{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T04:32:44Z","timestamp":1791261164147,"version":"4.1.0"},"reference-count":83,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2019,7,15]],"date-time":"2019-07-15T00:00:00Z","timestamp":1563148800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,7,15]],"date-time":"2019-07-15T00:00:00Z","timestamp":1563148800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Cardiovasc Eng Tech"],"published-print":{"date-parts":[[2019,9]]},"DOI":"10.1007\/s13239-019-00427-0","type":"journal-article","created":{"date-parts":[[2019,7,29]],"date-time":"2019-07-29T11:55:57Z","timestamp":1564401357000},"page":"437-455","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":91,"title":["On the Modeling of Patient-Specific Transcatheter Aortic Valve Replacement: A Fluid\u2013Structure Interaction Approach"],"prefix":"10.1007","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0434-8544","authenticated-orcid":false,"given":"Giulia","family":"Luraghi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Migliavacca","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alberto","family":"Garc\u00eda-Gonz\u00e1lez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claudio","family":"Chiastra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexia","family":"Rossi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Davide","family":"Cao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giulio","family":"Stefanini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jose Felix","family":"Rodriguez Matas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,7,15]]},"reference":[{"key":"427_CR1","doi-asserted-by":"publisher","first-page":"3663","DOI":"10.1016\/j.jbiomech.2015.08.012","volume":"48","author":"M Abbasi","year":"2015","unstructured":"Abbasi, M., and A. N. Azadani. Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion. J. Biomech. 48:3663\u20133671, 2015.","journal-title":"J. Biomech."},{"key":"427_CR2","doi-asserted-by":"publisher","first-page":"1527","DOI":"10.4244\/EIJ-D-17-00595","volume":"13","author":"M Abdelghani","year":"2018","unstructured":"Abdelghani, M., Y. Miyazaki, E. De Boer, J.-P. Aben, M. Van Sloun, T. Suchecki, et al. Videodensitometric quantification of paravalvular regurgitation of a transcatheter aortic valve: in vitro validation. EuroIntervention. 13:1527\u20131535, 2018.","journal-title":"EuroIntervention."},{"key":"427_CR3","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1002\/cnm.1234","volume":"26","author":"V Alastru\u00e9","year":"2010","unstructured":"Alastru\u00e9, V., A. Gar\u00eda, E. Pe\u00f1a, J. F. Rodr\u00edguez, M. A. Mart\u00ednez, and M. Doblar\u00e9. Numerical framework for patient-specific computational modelling of vascular tissue. Int. J. Numer. Method Biomed. Eng. 26:35\u201351, 2010.","journal-title":"Int. J. Numer. Method Biomed. Eng."},{"key":"427_CR4","doi-asserted-by":"publisher","first-page":"1347","DOI":"10.1080\/10255842.2012.746676","volume":"17","author":"F Auricchio","year":"2014","unstructured":"Auricchio, F., M. Conti, S. Morganti, and A. Reali. Simulation of transcatheter aortic valve implantation: a patient-specific finite element approach. Comput. Methods Biomech. Biomed. Eng. 17:1347\u20131357, 2014.","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"427_CR5","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1080\/10255842.2015.1058928","volume":"19","author":"J Bailey","year":"2016","unstructured":"Bailey, J., N. Curzen, and N. W. Bressloff. Assessing the impact of including leaflets in the simulation of TAVI deployment into a patient-specific aortic root. Comput. Methods Biomech. Biomed. Eng. 19:733\u2013744, 2016.","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"427_CR6","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1016\/j.jbiomech.2016.12.031","volume":"53","author":"J Bailey","year":"2017","unstructured":"Bailey, J., N. Curzen, and N. W. Bressloff. The impact of imperfect frame deployment and rotational orientation on stress within the prosthetic leaflets during transcatheter aortic valve implantation. J. Biomech. 53:22\u201328, 2017.","journal-title":"J. Biomech."},{"key":"427_CR7","doi-asserted-by":"publisher","first-page":"1513","DOI":"10.1166\/jmihi.2016.1840","volume":"6","author":"AA Basri","year":"2016","unstructured":"Basri, A. A., M. Zuber, M. S. Zakaria, E. I. Basri, A. F. A. Aziz, R. M. Ali, et al. The hemodynamic effects of paravalvular leakage using fluid structure interaction; transcatheter aortic valve implantation patient. J. Med. Imaging Health Inform. 6:1513\u20131518, 2016.","journal-title":"J. Med. Imaging Health Inform."