{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T18:50:08Z","timestamp":1778007008686,"version":"3.51.4"},"reference-count":160,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2020,3,4]],"date-time":"2020-03-04T00:00:00Z","timestamp":1583280000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,3,4]],"date-time":"2020-03-04T00:00:00Z","timestamp":1583280000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100004489","name":"Mitacs","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100004489","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Cardiovasc Eng Tech"],"published-print":{"date-parts":[[2020,6]]},"DOI":"10.1007\/s13239-020-00460-4","type":"journal-article","created":{"date-parts":[[2020,3,4]],"date-time":"2020-03-04T17:02:53Z","timestamp":1583341373000},"page":"229-253","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":35,"title":["Transcatheter Mitral Valve Replacement: State of the Art"],"prefix":"10.1007","volume":"11","author":[{"given":"Dylan","family":"Goode","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ruby","family":"Dhaliwal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2089-9167","authenticated-orcid":false,"given":"Hadi","family":"Mohammadi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,3,4]]},"reference":[{"key":"460_CR1","doi-asserted-by":"crossref","first-page":"W84","DOI":"10.4244\/EIJV11SWA26","volume":"11","author":"M Abdelghani","year":"2015","unstructured":"Abdelghani, M., et al. The Sino Medical AccuFit transcatheter mitral valve implantation system. EuroIntervention 11:W84\u2013W85, 2015.","journal-title":"EuroIntervention"},{"issue":"9","key":"460_CR2","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.1016\/j.jacc.2015.06.1322","volume":"66","author":"O Abdul-Jawad Altisent","year":"2015","unstructured":"Abdul-Jawad Altisent, O., et al. Initial experience of transcatheter mitral valve replacement with a novel transcatheter mitral valve: procedural and 6-month follow-up results. J. Am. Coll. Cardiol. 66(9):1011\u20131019, 2015.","journal-title":"J. Am. Coll. Cardiol."},{"key":"460_CR3","unstructured":"Affluent Medical SA. EPYGON. Affluent Medical SA [Online]. https:\/\/www.affluentmedical.com\/epygon-2\/. Accessed 21 Jun 2019."},{"key":"460_CR4","unstructured":"Ailawadi, G. Tendyne TMVR: attributes , challenges, clinical data. TVT, 2019 [Online]. https:\/\/www.tctmd.com\/slide\/tendyne-attributes-challenges-and-clinical-data-summit. Accessed 19 Jun 2019."},{"key":"460_CR5","doi-asserted-by":"crossref","unstructured":"Alharbi, Y., N. H. Lovell, J. Otton, D. Muller, A. Al Abed, and S. Dokos. Image-based fluid dynamics analysis of left ventricle outflow tract pressure gradient after deployment transcatheter mitral valve. In: Proceedings of Annual International Conference on IEEE Engineering in Medicine and Biology Society, EMBS, 2017, pp. 4223\u20134226.","DOI":"10.1109\/EMBC.2017.8037788"},{"issue":"6","key":"460_CR6","first-page":"712","volume":"59","author":"A Angelini","year":"1988","unstructured":"Angelini, A., S. Y. Ho, R. H. Anderson, M. J. Davies, and A. E. Becker. A histological study of the atrioventricular junction in hearts with normal and prolapsed leaflets of the mitral valve. BMJ Journals 59(6):712\u2013716, 1988.","journal-title":"BMJ Journals"},{"key":"460_CR7","unstructured":"Atlantic Pediatric Device Consortium. MitraCath\u2014a transcatheter heart valve replacement device. Atlantic Pediatric Device Consortium [Online]. http:\/\/atlanticpediatricdeviceconsortium.org\/mitracath-transcatheter-heart-valve-replacement-device. Accessed 21 Jun 2019."},{"key":"460_CR8","unstructured":"B3C Newswire. Polares Medical Closes a $25M financing to enter clinical validation. B3C Newswire, 2018 [Online]. https:\/\/www.b3cnewswire.com\/201807171807\/polares-medical-closes-a-25m-financing-to-enter-clinical-validation.html. Accessed 20 Jun 2019."},{"issue":"4","key":"460_CR9","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1002\/ccd.25928","volume":"86","author":"V Bapat","year":"2015","unstructured":"Bapat, V., F. Pirone, S. Kapetanakis, R. Rajani, and S. Niederer. Factors influencing left ventricular outflow tract obstruction following a mitral valve-in-valve or valve-in-ring procedure, part 1. Catheter. Cardiovasc. Interv. 86(4):747\u2013760, 2015.","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"460_CR10","doi-asserted-by":"crossref","first-page":"U120","DOI":"10.4244\/EIJV10SUA18","volume":"10","author":"V Bapat","year":"2014","unstructured":"Bapat, V., et al. Transcatheter mitral valve implantation (TMVI) using the Edwards FORTIS device. EuroIntervention 10:U120\u2013U128, 2014.","journal-title":"EuroIntervention"},{"issue":"1","key":"460_CR11","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.jacc.2017.10.061","volume":"71","author":"V Bapat","year":"2018","unstructured":"Bapat, V., et al. Early Experience With New Transcatheter Mitral Valve Replacement. J. Am. Coll. Cardiol. 71(1):12\u201321, 2018.","journal-title":"J. Am. Coll. Cardiol."},{"issue":"16","key":"460_CR12","doi-asserted-by":"crossref","first-page":"1662","DOI":"10.1016\/j.jcin.2017.06.046","volume":"10","author":"M Barbanti","year":"2017","unstructured":"Barbanti, M., et al. Transcatheter Mitral Valve Implantation Using the HighLife System. JACC Cardiovasc. Interv. 10(16):1662\u20131670, 2017.","journal-title":"JACC Cardiovasc. Interv."},{"key":"460_CR13","first-page":"10000","volume":"10000","author":"K Bartus","year":"2018","unstructured":"Bartus, K., B. Kapelak, A. Gackowski, and J. Gammie. Harpoon for degenerative MR : device and Updated Clinical Data. TCT 10000:10000, 2018.","journal-title":"TCT"},{"issue":"5","key":"460_CR14","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1111\/j.1540-8191.2007.00449.x","volume":"22","author":"D Berdajs","year":"2007","unstructured":"Berdajs, D., G. Z\u00fcnd, C. Camenisch, U. Schurr, M. I. Turina, and M. Genoni. Annulus fibrosus of the mitral valve: reality or myth. J. Card. Surg. 22(5):406\u2013409, 2007.","journal-title":"J. Card. Surg."