{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T15:05:26Z","timestamp":1789657526476,"version":"4.0.1"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Can J Anesth\/J Can Anesth"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1007\/s12630-026-03175-7","type":"journal-article","created":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T22:47:17Z","timestamp":1788302837000},"page":"731-737","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Pearls and pitfalls of noninvasive continuous arterial blood pressure monitoring","Perles et pi\u00e8ges de la surveillance continue noninvasive de la pression art\u00e9rielle"],"prefix":"10.1007","volume":"73","author":[{"given":"Tahir","family":"El Meskine","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-S\u00e9bastien","family":"Lebon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0634-6291","authenticated-orcid":false,"given":"Andr\u00e9","family":"Denault","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,2]]},"reference":[{"key":"3175_CR1","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1177\/00033197211052127","volume":"73","author":"CD Annicchino Baptistella","year":"2022","unstructured":"Annicchino Baptistella CD, de Almeida Mendes C, Silva MJ, Wolosker N. Retrospective observational single-center study of complications of arterial indwelling catheters for invasive blood pressure in intensive care unit patients. Angiology 2022; 73: 431\u20137. https:\/\/doi.org\/10.1177\/00033197211052127","journal-title":"Angiology"},{"key":"3175_CR2","unstructured":"Pen\u00e1z J. Photoelectric measurement of blood pressure, volume and flow in the finger. 1973. https:\/\/ci.nii.ac.jp\/naid\/10020728022\/"},{"key":"3175_CR3","doi-asserted-by":"publisher","unstructured":"Wesseling KH, Settels JJ, de Wit B. The measurement of continuous finger arterial pressure noninvasively in stationary subjects. In: Schmidt TH, Dembroski TM, Bl\u00fcmchen G (Eds.). Biological and Psychological Factors in Cardiovascular Disease. Berlin: Springer-Verlag; 1986: 355\u201375. https:\/\/doi.org\/10.1007\/978-3-642-71234-0_22","DOI":"10.1007\/978-3-642-71234-0_22"},{"key":"3175_CR4","doi-asserted-by":"publisher","first-page":"281","DOI":"10.4103\/aca.aca_120_20","volume":"24","author":"P Frank","year":"2021","unstructured":"Frank P, Logemann F, Gras C, Palmaers T. Noninvasive continuous arterial pressure monitoring during anesthesia induction in patients undergoing cardiac surgery. Ann Card Anaesth 2021; 24: 281\u20137. https:\/\/doi.org\/10.4103\/aca.aca_120_20","journal-title":"Ann Card Anaesth"},{"key":"3175_CR5","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.1016\/j.chest.2017.10.030","volume":"153","author":"K Lakhal","year":"2018","unstructured":"Lakhal K, Ehrmann S, Bouglain T. Noninvasive BP monitoring in the critically ill: time to abandon the arterial catheter? Chest 2018; 153: 1023\u201339. https:\/\/doi.org\/10.1016\/j.chest.2017.10.030","journal-title":"Chest"},{"key":"3175_CR6","doi-asserted-by":"publisher","first-page":"1495","DOI":"10.1007\/s12630-024-02834-x","volume":"71","author":"U Goncin","year":"2024","unstructured":"Goncin U, Liu KK, Rawlyk B, et al. Comparison of the ClearSight\u2122 finger cuff monitor versus invasive arterial blood pressure measurement in elective cardiac surgery patients: a prospective observational study. Can J Anesth 2024; 71: 1495\u2013504. https:\/\/doi.org\/10.1007\/s12630-024-02834-x","journal-title":"Can J Anesth"},{"key":"3175_CR7","doi-asserted-by":"publisher","first-page":"4498","DOI":"10.3390\/jcm11154498","volume":"11","author":"P Helmer","year":"2022","unstructured":"Helmer P, Helf D, Sammeth M, et al. The use of non-invasive continuous blood pressure measuring (ClearSight\u00ae) during central neuraxial anaesthesia for Caesarean section: a retrospective validation study. J Clin Med 2022; 11: 4498. https:\/\/doi.org\/10.3390\/jcm11154498","journal-title":"J Clin Med"},{"key":"3175_CR8","doi-asserted-by":"publisher","first-page":"325","DOI":"10.5468\/ogs.22063","volume":"65","author":"T Misugi","year":"2022","unstructured":"Misugi