},{"key":"427_CR8","doi-asserted-by":"publisher","first-page":"e0154517","DOI":"10.1371\/journal.pone.0154517","volume":"11","author":"AM Bavo","year":"2016","unstructured":"Bavo, A. M., G. Rocatello, F. Iannaccone, J. Degroote, J. Vierendeels, and P. Segers. Fluid-structure interaction simulation of prosthetic aortic valves: comparison between immersed boundary and arbitrary Lagrangian-Eulerian techniques for the mesh representation. PLoS ONE. 11:e0154517, 2016.","journal-title":"PLoS ONE."},{"key":"427_CR9","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1016\/0045-7825(84)90026-4","volume":"42","author":"T Belytschko","year":"1984","unstructured":"Belytschko, T., J. I. Lin, and T. Chen-Shyh. Explicit algorithms for the nonlinear dynamics of shells. Comput. Methods Appl. Mech. Eng. 42:225\u2013251, 1984.","journal-title":"Comput. Methods Appl. Mech. Eng."},{"key":"427_CR10","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1016\/0045-7825(81)90048-7","volume":"29","author":"T Belytschko","year":"1981","unstructured":"Belytschko, T., C. S. Tsay, and W. K. Liu. A stabilization matrix for the bilinear mindlin plate element. Comput. Methods Appl. Mech. Eng. 29:313\u2013327, 1981.","journal-title":"Comput. Methods Appl. Mech. Eng."},{"key":"427_CR11","doi-asserted-by":"publisher","first-page":"E292","DOI":"10.1111\/aor.12806","volume":"40","author":"M Bianchi","year":"2016","unstructured":"Bianchi, M., G. Marom, R. P. Ghosh, H. A. Fernandez, J. R. Taylor, M. J. Slepian, et al. Effect of balloon-expandable transcatheter aortic valve replacement positioning: a patient-specific numerical model. Artif. Org. 40:E292\u2013E304, 2016.","journal-title":"Artif. Org."},{"key":"427_CR12","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1007\/s10237-018-1094-8","volume":"18","author":"M Bianchi","year":"2019","unstructured":"Bianchi, M., G. Marom, R. P. Ghosh, O. M. Rotman, P. Parikh, L. Gruberg, et al. Patient-specific simulation of transcatheter aortic valve replacement: impact of deployment options on paravalvular leakage. Biomech. Model Mechanobiol. 18:435\u2013451, 2019.","journal-title":"Biomech. Model Mechanobiol."},{"key":"427_CR13","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1016\/j.jbiomech.2018.02.017","volume":"71","author":"GM Bosi","year":"2018","unstructured":"Bosi, G. M., C. Capelli, M. H. Cheang, N. Delahunty, M. Mullen, A. M. Taylor, et al. Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations. J. Biomech. 71:236\u2013244, 2018.","journal-title":"J. Biomech."},{"key":"427_CR14","doi-asserted-by":"publisher","first-page":"2824","DOI":"10.1016\/j.jbiomech.2016.06.024","volume":"49","author":"B Bosmans","year":"2016","unstructured":"Bosmans, B., N. Famaey, E. Verhoelst, J. Bosmans, and Sloten J. Vander. A validated methodology for patient specific computational modeling of self-expandable transcatheter aortic valve implantation. J. Biomech. 49:2824\u20132830, 2016.","journal-title":"J. Biomech."},{"key":"427_CR15","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1016\/j.jmbbm.2017.02.006","volume":"68","author":"MS Cabrera","year":"2017","unstructured":"Cabrera, M. S., C. W. J. Oomens, and F. P. T. Baaijens. Understanding the requirements of self-expandable stents for heart valve replacement: Radial force, hoop force and equilibrium. J. Mech. Behav. Biomed. Mater. 68:252\u2013264, 2017.","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"427_CR16","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1007\/s11517-012-0864-1","volume":"50","author":"C Capelli","year":"2012","unstructured":"Capelli, C., G. M. Bosi, E. Cerri, J. Nordmeyer, T. Odenwald, P. Bonhoeffer, et al. Patient-specific simulations of transcatheter aortic valve stent implantation. Med. Biol. Eng. Comput. 50:183\u2013192, 2012.","journal-title":"Med. Biol. Eng. Comput."},{"key":"427_CR17","doi-asserted-by":"publisher","first-page":"310","DOI":"10.1007\/s10439-016-1759-3","volume":"45","author":"LP Dasi","year":"2017","unstructured":"Dasi, L. P., H. Hatoum, A. Kheradvar, R. Zareian, S. H. Alavi, W. Sun, et al. On the mechanics of transcatheter aortic valve replacement. Ann. Biomed. Eng. 45:310\u2013331, 2017.","journal-title":"Ann. Biomed. Eng."},{"issue":"5","key":"427_CR18","doi-asserted-by":"publisher","first-page":"508","DOI":"10.1016\/j.jcin.2016.01.003","volume":"9","author":"P De Jaegere","year":"2016","unstructured":"De Jaegere, P., G. De Santis, R. Rodriguez-Olivares, J. Bosmans, N. Bruining, T. Dezutter, et al. Patient-specific computer modeling to predict aortic regurgitation after transcatheter aortic valve replacement. JACC Cardiovasc. Interv. 9(5):508\u2013512, 2016.","journal-title":"JACC Cardiovasc. Interv."