{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T01:36:18Z","timestamp":1767922578548,"version":"3.49.0"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2016,6,9]],"date-time":"2016-06-09T00:00:00Z","timestamp":1465430400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Cardiovasc Interv and Ther"],"published-print":{"date-parts":[[2017,7]]},"DOI":"10.1007\/s12928-016-0402-4","type":"journal-article","created":{"date-parts":[[2016,6,9]],"date-time":"2016-06-09T09:29:09Z","timestamp":1465464549000},"page":"254-258","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Novel \u201cbaby-in-mother\u201d technique with the GuideLiner in the bifurcation coronary intervention with the protect-wire kept in the side branch"],"prefix":"10.1007","volume":"32","author":[{"given":"Takayuki","family":"Warisawa","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hisaaki","family":"Ishiguro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akihiro","family":"Nakajima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sunao","family":"Nakamura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2016,6,9]]},"reference":[{"key":"402_CR1","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1002\/ccd.20223","volume":"63","author":"S Takahashi","year":"2004","unstructured":"Takahashi S, Saito S, Takanak S, Miyashita Y, Shiono T, Arai F, et al. New method to increase a back-up support of a 6 French guiding coronary catheter. Catheter Cardiovasc Interv. 2004;63:452\u20136.","journal-title":"Catheter Cardiovasc Interv"},{"key":"402_CR2","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1002\/ccd.21395","volume":"71","author":"MA Mamas","year":"2008","unstructured":"Mamas MA, Fath-Ordoubadi F, Fraser D. Successful use of the Heartrail II catheter as a stent delivery catheter following failure of conventional techniques. Catheter Cardiovasc Interv. 2008;71:358\u201363.","journal-title":"Catheter Cardiovasc Interv"},{"issue":"265\u2013271","key":"402_CR3","first-page":"17","volume":"5","author":"MA Mamas","year":"2009","unstructured":"Mamas MA, Eichh\u00f6fer J, Hendry C, El-Omar M, Clarke B, Neyses L, et al. Use of the Heartrail II catheter as a distal stent delivery device; an extended case series. Eurointervention. 2009;5(265\u2013271):17.","journal-title":"Eurointervention"},{"key":"402_CR4","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1002\/ccd.22458","volume":"76","author":"MA Mamas","year":"2010","unstructured":"Mamas MA, Fath-Ordoubadi F, Fraser DG. Distal stent delivery with GuideLiner catheter: first in man experience. Catheter Cardiovasc Interv. 2010;76:102\u201311.","journal-title":"Catheter Cardiovasc Interv"},{"key":"402_CR5","doi-asserted-by":"crossref","first-page":"277","DOI":"10.4244\/EIJV6I2A44","volume":"6","author":"U Rao","year":"2010","unstructured":"Rao U, Gorog D, Syzgula J, Kumar S, Stone C, Kukreja N. The GuideLiner \u201cchild\u201d catheter. Eurointervention. 2010;6:277\u20139.","journal-title":"Eurointervention."},{"key":"402_CR6","doi-asserted-by":"crossref","first-page":"336","DOI":"10.4244\/EIJV8I3A52","volume":"8","author":"FH Man de","year":"2012","unstructured":"de Man FH, Tandjung K, Hartmann M, van Houwelingen KG, Stoel MG, Louwerenburg HW, et al. Usefulness and safety of the GuideLiner catheter to enhance intubation and support of guide catheters: insights from the Twente GuideLiner registry. Eurointervention. 2012;8:336\u201344.","journal-title":"Eurointervention."},{"key":"402_CR7","doi-asserted-by":"crossref","first-page":"325","DOI":"10.4244\/EIJY14M06_02","volume":"11","author":"PH Chan","year":"2015","unstructured":"Chan PH, Alegria-Barrero E, Foin N, Paulo M, Lindsay AC, Viceconte N, et al. Extended use of the GuideLiner in complex coronary interventions. Eurointervention. 2015;11:325\u201335.","journal-title":"Eurointervention."},{"key":"402_CR8","first-page":"E169","volume":"27","author":"TI Repanas","year":"2015","unstructured":"Repanas TI, Christopoulos G, Brilakis ES. \u201cCandy Cane\u201d guide catheter extension for stent delivery. J Invasive Cardiol. 2015;27:E169\u201370.","journal-title":"J Invasive Cardiol."},{"key":"402_CR9","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.ijcard.2015.03.084","volume":"185","author":"S Garc\u00eda-Blas","year":"2015","unstructured":"Garc\u00eda-Blas S, Valero E, Escribano D, Bonanad C, Sanchis J, N\u00fa\u00f1ez J. GuideLiner use for the percutaneous treatment of right coronary artery arising from the left circumflex (L-type single coronary artery). Int J Cardiol. 2015;185:2\u20133.","journal-title":"Int J Cardiol"},{"key":"402_CR10","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.26329","author":"TM Waterbury","year":"2015","unstructured":"Waterbury TM, Sorajja P, Bell MR, Lennon RJ, Mathew V, Singh M, et al. Experience and complications associated with use of guide extension catheters in percutaneous coronary intervention. Catheter Cardiovasc Interv. 2015. doi:\n                        10.1002\/ccd.26329\n                        \n                    .","journal-title":"Catheter Cardiovasc Interv."},{"key":"402_CR11","first-page":"E42","volume":"4","author":"T Bhat","year":"2014","unstructured":"Bhat T, Baydoun H, Tamburino F. A unique complication with use of the GuideLiner catheter in percutaneous coronary interventions and its successful management. J Invasive Cardiol. 2014;4:E42\u20134.","journal-title":"J Invasive Cardiol."},{"key":"402_CR12","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1016\/j.ijcard.2015.08.034","volume":"201","author":"KL Yew","year":"2015","unstructured":"Yew KL, Kang Z. Guidezilla guide extension catheter facilitated the delivery of long and bulky In.Pact Falcon drug-coated balloon for the treatment of chronic total occlusion lesion. Int J Cardiol. 2015;201:220\u20131. doi:\n                        10.1016\/j.ijcard.2015.08.034\n                        \n                    .","journal-title":"Int J Cardiol"}],"container-title":["Cardiovascular Intervention and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s12928-016-0402-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12928-016-0402-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12928-016-0402-4","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12928-016-0402-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,6,26]],"date-time":"2017-06-26T21:55:45Z","timestamp":1498514145000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s12928-016-0402-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,6,9]]},"references-count":12,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017,7]]}},"alternative-id":["402"],"URL":"https:\/\/doi.org\/10.1007\/s12928-016-0402-4","relation":{},"ISSN":["1868-4300","1868-4297"],"issn-type":[{"value":"1868-4300","type":"print"},{"value":"1868-4297","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,6,9]]}}}