{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T14:27:47Z","timestamp":1776695267939,"version":"3.51.2"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2016,5,25]],"date-time":"2016-05-25T00:00:00Z","timestamp":1464134400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Cardiovasc Interv and Ther"],"published-print":{"date-parts":[[2017,7]]},"DOI":"10.1007\/s12928-016-0403-3","type":"journal-article","created":{"date-parts":[[2016,5,25]],"date-time":"2016-05-25T11:07:39Z","timestamp":1464174459000},"page":"199-205","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Impact of stent platform on longitudinal stent deformation: an in vivo frequency domain optical coherence tomography study"],"prefix":"10.1007","volume":"32","author":[{"given":"Ryotaro","family":"Yamada","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroyuki","family":"Okura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Teruyoshi","family":"Kume","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenzo","family":"Fukuhara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Terumasa","family":"Koyama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomitaka","family":"Higa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoji","family":"Neishi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kiyoshi","family":"Yoshida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shiro","family":"Uemura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2016,5,25]]},"reference":[{"issue":"9710","key":"403_CR1","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/S0140-6736(09)62127-9","volume":"375","author":"E Kedhi","year":"2010","unstructured":"Kedhi E, Joesoef KS, McFadden E, Wassing J, van Mieghem C, Goedhart D, et al. Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice (COMPARE): a randomised trial. Lancet. 2010;375(9710):201\u20139.","journal-title":"Lancet"},{"issue":"18","key":"403_CR2","doi-asserted-by":"crossref","first-page":"1663","DOI":"10.1056\/NEJMoa0910496","volume":"362","author":"GW Stone","year":"2010","unstructured":"Stone GW, Rizvi A, Newman W, Mastali K, Wang JC, Caputo R, et al. Everolimus-eluting versus paclitaxel-eluting stents in coronary artery disease. N Engl J Med. 2010;362(18):1663\u201374.","journal-title":"N Engl J Med"},{"issue":"21","key":"403_CR3","doi-asserted-by":"crossref","first-page":"2143","DOI":"10.1016\/j.jacc.2011.01.023","volume":"57","author":"L Raber","year":"2011","unstructured":"Raber L, Juni P, Nuesch E, Kalesan B, Wenaweser P, Moschovitis A, et al. Long-term comparison of everolimus-eluting and sirolimus-eluting stents for coronary revascularization. J Am Coll Cardiol. 2011;57(21):2143\u201351.","journal-title":"J Am Coll Cardiol"},{"issue":"10","key":"403_CR4","doi-asserted-by":"crossref","first-page":"1225","DOI":"10.1161\/CIRCULATIONAHA.112.104059","volume":"126","author":"T Kimura","year":"2012","unstructured":"Kimura T, Morimoto T, Natsuaki M, Shiomi H, Igarashi K, Kadota K, et al. Comparison of everolimus-eluting and sirolimus-eluting coronary stents: 1-year outcomes from the Randomized Evaluation of Sirolimus-eluting Versus Everolimus-eluting stent Trial (RESET). Circulation. 2012;126(10):1225\u201336.","journal-title":"Circulation"},{"issue":"16","key":"403_CR5","doi-asserted-by":"crossref","first-page":"1700","DOI":"10.1016\/j.jacc.2011.02.016","volume":"57","author":"GW Stone","year":"2011","unstructured":"Stone GW, Teirstein PS, Meredith IT, Farah B, Dubois CL, Feldman RL, et al. A prospective, randomized evaluation of a novel everolimus-eluting coronary stent: the PLATINUM (a Prospective, Randomized, Multicenter Trial to Assess an Everolimus-Eluting Coronary Stent System [PROMUS Element] for the Treatment of Up to Two de Novo Coronary Artery Lesions) trial. J Am Coll Cardiol. 2011;57(16):1700\u20138.","journal-title":"J Am Coll Cardiol"},{"issue":"1","key":"403_CR6","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1002\/(SICI)1522-726X(200005)50:1<120::AID-CCD26>3.0.CO;2-T","volume":"50","author":"JA Ormiston","year":"2000","unstructured":"Ormiston JA, Dixon SR, Webster MW, Ruygrok PN, Stewart JT, Minchington I, et al. Stent longitudinal flexibility: a comparison of 13 stent designs before and after balloon expansion. Catheter Cardiovasc Interv. 