{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T08:20:16Z","timestamp":1778660416654,"version":"3.51.4"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2014,4,12]],"date-time":"2014-04-12T00:00:00Z","timestamp":1397260800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Cardiovasc Interv and Ther"],"published-print":{"date-parts":[[2015,4]]},"DOI":"10.1007\/s12928-014-0263-7","type":"journal-article","created":{"date-parts":[[2014,4,11]],"date-time":"2014-04-11T20:43:29Z","timestamp":1397249009000},"page":"147-150","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Stent intussusception after thromboaspiration through a platinum chrome stent: a particular case of longitudinal stent deformation"],"prefix":"10.1007","volume":"30","author":[{"given":"Rafael","family":"Mila","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gustavo","family":"Vignolo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pedro","family":"Trujillo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2014,4,12]]},"reference":[{"issue":"1","key":"263_CR1","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1002\/(SICI)1522-726X(200005)50:1<120::AID-CCD26>3.0.CO;2-T","volume":"50","author":"JA Ormiston","year":"2000","unstructured":"Ormiston JA, Dixon SR, Webster MW, Ruygrok PN, Stewart JT, Minchington I, et al. Stent longitudinal flexibility: a comparison of 13 stent designs before and after balloon expansion. Catheter Cardiovasc Interv. 2000;50(1):120\u20134.","journal-title":"Catheter Cardiovasc Interv."},{"issue":"12","key":"263_CR2","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1016\/j.jcin.2011.11.002","volume":"4","author":"JA Ormiston","year":"2011","unstructured":"Ormiston JA, Webber B, Webster MW. Stent longitudinal integrity bench insights into a clinical problem. JACC Cardiovasc Interv. 2011;4(12):1310\u20137.","journal-title":"JACC Cardiovasc Interv."},{"issue":"2","key":"263_CR3","doi-asserted-by":"crossref","first-page":"256","DOI":"10.4244\/EIJV7I2A41","volume":"7","author":"M Pitney","year":"2011","unstructured":"Pitney M, Pitney K, Jepson N, Friedman D, Nguyen-Dang T, Matthews J, et al. Major stent deformation\/pseudofracture of 7 Crown Endeavor\/Micro Driver stent platform: incidence and causative factors. EuroIntervention. 2011;7(2):256\u201362.","journal-title":"EuroIntervention"},{"issue":"7","key":"263_CR4","doi-asserted-by":"crossref","first-page":"872","DOI":"10.4244\/EIJV7I7A135","volume":"7","author":"CG Hanratty","year":"2011","unstructured":"Hanratty CG, Walsh SJ. Longitudinal compression: a \u201cnew\u201d complication with modern coronary stent platforms\u2013\u2013time to think beyond deliverability? EuroIntervention. 2011;7(7):872\u20137.","journal-title":"EuroIntervention"},{"issue":"2","key":"263_CR5","doi-asserted-by":"crossref","first-page":"267","DOI":"10.4244\/EIJV8I2A41","volume":"8","author":"PD Williams","year":"2012","unstructured":"Williams PD, Mamas MA, Morgan KP, El-Omar M, Clarke B, Bainbridge A, et al. Longitudinal stent deformation: a retrospective analysis of frequency and mechanisms. EuroIntervention. 2012;8(2):267\u201374.","journal-title":"EuroIntervention"},{"issue":"5","key":"263_CR6","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1586\/erd.12.44","volume":"9","author":"PD Williams","year":"2012","unstructured":"Williams PD, Mamas MA, Fraser DG. How serious an adverse event is longitudinal stent deformation? Incidence and severity. Expert Rev Med Devices. 2012;9(5):449\u201351.","journal-title":"Expert Rev Med Devices."},{"issue":"2","key":"263_CR7","doi-asserted-by":"crossref","first-page":"196","DOI":"10.4244\/EIJV8I2A33","volume":"8","author":"MA Mamas","year":"2012","unstructured":"Mamas MA, Williams PD. Longitudinal stent deformation: insights on mechanisms, treatments and outcomes from the food and drug administration manufacturer and user facility device experience database. EuroIntervention. 2012;8(2):196\u2013204.","journal-title":"EuroIntervention"},{"issue":"3","key":"263_CR8","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1016\/j.ijcard.2012.09.143","volume":"164","author":"N Foin","year":"2013","unstructured":"Foin N, Di Mario C, Francis DP, Davies JE. Stent flexibility versus concertina effect: mechanism of an unpleasant trade-off in stent design and its implications for stent selection in the cath-lab. Int J Cardiol. 