},{"key":"427_CR19","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1115\/1.1590361","volume":"125","author":"NJ Driessen","year":"2003","unstructured":"Driessen, N. J., R. A. Boerboom, J. M. Huyghe, C. V. Bouten, and F. P. Baaijens. Computational analyses of mechanically induced collagen fiber remodeling in the aortic heart valve. J. Biomech. Eng. 125:549\u2013557, 2003.","journal-title":"J. Biomech. Eng."},{"key":"427_CR20","doi-asserted-by":"publisher","first-page":"4080","DOI":"10.1016\/j.jbiomech.2016.10.050","volume":"49","author":"A Ducci","year":"2016","unstructured":"Ducci, A., F. Pirisi, S. Tzamtzis, and G. Burriesci. Transcatheter aortic valves produce unphysiological flows which may contribute to thromboembolic events: an in-vitro study. J. Biomech. 49:4080\u20134089, 2016.","journal-title":"J. Biomech."},{"key":"427_CR21","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1007\/s12471-016-0923-6","volume":"25","author":"N El Faquir","year":"2017","unstructured":"El Faquir, N., B. Ren, N. M. Van Mieghem, J. Bosmans, and P. P. De Jaegere. Patient-specific computer modelling\u2014its role in the planning of transcatheter aortic valve implantation. Neth. Heart J. 25:100\u2013105, 2017.","journal-title":"Neth. Heart J."},{"key":"427_CR22","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1016\/0735-1097(94)90432-4","volume":"23","author":"M Enriquez-Sarano","year":"1994","unstructured":"Enriquez-Sarano, M., J. B. Seward, K. R. Bailey, and A. J. Tajik. Effective regurgitant orifice area: a noninvasive Doppler development of an old hemodynamic concept. J. Am. Coll. Cardiol. 23:443\u2013451, 1994.","journal-title":"J. Am. Coll. Cardiol."},{"key":"427_CR23","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1016\/j.medengphy.2017.06.045","volume":"47","author":"A Finotello","year":"2017","unstructured":"Finotello, A., S. Morganti, and F. Auricchio. Finite element analysis of TAVI: impact of native aortic root computational modeling strategies on simulation outcomes. Med. Eng. Phys. 47:2\u201312, 2017.","journal-title":"Med. Eng. Phys."},{"key":"427_CR24","doi-asserted-by":"publisher","first-page":"1125","DOI":"10.1016\/j.jacc.2012.08.1039","volume":"61","author":"P G\u00e9n\u00e9reux","year":"2013","unstructured":"G\u00e9n\u00e9reux, P., S. J. Head, R. Hahn, B. Daneault, S. Kodali, M. R. Williams, et al. Paravalvular leak after transcatheter aortic valve replacement. J. Am. Coll. Cardiol. 61:1125\u20131136, 2013.","journal-title":"J. Am. Coll. Cardiol."},{"key":"427_CR25","doi-asserted-by":"publisher","first-page":"121002","DOI":"10.1115\/1.4040600","volume":"140","author":"RP Ghosh","year":"2018","unstructured":"Ghosh, R. P., G. Marom, O. M. Rotman, M. J. Slepian, S. Prabhakar, M. Horner, et al. Comparative fluid-structure interaction analysis of polymeric transcatheter and surgical aortic valves\u2019 hemodynamics and structural mechanics. J. Biomech. Eng. 140:121002, 2018.","journal-title":"J. Biomech. Eng."},{"key":"427_CR26","doi-asserted-by":"publisher","first-page":"1616","DOI":"10.1161\/CIRCULATIONAHA.106.639450","volume":"114","author":"E Grube","year":"2006","unstructured":"Grube, E., J. C. Laborde, U. Gerckens, T. Felderhoff, B. Sauren, L. Buellesfeld, et al. Percutaneous implantation of the CoreValve self-expanding valve prosthesis in high-risk patients with aortic valve disease: the siegburg first-in-man study. Circulation. 114:1616\u20131624, 2006.","journal-title":"Circulation."},{"issue":"113","key":"427_CR27","doi-asserted-by":"publisher","first-page":"20150737","DOI":"10.1098\/rsif.2015.0737","volume":"12","author":"PS Gunning","year":"2015","unstructured":"Gunning, P. S., N. Saikrishnan, A. P. Yoganathan, and L. M. McNamara. Total ellipse of the heart valve: the impact of eccentric stent distortion on the regional dynamic deformation of pericardial tissue leaflets of a transcatheter aortic valve replacement. J. R. Soc. Interface. 12(113):20150737, 2015.","journal-title":"J. R. Soc. Interface."},{"key":"427_CR28","doi-asserted-by":"publisher","first-page":"1989","DOI":"10.1007\/s10439-014-1051-3","volume":"42","author":"PS Gunning","year":"2014","unstructured":"Gunning, P. S., T. J. Vaughan, and L. M. McNamara. Simulation of self expanding transcatheter aortic valve in a realistic aortic root: implications of deployment geometry on leaflet deformation. Ann. Biomed. Eng. 42:1989\u20132001, 2014.","journal-title":"Ann. Biomed. Eng."},{"key":"427_CR29","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1023\/A:1010835316564","volume":"61","author":"GA Holzapfel","year":"2000","unstructured":"Holzapfel, G. A., T. C. Gasser, and R. W. Ogden. A new constitutive framework for arterial wall mechanics and a comparative study of material models. J. Elast. 