2000;50(1):120\u20134.","journal-title":"Catheter Cardiovasc Interv"},{"issue":"2","key":"403_CR7","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/j.carrev.2008.08.002","volume":"10","author":"T Tsunoda","year":"2009","unstructured":"Tsunoda T, Hara H, Nakajima K, Shinji H, Ito S, Iijima R, et al. Stent deformation: an experimental study of coronary ostial stenting. Cardiovasc Revasc Med. 2009;10(2):80\u20137.","journal-title":"Cardiovasc Revasc Med."},{"issue":"12","key":"403_CR8","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1016\/j.jcin.2011.11.002","volume":"4","author":"JA Ormiston","year":"2011","unstructured":"Ormiston JA, Webber B, Webster MW. Stent longitudinal integrity bench insights into a clinical problem. JACC Cardiovasc Interv. 2011;4(12):1310\u20137.","journal-title":"JACC Cardiovasc Interv."},{"issue":"6","key":"403_CR9","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1111\/j.1540-8183.2012.00765.x","volume":"25","author":"M Abdel-Wahab","year":"2012","unstructured":"Abdel-Wahab M, Sulimov DS, Kassner G, Geist V, Toelg R, Richardt G. Longitudinal deformation of contemporary coronary stents: an integrated analysis of clinical experience and observations from the bench. J Interv Cardiol. 2012;25(6):576\u201385.","journal-title":"J Interv Cardiol."},{"issue":"12","key":"403_CR10","doi-asserted-by":"crossref","first-page":"e39","DOI":"10.1016\/j.jcin.2012.08.015","volume":"5","author":"J Foerst","year":"2012","unstructured":"Foerst J, Foin N, Hettleman B. Longitudinal stent compression demonstrated by angiographic \u201cwedding band\u201d and 3-dimensional optical coherence tomography. JACC Cardiovasc Interv. 2012;5(12):e39\u201340.","journal-title":"JACC Cardiovasc Interv."},{"issue":"2","key":"403_CR11","doi-asserted-by":"crossref","first-page":"187","DOI":"10.4244\/EIJV8I2A32","volume":"8","author":"DJ Kereiakes","year":"2012","unstructured":"Kereiakes DJ, Popma JJ, Cannon LA, Kandzari DE, Kimmelstiel CD, Meredith IT, et al. Longitudinal stent deformation: quantitative coronary angiographic analysis from the PERSEUS and PLATINUM randomised controlled clinical trials. EuroIntervention. 2012;8(2):187\u201395.","journal-title":"EuroIntervention."},{"issue":"7","key":"403_CR12","first-page":"311","volume":"26","author":"A Lupi","year":"2014","unstructured":"Lupi A, Porto I, Rognoni A, Lazzero M, Fattori R, Parisi R, et al. Clinical and biomechanical behavior of a platinum-chromium stent platform in a large all-comer single-center population: insights from the Novara-PROMETEUS registry. J Invasive Cardiol. 2014;26(7):311\u20137.","journal-title":"J Invasive Cardiol."},{"issue":"2","key":"403_CR13","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/j.ijcard.2014.05.015","volume":"175","author":"H Ota","year":"2014","unstructured":"Ota H, Kitabata H, Magalhaes MA, Bui A, Kardenas K, Thomas CH, et al. Comparison of frequency and severity of longitudinal stent deformation among various drug-eluting stents: an intravascular ultrasound study. Int J Cardiol. 2014;175(2):261\u20137.","journal-title":"Int J Cardiol"},{"issue":"1","key":"403_CR14","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1161\/CIRCINTERVENTIONS.113.000621","volume":"7","author":"JA Ormiston","year":"2014","unstructured":"Ormiston JA, Webber B, Ubod B, White J, Webster MW. Stent longitudinal strength assessed using point compression: insights from a second-generation, clinically related bench test. Circ Cardiovasc Interv. 2014;7(1):62\u20139.","journal-title":"Circ Cardiovasc Interv."},{"issue":"9","key":"403_CR15","doi-asserted-by":"crossref","first-page":"2209","DOI":"10.1253\/circj.CJ-14-0108","volume":"78","author":"Y Kobayashi","year":"2014","unstructured":"Kobayashi Y, Okura H, Kume T, Yamada R, Kobayashi Y, Fukuhara K, et al. Impact of target lesion coronary calcification on stent expansion. Circ J. 2014;78(9):2209\u201314.","journal-title":"Circ J"},{"issue":"8","key":"403_CR16","doi-asserted-by":"crossref","first-page":"1106","DOI":"10.1016\/j.amjcard.2012.05.047","volume":"110","author":"S Fedele","year":"2012","unstructured":"Fedele S, Biondi-Zoccai G, Kwiatkowski P, Di Vito L, Occhipinti M, Cremonesi A, et al. Reproducibility of coronary optical coherence tomography for lumen and length measurements in humans (The CLI-VAR [Centro per la Lotta contro l\u2019Infarto-VARiability] study). Am J Cardiol. 