{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T11:26:04Z","timestamp":1788953164218,"version":"build-2803163510"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2016,11,21]],"date-time":"2016-11-21T00:00:00Z","timestamp":1479686400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100000327","name":"Heart Research UK","doi-asserted-by":"publisher","award":["RG2625"],"award-info":[{"award-number":["RG2625"]}],"id":[{"id":"10.13039\/501100000327","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Cardiovasc Eng Tech"],"published-print":{"date-parts":[[2017,3]]},"DOI":"10.1007\/s13239-016-0284-8","type":"journal-article","created":{"date-parts":[[2016,11,21]],"date-time":"2016-11-21T23:25:40Z","timestamp":1479770740000},"page":"17-29","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":34,"title":["Pledget-Armed Sutures Affect the Haemodynamic Performance of Biologic Aortic Valve Substitutes: A Preliminary Experimental and Computational Study"],"prefix":"10.1007","volume":"8","author":[{"given":"Claudio","family":"Capelli","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chiara","family":"Corsini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dario","family":"Biscarini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Ruffini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Migliavacca","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alfred","family":"Kocher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guenther","family":"Laufer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew M.","family":"Taylor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Silvia","family":"Schievano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Andreas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gaetano","family":"Burriesci","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claus","family":"Rath","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2016,11,21]]},"reference":[{"key":"284_CR1","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1093\/icvts\/ivw052","volume":"22","author":"M Andreas","year":"2016","unstructured":"Andreas, M., S. Wallner, A. Habertheuer, T. Binder, R. Rosenhek, D. Wiedemann, et al. Conventional versus rapid deployment aortic valve replacement: a single center comparison between the Edwards Magna valve and its rapid deployment successor. Interact. CardioVasc. Thorac. Surg. 22:799\u2013805, 2016.","journal-title":"Interact. CardioVasc. Thorac. Surg."},{"key":"284_CR2","unstructured":"Ansys. Fluent V15 Documentation, 2015."},{"issue":"2","key":"284_CR3","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1016\/j.jtcvs.2012.12.087","volume":"147","author":"JE Bavaria","year":"2014","unstructured":"Bavaria, J. E., N. D. Desai, A. Cheung, M. R. Petracek, M. A. Groh, M. A. Borger, and H. V. Schaff. The St Jude Medical Trifecta aortic pericardial valve: results from a global, multicenter, prospective clinical study. J. Thorac. Cardiovasc. Surg. 147(2):590\u2013597, 2014.","journal-title":"J. Thorac. Cardiovasc. Surg."},{"issue":"4","key":"284_CR4","doi-asserted-by":"crossref","first-page":"e0154517","DOI":"10.1371\/journal.pone.0154517","volume":"11","author":"AM Bavo","year":"2016","unstructured":"Bavo, A. M., G. Rocatello, F. Iannaccone, J. Degroote, J. Vierendeels, and P. Segers. Fluid\u2013structure interaction simulation of prosthetic aortic valves: comparison between immersed boundary and arbitrary Lagrangian\u2013Eulerian techniques for the mesh representation. PLoS ONE 11(4):e0154517, 2016.","journal-title":"PLoS ONE"},{"issue":"2","key":"284_CR5","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1115\/1.429634","volume":"122","author":"D Bluestein","year":"2000","unstructured":"Bluestein, D., E. Rambod, and M. Gharib. Vortex shedding as a mechanism for free emboli formation in mechanical heart valves. J. Biomech. Eng. 122(2):125\u2013134, 2000.","journal-title":"J. Biomech. Eng."