{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T20:51:08Z","timestamp":1793998268780,"version":"4.8.0"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2016,7,22]],"date-time":"2016-07-22T00:00:00Z","timestamp":1469145600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Cardiovasc Interv and Ther"],"published-print":{"date-parts":[[2017,7]]},"DOI":"10.1007\/s12928-016-0407-z","type":"journal-article","created":{"date-parts":[[2016,7,22]],"date-time":"2016-07-22T11:42:52Z","timestamp":1469187772000},"page":"225-232","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Prospective multi-center registry to evaluate efficacy and safety of the newly developed diamond-like carbon-coated cobalt\u2013chromium coronary stent system"],"prefix":"10.1007","volume":"32","author":[{"given":"Kenji","family":"Ando","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katsuhisa","family":"Ishii","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eiji","family":"Tada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuaki","family":"Kataoka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Atsushi","family":"Hirohata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenji","family":"Goto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katsuyuki","family":"Kobayashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Tsutsui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Makoto","family":"Nakahama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hitoshi","family":"Nakashima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shinichiroh","family":"Uchikawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junji","family":"Kanda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Satoshi","family":"Yasuda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junji","family":"Yajima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Kitabayashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shumpei","family":"Sakurai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keita","family":"Nakanishi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naoto","family":"Inoue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hirofumi","family":"Noike","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Terumitsu","family":"Hasebe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tetsuya","family":"Sato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masao","family":"Yamasaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takeshi","family":"Kimura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2016,7,22]]},"reference":[{"issue":"3","key":"407_CR1","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1016\/S0735-1097(88)80046-9","volume":"12","author":"M Nobuyoshi","year":"1988","unstructured":"Nobuyoshi M, Kimura T, Nosaka H, Mioka S, Ueno K, Yokoi H, et al. Restenosis after successful percutaneous transluminal coronary angioplasty: serial angiographic follow-up of 229 patients. J Am Coll Cardiol. 1988;12(3):616\u201323.","journal-title":"J Am Coll Cardiol"},{"key":"407_CR2","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1056\/NEJM199408253310802","volume":"331","author":"DL Fischman","year":"1994","unstructured":"Fischman DL, Leon MB, Baim DS, Schatz RA, Savage MP, Penn I, et al. A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. N Engl J Med. 1994;331:496\u2013501.","journal-title":"N Engl J Med"},{"key":"407_CR3","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1056\/NEJM199408253310801","volume":"331","author":"PW Serruys","year":"1994","unstructured":"Serruys PW, de Jaegere P, Kiemeneij F, Macaya C, Rutsch W, Heyndrickx G, et al. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. N Engl J Med. 1994;331:489\u201395.","journal-title":"N Engl J Med"},{"key":"407_CR4","doi-asserted-by":"crossref","first-page":"2310","DOI":"10.1056\/NEJMoa1009406","volume":"363","author":"C Kaiser","year":"2010","unstructured":"Kaiser C, Galatius S, Erne P, Eberli F, Alber H, Rickli H, et al. Drug-eluting versus bare-metal stents in large coronary arteries. N Engl J Med. 2010;363:2310\u20139.","journal-title":"N Engl J Med"},{"key":"407_CR5","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.1016\/j.jacc.2012.01.008","volume":"59","author":"C Birgelen von","year":"2012","unstructured":"von Birgelen C, Basalus MWZ, Tandjung K, van Houwelingen KG, Stoel MG, Louwerenburg JHW, et al. A randomized controlled trial in second-generation zotarolimus-eluting resolute stents versus everolimus-eluting Xience V stents in real-world patients: the TWENTE trial. J Am Coll Cardiol. 