},{"issue":"3","key":"460_CR15","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1161\/CIRCULATIONAHA.116.025260","volume":"135","author":"PB Bertrand","year":"2017","unstructured":"Bertrand, P. B., E. Schwammenthal, R. A. Levine, and P. M. Vandervoort. Exercise Dynamics in Secondary Mitral Regurgitation: pathophysiology and Therapeutic Implications. Circulation 135(3):297\u2013314, 2017.","journal-title":"Circulation"},{"issue":"63","key":"460_CR16","doi-asserted-by":"crossref","first-page":"1449","DOI":"10.1098\/rsif.2011.0041","volume":"8","author":"J Biasetti","year":"2011","unstructured":"Biasetti, J., F. Hussain, and T. Christian Gasser. Blood flow and coherent vortices in the normal and aneurysmatic aortas: a fluid dynamical approach to intraluminal thrombus formation. J. R. Soc. Interface 8(63):1449\u20131461, 2011.","journal-title":"J. R. Soc. Interface"},{"issue":"10","key":"460_CR17","doi-asserted-by":"crossref","first-page":"1191","DOI":"10.1016\/j.jcmg.2015.08.004","volume":"8","author":"P Blanke","year":"2015","unstructured":"Blanke, P., et al. Multimodality Imaging in the Context of Transcatheter Mitral Valve Replacement. JACC Cardiovasc. Imaging 8(10):1191\u20131208, 2015.","journal-title":"JACC Cardiovasc. Imaging"},{"issue":"4","key":"460_CR18","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1016\/j.jcmg.2016.01.005","volume":"10","author":"P Blanke","year":"2017","unstructured":"Blanke, P., et al. Predicting LVOT\u00a0Obstruction in Transcatheter Mitral Valve\u00a0Implantation: concept of the Neo-LVOT. JACC Cardiovasc. Imaging 10(4):482\u2013485, 2017.","journal-title":"JACC Cardiovasc. Imaging"},{"key":"460_CR19","unstructured":"Bloomberg. Company Overview of Endovalve, Inc. [Online]. https:\/\/www.bloomberg.com\/research\/stocks\/private\/snapshot.asp?privcapId=27694016. Accessed 18 Jun 2019."},{"issue":"2","key":"460_CR20","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1115\/1.429634","volume":"122","author":"D Bluestein","year":"2000","unstructured":"Bluestein, D., E. Rambod, and M. Gharib. Vortex Shedding as a mechanism for free emboli formation in mechanical heart valves. J. Biomech. Eng. 122(2):125\u2013134, 2000.","journal-title":"J. Biomech. Eng."},{"issue":"4","key":"460_CR21","doi-asserted-by":"crossref","first-page":"1475","DOI":"10.1016\/j.athoracsur.2012.10.023","volume":"95","author":"W Bothe","year":"2013","unstructured":"Bothe, W., D. C. Miller, and T. Doenst. Sizing for mitral annuloplasty: where does science stop and Voodoo begin? Ann. Thorac. Surg. 95(4):1475\u20131483, 2013.","journal-title":"Ann. Thorac. Surg."},{"key":"460_CR22","unstructured":"Buchbinder, M. MValve: design highlights and clinical update. TCT, 2016 [Online]. https:\/\/www.tctmd.com\/slide\/mvalve-design-highlights-and-clinical-update. Accessed 06 Jun 2019."},{"key":"460_CR23","unstructured":"Buchbinder, M. MValve: highlights and design update. TCT, 2017 [Online]. https:\/\/www.tctmd.com\/slide\/new-technology-update-mvalve. Accessed 06 Jun 2019."},{"key":"460_CR24","unstructured":"Business Wire. LivaNova Acquires Caisson Interventional, LLC. Business Wire, 2017 [Online]. https:\/\/www.businesswire.com\/news\/home\/20170502006845\/en\/LivaNova-Acquires-Caisson-Interventional-LLC. Accessed 15 May 2019."},{"key":"460_CR25","unstructured":"Cairns, E. Livanova\u2019s mitral valve steams ahead, but could be a distant third to market. Vantage, 2018 [Online]. https:\/\/www.evaluate.com\/vantage\/articles\/news\/snippets\/livanovas-mitral-valve-steams-ahead-could-be-distant-third-market. Accessed 15 May 2019."},{"key":"460_CR26","unstructured":"Cardiovalve. Cardiovalve Transfemoral Valve Replacement System, 2019 [Online]. http:\/\/www.cardiovalve.com\/. Accessed 30 Apr 2019."},{"key":"460_CR27","first-page":"10000","volume":"1000","author":"Cardiovascular News","year":"2017","unstructured":"Cardiovascular News. TAVI company Direct Flow Medical closes after failing to secure funding. Cardiovascular News 1000:10000, 2017.","journal-title":"Cardiovascular News"},{"issue":"May","key":"460_CR28","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1007\/s12055-017-0608-9","volume":"34","author":"A Cheung","year":"2018","unstructured":"Cheung, A. Transcatheter mitral valve replacement. Indian J. Thorac. Cardiovasc. Surg. 34(May):144\u2013150, 2018.","journal-title":"Indian J. Thorac. Cardiovasc. Surg."},{"issue":"17","key":"460_CR29","doi-asserted-by":"crossref","first-page":"1814","DOI":"10.1016\/j.jacc.2014.06.1208","volume":"64","author":"A Cheung","year":"2014","unstructured":"Cheung, A., et al. Short-term results of transapical transcatheter mitral valve implantation for mitral regurgitation. J. Am. Coll. Cardiol. 64(17):1814\u20131819, 2014.","journal-title":"J. Am. Coll. Cardiol."},{"key":"460_CR30","doi-asserted-by":"crossref","first-page":"U115","DOI":"10.4244\/EIJV10SUA17","volume":"10","author":"A Cheung","year":"2014","unstructured":"Cheung, A., et al. Transcatheter mitral valve implantation with Tiara bioprosthesis. EuroIntervention 10:U115\u2013U119, 2014.","journal-title":"EuroIntervention"},{"key":"460_CR31","unstructured":"ClinicalTrials.gov. AHEAD: European Feasibility Study of the Cardiovalve Transfemoral Mitral Valve System (AHEAD). U.S. National Library of Medicine, 2019 [Online]. https:\/\/clinicaltrials.gov\/ct2\/show\/NCT03339115. Accessed 30 Apr 2019."},{"key":"460_CR32","unstructured":"ClinicalTrials.gov. Cardiovascular outcomes assessment of the MitraClip percutaneous therapy for heart failure patients with functional mitral regurgitation (The COAPT trial) (COAPT). U.S. National Library of Medicine, 2018 [Online]. https:\/\/clinicaltrials.gov\/ct2\/show\/NCT01626079. Accessed 29 Jan 2020."},{"key":"460_CR33","unstructured":"ClinicalTrials.gov. Multicentre study of percutaneous mitral valve repair MitraClip Device in Patients With Severe Secondary Mitral Regurgitation (MITRA-FR). U.S. National Library of Medicine, 2018 [Online]. https:\/\/clinicaltrials.gov\/ct2\/show\/NCT01920698. Accessed 29 Jan 2020."},{"key":"460_CR34","unstructured":"ClinicalTrials.gov. Caisson Transcatheter Mitral Valve Replacement (TMVR) System Early Feasibility Study (PRELUDE). U.S. National Library of Medicine, 2019 [Online]. https:\/\/clinicaltrials.gov\/ct2\/show\/NCT02768402. Accessed: 15 May 2019."},{"key":"460_CR35","unstructured":"ClinicalTrials.gov. Caisson Transcatheter Mitral Valve Replacement (TMVR) System Early Feasibility Study (PRELUDE). U.S. National Library of Medicine, 2019 [Online]. https:\/\/clinicaltrials.gov\/ct2\/show\/NCT02768402. Accessed 15 May 2019."},{"key":"460_CR36","unstructured":"ClinicalTrials.gov. Cardiovalve Transfemoral Mitral Valve System (AHEAD),\u201d U.S. National Library of Medicine, 2019 [Online]. https:\/\/clinicaltrials.gov\/ct2\/show\/NCT03813524. Accessed 30 Apr 2019."},{"key":"460_CR37","unstructured":"ClinicalTrials.gov. Clinical trial to evaluate the safety of using the Tendyne Mitral valve system for the treatment of symptomatic mitral regurgitation (SUMMIT). U.S. National Library of Medicine, 2019 [Online]. https:\/\/clinicaltrials.gov\/ct2\/show\/NCT03433274. Accessed 03 May 2019."},{"key":"460_CR38","unstructured":"ClinicalTrials.gov. Edwards EVOQUE TMVR Early Feasibility Study. U.S. National Library of Medicine, 2019 [Online]. https:\/\/clinicaltrials.gov\/ct2\/show\/NCT02718001. Accessed 28 Apr 2019."},{"key":"460_CR39","unstructured":"ClinicalTrials.gov. HighLife\u2122 Transcatheter mitral valve replacement system study. U.S. National Library of Medicine, 2019 [Online]. https:\/\/clinicaltrials.gov\/ct2\/show\/NCT02974881. Accessed 15 May 2019]"},{"key":"460_CR40","unstructured":"ClinicalTrials.gov. Tiara Transcatheter Mitral Valve Replacement Study (TIARA-II). U.S. National Library of Medicine, 2019 [Online]. https:\/\/www.clinicaltrials.gov\/ct2\/show\/NCT03039855. Accessed 28 Apr 2019."