2013;164(3):259\u201361.","journal-title":"Int J Cardiol."},{"issue":"5","key":"263_CR9","doi-asserted-by":"crossref","first-page":"630","DOI":"10.4244\/EIJV6I5A105","volume":"6","author":"NV Soucy","year":"2010","unstructured":"Soucy NV, Feygin JM, Tunstall R, Casey MA, Pennington DE, Huibregtse BA, et al. Strut tissue coverage and endothelial cell coverage: a comparison between bare metal stent platforms and platinum chromium stents with and without everolimus-eluting coating. EuroIntervention. 2010;6(5):630\u20137.","journal-title":"EuroIntervention"},{"issue":"3","key":"263_CR10","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1007\/s12325-010-0022-9","volume":"27","author":"IB Menown","year":"2010","unstructured":"Menown IB, Noad R, Garcia EJ, Meredith I. The platinum chromium element stent platform: from alloy, to design, to clinical practice. Adv Ther. 2010;27(3):129\u201341.","journal-title":"Adv Ther."},{"issue":"5","key":"263_CR11","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1016\/j.ihj.2012.07.012","volume":"64","author":"E Janakiraman","year":"2012","unstructured":"Janakiraman E, Subban V, Victor SM, Mullasari AS. Longitudinal deformation\u2013\u2013price we pay for better deliverability of coronary stent platforms. Indian Heart J. 2012;64(5):518\u201320.","journal-title":"Indian Heart J."},{"issue":"8","key":"263_CR12","doi-asserted-by":"crossref","first-page":"990","DOI":"10.4244\/EIJV8I8A150","volume":"8","author":"A Aminian","year":"2012","unstructured":"Aminian A, Lalmand J. Comments on \u201cLongitudinal stent deformation: insights on mechanisms, treatments and outcomes from the FDA manufacturer and user facility device experience database\u201d by Mamas et al. EuroIntervention. 2012;8(8):990\u20131 (author reply 2\u20133).","journal-title":"EuroIntervention"},{"issue":"5","key":"263_CR13","doi-asserted-by":"crossref","first-page":"E206","DOI":"10.1002\/ccd.24472","volume":"81","author":"G Leibundgut","year":"2013","unstructured":"Leibundgut G, Gick M, Toma A, Valina C, Loffelhardt N, Joachim Buttner H, et al. Longitudinal compression of the platinum-chromium everolimus-eluting stent during coronary implantation: predisposing mechanical properties, incidence, and predictors in a large patient cohort. Catheter Cardiovasc Interv. 2013;81(5):E206\u201314.","journal-title":"Catheter Cardiovasc Interv."},{"issue":"2","key":"263_CR14","doi-asserted-by":"crossref","first-page":"187","DOI":"10.4244\/EIJV8I2A32","volume":"8","author":"DJ Kereiakes","year":"2012","unstructured":"Kereiakes DJ, Popma JJ, Cannon LA, Kandzari DE, Kimmelstiel CD, Meredith IT, et al. Longitudinal stent deformation: quantitative coronary angiographic analysis from the PERSEUS and PLATINUM randomised controlled clinical trials. EuroIntervention. 2012;8(2):187\u201395.","journal-title":"EuroIntervention"},{"key":"263_CR15","doi-asserted-by":"crossref","unstructured":"Ormiston JA, Webber B, Ubod B, White J, Webster MW. Stent longitudinal strength assessed using point compression: insights from a second-generation, clinically related bench test. Circ Cardiovasc Interv. 2014;7:62\u201369.","DOI":"10.1161\/CIRCINTERVENTIONS.113.000621"}],"container-title":["Cardiovascular Intervention and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12928-014-0263-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s12928-014-0263-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12928-014-0263-7","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,2]],"date-time":"2019-06-02T14:25:33Z","timestamp":1559485533000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s12928-014-0263-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,4,12]]},"references-count":15,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2015,4]]}},"alternative-id":["263"],"URL":"https:\/\/doi.org\/10.1007\/s12928-014-0263-7","relation":{},"ISSN":["1868-4300","1868-4297"],"issn-type":[{"value":"1868-4300","type":"print"},{"value":"1868-4297","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,4,12]]}}}