},{"issue":"2","key":"284_CR6","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1007\/s10439-009-9807-x","volume":"28","author":"I Borazjani","year":"2010","unstructured":"Borazjani, I., L. Ge, and F. Sotiropoulos. High-resolution fluid\u2013structure interaction simulations of flow through a bi-leaflet mechanical heart valve in an anatomic aorta. Ann. Biomed. Eng. 28(2):326\u2013344, 2010.","journal-title":"Ann. Biomed. Eng."},{"issue":"3","key":"284_CR7","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1016\/j.jtcvs.2004.03.021","volume":"128","author":"T Bottio","year":"2004","unstructured":"Bottio, T., L. Caprili, D. Casarotto, and G. Gerosa. Small aortic annulus: the hydrodynamic performances of 5 commercially available bileaflet mechanical valves. J. Thorac. Cardiovasc. Surg. 128(3):457\u2013462, 2004.","journal-title":"J. Thorac. Cardiovasc. Surg."},{"issue":"9667","key":"284_CR8","doi-asserted-by":"crossref","first-page":"956","DOI":"10.1016\/S0140-6736(09)60211-7","volume":"373","author":"BA Carabello","year":"2009","unstructured":"Carabello, B. A. Aortic stenosis. Lancet 373(9667):956\u2013966, 2009.","journal-title":"Lancet"},{"issue":"7","key":"284_CR9","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1007\/s10237-012-0375-x","volume":"11","author":"S Chandra","year":"2012","unstructured":"Chandra, S., N. M. Rajamannan, and P. Sucosky. Computational assessment of bicuspid aortic valve wall-shear stress: implications for calcific aortic valve disease. Biomech Model. Mechanobiol. 11(7):1085\u20131096, 2012.","journal-title":"Biomech Model. Mechanobiol."},{"issue":"2","key":"284_CR10","doi-asserted-by":"crossref","first-page":"021021","DOI":"10.1115\/1.4023235","volume":"135","author":"TE Claiborne","year":"2013","unstructured":"Claiborne, T. E., J. Sheriff, M. Kuetting, U. Steinseifer, M. J. Slepian, and D. Bluestein. In vitro evaluation of a novel hemodynamically optimized trileaflet polymeric prosthetic heart valve. J. Biomech. Eng. 135(2):021021, 2013.","journal-title":"J. Biomech. Eng."},{"issue":"3","key":"284_CR11","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1097\/MAT.0b013e31828e4d80","volume":"59","author":"TE Claiborne","year":"2013","unstructured":"Claiborne, T. E., M. Xenos, J. Sheriff, W. C. Chiu, J. Soares, Y. Alemu, S. Gupta, S. Judex, M. J. Slepian, and D. Bluestein. Towards optimization of a novel trileaflet polymeric prosthetic heart valve via device thrombogenicity emulation (DTE). ASAIO J. 59(3):275, 2013.","journal-title":"ASAIO J."},{"issue":"2","key":"284_CR12","doi-asserted-by":"crossref","first-page":"596","DOI":"10.1016\/0003-4975(96)00418-3","volume":"62","author":"DM Cosgrove","year":"1996","unstructured":"Cosgrove, D. M., and J. F. Sabik. Minimally invasive approach for aortic valve operations. Ann. Thorac. Surg. 62(2):596\u2013597, 1996.","journal-title":"Ann. Thorac. Surg."},{"issue":"5","key":"284_CR13","first-page":"688","volume":"22","author":"A Ducci","year":"2013","unstructured":"Ducci, A., S. Tzamtzis, M. J. Mullen, and G. Burriesci. Hemodynamics in the Valsalva sinuses after transcatheter aortic valve implantation (TAVI). J. Heart Valve Dis. 22(5):688\u2013696, 2013.","journal-title":"J. Heart Valve Dis."},{"issue":"4","key":"284_CR14","doi-asserted-by":"crossref","first-page":"558","DOI":"10.1115\/1.2746378","volume":"129","author":"K Dumont","year":"2007","unstructured":"Dumont, K., J. Vierendeels, R. Kaminsky, G. Van Nooten, P. Verdonck, and D. Bluestein. Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD\/FSI model. J. Biomech. Eng. 129(4):558\u2013565, 2007.","journal-title":"J. Biomech. Eng."