},{"key":"460_CR41","unstructured":"ClinicalTrials.gov. Transcatheter Mitral Valve Replacement With the Medtronic Intrepid\u2122 TMVR system in patients with severe symptomatic mitral regurgitation (APOLLO). U.S. National Library of Medicine, 2019 [Online]. https:\/\/clinicaltrials.gov\/ct2\/show\/NCT03242642. Accessed 14 May 2019."},{"issue":"1","key":"460_CR42","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1136\/heartjnl-2014-307020","volume":"102","author":"S Coffey","year":"2016","unstructured":"Coffey, S., B. J. Cairns, and B. Iung. The modern epidemiology of heart valve disease. Heart 102(1):75\u201385, 2016.","journal-title":"Heart"},{"key":"460_CR43","unstructured":"Colli, A., and P. Fects. MEND: a versatile valve technology. TCT, 2018 [Online]. https:\/\/www.tctmd.com\/slide\/amend-ring-annuloplasty-system-device-procedure-and-updated-outcomes. Accessed 19 Jun 2019."},{"issue":"4","key":"460_CR44","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1097\/MAT.0b013e3181db2476","volume":"56","author":"SC Corbett","year":"2010","unstructured":"Corbett, S. C., A. Ajdari, A. U. Coskun, and H. Nayeb-Hashemi. Effect of pulsatile blood flow on thrombosis potential with a step wall transition. ASAIO J. 56(4):290\u2013295, 2010.","journal-title":"ASAIO J."},{"issue":"3","key":"460_CR45","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1161\/CIRCINTERVENTIONS.114.001607","volume":"7","author":"O De Backer","year":"2014","unstructured":"De Backer, O., et al. Percutaneous transcatheter mitral valve replacement: an overview of devices in preclinical and early clinical evaluation. Circ. Cardiovasc. Interv. 7(3):400\u2013409, 2014.","journal-title":"Circ. Cardiovasc. Interv."},{"key":"460_CR46","unstructured":"Denti, P. SATURN PROJECT: a solid approach to MV transcatheter replacement. Mitral Valve Meeting, 2018 [Online]. https:\/\/www.innovheart.com\/wp-content\/uploads\/2018\/02\/Saturn-Project-A-solid-approach-to-MV-transcatheter-replacement-PDenti-20180226.pdf. Accessed 14 Jun 2019."},{"key":"460_CR47","unstructured":"Dr. Wang\u2019s Clinic. The Mitracath System: transcatheter mitral valve replacement system. Dr. Wang\u2019s Clinic, 2012 [Online]. http:\/\/wangyulin.weebly.com\/blog\/category\/news. Accessed 21 Jun 2019."},{"key":"460_CR48","unstructured":"Edwards Lifescience. Edwards pauses enrollment in early stage mitral program. Edwards Lifescience, 2015 [Online]. https:\/\/www.edwards.com\/ns20150519A. Accessed: 08 Jun 2019."},{"issue":"1","key":"460_CR49","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s10439-007-9398-3","volume":"36","author":"AM Fallon","year":"2008","unstructured":"Fallon, A. M., L. P. Dasi, U. M. Marzec, S. R. Hanson, and A. P. Yoganathan. Procoagulant properties of flow fields in stenotic and expansive orifices. Ann. Biomed. Eng. 36(1):1\u201313, 2008.","journal-title":"Ann. Biomed. Eng."},{"key":"460_CR50","unstructured":"Fam, N. P. PASCAL system for transcatheter mitral leaflet repair: initial experience and outcomes University of Toronto. TCT, 2018 [Online]. https:\/\/www.tctmd.com\/slide\/pascal-system-transcatheter-mitral-leaflet-repair-initial-experience-and-outcomes. Accessed 08 Jun 2019."},{"key":"460_CR51","unstructured":"Fattouch, K. Neochord for degenerative MR: device, data synthesis, and pivotal clinical trial progress. TCT, 2018 [Online]. https:\/\/www.tctmd.com\/slide\/neochord-degenerative-mr-device-data-synthesis-and-pivotal-clinical-trial-progress. Accessed 08 Jun 2019."},{"key":"460_CR52","unstructured":"FDA. FDA approves new indication for valve repair device to treat certain heart failure patients with mitral regurgitation. FDA, 2019 [Online]. https:\/\/www.fda.gov\/news-events\/press-announcements\/fda-approves-new-indication-valve-repair-device-treat-certain-heart-failure-patients-mitral. Accessed 06 Jun 2019."},{"key":"460_CR53","unstructured":"Feher, J. Chapter 5.4: the heart as a pump. In Quantitative Human Physiology, Amsterdam: Elsevier, 2012, pp. 446\u2013454."},{"key":"460_CR54","unstructured":"Fitzgerald, P. J. Emerging and investigational devices for mitral regurgitation; MitrAssist TMVR. TCT, 2014 [Online]. https:\/\/www.tctmd.com\/slide\/mitrassist-tmvr. Accessed 19 Jun 2019."},{"issue":"6","key":"460_CR55","doi-asserted-by":"crossref","first-page":"716","DOI":"10.21037\/acs.2018.11.01","volume":"7","author":"CD Flynn","year":"2018","unstructured":"Flynn, C. D., A. R. Wilson-Smith, and T. D. Yan. Novel mitral valve technologies\u2014transcatheter mitral valve implantation: a systematic review. Ann. Cardiothorac. Surg. 7(6):716\u2013723, 2018.","journal-title":"Ann. Cardiothorac. Surg."},{"issue":"5","key":"460_CR56","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1016\/j.echo.2009.02.008","volume":"22","author":"GP Foster","year":"2009","unstructured":"Foster, G. P., A. K. Dunn, S. Abraham, N. Ahmadi, and G. Sarraf. Accurate measurement of mitral annular dimensions by echocardiography: importance of correctly aligned imaging planes and anatomic landmarks. J. Am. Soc. Echocardiogr. 22(5):458\u2013463, 2009.","journal-title":"J. Am. Soc. Echocardiogr."},{"issue":"10","key":"460_CR57","doi-asserted-by":"crossref","first-page":"1555","DOI":"10.1016\/j.amjcard.2015.08.035","volume":"116","author":"GM Fr\u00f6hlich","year":"2015","unstructured":"Fr\u00f6hlich, G. M., et al. Comparative survival after transapical, direct aortic, and subclavian transcatheter aortic valve implantation (data from the UK TAVI Registry). Am. J. Cardiol. 116(10):1555\u20131559, 2015.","journal-title":"Am. J. Cardiol."},{"key":"460_CR58","unstructured":"G\u00e9n\u00e9reux, P. The AltaValve\u2122: attributes, challenges, and future programs. The Structural Heart Disease Summit, 2018 [Online]. https:\/\/www.tctmd.com\/slide\/altavalve-attributes-challenges-and-future-programs. Accessed 20 Jun 2019."},{"issue":"2","key":"460_CR59","doi-asserted-by":"crossref","first-page":"670","DOI":"10.1016\/j.athoracsur.2013.02.065","volume":"96","author":"MJ Gillespie","year":"2013","unstructured":"Gillespie, M. J., et al. Sutureless mitral valve replacement: initial steps toward a percutaneous procedure. Ann. Thorac. Surg. 96(2):670\u2013674, 2013.","journal-title":"Ann. Thorac. Surg."},{"issue":"2","key":"460_CR60","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/j.jacc.2013.08.723","volume":"63","author":"SS Goel","year":"2014","unstructured":"Goel, S. S., et al. Prevalence and outcomes of unoperated patients with severe symptomatic mitral regurgitation and heart failure: comprehensive analysis to determine the potential role of mitraclip for this unmet need. J. Am. Coll. Cardiol. 63(2):185\u2013186, 2014.","journal-title":"J. Am. Coll. Cardiol."},{"key":"460_CR61","unstructured":"Gorman Cardiovascular Research. Device & Startup Companies. Gorman Cardiovascular Research Group [Online]. http:\/\/www.gormanresearch.com\/device-startup\/. Accessed 18 Jun 2019."