61:1\u201348, 2000.","journal-title":"J. Elast."},{"key":"427_CR30","doi-asserted-by":"publisher","first-page":"3445","DOI":"10.1098\/rsta.2009.0091","volume":"367","author":"GA Holzapfel","year":"2009","unstructured":"Holzapfel, G. A., and R. W. Ogden. Constitutive modelling of passive myocardium: a structurally based framework for material characterization. Philos. Trans. R. Soc. A Math. Phys. Eng. Sci. 367:3445\u20133475, 2009.","journal-title":"Philos. Trans. R. Soc. A Math. Phys. Eng. Sci."},{"key":"427_CR31","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1115\/1.1800557","volume":"126","author":"GA Holzapfel","year":"2004","unstructured":"Holzapfel, G. A., G. Sommer, and P. Regitnig. Anisotropic mechanical properties of tissue components in human atherosclerotic plaques. J. Biomech. Eng. 126:657\u2013665, 2004.","journal-title":"J. Biomech. Eng."},{"key":"427_CR32","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.jbiomech.2016.12.038","volume":"53","author":"R Hopf","year":"2017","unstructured":"Hopf, R., S. H. S\u00fcndermann, S. Born, C. E. Ruiz, N. M. Van Mieghem, P. P. De Jaegere, et al. Postoperative analysis of the mechanical interaction between stent and host tissue in patients after transcatheter aortic valve implantation. J. Biomech. 53:15\u201321, 2017.","journal-title":"J. Biomech."},{"key":"427_CR33","unstructured":"https:\/\/www.medtronic.com\/us-en\/healthcareprofessionals\/products\/cardiovascular\/transcatheter-aortic-heart-valves\/evolut-pro.html\n                    \n                  ."},{"key":"427_CR34","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1007\/s00380-016-0885-z","volume":"32","author":"C Jung","year":"2017","unstructured":"Jung, C., M. Lichtenauer, H.-R. Figulla, B. Wernly, B. Goebel, M. Foerster, et al. Microparticles in patients undergoing transcatheter aortic valve implantation (TAVI). Heart Vessels. 32:458\u2013466, 2017.","journal-title":"Heart Vessels."},{"key":"427_CR35","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1016\/j.jmbbm.2018.06.032","volume":"86","author":"HS Kandail","year":"2018","unstructured":"Kandail, H. S., S. D. Trivedi, A. C. Shaikh, T. K. Bajwa, D. P. O\u2019Hair, A. Jahangir, et al. Impact of annular and supra-annular CoreValve deployment locations on aortic and coronary artery hemodynamics. J. Mech. Behav. Biomed. Mater. 86:131\u2013142, 2018.","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"427_CR36","doi-asserted-by":"publisher","first-page":"S45","DOI":"10.1093\/ejcts\/ezs533","volume":"42","author":"AP Kappetein","year":"2012","unstructured":"Kappetein, A. P., S. J. Head, P. Genereux, N. Piazza, N. M. Van Mieghem, E. H. Blackstone, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document (VARC-2). Eur. J. Cardio-Thoracic Surg. 42:S45\u2013S60, 2012.","journal-title":"Eur. J. Cardio-Thoracic Surg."},{"key":"427_CR37","first-page":"418","volume":"56","author":"A Kopanidis","year":"2015","unstructured":"Kopanidis, A., I. Pantos, N. Alexopoulos, A. Theodorakakos, E. Efstathopoulos, and D. Katritsis. Aortic flow patterns after simulated implantation of transcatheter aortic valves. Hellenic J. Cardiol. 56:418\u2013428, 2015.","journal-title":"Hellenic J. Cardiol."},{"key":"427_CR38","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1002\/nag.1610020105","volume":"2","author":"D Kosloff","year":"1978","unstructured":"Kosloff, D., and G. A. Frazier. Treatment of hourglass patterns in low order finite element codes. Int. J. Numer. Anal. Methods Geomech. 2:57\u201372, 1978.","journal-title":"Int. J. Numer. Anal. Methods Geomech."},{"key":"427_CR39","doi-asserted-by":"publisher","first-page":"1574","DOI":"10.1016\/j.amjcard.2015.02.059","volume":"115","author":"J Laflamme","year":"2015","unstructured":"Laflamme, J., R. Puri, M. Urena, L. Laflamme, H. DeLarochelli\u00e8re, O. Abdul-Jawad Altisent, et al. Incidence and risk factors of hemolysis after transcatheter aortic valve implantation with a balloon-expandable valve. Am. J. Cardiol. 115:1574\u20131579, 2015.","journal-title":"Am. J. Cardiol."},{"key":"427_CR40","doi-asserted-by":"publisher","first-page":"1996","DOI":"10.1056\/NEJMp1512264","volume":"373","author":"JC Laschinger","year":"2015","unstructured":"Laschinger, J. C., C. Wu, N. G. Ibrahim, and J. E. Shuren. Reduced leaflet motion in bioprosthetic aortic valves\u2014the FDA perspective. N. Engl. J. Med. 373:1996\u20131998, 2015.","journal-title":"N. Engl. J. Med."