2012;59:1350\u201361.","journal-title":"J Am Coll Cardiol"},{"key":"407_CR6","doi-asserted-by":"crossref","first-page":"S28","DOI":"10.1016\/0003-4975(89)90627-9","volume":"48","author":"VL Gott","year":"1989","unstructured":"Gott VL, Daggett RL, Young WP. Development of a carbon-coated, central-hinging, bileaflet valve. Ann Thorac Surg. 1989;48:S28\u201330.","journal-title":"Ann Thorac Surg"},{"key":"407_CR7","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1016\/S0925-9635(03)00081-5","volume":"12","author":"R Hauert","year":"2003","unstructured":"Hauert R. A review of modified DLC coatings for biological applications. Diam Relat Mater. 2003;12:583\u20139.","journal-title":"Diam Relat Mater"},{"key":"407_CR8","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1016\/S0049-3848(00)00295-4","volume":"99","author":"K Gutensohn","year":"2000","unstructured":"Gutensohn K, Beythien C, Bau J, Fenner T, Grewe P, Koester R, et al. In vitro analyses of diamond-like carbon coated stents: reduction of metal ion release, platelet activation, and thrombogenicity. Thromb Res. 2000;99:577\u201385.","journal-title":"Thromb Res."},{"issue":"1","key":"407_CR9","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1157\/13083641","volume":"59","author":"R Mongrain","year":"2006","unstructured":"Mongrain R, Rod\u00e9s CJ. Role of shear stress in atherosclerosis and restenosis after coronary stent implantation. Rev Esp Cardiol. 2006;59(1):1\u20134.","journal-title":"Rev Esp Cardiol"},{"key":"407_CR10","doi-asserted-by":"crossref","first-page":"2816","DOI":"10.1161\/01.CIR.103.23.2816","volume":"103","author":"A Kastrati","year":"2001","unstructured":"Kastrati A, Mehilli J, Dirschinger J, Dotzer F, Sch\u00fchlen H, Neumann FJ, et al. Intracoronary stenting and angiographic results:strut thickness effect on restenosis outcome (ISAR-STEREO) trial. Circulation. 2001;103:2816\u201321.","journal-title":"Circulation"},{"key":"407_CR11","unstructured":"Summary of Safety and Effectiveness Data Multi-Link VISIONTM RX & OTW Coronary Stent Systems. \n                        http:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf2\/p020047b.pdf\n                        \n                    ."},{"issue":"23","key":"407_CR12","doi-asserted-by":"crossref","first-page":"1773","DOI":"10.1056\/NEJMoa012843","volume":"346","author":"MC Morice","year":"2002","unstructured":"Morice MC, Serruys PW, Sousa JE, Fajadet J, Hayashi EB, Perin M, et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med. 2002;346(23):1773\u201380.","journal-title":"N Engl J Med"},{"key":"407_CR13","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1016\/S0002-9149(03)00669-6","volume":"92","author":"DJ Kereiakes","year":"2003","unstructured":"Kereiakes DJ, Cox DA, Hermiller JB, Midei MG, Bachinsky WB, Nukta ED, et al. Usefulness of a cobalt chromium coronary stent alloy. Am J Cardiol. 2003;92:463\u20136.","journal-title":"Am J Cardiol"},{"issue":"9","key":"407_CR14","doi-asserted-by":"crossref","first-page":"1012","DOI":"10.4244\/EIJV8I9A156","volume":"8","author":"S Kesavan","year":"2013","unstructured":"Kesavan S, Strange JW, Johnson TW, Flohr RS, Baumbach A. First-in-man evaluation of the MOMO cobalt\u2013chromium carbon-coated stent. EuroIntervention. 2013;8(9):1012\u20138.","journal-title":"EuroIntervention"},{"issue":"3","key":"407_CR15","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1016\/j.ijcard.2004.12.034","volume":"104","author":"R Iijima","year":"2005","unstructured":"Iijima R, Ikari Y, Amiya E, Tanimoto S, Nakazawa G, Kyono H, et al. The impact of metallic allergy on stent implantation: metal allergy and recurrence of in-stent restenosis. Int J Cardiol. 2005;104(3):319\u201325.","journal-title":"Int J Cardiol"},{"issue":"2","key":"407_CR16","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/S1054-8807(03)00132-7","volume":"13","author":"K Inoue","year":"2004","unstructured":"Inoue K, Abe K, Ando K, Shirai S, Nishiyama K, Nakanishi M, et al. Pathological analyses of long-term intracoronary Palmaz-Schatz stenting; Is its efficacy permanent? Cardiovasc Pathol. 2004;13(2):109\u201315.","journal-title":"Cardiovasc Pathol."}],"container-title":["Cardiovascular Intervention and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s12928-016-0407-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12928-016-0407-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12928-016-0407-z","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12928-016-0407-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,6,26]],"date-time":"2017-06-26T21:56:16Z","timestamp":1498514176000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s12928-016-0407-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,7,22]]},"references-count":16,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017,7]]}},"alternative-id":["407"],"URL":"https:\/\/doi.org\/10.1007\/s12928-016-0407-z","relation":{},"ISSN":["1868-4300","1868-4297"],"issn-type":[{"value":"1868-4300","type":"print"},{"value":"1868-4297","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,7,22]]}}}