},{"key":"460_CR62","unstructured":"Gorman, J. H., R. C. Gorman, and M. J. Gillespie. Valve Prosthesis, US Patent 9,289,291, 2017."},{"key":"460_CR63","unstructured":"Granada, J. F. Cephea TMVR system: device description , clinical appraisal and development plans. TCT, 2017 [Online]. https:\/\/www.tctmd.com\/slide\/emerging-tmvr-1-cephea-device-description-critical-appraisal-and-development-plans. Accessed 14 Jun 2019."},{"issue":"2","key":"460_CR64","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1016\/j.jcmg.2018.11.006","volume":"12","author":"PA Grayburn","year":"2019","unstructured":"Grayburn, P. A., A. Sannino, and M. Packer. Proportionate and disproportionate functional mitral regurgitation: a new conceptual framework that reconciles the results of the MITRA-FR and COAPT Trials. JACC Cardiovasc. Imaging 12(2):353\u2013362, 2019.","journal-title":"JACC Cardiovasc. Imaging"},{"issue":"3","key":"460_CR65","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1002\/ccd.27054","volume":"92","author":"AB Greenbaum","year":"2018","unstructured":"Greenbaum, A. B., et al. Long or redundant leaflet complicating transcatheter mitral valve replacement: case vignettes that advocate for removal or reduction of the anterior mitral leaflet. Catheter. Cardiovasc. Interv. 92(3):627\u2013632, 2018.","journal-title":"Catheter. Cardiovasc. Interv."},{"issue":"4","key":"460_CR66","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1007\/s10237-005-0005-y","volume":"4","author":"M Grigioni","year":"2005","unstructured":"Grigioni, M., U. Morbiducci, G. D\u2019Avenio, G. Di Benedetto, and C. Del Gaudio. A novel formulation for blood trauma prediction by a modified power-law mathematical model. Biomech. Model. Mechanobiol. 4(4):249\u2013260, 2005.","journal-title":"Biomech. Model. Mechanobiol."},{"issue":"13","key":"460_CR67","doi-asserted-by":"crossref","first-page":"1361","DOI":"10.1016\/j.jcin.2016.04.022","volume":"9","author":"M Guerrero","year":"2016","unstructured":"Guerrero, M., et al. Transcatheter mitral valve replacement in native mitral valve disease with severe mitral annular calcification: results From the First Multicenter Global Registry. JACC Cardiovasc. Interv. 9(13):1361\u20131371, 2016.","journal-title":"JACC Cardiovasc. Interv."},{"key":"460_CR68","unstructured":"Hahn, R. T. NAVIGATE transcatheter tricuspid valve replacement\u2026 Early findings\u2014technology and clinical updates. TCT, 2018 [Online]. https:\/\/www.tctmd.com\/slide\/navigate-transcatheter-tricuspid-valve-replacement-early-findings-technology-and-clinical. Accessed 06 Jun 2019."},{"issue":"19","key":"460_CR69","doi-asserted-by":"crossref","first-page":"2059","DOI":"10.1016\/j.jacc.2016.08.010","volume":"68","author":"NC Hansson","year":"2016","unstructured":"Hansson, N. C., et al. Transcatheter aortic valve thrombosis: incidence, predisposing factors, and clinical implications. J. Am. Coll. Cardiol. 68(19):2059\u20132069, 2016.","journal-title":"J. Am. Coll. Cardiol."},{"key":"460_CR70","unstructured":"Hashimoto, S., et al. The effect of pulsatile shear flow on thrombus formation and hemolysis. In Annual International Conference of the IEEE Engineering in Medicine and Biology\u2014Proceedings, vol. 4, 2000, pp. 2461\u20132462."},{"key":"460_CR71","unstructured":"Herrmann, H. C. Transseptal TMVR: Edwards EVOQUE. TVT, 2019 [Online]. https:\/\/www.tctmd.com\/slide\/evoque-attributes-challenges-and-early-clinical-data. Accessed 19 Jun 2019."},{"issue":"5","key":"460_CR72","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1016\/S1001-6058(10)60156-4","volume":"23","author":"T Hong","year":"2011","unstructured":"Hong, T., and C. N. Kim. A numerical analysis of the blood flow around the Bileaflet Mechanical Heart Valves with different rotational implantation angles. J. Hydrodyn. 23(5):607\u2013614, 2011.","journal-title":"J. Hydrodyn."},{"key":"460_CR73","unstructured":"iBridge Network. MitraCath: Transcatheter Mitral Valve Replacement System. ibridge network, 2012 [Online]. https:\/\/www.ibridgenetwork.org\/#!\/profiles\/4005658529748\/innovations\/274\/. Accessed 21 Jun 2019."},{"issue":"3","key":"460_CR74","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1007\/s13239-018-0364-z","volume":"9","author":"R Iyer","year":"2018","unstructured":"Iyer, R., A. Chalekian, R. Lane, M. Evans, S. Yi, and J. Morris. Transcatheter mitral valve replacement: functional requirements for device design, bench-top, and pre-clinical evaluation. Cardiovasc. Eng. Technol. 9(3):301\u2013338, 2018.","journal-title":"Cardiovasc. Eng. Technol."},{"issue":"10","key":"460_CR75","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1093\/qjmed\/hcw084","volume":"109","author":"O Jolobe","year":"2016","unstructured":"Jolobe, O. Recognition of the distinction between primary and secondary mitral regurgitation is also important. QJM Int. J. Med. 109(10):699, 2016.","journal-title":"QJM Int. J. Med."},{"issue":"2","key":"460_CR76","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1007\/s10439-016-1775-3","volume":"45","author":"AH Khalighi","year":"2017","unstructured":"Khalighi, A. H., et al. Mitral valve chordae tendineae: topological and geometrical characterization. Ann. Biomed. Eng. 45(2):378\u2013393, 2017.","journal-title":"Ann. Biomed. Eng."},{"issue":"13","key":"460_CR77","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.1016\/j.jcin.2018.12.026","volume":"12","author":"JM Khan","year":"2019","unstructured":"Khan, J. M., U. Trivedi, A. Gomes, R. J. Lederman, and D. Hildick-Smith. \u2018Rescue\u2019 LAMPOON to treat transcatheter mitral valve replacement-associated left ventricular outflow tract obstruction. JACC Cardiovasc. Interv. 12(13):1283\u20131284, 2019.","journal-title":"JACC Cardiovasc. Interv."},{"issue":"19","key":"460_CR78","doi-asserted-by":"crossref","first-page":"2014","DOI":"10.1016\/j.jcin.2018.06.019","volume":"11","author":"JM Khan","year":"2018","unstructured":"Khan, J. M., et al. LAMPOON to facilitate tendyne transcatheter mitral valve replacement. JACC Cardiovasc. Interv. 11(19):2014\u20132017, 2018.","journal-title":"JACC Cardiovasc. Interv."},{"issue":"20","key":"460_CR79","doi-asserted-by":"crossref","first-page":"2521","DOI":"10.1016\/j.jacc.2019.02.076","volume":"73","author":"JM Khan","year":"2019","unstructured":"Khan, J. M., et al. Anterior leaflet laceration to prevent ventricular outflow tract obstruction during transcatheter mitral valve replacement. J. Am. Coll. Cardiol. 73(20):2521\u20132534, 2019.","journal-title":"J. Am. Coll. Cardiol."},{"key":"460_CR80","unstructured":"Kodali, S. Hemi-valve for mitral regurgitation (sutra): design concept and pre-clinical observations. TCT, 2018 [Online]. https:\/\/www.tctmd.com\/slide\/hemi-valve-mitral-regurgitation-sutra-design-concept-and-pre-clinical-observations. Accessed 19 Jun 2019."