},{"key":"284_CR15","doi-asserted-by":"crossref","first-page":"1453","DOI":"10.1016\/j.jtcvs.2011.02.021","volume":"142","author":"W Flameng","year":"2011","unstructured":"Flameng, W., M.-C. Herregods, H. Hermans, G. Van Der Mieren, M. Vercalsteren, G. Poortmans, et al. Effect of sutureless implantation of the Perceval S aortic valve bioprosthesis on intraoperative and early postoperative outcomes. J. Thorac. Cardiovasc. Surg. 142:1453\u20131457, 2011.","journal-title":"J. Thorac. Cardiovasc. Surg."},{"issue":"1","key":"284_CR16","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.jtcvs.2012.07.108","volume":"145","author":"AA Kocher","year":"2013","unstructured":"Kocher, A. A., G. Laufer, A. Haverich, M. Shrestha, T. Walther, M. Misfeld, et al. One-year outcomes of the surgical treatment of aortic stenosis with a next generation surgical aortic valve (TRITON) trial: a prospective multicenter study of rapid-deployment aortic valve replacement with the Edwards Intuity Valve System. J. Thorac. Cardiovasc. Surg. 145(1):110\u2013116, 2013.","journal-title":"J. Thorac. Cardiovasc. Surg."},{"issue":"3","key":"284_CR17","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1016\/j.ejcts.2004.12.003","volume":"27","author":"R-U Kuehnel","year":"2005","unstructured":"Kuehnel, R.-U., R. Puchner, A. Pohl, M. O. Wendt, M. Hartrumpf, M. Pohl, and J. M. Albes. Characteristic resistance curves of aortic valve substitutes facilitate individualized decision for a particular type. Eur. J. Cardiothorac. Surg. 27(3):450\u2013455, 2005.","journal-title":"Eur. J. Cardiothorac. Surg."},{"issue":"4","key":"284_CR18","doi-asserted-by":"crossref","first-page":"1288","DOI":"10.1007\/s10439-010-9949-x","volume":"38","author":"A Les","year":"2010","unstructured":"Les, A., S. Shadden, C. A. Figueroa, J. Park, M. M. Tedesco, R. J. Herfkens, R. L. Dalman, and C. A. Taylor. Quantification of hemodynamics in abdominal aortic aneurysms during rest and exercise using magnetic resonance imaging and computational fluid dynamics. Ann. Biomed. Eng. 38(4):1288\u20131313, 2010.","journal-title":"Ann. Biomed. Eng."},{"issue":"4","key":"284_CR19","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1097\/MAT.0b013e3180683b7c","volume":"53","author":"G Mareels","year":"2007","unstructured":"Mareels, G., R. Kaminsky, S. Eloot, and P. R. Verdonck. Particle image velocimetry-validated, computational fluid dynamics-based design to reduce shear stress and residence time in central venous hemodialysis catheters. ASAIO J. 53(4):438\u2013446, 2007.","journal-title":"ASAIO J."},{"issue":"2","key":"284_CR20","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1007\/s11517-011-0849-5","volume":"50","author":"G Marom","year":"2012","unstructured":"Marom, G., R. Haj-Ali, E. Raanani, H. J. Sch\u00e4fers, and M. Rosenfeld. A fluid\u2013structure interaction model of the aortic valve with coaptation and compliant aortic root. Med. Biol. Eng. Comput. 50(2):173\u2013182, 2012.","journal-title":"Med. Biol. Eng. Comput."},{"issue":"6","key":"284_CR21","first-page":"802","volume":"10","author":"S Marquez","year":"2001","unstructured":"Marquez, S., R. T. Hon, and A. P. Yoganathan. Comparative hydrodynamic evaluation of bioprosthetic heart valves. J. Heart Valve Dis. 10(6):802\u2013811, 2001.","journal-title":"J. Heart Valve Dis."},{"key":"284_CR22","doi-asserted-by":"crossref","first-page":"1598","DOI":"10.2514\/3.12149","volume":"32","author":"FR Menter","year":"1994","unstructured":"Menter, F. R. Two-equation eddy-viscosity turbulence models for engineering applications. AIAA J. 32:1598\u20131605, 1994.","journal-title":"AIAA J."