},{"key":"427_CR41","doi-asserted-by":"publisher","first-page":"2690","DOI":"10.1007\/s10439-010-0009-3","volume":"38","author":"K Li","year":"2010","unstructured":"Li, K., and W. Sun. Simulated thin pericardial bioprosthetic valve leaflet deformation under static pressure-only loading conditions: implications for percutaneous valves. Ann. Biomed. Eng. 38:2690\u20132701, 2010.","journal-title":"Ann. Biomed. Eng."},{"issue":"3","key":"427_CR42","doi-asserted-by":"publisher","first-page":"e02814","DOI":"10.1002\/cnm.2814","volume":"33","author":"K Li","year":"2016","unstructured":"Li, K., and W. Sun. Simulated transcatheter aortic valve deformation: a parametric study on the impact of leaflet geometry on valve peak stress. Int. J. Numer. Method Biomed. Eng. 33(3):e02814, 2016.","journal-title":"Int. J. Numer. Method Biomed. Eng."},{"key":"427_CR43","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s13239-018-00373-3","volume":"9","author":"G Luraghi","year":"2018","unstructured":"Luraghi, G., F. Migliavacca, and J. F. Rodriguez Matas. Study on the accuracy of structural and FSI heart valves simulations. Cardiovasc. Eng. Technol. 9:1\u201316, 2018.","journal-title":"Cardiovasc. Eng. Technol."},{"key":"427_CR44","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/j.jbiomech.2017.04.004","volume":"58","author":"G Luraghi","year":"2017","unstructured":"Luraghi, G., W. Wu, F. De Gaetano, J. F. Rodriguez Matas, G. D. Moggridge, M. Serrani, et al. Evaluation of an aortic valve prosthesis: fluid-structure interaction or structural simulation? J. Biomech. 58:45\u201351, 2017.","journal-title":"J. Biomech."},{"key":"427_CR45","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1007\/s40119-017-0100-z","volume":"6","author":"D Mahtta","year":"2017","unstructured":"Mahtta, D., I. Y. Elgendy, and A. A. Bavry. From CoreValve to evolut PRO: reviewing the journey of self-expanding transcatheter aortic valves. Cardiol. Ther. 6:183\u2013192, 2017.","journal-title":"Cardiol. Ther."},{"key":"427_CR46","doi-asserted-by":"publisher","first-page":"e0184729","DOI":"10.1371\/journal.pone.0184729","volume":"12","author":"W Mao","year":"2017","unstructured":"Mao, W., A. Caballero, R. McKay, C. Primiano, and W. Sun. Fully-coupled fluid-structure interaction simulation of the aortic and mitral valves in a realistic 3D left ventricle model. PLoS ONE. 12:e0184729, 2017.","journal-title":"PLoS ONE."},{"key":"427_CR47","doi-asserted-by":"publisher","first-page":"374","DOI":"10.1007\/s13239-016-0285-7","volume":"7","author":"W Mao","year":"2016","unstructured":"Mao, W., K. Li, and W. Sun. Fluid-structure interaction study of transcatheter aortic valve dynamics using smoothed particle hydrodynamics. Cardiovasc. Eng. Technol. 7:374\u2013388, 2016.","journal-title":"Cardiovasc. Eng. Technol."},{"key":"427_CR48","doi-asserted-by":"publisher","first-page":"101007","DOI":"10.1115\/1.4040457","volume":"140","author":"W Mao","year":"2018","unstructured":"Mao, W., Q. Wang, S. Kodali, and W. Sun. Numerical parametric study of paravalvular leak following a transcatheter aortic valve deployment into a patient-specific aortic root. J. Biomech. Eng. 140:101007, 2018.","journal-title":"J. Biomech. Eng."},{"key":"427_CR49","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1007\/s11831-014-9133-9","volume":"22","author":"G Marom","year":"2015","unstructured":"Marom, G. Numerical methods for fluid-structure interaction models of aortic valves. Arch. Comput. Methods Eng. 22:595\u2013620, 2015.","journal-title":"Arch. Comput. Methods Eng."},{"key":"427_CR50","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.ejcts.2010.08.056","volume":"40","author":"C Martin","year":"2011","unstructured":"Martin, C., T. Pham, and W. Sun. Significant differences in the material properties between aged human and porcine aortic tissues. Eur. J. Cardio-Thoracic Surg. 40:28\u201334, 2011.","journal-title":"Eur. J. Cardio-Thoracic Surg."},{"key":"427_CR51","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.ejcts.2010.08.056","volume":"40","author":"C Martin","year":"2011","unstructured":"Martin, C., T. Pham, and W. Sun. Significant differences in the material properties between aged human and porcine aortic tissues. Eur. J. Cardiothorac. Surg. 40:28\u201334, 2011.","journal-title":"Eur. J. Cardiothorac. Surg."},{"key":"427_CR52","doi-asserted-by":"publisher","first-page":"3026","DOI":"10.1016\/j.jbiomech.2015.07.031","volume":"48","author":"C Martin","year":"2015","unstructured":"Martin, C., and W. Sun. Comparison of transcatheter aortic valve and surgical bioprosthetic valve durability: A fatigue simulation study. J. Biomech. 48:3026\u20133034, 2015.","journal-title":"J. Biomech."