},{"key":"460_CR81","unstructured":"Kodali, S. Emerging mitral interventional technologies: Sutra Valve. TVT, 2019 [Online]. https:\/\/www.tctmd.com\/slide\/sutra. Accessed 29 Jun 2019."},{"issue":"10","key":"460_CR82","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.1007\/s10439-006-9194-5","volume":"34","author":"S Krishnan","year":"2006","unstructured":"Krishnan, S., H. S. Udaykumar, J. S. Marshall, and K. B. Chandran. Two-dimensional dynamic simulation of platelet activation during mechanical heart valve closure. Ann. Biomed. Eng. 34(10):1519\u20131534, 2006.","journal-title":"Ann. Biomed. Eng."},{"key":"460_CR83","unstructured":"Latib, A. Direct flow medical solutions for mitral valve replacement. CRT, 2016 [Online]. First-in-human implantation of a direct flow medical valve in a radiolucent mitral annuloplasty ring. Accessed 21 Jun 2019."},{"issue":"6","key":"460_CR84","doi-asserted-by":"crossref","first-page":"e105","DOI":"10.1016\/j.jcin.2015.01.024","volume":"8","author":"A Latib","year":"2015","unstructured":"Latib, A., et al. First-in-human implantation of a direct flow medical valve in a radiolucent mitral annuloplasty ring. JACC Cardiovasc. Interv. 8(6):e105\u2013e108, 2015.","journal-title":"JACC Cardiovasc. Interv."},{"key":"460_CR85","unstructured":"Leon, M. B. INTREPID: attributes, challenges, and clinical data (APOLLO). TVT, 2019 [Online]. https:\/\/www.tctmd.com\/slide\/intrepid-attributes-challenges-and-clinical-data-apollo. Accessed: 19 Jun 2019."},{"issue":"4","key":"460_CR86","doi-asserted-by":"crossref","first-page":"756","DOI":"10.1161\/01.CIR.75.4.756","volume":"75","author":"RA Levine","year":"1987","unstructured":"Levine, R. A., M. O. Triulzi, P. Harrigan, and A. E. Weyman. The relationship of mitral annular shape to the diagnosis of mitral valve prolapse. Circulation 75(4):756\u2013767, 1987.","journal-title":"Circulation"},{"issue":"6","key":"460_CR87","doi-asserted-by":"crossref","first-page":"1013","DOI":"10.1093\/ejcts\/ezy188","volume":"54","author":"K Loger","year":"2018","unstructured":"Loger, K., et al. Transcatheter mitral valve implantation: supra-annular and subvalvular fixation techniques. Eur. J. Cardiothorac. Surg. 54(6):1013\u20131021, 2018.","journal-title":"Eur. J. Cardiothorac. Surg."},{"issue":"9","key":"460_CR88","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.1016\/j.jcin.2014.06.007","volume":"7","author":"G Lutter","year":"2014","unstructured":"Lutter, G., et al. First-in-human off-pump transcatheter mitral valve replacement. JACC Cardiovasc. Interv. 7(9):1077\u20131078, 2014.","journal-title":"JACC Cardiovasc. Interv."},{"key":"460_CR89","unstructured":"Maisano, F. Cardiovalve: device attributes, implant procedure and early results. TCT, 2018 [Online]. https:\/\/www.tctmd.com\/slide\/cardiovalve-device-attributes-implant-procedure-and-early-results. Accessed 30 Apr 2019."},{"key":"460_CR90","unstructured":"Maisano, F. Cardiovalve: device attributes, implant procedure and early results. TVT, 2019 [Online]. https:\/\/www.tctmd.com\/slide\/cardiovalve-device-attributes-implant-procedure-and-early-results. Accessed 19 Aug 2019."},{"issue":"26","key":"460_CR91","doi-asserted-by":"crossref","first-page":"1651","DOI":"10.1093\/eurheartj\/ehv123","volume":"36","author":"F Maisano","year":"2015","unstructured":"Maisano, F., et al. The future of transcatheter mitral valve interventions: competitive or complementary role of repair vs. Replacement? Eur. Heart J. 36(26):1651\u20131659, 2015.","journal-title":"Eur. Heart J."},{"key":"460_CR92","doi-asserted-by":"publisher","DOI":"10.1155\/2015\/481245","author":"MS Maron","year":"2003","unstructured":"Maron, M. S., et al. Effect of left ventricular outflow tract obstruction on left atrial mechanics in hypertrophic cardiomyopathy. N. Engl. J. Med. 2003. https:\/\/doi.org\/10.1155\/2015\/481245.","journal-title":"N. Engl. J. Med."},{"issue":"10","key":"460_CR93","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1093\/ejechocard\/jeq153","volume":"11","author":"KP McCarthy","year":"2010","unstructured":"McCarthy, K. P., L. Ring, and B. S. Rana. Anatomy of the mitral valve: understanding the mitral valve complex in mitral regurgitation. Eur. J. Echocardiogr. 11(10):3\u20139, 2010.","journal-title":"Eur. J. Echocardiogr."},{"key":"460_CR94","unstructured":"Meerkin, D. The corona mitral valve replacement system: an innovative Modular solution to mitral regurgitation. TVT, 2017 [Online]. https:\/\/www.tctmd.com\/slide\/emerging-tmvr-4-corona-valve-amend-ring-device-description-critical-appraisal-and-development. Accessed 19 Jun 2019."},{"key":"460_CR95","unstructured":"Meerkin, D. The corona mitral valve replacement system: an innovative modular solution to mitral regurgitation. TCT, 2017 [Online]. https:\/\/www.tctmd.com\/slide\/emerging-tmvr-4-corona-valve-amend-ring-device-description-critical-appraisal-and-development. Accessed 19 Jun 2019."},{"key":"460_CR96","unstructured":"Meerkin, D. MEND: technology and clinical updates. The Structural Heart Disease Summit, 2018 [Online]. https:\/\/www.tctmd.com\/slide\/valcare-amend-progressing-technology-and-clinical-updates. Accessed 19 Jun 2019."},{"key":"460_CR97","unstructured":"Meerkin, D. AMEND: technology and clinical updates. TVT, 2019 [Online]. https:\/\/www.tctmd.com\/slide\/valcare-amend-technology-and-clinical-updates. Accessed 19 Jun 2019."},{"key":"460_CR98","unstructured":"Micro Interventional Devices Inc. Permavalve\u2014mitral valve replacement. Micro Interventional Devices, Inc. [Online]. https:\/\/www.microinterventional.com\/permavalve. Accessed 18 Jun 2019."},{"issue":"10","key":"460_CR99","doi-asserted-by":"crossref","first-page":"101009","DOI":"10.1115\/1.4028105","volume":"136","author":"B Min Yun","year":"2014","unstructured":"Min Yun, B., C. K. Aidun, and A. P. Yoganathan. Blood damage through a bileaflet mechanical heart valve: a quantitative computational study using a multiscale suspension flow solver. J. Biomech. Eng. 136(10):101009, 2014.","journal-title":"J. Biomech. Eng."},{"issue":"11","key":"460_CR100","doi-asserted-by":"crossref","first-page":"1358","DOI":"10.1093\/eurheartj\/ehm001","volume":"28","author":"M Mirabel","year":"2007","unstructured":"Mirabel, M., et al. What are the characteristics of patients with severe, symptomatic, mitral regurgitation who are denied surgery? Eur. Heart J. 28(11):1358\u20131365, 2007.","journal-title":"Eur. Heart J."},{"issue":"1484","key":"460_CR101","doi-asserted-by":"crossref","first-page":"1421","DOI":"10.1098\/rstb.2007.2125","volume":"362","author":"M Misfeld","year":"2007","unstructured":"Misfeld, M., and H. H. Sievers. Heart valve macro- and microstructure. Philos. Trans. R. Soc. B Biol. Sci. 362(1484):1421\u20131436, 2007.","journal-title":"Philos. Trans. R. Soc. B Biol. Sci."},{"key":"460_CR102","unstructured":"MitrAssist. The Product. MitrAssist [Online]. http:\/\/mitrassist.com\/product.asp. Accessed 18 Jun 2019."