristensen MS, Teoh WH, Baker PA. Percutaneous emergency airway access; prevention, preparation, technique and training. Br J Anaesth 2015; 114: 357-61.","journal-title":"Br J Anaesth"},{"key":"1826_CR14","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1016\/j.bja.2018.10.003","volume":"122","author":"P Fennessy","year":"2019","unstructured":"Fennessy P, Drew T, Husarova V, Duggan M, McCaul CL. Emergency cricothyroidotomy: an observational study to estimate optimal incision position and length. Br J Anaesth 2019; 122: 263-8.","journal-title":"Br J Anaesth"},{"key":"1826_CR15","doi-asserted-by":"publisher","first-page":"1087","DOI":"10.1007\/s12630-018-1193-0","volume":"65","author":"LV Duggan","year":"2018","unstructured":"Duggan LV, Brindley PG, Law JA. Improving communication, teamwork, and action during a \u201ccannot intubate cannot oxygenate (CICO)\u201d emergency: employing CICO as a cognitive aid mnemonic. Can J Anesth 2018; 65: 1087-92.","journal-title":"Can J Anesth"}],"container-title":["Canadian Journal of Anesthesia\/Journal canadien d'anesth\u00e9sie"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12630-020-01826-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12630-020-01826-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12630-020-01826-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,7]],"date-time":"2021-10-07T03:26:57Z","timestamp":1633577217000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12630-020-01826-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,7]]},"references-count":15,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,1]]}},"alternative-id":["1826"],"URL":"https:\/\/doi.org\/10.1007\/s12630-020-01826-x","relation":{},"ISSN":["0832-610X","1496-8975"],"issn-type":[{"value":"0832-610X","type":"print"},{"value":"1496-8975","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,10,7]]},"assertion":[{"value":"20 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 June 2020","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 July 2020","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 October 2020","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This content has been made available to all.","name":"free","label":"Free to read"}]}}