},{"issue":"2","key":"427_CR53","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1007\/s10439-016-1738-8","volume":"45","author":"C Martin","year":"2017","unstructured":"Martin, C., and W. Sun. Transcatheter valve underexpansion limits leaflet durability: implications for valve-in-valve procedures. Ann. Biomed. Eng. 45(2):394\u2013404, 2017.","journal-title":"Ann. Biomed. Eng."},{"key":"427_CR54","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1016\/j.jcct.2017.11.002","volume":"12","author":"M Marwan","year":"2018","unstructured":"Marwan, M., N. Mekkhala, M. G\u00f6ller, J. R\u00f6ther, D. Bittner, A. Schuhbaeck, et al. Leaflet thrombosis following transcatheter aortic valve implantation. J. Cardiovasc. Comput. Tomogr. 12:8\u201313, 2018.","journal-title":"J. Cardiovasc. Comput. Tomogr."},{"key":"427_CR55","doi-asserted-by":"publisher","first-page":"586","DOI":"10.1016\/j.jacc.2016.04.063","volume":"68","author":"RB Morgan","year":"2016","unstructured":"Morgan, R. B., and R. Y. Kwong. When accurate flow quantitation matters. J. Am. Coll. Cardiol. 68:586\u2013588, 2016.","journal-title":"J. Am. Coll. Cardiol."},{"key":"427_CR56","doi-asserted-by":"publisher","first-page":"2513","DOI":"10.1016\/j.jbiomech.2015.10.048","volume":"49","author":"S Morganti","year":"2016","unstructured":"Morganti, S., N. Brambilla, A. S. Petronio, A. Reali, F. Bedogni, and F. Auricchio. Prediction of patient-specific post-operative outcomes of TAVI procedure: the impact of the positioning strategy on valve performance. J. Biomech. 49:2513\u20132519, 2016.","journal-title":"J. Biomech."},{"key":"427_CR57","doi-asserted-by":"publisher","first-page":"2547","DOI":"10.1016\/j.jbiomech.2014.06.007","volume":"47","author":"S Morganti","year":"2014","unstructured":"Morganti, S., M. Conti, M. Aiello, A. Valentini, A. Mazzola, A. Reali, et al. Simulation of transcatheter aortic valve implantation through patient-specific finite element analysis: Two clinical cases. J. Biomech. 47:2547\u20132555, 2014.","journal-title":"J. Biomech."},{"key":"427_CR58","doi-asserted-by":"publisher","first-page":"121010","DOI":"10.1115\/1.4005476","volume":"133","author":"S Morlacchi","year":"2011","unstructured":"Morlacchi, S., C. Chiastra, D. Gastaldi, G. Pennati, G. Dubini, and F. Migliavacca. Sequential structural and fluid dynamic numerical simulations of a stented bifurcated coronary artery. J. Biomech. Eng. 133:121010, 2011.","journal-title":"J. Biomech. Eng."},{"key":"427_CR59","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1007\/s10439-012-0694-1","volume":"41","author":"J Mummert","year":"2013","unstructured":"Mummert, J., E. Sirois, and W. Sun. Quantification of biomechanical interaction of transcatheter aortic valve stent deployed in porcine and ovine hearts. Ann. Biomed. Eng. 41:577\u2013586, 2013.","journal-title":"Ann. Biomed. Eng."},{"key":"427_CR60","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/0045-7825(74)90032-2","volume":"4","author":"JC Nagtegaal","year":"1974","unstructured":"Nagtegaal, J. C., D. M. Parks, and J. R. Rice. On numerically accurate finite element solutions in the fully plastic range. Comput. Methods Appl. Mech. Eng. 4:153\u2013177, 1974.","journal-title":"Comput. Methods Appl. Mech. Eng."},{"key":"427_CR61","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1016\/j.compbiomed.2015.12.001","volume":"69","author":"EA Ovcharenko","year":"2016","unstructured":"Ovcharenko, E. A., K. U. Klyshnikov, A. E. Yuzhalin, G. V. Savrasov, A. N. Kokov, A. V. Batranin, et al. Modeling of transcatheter aortic valve replacement: patient specific vs general approaches based on finite element analysis. Comput. Biol. Med. 69:29\u201336, 2016.","journal-title":"Comput. Biol. Med."},{"key":"427_CR62","doi-asserted-by":"publisher","first-page":"1029","DOI":"10.1002\/1097-0207(20001120)49:8<1029::AID-NME990>3.0.CO;2-3","volume":"49","author":"MA Puso","year":"2000","unstructured":"Puso, M. A. A highly efficient enhanced assumed strain physically stabilized hexahedral element. Int. J. Numer. Methods Eng. 49:1029\u20131064, 2000.","journal-title":"Int. J. Numer. Methods Eng."},{"key":"427_CR63","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.1056\/NEJMoa1700456","volume":"376","author":"MJ Reardon","year":"2017","unstructured":"Reardon, M. J., N. M. Van Mieghem, J. J. Popma, N. S. Kleiman, L. S\u00f8ndergaard, M. Mumtaz, et al. Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients. N. Engl. J. Med. 376:1321\u20131331, 2017.","journal-title":"N. Engl. J. Med."},{"key":"427_CR64","doi-asserted-by":"publisher","first-page":"694","DOI":"10.1007\/s10439-012-0712-3","volume":"41","author":"F Riveros","year":"2013","unstructured":"Riveros, F., S. Chandra, E. A. Finol, T. C. Gasser, and J. F. Rodriguez. A pull-back algorithm to determine the unloaded vascular geometry in anisotropic hyperelastic AAA passive mechanics. Ann. Biomed. Eng. 41:694\u2013708, 2013.","journal-title":"Ann. Biomed. Eng."