},{"key":"460_CR103","unstructured":"Modine, T. The Cephea TMVR: device attributes and implant procedure. TVT, 2019 [Online]. https:\/\/www.tctmd.com\/slide\/cephea-attributes-challenges-and-future-directions. Accessed 19 Jun 2019."},{"issue":"5","key":"460_CR104","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1177\/0954411919837302","volume":"233","author":"H Mohammadi","year":"2019","unstructured":"Mohammadi, H., D. Goode, G. Fradet, and K. Mequanint. Proposed percutaneous aortic valve prosthesis made of cryogel. Proc. Inst. Mech. Eng. Part H J. Eng. Med. 233(5):515\u2013524, 2019.","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"460_CR105","unstructured":"Muller , D. New technology update: Cephea TMVR system. TVT, 2017 [Online]. https:\/\/www.tctmd.com\/slide\/new-technology-update-cephea. Accessed 14 Jun 2019."},{"issue":"4","key":"460_CR106","doi-asserted-by":"crossref","first-page":"3115","DOI":"10.1016\/j.apm.2015.09.096","volume":"40","author":"WNWA Naim","year":"2015","unstructured":"Naim, W. N. W. A., et al. Prediction of thrombus formation using vortical structures presentation in Stanford type B aortic dissection: a preliminary study using CFD approach. Appl. Math. Model. 40(4):3115\u20133127, 2015.","journal-title":"Appl. Math. Model."},{"key":"460_CR107","unstructured":"Navigate Cardiac Structures Incorporated. First Navi patient at 8 months shows excellent mitral valve function and has returned to work, 2016 [Online]. https:\/\/www.navigatecsi.com\/announcement\/first-navi-patient-at-8-months-shows-excellent-mitral-valve-function-and-has-returned-to-work\/. Accessed 03 Jun 2019."},{"key":"460_CR108","unstructured":"Navigate Cardiac Structures Incorporated. NaviGate Cardiac Structures Inc. (\u2018NCSI\u2019) reports \u2018excellent valvular function\u2019 at 1-year follow-up of first patient to receive GATE tricuspid valved stent via transjugular access, 2018 [Online]. https:\/\/www.navigatecsi.com\/press-release\/navigate-cardiac-structures-inc-ncsi-reports-excellent-valvular-function-at-1-year-follow-up-of-first-patient-to-receive-gate-tricuspid-valved-stent-via\/. Accessed 03 Jun 2019."},{"key":"460_CR109","unstructured":"Navigate Cardiac Structures Incorporated. Strategy for the AtrioVentricular Valved Stent, 2019 [Online]. https:\/\/www.navigatecsi.com\/technology\/. Accessed 03 Jun 2019."},{"key":"460_CR110","unstructured":"Nietlispach, F. Accufit: The Sinomed solution for percutaneous mitral valve replacement. TCT, 2016."},{"issue":"9540","key":"460_CR111","doi-asserted-by":"crossref","first-page":"1005","DOI":"10.1016\/S0140-6736(06)69208-8","volume":"368","author":"VT Nkomo","year":"2006","unstructured":"Nkomo, V. T., J. M. Gardin, T. N. Skelton, J. S. Gottdiener, C. G. Scott, and M. Enriquez-Sarano. Burden of valvular heart diseases: a population-based study. Lancet 368(9540):1005\u20131011, 2006.","journal-title":"Lancet"},{"issue":"18","key":"460_CR112","doi-asserted-by":"crossref","first-page":"2019","DOI":"10.1016\/j.jacc.2015.09.015","volume":"66","author":"JM Paradis","year":"2015","unstructured":"Paradis, J. M., M. Del Trigo, R. Puri, and J. Rod\u00e9s-Cabau. Transcatheter valve-in-valve and valve-in-ring for treating aortic and mitral surgical prosthetic dysfunction. J. Am. Coll. Cardiol. 66(18):2019\u20132037, 2015.","journal-title":"J. Am. Coll. Cardiol."},{"issue":"1","key":"460_CR113","doi-asserted-by":"crossref","first-page":"e000976","DOI":"10.1136\/openhrt-2018-000976","volume":"6","author":"P Peruzzo","year":"2019","unstructured":"Peruzzo, P., F. M. Susin, A. Colli, and G. Burriesci. In vitro assessment of pacing as therapy for aortic regurgitation. Open Hear. 6(1):e000976, 2019.","journal-title":"Open Hear."},{"key":"460_CR114","unstructured":"Piazza, N. Transcatheter mitral valve replacement. TCT, 2018 [Online]. https:\/\/www.tctmd.com\/slide\/established-tmvr-5-highlife-device-description-strengths-and-weaknesses-and-updated-summary. Accessed 15 May 2019."},{"key":"460_CR115","unstructured":"Piazza, N. Transcatheter mitral valve replacement: HighLife. TVT, 2019 [Online]. https:\/\/www.tctmd.com\/slide\/highlife-attributes-challenges-and-clinical-data. Accessed 19 Jun 2019."},{"issue":"7","key":"460_CR116","doi-asserted-by":"crossref","first-page":"1034","DOI":"10.1161\/CIRCULATIONAHA.108.778886","volume":"119","author":"P Pibarot","year":"2009","unstructured":"Pibarot, P., and J. G. Dumesnil. Prosthetic heart valves: selection of the optimal prosthesis and long-term management. Circulation 119(7):1034\u20131048, 2009.","journal-title":"Circulation"},{"issue":"2","key":"460_CR117","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1007\/s10439-018-02154-4","volume":"47","author":"EL Pierce","year":"2019","unstructured":"Pierce, E. L., V. Sadri, B. Ncho, K. Kohli, S. Shah, and A. P. Yoganathan. Novel in vitro test systems and insights for transcatheter mitral valve design, part i: paravalvular leakage. Ann. Biomed. Eng. 47(2):381\u2013391, 2019.","journal-title":"Ann. Biomed. Eng."},{"issue":"2","key":"460_CR118","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1007\/s10439-018-02139-3","volume":"47","author":"EL Pierce","year":"2019","unstructured":"Pierce, E. L., et al. Novel In Vitro test systems and insights for transcatheter mitral valve design, part II: radial expansion forces. Ann. Biomed. Eng. 47(2):392\u2013402, 2019.","journal-title":"Ann. Biomed. Eng."},{"key":"460_CR119","unstructured":"Praz, F. Posterior leaflet augmentation & restoration. TVT, 2019 [Online]. https:\/\/www.tctmd.com\/slide\/polares. Accessed: 20 Jun 2019."},{"issue":"2","key":"460_CR120","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1007\/s13239-014-0203-9","volume":"6","author":"GL Preston-Maher","year":"2015","unstructured":"Preston-Maher, G. L., R. Torii, and G. Burriesci. A technical review of minimally invasive mitral valve replacements. Cardiovasc. Eng. Technol. 6(2):174\u2013184, 2015.","journal-title":"Cardiovasc. Eng. Technol."},{"issue":"3","key":"460_CR121","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1097\/imi.0000000000000278","volume":"11","author":"C Quarto","year":"2016","unstructured":"Quarto, C., et al. Transcatheter mitral valve implantation 30-day outcome of first-in-man experience with an apically tethered device. Innov. Technol. Tech. Cardiothorac. Vasc. Surg. 11(3):174\u2013178, 2016.","journal-title":"Innov. Technol. Tech. Cardiothorac. Vasc. Surg."},{"issue":"17","key":"460_CR122","doi-asserted-by":"crossref","first-page":"2175","DOI":"10.1016\/j.jacc.2017.02.045","volume":"69","author":"A Regueiro","year":"2017","unstructured":"Regueiro, A., J. F. Granada, F. Dagenais, and J. Rod\u00e9s-Cabau. Transcatheter mitral valve replacement: insights from early clinical experience and\u00a0future\u00a0challenges. J. Am. Coll. Cardiol. 69(17):2175\u20132192, 2017.","journal-title":"J. Am. Coll. Cardiol."