},{"issue":"1","key":"284_CR23","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1146\/annurev.fl.24.010192.001433","volume":"24","author":"HK Moffatt","year":"1992","unstructured":"Moffatt, H. K., and A. Tsinober. Helicity in laminar and turbulent flow. Annu. Rev. Fluid Mech. 24(1):281\u2013312, 1992.","journal-title":"Annu. Rev. Fluid Mech."},{"key":"284_CR24","doi-asserted-by":"crossref","first-page":"899","DOI":"10.1016\/j.jbiomech.2015.02.027","volume":"48","author":"U Morbiducci","year":"2015","unstructured":"Morbiducci, U., D. Gallo, S. Cristofanelli, R. Ponzini, M. A. Deriu, G. Rizzo, and D. A. Steinman. A rational approach to defining principal axes of multidirectional wall shear stress in realistic vascular geometries, with application to the study of the influence of helical flow on wall shear stress directionality in aorta. J. Biomech. 48:899\u2013906, 2015.","journal-title":"J. Biomech."},{"issue":"22","key":"284_CR25","doi-asserted-by":"crossref","first-page":"2438","DOI":"10.1016\/j.jacc.2014.02.537","volume":"63","author":"RA Nishimura","year":"2014","unstructured":"Nishimura, R. A., C. M. Otto, R. O. Bonow, B. A. Carabello, J. P. Erwin, R. A. Guyton, et al. 2014 AHA\/ACC guideline for the management of patients with valvular heart disease: executive summary. J. Am. Coll. Cardiol. 63(22):2438\u20132488, 2014.","journal-title":"J. Am. Coll. Cardiol."},{"issue":"2","key":"284_CR26","first-page":"100","volume":"4","author":"K Phan","year":"2015","unstructured":"Phan, K., Y.-C. Tsai, N. Niranjan, D. Bouchard, T. P. Carrel, O. E. Dapunt, et al. Sutureless aortic valve replacement: a systematic review and meta-analysis. Ann. Cardiothorac. Surg. 4(2):100\u2013111, 2015.","journal-title":"Ann. Cardiothorac. Surg."},{"issue":"7","key":"284_CR27","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1016\/j.jbiomech.2012.01.046","volume":"45","author":"B Rahmani","year":"2012","unstructured":"Rahmani, B., S. Tzamtzis, H. Ghanbari, G. Burriesci, and A. M. Seifalian. Manufacturing and hydrodynamic assessment of a novel aortic valve made of a new nanocomposite polymer. J. Biomech. 45(7):1205\u20131211, 2012.","journal-title":"J. Biomech."},{"issue":"2","key":"284_CR28","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1111\/j.1525-1594.2010.01048.x","volume":"35","author":"E Sirois","year":"2011","unstructured":"Sirois, E., and W. Sun. Computational evaluation of platelet activation induced by a bioprosthetic heart valve. Artif. Organs 35(2):157\u2013165, 2011.","journal-title":"Artif. Organs"},{"issue":"1","key":"284_CR29","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1016\/j.jtcvs.2012.11.020","volume":"147","author":"M Tabata","year":"2014","unstructured":"Tabata, M., K. Shibayama, H. Watanabe, Y. Sato, T. Fukui, and S. Takanashi. Simple interrupted suturing increases valve performance after aortic valve replacement with a small supra-annular bioprosthesis. J. Thorac. Cardiovasc. Surg. 147(1):321\u2013325, 2014.","journal-title":"J. Thorac. Cardiovasc. Surg."},{"issue":"3","key":"284_CR30","doi-asserted-by":"crossref","first-page":"912","DOI":"10.1016\/j.jtcvs.2014.10.096","volume":"149","author":"G Tasca","year":"2015","unstructured":"Tasca, G., et al. Does the type of suture technique affect the fluid-dynamic performance of bioprostheses implanted in small aortic roots? Results from an in vitro study. J. Thorac. Cardiovasc. Surg. 149(3):912\u2013918, 2015.","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"284_CR31","unstructured":"The International Standard Cardiovascular implants\u2014Cardiac Valve Prostheses (ISO 5840: 2009)."