},{"key":"427_CR65","doi-asserted-by":"publisher","first-page":"e005344","DOI":"10.1161\/CIRCINTERVENTIONS.117.005344","volume":"11","author":"G Rocatello","year":"2018","unstructured":"Rocatello, G., N. El Faquir, G. De Santis, F. Iannaccone, J. Bosmans, O. De Backer, et al. Patient-specific computer simulation to elucidate the role of contact pressure in the development of new conduction abnormalities after catheter-based implantation of a self-expanding aortic valve. Circ. Cardiovasc. Interv. 11:e005344, 2018.","journal-title":"Circ. Cardiovasc. Interv."},{"key":"427_CR66","doi-asserted-by":"crossref","unstructured":"Russ C, Hopf R, Hirsch S, Sundermann S, Falk V, Szekely G, et al. Simulation of transcatheter aortic valve implantation under consideration of leaflet calcification. In: 2013 35th Annu Int Conf IEEE Eng Med Biol Soc. 2013. pp. 711\u2013714.","DOI":"10.1109\/EMBC.2013.6609599"},{"key":"427_CR67","doi-asserted-by":"publisher","first-page":"1706","DOI":"10.4244\/EIJ-D-16-00237","volume":"12","author":"T Sch\u00e4fer","year":"2017","unstructured":"Sch\u00e4fer, T., C. Doose, B. Fujita, M. Utzenrath, S. Egron, C. Schmitz, et al. Preclinical determination of the best functional position for transcatheter heart valves implanted in rapid deployment bioprostheses. EuroIntervention. 12:1706\u20131714, 2017.","journal-title":"EuroIntervention."},{"key":"427_CR68","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1016\/j.jacc.2014.04.033","volume":"64","author":"GCM Siontis","year":"2014","unstructured":"Siontis, G. C. M., P. J\u00fcni, T. Pilgrim, S. Stortecky, L. B\u00fcllesfeld, B. Meier, et al. Predictors of permanent pacemaker implantation in patients with severe aortic stenosis undergoing TAVR: a meta-analysis. J. Am. Coll. Cardiol. 64:129\u2013140, 2014.","journal-title":"J. Am. Coll. Cardiol."},{"key":"427_CR69","doi-asserted-by":"publisher","first-page":"E141","DOI":"10.1111\/aor.13107","volume":"42","author":"E Sirois","year":"2018","unstructured":"Sirois, E., W. Mao, K. Li, J. Calderan, and W. Sun. Simulated transcatheter aortic valve flow: implications of elliptical deployment and under-expansion at the aortic annulus. Artif. Org. 42:E141\u2013E152, 2018.","journal-title":"Artif. Org."},{"key":"427_CR70","doi-asserted-by":"publisher","first-page":"2187","DOI":"10.1056\/NEJMoa1103510","volume":"364","author":"CR Smith","year":"2011","unstructured":"Smith, C. R., M. B. Leon, M. J. Mack, D. C. Miller, J. W. Moses, L. G. Svensson, et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N. Engl. J. Med. 364:2187\u20132198, 2011.","journal-title":"N. Engl. J. Med."},{"key":"427_CR71","doi-asserted-by":"publisher","first-page":"166","DOI":"10.4244\/EIJ-D-17-00719","volume":"14","author":"M Stoller","year":"2018","unstructured":"Stoller, M., S. Gloekler, R. Zbinden, D. Tueller, F. Eberli, S. Windecker, et al. Left ventricular afterload reduction by transcatheter aortic valve implantation in severe aortic stenosis and its prompt effects on comprehensive coronary haemodynamics. EuroIntervention. 14:166\u2013173, 2018.","journal-title":"EuroIntervention."},{"key":"427_CR72","doi-asserted-by":"publisher","first-page":"2520","DOI":"10.1016\/j.jbiomech.2016.03.036","volume":"49","author":"F Sturla","year":"2016","unstructured":"Sturla, F., M. Ronzoni, M. Vitali, A. Dimasi, R. Vismara, G. Preston-Maher, et al. Impact of different aortic valve calcification patterns on the outcome of transcatheter aortic valve implantation: a finite element study. J. Biomech. 49:2520\u20132530, 2016.","journal-title":"J. Biomech."},{"key":"427_CR73","first-page":"37","volume":"13","author":"L Testa","year":"2018","unstructured":"Testa, L., and A. Latib. Assessing the risk of leaflet motion abnormality following transcatheter aortic valve implantation. Interv. Cardiol. Rev. 13:37\u201339, 2018.","journal-title":"Interv. Cardiol. Rev."},{"key":"427_CR74","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/j.medengphy.2012.04.009","volume":"35","author":"S Tzamtzis","year":"2013","unstructured":"Tzamtzis, S., J. Viquerat, J. Yap, M. J. Mullen, and G. Burriesci. Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI). Med. Eng. Phys. 35:125\u2013130, 2013.","journal-title":"Med. Eng. Phys."},{"key":"427_CR75","doi-asserted-by":"publisher","first-page":"751","DOI":"10.1016\/j.athoracsur.2017.02.052","volume":"104","author":"K Vahidkhah","year":"2017","unstructured":"Vahidkhah, K., S. Javani, M. Abbasi, P. N. Azadani, A. Tandar, D. Dvir, et al. Blood stasis on transcatheter valve leaflets and implications for valve-in-valve leaflet thrombosis. Ann. Thorac. Surg. 104:751\u2013759, 2017.","journal-title":"Ann. Thorac. Surg."