},{"issue":"16","key":"460_CR123","doi-asserted-by":"crossref","first-page":"1671","DOI":"10.1016\/j.jcin.2017.05.032","volume":"10","author":"A Regueiro","year":"2017","unstructured":"Regueiro, A., et al. 2-Year outcomes after transcatheter mitral valve replacement. JACC Cardiovasc. Interv. 10(16):1671\u20131678, 2017.","journal-title":"JACC Cardiovasc. Interv."},{"issue":"19","key":"460_CR124","doi-asserted-by":"crossref","first-page":"2075","DOI":"10.1016\/j.jacc.2015.08.881","volume":"66","author":"HB Ribeiro","year":"2015","unstructured":"Ribeiro, H. B., et al. Predictors and impact of myocardial injury after transcatheter aortic valve replacement a multicenter registry. J. Am. Coll. Cardiol. 66(19):2075\u20132088, 2015.","journal-title":"J. Am. Coll. Cardiol."},{"key":"460_CR125","first-page":"10000","volume":"10000","author":"J Rod\u00e9s-Cabau","year":"2019","unstructured":"Rod\u00e9s-Cabau, J. AltaValve: attributes, Challenges and Future Programs. TVT 10000:10000, 2019.","journal-title":"TVT"},{"key":"460_CR126","unstructured":"Rod\u00e9s-Cabau, J. 4C Medical\u2019s AltaValve: the first-in-human experience. TCT, 2018 [Online]. https:\/\/www.tctmd.com\/slide\/4c-medicals-altavalve-first-human-experience. Accessed 20 Jun 2019."},{"issue":"8","key":"460_CR127","doi-asserted-by":"crossref","first-page":"1013","DOI":"10.1016\/j.jacc.2017.07.715","volume":"70","author":"T Rodriguez-Gabella","year":"2017","unstructured":"Rodriguez-Gabella, T., P. Voisine, R. Puri, P. Pibarot, and J. Rod\u00e9s-Cabau. Aortic bioprosthetic valve durability: incidence, mechanisms, predictors, and management of surgical and transcatheter valve degeneration. J. Am. Coll. Cardiol. 70(8):1013\u20131028, 2017.","journal-title":"J. Am. Coll. Cardiol."},{"key":"460_CR128","unstructured":"Rogers, J. H. Polares: technology and FIM update. TVT, 2019 [Online]. https:\/\/www.tctmd.com\/slide\/polares-technology-and-fim-update. Accessed 20 Jun 2019."},{"issue":"2","key":"460_CR129","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1016\/j.echo.2011.10.008","volume":"25","author":"C Rosendal","year":"2012","unstructured":"Rosendal, C., M. D. Hien, T. Bruckner, E. O. Martin, G. Szabo, and H. Rauch. Left ventricular outflow tract: intraoperative measurement and changes caused by mitral valve surgery. J. Am. Soc. Echocardiogr. 25(2):166\u2013172, 2012.","journal-title":"J. Am. Soc. Echocardiogr."},{"key":"460_CR130","unstructured":"Schofer, J. Direct flow medical TAVR system. TCT, 2012 [Online]. https:\/\/www.tctmd.com\/slide\/direct-flow-medical-tavr-system. Accessed 21 Jun 2019."},{"key":"460_CR131","unstructured":"Scorsin, M., and Pasquino, E. Pioneering physiological mitral prosthesis designed to treat mitral regurgitation and left ventricular function: Results of preclinical transcatheter implantation. TCT, 2018 [Online]. https:\/\/www.tctmd.com\/slide\/pioneering-physiological-mitral-prosthesis-designed-treat-mitral-regurgitation-and-left. Accessed 21 Jun 2019."},{"key":"460_CR132","unstructured":"Serruys, P. W. Accufit TMVR transapical mitral valve replacement system: a technical update. EuroPCR, 2016 [Online]. https:\/\/www.pcronline.com\/Cases-resources-images\/Resources\/Course-videos-slides\/2016\/Mitral-and-tricuspid. Accessed 28 May 2019."},{"issue":"18","key":"460_CR133","doi-asserted-by":"crossref","first-page":"B259","DOI":"10.1016\/j.jacc.2016.09.779","volume":"68","author":"P Serruys","year":"2016","unstructured":"Serruys, P., et al. TCT-637 The transapical AccuFit bioprosthesis for transcatheter mitral valve replacement. J. Am. Coll. Cardiol. 68(18):B259, 2016.","journal-title":"J. Am. Coll. Cardiol."},{"issue":"6","key":"460_CR134","doi-asserted-by":"crossref","first-page":"1279","DOI":"10.1007\/s10439-013-0758-x","volume":"41","author":"J Sheriff","year":"2013","unstructured":"Sheriff, J., J. S. Soares, M. Xenos, J. Jesty, and D. Bluestein. Evaluation of shear-induced platelet activation models under constant and dynamic shear stress loading conditions relevant to devices. Ann. Biomed. Eng. 41(6):1279\u20131296, 2013.","journal-title":"Ann. Biomed. Eng."},{"issue":"11","key":"460_CR135","doi-asserted-by":"crossref","first-page":"3295","DOI":"10.1007\/s10439-010-0086-3","volume":"38","author":"HA Simon","year":"2010","unstructured":"Simon, H. A., L. Ge, F. Sotiropoulos, and A. P. Yoganathan. Numerical investigation of the performance of three hinge designs of bileaflet mechanical heart valves. Ann. Biomed. Eng. 38(11):3295\u20133310, 2010.","journal-title":"Ann. Biomed. Eng."},{"issue":"4","key":"460_CR136","first-page":"50","volume":"12","author":"N Sodhi","year":"2018","unstructured":"Sodhi, N., and A. Zajarias. Status of transcatheter mitral valve replacement: an emerging frontier with unique anatomical, technical, and clinical challenges. Card. Interv. Today 12(4):50\u201353, 2018.","journal-title":"Card. Interv. Today"},{"issue":"6","key":"460_CR137","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1093\/ejcts\/ezu546","volume":"48","author":"L Sondergaard","year":"2015","unstructured":"Sondergaard, L., et al. Transcatheter mitral valve implantation via transapical approach: an early experience. Eur. J. Cardiothoracic Surg. 48(6):873\u2013878, 2015.","journal-title":"Eur. J. Cardiothoracic Surg."},{"issue":"7","key":"460_CR138","first-page":"e002135","volume":"8","author":"L S\u00f8ndergaard","year":"2015","unstructured":"S\u00f8ndergaard, L., et al. First-in-human case of transfemoral CardiAQ mitral valve implantation. Images Case Rep. Interv. Cardiol. 8(7):e002135, 2015.","journal-title":"Images Case Rep. Interv. Cardiol."},{"key":"460_CR139","unstructured":"Sorajja, P. MitraClip in the U.S.: latest TVT registry results. TCT, 2018 [Online]. https:\/\/www.tctmd.com\/slide\/mitraclip-us-latest-tvt-registry-results. Accessed 06 Jun 2019."},{"issue":"11","key":"460_CR140","doi-asserted-by":"crossref","first-page":"1250","DOI":"10.1016\/j.jacc.2018.12.066","volume":"73","author":"P Sorajja","year":"2019","unstructured":"Sorajja, P., et al. Initial feasibility study of a new transcatheter mitral prosthesis: the first 100 patients. J. Am. Coll. Cardiol. 73(11):1250\u20131260, 2019.","journal-title":"J. Am. Coll. Cardiol."},{"key":"460_CR141","unstructured":"Steven, B. Caisson Transeptal Valve. TVT, 2019 [Online]. https:\/\/www.tctmd.com\/slide\/caisson-program-attributes-challenges-and-early-clinical-data. Accessed 19 Jun 2019."},{"issue":"24","key":"460_CR142","doi-asserted-by":"crossref","first-page":"2307","DOI":"10.1056\/NEJMoa1806640","volume":"379","author":"GW Stone","year":"2018","unstructured":"Stone, G. W., et al. Transcatheter mitral-valve repair in patients with heart failure. N. Engl. J. Med. 379(24):2307\u20132318, 2018.","journal-title":"N. Engl. J. Med."},{"key":"460_CR143","unstructured":"Sun, W. Sutra: technology and development plan. TVT, 2019 [Online]. https:\/\/www.tctmd.com\/slide\/sutra-technology-and-development-plan. Accessed 19 Jun 2019."