{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,4,27]],"date-time":"2023-04-27T15:03:38Z","timestamp":1682607818016},"reference-count":11,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2016,8,24]],"date-time":"2016-08-24T00:00:00Z","timestamp":1471996800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Cardiovasc Interv and Ther"],"published-print":{"date-parts":[[2017,7]]},"DOI":"10.1007\/s12928-016-0420-2","type":"journal-article","created":{"date-parts":[[2016,8,24]],"date-time":"2016-08-24T10:27:25Z","timestamp":1472034445000},"page":"279-286","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Nine-year follow-up of progressive peri-stent contrast staining after Cypher sirolimus-eluting stent implantation: a case report"],"prefix":"10.1007","volume":"32","author":[{"given":"Masayuki","family":"Hyogo","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takahisa","family":"Sawada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jun","family":"Shiraishi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshio","family":"Kohno","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2016,8,24]]},"reference":[{"key":"420_CR1","doi-asserted-by":"crossref","first-page":"2382","DOI":"10.1161\/CIRCULATIONAHA.110.003459","volume":"123","author":"M Imai","year":"2011","unstructured":"Imai M, Kadota K, Goto T, Fujii S, Yamamoto H, Fuku Y, et al. Incidence, risk factors, and clinical sequelae of angiographic peri-stent contrast staining after sirolimus-eluting stent implantation. Circulation. 2011;123:2382\u201391.","journal-title":"Circulation"},{"key":"420_CR2","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1007\/s12928-014-0248-6","volume":"29","author":"M Imai","year":"2014","unstructured":"Imai M, Kimura T, Morimoto T, Saito N, Shiomi H, Kawaguchi R, et al. Impact of angiographic peri-stent contrast staining (PSS) on late adverse events after sirolimus-eluting stent implantation: an observation from the multicenter j-Cypher registry PSS substudy. Cardiovasc Interv Ther. 2014;29:226\u201336.","journal-title":"Cardiovasc Interv Ther."},{"key":"420_CR3","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.jjcc.2007.08.001","volume":"51","author":"K Inoue","year":"2008","unstructured":"Inoue K, Mitsudo K, Nobuyoshi M. Medial necrosis due to sirolimus-eluting stent implantation in human coronary artery. J Cardiol. 2008;51:60\u20134.","journal-title":"J Cardiol"},{"key":"420_CR4","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1007\/s12928-013-0201-0","volume":"29","author":"S Fukui","year":"2014","unstructured":"Fukui S, Endo H, Nakajima S, Takahashi T, Nakamura A, Nozaki E. A case report of very late stent thrombosis observed simultaneously in all three vessels 5\u00a0years after sirolimus-eluting stent implantation. Cardiovasc Interv Ther. 2014;29:151\u20136.","journal-title":"Cardiovasc Interv Ther."},{"key":"420_CR5","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1161\/01.CIR.0000116202.41966.D4","volume":"109","author":"R Virmani","year":"2004","unstructured":"Virmani R, Guagliumi G, Farb A, Musumeci G, Grieco N, Motta T, et al. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious? Circulation. 2004;109:701\u20135.","journal-title":"Circulation"},{"key":"420_CR6","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1161\/CIRCINTERVENTIONS.110.958090","volume":"4","author":"H Kon","year":"2011","unstructured":"Kon H, Sakai H, Otsubo M, Takano H, Okamoto K, Sato T, et al. Contrast staining outside the sirolimus-eluting stent leading to coronary aneurysm formation: a case of very late stent thrombosis associated with hypersensitivity reaction. Circ Cardiovasc Interv. 2011;4:e1\u20133.","journal-title":"Circ Cardiovasc Interv."},{"key":"420_CR7","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.jjcc.2007.11.002","volume":"51","author":"T Okamura","year":"2008","unstructured":"Okamura T, Hiro T, Fujii T, Yamada J, Fukumoto Y, Hashimoto G, et al. Late giant coronary aneurysm associated with a fracture of sirolimus eluting stent: a case report. J Cardiol. 2008;51:74\u20139.","journal-title":"J Cardiol"},{"key":"420_CR8","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1016\/j.athoracsur.2008.11.077","volume":"88","author":"SH Kim","year":"2009","unstructured":"Kim SH, Kim HJ, Han SW, Jung SM, Kim JS, Chee HK, et al. A fractured sirolimus-eluting stent with a coronary aneurysm. Ann Thorac Surg. 2009;88:664\u20135.","journal-title":"Ann Thorac Surg"},{"key":"420_CR9","doi-asserted-by":"crossref","first-page":"S125","DOI":"10.2459\/JCM.0b013e32833dae07","volume":"16","author":"M D\u2019Amico","year":"2015","unstructured":"D\u2019Amico M, Frisenda V, Conrotto F, Pennone M, Scacciatella P, Marra S. Fracture of coronary artery sirolimus eluting stent with formation of four aneurysms. J Cardiovasc Med. 2015;16:S125\u20139.","journal-title":"J Cardiovasc Med"},{"key":"420_CR10","doi-asserted-by":"crossref","first-page":"E15","DOI":"10.1002\/ccd.25815","volume":"87","author":"H Lu","year":"2016","unstructured":"Lu H, Ge L, Ge J. Coronary aneurysm and stent fracture following stenting of a myocardial bridge. Catheter Cardiovasc Interv. 2016;87:E15\u20138.","journal-title":"Catheter Cardiovasc Interv"},{"key":"420_CR11","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1161\/CIRCINTERVENTIONS.112.968487","volume":"5","author":"T Tada","year":"2012","unstructured":"Tada T, Kadota K, Hosogi S, Kubo S, Ozaki M, Yoshino M, et al. Optical coherence tomography findings in lesions after sirolimus-eluting stent implantation with peri-stent contrast staining. Circ Cardiovasc Interv. 2012;5:649\u201356.","journal-title":"Circ Cardiovasc Interv."}],"container-title":["Cardiovascular Intervention and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s12928-016-0420-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12928-016-0420-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12928-016-0420-2","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12928-016-0420-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,6,26]],"date-time":"2017-06-26T21:56:39Z","timestamp":1498514199000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s12928-016-0420-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,8,24]]},"references-count":11,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017,7]]}},"alternative-id":["420"],"URL":"https:\/\/doi.org\/10.1007\/s12928-016-0420-2","relation":{},"ISSN":["1868-4300","1868-4297"],"issn-type":[{"value":"1868-4300","type":"print"},{"value":"1868-4297","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,8,24]]}}}