2012;110(8):1106\u201312.","journal-title":"Am J Cardiol"},{"issue":"2","key":"403_CR17","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1007\/s10554-013-0330-7","volume":"30","author":"Y Liu","year":"2014","unstructured":"Liu Y, Shimamura K, Kubo T, Tanaka A, Kitabata H, Ino Y, et al. Comparison of longitudinal geometric measurement in human coronary arteries between frequency-domain optical coherence tomography and intravascular ultrasound. Int J Cardiovasc Imaging. 2014;30(2):271\u20137.","journal-title":"Int J Cardiovasc Imaging"},{"issue":"3","key":"403_CR18","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1253\/circj.CJ-11-0845","volume":"76","author":"T Kume","year":"2012","unstructured":"Kume T, Okura H, Miyamoto Y, Yamada R, Saito K, Tamada T, et al. Natural history of stent edge dissection, tissue protrusion and incomplete stent apposition detectable only on optical coherence tomography after stent implantation\u2014preliminary observation. Circ J. 2012;76(3):698\u2013703.","journal-title":"Circ J"},{"issue":"3","key":"403_CR19","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1002\/ccd.20950","volume":"69","author":"J Aoki","year":"2007","unstructured":"Aoki J, Nakazawa G, Tanabe K, Hoye A, Yamamoto H, Nakayama T, et al. Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation. Catheter Cardiovasc Interv. 2007;69(3):380\u20136.","journal-title":"Catheter Cardiovasc Interv"},{"issue":"21","key":"403_CR20","doi-asserted-by":"crossref","first-page":"2382","DOI":"10.1161\/CIRCULATIONAHA.110.003459","volume":"123","author":"M Imai","year":"2011","unstructured":"Imai M, Kadota K, Goto T, Fujii S, Yamamoto H, Fuku Y, et al. Incidence, risk factors, and clinical sequelae of angiographic peri-stent contrast staining after sirolimus-eluting stent implantation. Circulation. 2011;123(21):2382\u201391.","journal-title":"Circulation"},{"issue":"4","key":"403_CR21","first-page":"182","volume":"25","author":"JM Torre Hernandez De la","year":"2013","unstructured":"De la Torre Hernandez JM, Garcia Camarero T, Lerena P, Lee DH, Sainz Laso F, Gorria GM, et al. A real all-comers randomized trial comparing Xience Prime and Promus Element stents. J Invasive Cardiol. 2013;25(4):182\u20135.","journal-title":"J Invasive Cardiol."},{"issue":"1","key":"403_CR22","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.ijcard.2011.12.057","volume":"167","author":"G Sarno","year":"2013","unstructured":"Sarno G, Lagerqvist B, Carlsson J, Olivecrona G, Nilsson J, Calais F, et al. Initial clinical experience with an everolimus eluting platinum chromium stent (Promus Element) in unselected patients from the Swedish Coronary Angiography and Angioplasty Registry (SCAAR). Int J Cardiol. 2013;167(1):146\u201350.","journal-title":"Int J Cardiol"},{"issue":"11","key":"403_CR23","doi-asserted-by":"crossref","first-page":"1301","DOI":"10.4244\/EIJV9I11A220","volume":"9","author":"S Inaba","year":"2014","unstructured":"Inaba S, Mintz GS, Yun KH, Yakushiji T, Shimizu T, Kang SJ, et al. Mechanical complications of everolimus-eluting stents associated with adverse events: an intravascular ultrasound study. EuroIntervention. 2014;9(11):1301\u20138.","journal-title":"EuroIntervention."}],"container-title":["Cardiovascular Intervention and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s12928-016-0403-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12928-016-0403-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12928-016-0403-3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12928-016-0403-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,2]],"date-time":"2019-06-02T14:25:36Z","timestamp":1559485536000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s12928-016-0403-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,5,25]]},"references-count":23,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017,7]]}},"alternative-id":["403"],"URL":"https:\/\/doi.org\/10.1007\/s12928-016-0403-3","relation":{},"ISSN":["1868-4300","1868-4297"],"issn-type":[{"value":"1868-4300","type":"print"},{"value":"1868-4297","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,5,25]]}}}