},{"key":"427_CR76","doi-asserted-by":"publisher","first-page":"1324","DOI":"10.1016\/j.jbiomech.2005.03.003","volume":"39","author":"JP Vande Geest","year":"2006","unstructured":"Vande Geest, J. P., M. S. Sacks, and D. A. Vorp. The effects of aneurysm on the biaxial mechanical behavior of human abdominal aorta. J. Biomech. 39:1324\u20131334, 2006.","journal-title":"J. Biomech."},{"key":"427_CR77","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1007\/s12572-015-0139-9","volume":"8","author":"P Vy","year":"2016","unstructured":"Vy, P., V. Auffret, P. Badel, M. Rochette, H. Le Breton, P. Haigron, et al. Review of patient-specific simulations of transcatheter aortic valve implantation. Int. J. Adv. Eng. Sci. Appl. Math. 8:2\u201324, 2016.","journal-title":"Int. J. Adv. Eng. Sci. Appl. Math."},{"key":"427_CR78","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1007\/s10237-017-0962-y","volume":"17","author":"S Wald","year":"2018","unstructured":"Wald, S., A. Liberzon, and I. Avrahami. A numerical study of the hemodynamic effect of the aortic valve on coronary flow. Biomech. Model Mechanobiol. 17:319\u2013338, 2018.","journal-title":"Biomech. Model Mechanobiol."},{"key":"427_CR79","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1007\/s10237-014-0583-7","volume":"14","author":"Q Wang","year":"2015","unstructured":"Wang, Q., S. Kodali, C. Primiano, and W. Sun. Simulations of transcatheter aortic valve implantation: implications for aortic root rupture. Biomech. Model Mechanobiol. 14:29\u201338, 2015.","journal-title":"Biomech. Model Mechanobiol."},{"key":"427_CR80","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1007\/s13239-018-0349-y","volume":"9","author":"ZA Wei","year":"2018","unstructured":"Wei, Z. A., S. J. Sonntag, M. Toma, S. Singh-Gryzbon, and W. Sun. Computational Fluid dynamics assessment associated with transcatheter heart valve prostheses: a position paper of the ISO working group. Cardiovasc. Eng. Technol. 9:289\u2013299, 2018.","journal-title":"Cardiovasc. Eng. Technol."},{"key":"427_CR81","doi-asserted-by":"publisher","first-page":"590","DOI":"10.1007\/s10439-015-1429-x","volume":"44","author":"W Wu","year":"2016","unstructured":"Wu, W., D. Pott, B. Mazza, T. Sironi, E. Dordoni, C. Chiastra, et al. Fluid-structure interaction model of a percutaneous aortic valve: comparison with an in vitro test and feasibility study in a patient-specific case. Ann. Biomed. Eng. 44:590\u2013603, 2016.","journal-title":"Ann. Biomed. Eng."},{"key":"427_CR82","doi-asserted-by":"publisher","first-page":"773","DOI":"10.1016\/j.athoracsur.2017.01.064","volume":"104","author":"Y Xuan","year":"2017","unstructured":"Xuan, Y., K. Krishnan, J. Ye, D. Dvir, J. M. Guccione, L. Ge, et al. Stent and leaflet stresses in 29-mm second-generation balloon-expandable transcatheter aortic valve. Ann. Thorac. Surg. 104:773\u2013781, 2017.","journal-title":"Ann. Thorac. Surg."},{"key":"427_CR83","doi-asserted-by":"publisher","first-page":"e282","DOI":"10.4244\/EIJ-D-17-00875","volume":"14","author":"A-S Zenses","year":"2018","unstructured":"Zenses, A.-S., M. A. Evin, V. Stanov\u00e1, M.-A. Clavel, P. Barragan, J. Rod\u00e9s-Cabau, et al. Effect of size and position of self-expanding transcatheter valve on haemodynamics following valve-in-valve procedure in small surgical bioprostheses: an in vitro study. EuroIntervention. 14:e282\u2013e289, 2018.","journal-title":"EuroIntervention."}],"container-title":["Cardiovascular Engineering and Technology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s13239-019-00427-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s13239-019-00427-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s13239-019-00427-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,7,13]],"date-time":"2020-07-13T19:11:54Z","timestamp":1594667514000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s13239-019-00427-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7,15]]},"references-count":83,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2019,9]]}},"alternative-id":["427"],"URL":"https:\/\/doi.org\/10.1007\/s13239-019-00427-0","relation":{},"ISSN":["1869-408X","1869-4098"],"issn-type":[{"value":"1869-408X","type":"print"},{"value":"1869-4098","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,7,15]]},"assertion":[{"value":"14 March 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 July 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 July 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}