},{"issue":"8","key":"460_CR144","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1111\/j.1525-1594.2009.00782.x","volume":"33","author":"M Tamagawa","year":"2009","unstructured":"Tamagawa, M., H. Kaneda, M. Hiramoto, and S. Nagahama. Simulation of thrombus formation in shear flows using lattice boltzmann method. Artif. Organs 33(8):604\u2013610, 2009.","journal-title":"Artif. Organs"},{"key":"460_CR145","unstructured":"The Press Democrat. Direct Flow Medical in Santa Rosa shuts down, 250 people laid off. The Press Democrat, 2016 [Online]. https:\/\/www.pressdemocrat.com\/business\/6461514-181\/direct-flow-medical-shuts-down?artslide=1&sba=AAS. Accessed 21 Jun 2019."},{"issue":"9","key":"460_CR146","doi-asserted-by":"crossref","first-page":"947","DOI":"10.1016\/j.jcin.2014.06.002","volume":"7","author":"P Th\u00e9riault-Lauzier","year":"2014","unstructured":"Th\u00e9riault-Lauzier, P., et al. Fluoroscopic anatomy of left-sided heart structures for transcatheter interventions: insight from multislice computed tomography. JACC Cardiovasc. Interv. 7(9):947\u2013957, 2014.","journal-title":"JACC Cardiovasc. Interv."},{"key":"460_CR147","unstructured":"Thourani, V. H. Cardioband direct annuloplasty for functional MR: device , data synthesis, and pivotal clinical trial progress. TCT, 2018 [Online]. https:\/\/www.tctmd.com\/sites\/default\/files\/efs\/public\/2018-09\/6CF71612-A535-49CB-A504-EA71627C250F.pdf. Accessed 08 Jun 2019."},{"key":"460_CR148","unstructured":"Ticar, J. Mitral butterfly: evaluation of a novel device in porcine and human hearts. TVT, 2019 [Online]. https:\/\/www.tctmd.com\/slide\/mitral-butterfly-evaluation-novel-device-porcine-and-human-hearts. Accessed 10 Sep 2019."},{"issue":"5","key":"460_CR149","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1016\/j.jacc.2014.11.027","volume":"65","author":"M Urena","year":"2015","unstructured":"Urena, M., et al. Late cardiac death in patients undergoing transcatheter aortic valve replacement: incidence and predictors of advanced heart failure and sudden cardiac death. J. Am. Coll. Cardiol. 65(5):437\u2013448, 2015.","journal-title":"J. Am. Coll. Cardiol."},{"key":"460_CR150","unstructured":"Von Bardeleben, R. S. Carillon indirect annuloplasty for functional MR: device, data synthesis, clinical trial progress. TCT, 2018 [Online]. https:\/\/www.tctmd.com\/slide\/carillon-indirect-annuloplasty-functional-mr-device-data-synthesis-and-pivotal-clinical-trial. Accessed 08 Jun 2019."},{"issue":"2","key":"460_CR151","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1002\/ccd.27447","volume":"92","author":"DD Wang","year":"2018","unstructured":"Wang, D. D., et al. Validating a prediction modeling tool for left ventricular outflow tract (LVOT) obstruction after transcatheter mitral valve replacement (TMVR). Catheter. Cardiovasc. Interv. 92(2):379\u2013387, 2018.","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"460_CR152","unstructured":"Webb, J. Transcatheter mitral valve replacement with the SAPIEN M3. TVT, 2019 [Online]. https:\/\/www.tctmd.com\/slide\/m3-attributes-challenges-and-early-clinical-data. Accessed 19 Jun 2019."},{"issue":"11","key":"460_CR153","doi-asserted-by":"crossref","first-page":"1239","DOI":"10.1016\/j.jacc.2018.12.065","volume":"73","author":"JG Webb","year":"2019","unstructured":"Webb, J. G., et al. Percutaneous transcatheter mitral valve replacement: first-in-human experience with a new transseptal system. J. Am. Coll. Cardiol. 73(11):1239\u20131246, 2019.","journal-title":"J. Am. Coll. Cardiol."},{"key":"460_CR154","unstructured":"Wermers, J., and R. Torguson. SAPIEN M3 System\u2019s early results are \u2018encouraging\u2019 for treatment of mitral regurgitation, 2018 [Online]. http:\/\/www.crtonline.org\/news-detail\/sapien-m3-system-s-early-results-are-encouraging-t. Accessed 29 Apr 2019."},{"key":"460_CR155","unstructured":"Williams, M. Transfemoral TMVR: Caisson transcatheter mitral valve replacement. TCT, 2018 [Online]. https:\/\/www.tctmd.com\/slide\/caisson-device-attributes-implant-procedure-and-early-results. Accessed 15 May 2019."},{"issue":"5","key":"460_CR156","doi-asserted-by":"crossref","first-page":"1789","DOI":"10.1016\/j.athoracsur.2007.11.069","volume":"85","author":"Q Wu","year":"2008","unstructured":"Wu, Q., L. Zhang, and R. Zhu. Obstruction of Left ventricular outflow tract after mechanical mitral valve replacement. Ann. Thorac. Surg. 85(5):1789\u20131791, 2008.","journal-title":"Ann. Thorac. Surg."},{"issue":"12","key":"460_CR157","doi-asserted-by":"crossref","first-page":"2400","DOI":"10.1016\/j.jbiomech.2010.04.020","volume":"43","author":"M Xenos","year":"2010","unstructured":"Xenos, M., et al. Device Thrombogenicity Emulator (DTE)\u2014design optimization methodology for cardiovascular devices: a study in two bileaflet MHV designs. J. Biomech. 43(12):2400\u20132409, 2010.","journal-title":"J. Biomech."},{"key":"460_CR158","volume-title":"The Biomedical Engineering Handbook","author":"AP Yoganathan","year":"2000","unstructured":"Yoganathan, A. P. Cardiac valve prosthesis. In: The Biomedical Engineering Handbook2nd, edited by J. D. Bronzino. Boca Raton: CRC Press, 2000.","edition":"2"},{"issue":"2","key":"460_CR159","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1016\/j.jcin.2018.12.001","volume":"12","author":"SH Yoon","year":"2019","unstructured":"Yoon, S. H., et al. Predictors of left ventricular outflow tract obstruction after transcatheter mitral valve replacement. JACC Cardiovasc. Interv. 12(2):182\u2013193, 2019.","journal-title":"JACC Cardiovasc. Interv."},{"key":"460_CR160","unstructured":"Zovighian, B. J. Transcatheter mitral & tricuspid therapies. Edwards Lifesciences, 2018 [Online]. Available: http:\/\/ir.edwards.com\/static-files\/76ed84fa-adc1-4c22-aa30-cd405801e1b9. Accessed 29 Apr 2019."}],"container-title":["Cardiovascular Engineering and Technology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s13239-020-00460-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s13239-020-00460-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s13239-020-00460-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,4]],"date-time":"2021-03-04T00:50:09Z","timestamp":1614819009000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s13239-020-00460-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,3,4]]},"references-count":160,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020,6]]}},"alternative-id":["460"],"URL":"https:\/\/doi.org\/10.1007\/s13239-020-00460-4","relation":{},"ISSN":["1869-408X","1869-4098"],"issn-type":[{"value":"1869-408X","type":"print"},{"value":"1869-4098","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,3,4]]},"assertion":[{"value":"11 July 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 February 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 March 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}