},{"issue":"5","key":"284_CR32","doi-asserted-by":"crossref","first-page":"1940","DOI":"10.1016\/j.jtcvs.2013.12.051","volume":"148","author":"M Ugur","year":"2014","unstructured":"Ugur, M., R. M. Suri, R. C. Daly, J. A. Dearani, S. J. Park, L. D. Joyce, H. M. Burkhart, K. L. Greason, and H. V. Schaff. Comparison of early hemodynamic performance of 3 aortic valve bioprostheses. J. Thorac. Cardiovasc. Surg. 148(5):1940\u20131946, 2014.","journal-title":"J. Thorac. Cardiovasc. Surg."},{"issue":"4","key":"284_CR33","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jtcvs.2013.12.006","volume":"148","author":"M Ugur","year":"2014","unstructured":"Ugur, M., J. G. Byrne, J. E. Bavaria, A. Cheung, M. Petracek, M. A. Groh, et al. Suture technique does not affect hemodynamic performance of the small supra-annular Trifecta bioprosthesis. J. Thorac. Cardiovasc. Surg. 148(4):1\u20136, 2014.","journal-title":"J. Thorac. Cardiovasc. Surg."},{"issue":"19","key":"284_CR34","doi-asserted-by":"crossref","first-page":"2451","DOI":"10.1093\/eurheartj\/ehs109","volume":"33","author":"A Vahanian","year":"2012","unstructured":"Vahanian, A., O. Alfieri, F. Andreotti, M. J. Antunes, G. Bar\u00f3n-Esquivias, H. Baumgartner, M. A. Borger, T. P. Carrel, M. De Bonis, A. Evangelista, and V. Falk. Guidelines on the management of valvular heart disease (version 2012). Eur. Heart J. 33(19):2451\u20132496, 2012.","journal-title":"Eur. Heart J."},{"issue":"7","key":"284_CR35","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1046\/j.1525-1594.2002.00920.x","volume":"26","author":"P Verdonck","year":"2002","unstructured":"Verdonck, P. The role of computational fluid dynamics for artificial organ design. Artif. Organs 26(7):569\u2013570, 2002.","journal-title":"Artif. Organs"},{"issue":"5","key":"284_CR36","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1111\/jocs.12384","volume":"29","author":"LW Wollersheim","year":"2014","unstructured":"Wollersheim, L. W., W. W. Li, and B. A. de Mol. Current status of surgical treatment for aortic valve stenosis. J. Card. Surg. 29(5):630\u2013637, 2014.","journal-title":"J. Card. Surg."},{"issue":"2","key":"284_CR37","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1007\/s10439-015-1429-x","volume":"44","author":"W Wu","year":"2016","unstructured":"Wu, W., D. Pott, B. Mazza, T. Sironi, E. Dordoni, C. Chiastra, L. Petrini, G. Pennati, G. Dubini, U. Steinseifer, and S. Sonntag. Fluid-structure interaction model of a percutaneous aortic valve: comparison with an in vitro test and feasibility study in a patient-specific case. Ann. Biomed. Eng. 44(2):590\u2013603, 2016.","journal-title":"Ann. Biomed. Eng."},{"key":"284_CR38","doi-asserted-by":"crossref","first-page":"2400","DOI":"10.1016\/j.jbiomech.2010.04.020","volume":"43","author":"M Xenos","year":"2010","unstructured":"Xenos, M., G. Girdhar, Y. Alemu, J. Jesty, M. Slepian, S. Einav, et al. Device thrombogenicity emulator (DTE)\u2014Design optimization methodology for cardiovascular devices: a study in two bileaflet MHV designs. J. Biomech. 43:2400\u20132409, 2010.","journal-title":"J. Biomech."}],"container-title":["Cardiovascular Engineering and Technology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s13239-016-0284-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s13239-016-0284-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s13239-016-0284-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,20]],"date-time":"2024-06-20T18:45:52Z","timestamp":1718909152000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s13239-016-0284-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,11,21]]},"references-count":38,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017,3]]}},"alternative-id":["284"],"URL":"https:\/\/doi.org\/10.1007\/s13239-016-0284-8","relation":{},"ISSN":["1869-408X","1869-4098"],"issn-type":[{"value":"1869-408X","type":"print"},{"value":"1869-4098","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,11,21]]}}}