T, Juri T, Suehiro K, et al. Non-invasive continuous blood pressure monitoring using the ClearSight system for pregnant women at high risks of post-partum hemorrhage: comparison with invasive blood pressure monitoring during Cesarean section. Obstet Gynecol Sci 2022; 65: 325\u201334. https:\/\/doi.org\/10.5468\/ogs.22063","journal-title":"Obstet Gynecol Sci"},{"key":"3175_CR9","doi-asserted-by":"publisher","DOI":"10.1161\/hyp.0000000000000254","volume":"83","author":"JB Cohen","year":"2026","unstructured":"Cohen JB, Byfield RL, Hardy ST, et al. Cuffless devices for the measurement of blood pressure: a scientific statement from the American Heart Association. Hypertension 2026; 83: e00254. https:\/\/doi.org\/10.1161\/hyp.0000000000000254","journal-title":"Hypertension"},{"key":"3175_CR10","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1186\/s12871-021-01374-x","volume":"21","author":"V Eley","year":"2021","unstructured":"Eley V, Christensen R, Guy L, et al. ClearSight finger cuff versus invasive arterial pressure measurement in patients with body mass index above 45 kg\/m\u00b2. BMC Anesthesiol 2021; 21: 152. https:\/\/link.springer.com\/article\/10.1186\/s12871-021-01374-x","journal-title":"BMC Anesthesiol"},{"key":"3175_CR11","doi-asserted-by":"publisher","first-page":"1782","DOI":"10.1053\/j.jvca.2020.11.011","volume":"35","author":"A Mukai","year":"2021","unstructured":"Mukai A, Suehiro K, Kimura A, et al. Effect of systemic vascular resistance on the reliability of noninvasive hemodynamic monitoring in cardiac surgery. J Cardiothorac Vasc Anesth 2021; 35: 1782\u201391. https:\/\/doi.org\/10.1053\/j.jvca.2020.11.011","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"3175_CR12","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1213\/ane.0000000000001096","volume":"122","author":"G Fuda","year":"2016","unstructured":"Fuda G, Denault A, Deschamps A, et al. Risk factors involved in central-to-radial arterial pressure gradient during cardiac surgery. Anesth Analg 2016; 122: 624\u201332. https:\/\/doi.org\/10.1213\/ane.0000000000001096","journal-title":"Anesth Analg"},{"key":"3175_CR13","doi-asserted-by":"publisher","first-page":"1634","DOI":"10.1007\/s12630-025-03058-3","volume":"72","author":"H Chala","year":"2025","unstructured":"Chala H, Daccache N, Morisson L, Denault A, Laferri\u00e8re-Langlois P. Risk factors for a central-to-peripheral arterial blood pressure gradient in adults: a systematic review. Can J Anesth 2025; 72: 1634\u201349. https:\/\/doi.org\/10.1007\/s12630-025-03058-3","journal-title":"Can J Anesth"},{"key":"3175_CR14","doi-asserted-by":"publisher","unstructured":"Pereira Cezar Zamper R, Abdelaatti A, Tachibana R, et al. Phase-dependent agreement between noninvasive and invasive blood pressure monitoring during transcatheter aortic valve replacement: a prospective observational study. Can J Anesth 2026; https:\/\/doi.org\/10.1007\/s12630-026-03176-6","DOI":"10.1007\/s12630-026-03176-6"}],"container-title":["Canadian Journal of Anesthesia\/Journal canadien d'anesth\u00e9sie"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12630-026-03175-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12630-026-03175-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12630-026-03175-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T14:08:32Z","timestamp":1789654112000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12630-026-03175-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":14,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["3175"],"URL":"https:\/\/doi.org\/10.1007\/s12630-026-03175-7","relation":{},"ISSN":["0832-610X","1496-8975"],"issn-type":[{"value":"0832-610X","type":"print"},{"value":"1496-8975","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"26 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 February 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 March 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 September 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This content has been made available to all.","name":"free","label":"Free to read"}]}}