{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T04:13:05Z","timestamp":1788927185090,"version":"build-2803163510"},"reference-count":55,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2021,3,8]],"date-time":"2021-03-08T00:00:00Z","timestamp":1615161600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2021,3,8]],"date-time":"2021-03-08T00:00:00Z","timestamp":1615161600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100000038","name":"U.S. Food and Drug Administration","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000038","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Cardiovasc Eng Tech"],"published-print":{"date-parts":[[2021,6]]},"DOI":"10.1007\/s13239-021-00524-z","type":"journal-article","created":{"date-parts":[[2021,3,8]],"date-time":"2021-03-08T16:03:01Z","timestamp":1615219381000},"page":"339-352","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["In Vitro Clot Trapping Efficiency of the FDA Generic Inferior Vena Cava Filter in an Anatomical Model: An Experimental Fluid\u2013Structure Interaction Benchmark"],"prefix":"10.1007","volume":"12","author":[{"given":"J. M.","family":"Riley","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"N. S.","family":"Price","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H. M.","family":"Saaid","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B. C.","family":"Good","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K. I.","family":"Aycock","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B. A.","family":"Craven","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9029-5217","authenticated-orcid":false,"given":"K. B.","family":"Manning","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,3,8]]},"reference":[{"key":"524_CR1","volume-title":"Assessing Credibility of Computational Modeling Through Verification and Validation: Application to Medical Devices","author":"ASME V&V 40-2018","year":"2018","unstructured":"ASME V&V 40-2018. Assessing Credibility of Computational Modeling Through Verification and Validation: Application to Medical Devices. New York: American Society of Mechanical Engineers, 2018."},{"issue":"12","key":"524_CR2","doi-asserted-by":"publisher","first-page":"3568","DOI":"10.1007\/s10439-016-1663-x","volume":"44","author":"KI Aycock","year":"2016","unstructured":"Aycock, K. I., R. L. Campbell, F. C. Lynch, K. B. Manning, and B. A. Craven. The importance of hemorheology and patient anatomy on the hemodynamics in the inferior vena cava. Ann. Biomed. Eng. 44(12):3568\u20133582, 2016.","journal-title":"Ann. Biomed. Eng."},{"key":"524_CR3","doi-asserted-by":"publisher","first-page":"1957","DOI":"10.1007\/s10237-017-0931-5","volume":"16","author":"KI Aycock","year":"2017","unstructured":"Aycock, K. I., R. L. Campbell, F. C. Lynch, K. B. Manning, and B. A. Craven. Computational predictions of the embolus-trapping performance of an IVC filter in patient-specific and idealized IVC geometries. Biomech. Model. Mechanobiol. 16:1957\u20131969, 2017.","journal-title":"Biomech. Model. Mechanobiol."},{"key":"524_CR4","doi-asserted-by":"publisher","first-page":"851","DOI":"10.1007\/s10237-016-0857-3","volume":"16","author":"KI Aycock","year":"2017","unstructured":"Aycock, K. I., R. L. Campbell, K. B. Manning, and B. A. Craven. A resolved two-way coupled CFD\/6-DOF approach for predicting embolus transport and the embolus-trapping efficiency of IVC filters. Biomech. Model. Mechanobiol. 16:851\u2013869, 2017.","journal-title":"Biomech. Model. Mechanobiol."},{"issue":"8","key":"524_CR5","doi-asserted-by":"publisher","first-page":"081003","DOI":"10.1115\/1.4027612","volume":"136","author":"KI Aycock","year":"2014","unstructured":"Aycock, K. I., R. L. Campbell, K. B. Manning, S. P. Sastry, S. M. Shontz, F. C. Lynch, and B. A. Craven. A computational method for predicting inferior vena cava filter performance on a patient-specific basis. J. Biomech. Eng. 136(8):081003, 2014.","journal-title":"J. Biomech. Eng."},{"issue":"11","key":"524_CR6","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1007\/s00348-017-2403-1","volume":"58","author":"KI Aycock","year":"2017","unstructured":"Aycock, K. I., P. Hariharan, and B. A. Craven. Particle image velocimetry measurements in an anatomical vascular model fabricated using inkjet 3D printing. Exp. Fluids 58(11):154, 2017.","journal-title":"Exp. Fluids"},{"key":"524_CR7","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1214\/ss\/1009213286","volume":"16","author":"LD Brown","year":"2001","unstructured":"Brown, L. D., T. T. Cat, and A. DasGupta. Interval estimation for a proportion. Stat. Sci. 16:101\u2013133, 2001.","journal-title":"Stat. Sci."},{"key":"524_CR8","doi-asserted-by":"publisher","first-page":"1161","DOI":"10.1152\/ajpheart.00641.2002","volume":"284","author":"CP Cheng","year":"2003","unstructured":"Cheng, C. P., R. J. Herfkens, and C. A. Taylor. Inferior vena caval hemodynamics quantified in vivo at rest and during cycling exercise using magnetic resonance imaging. Am. J. Physol. Heart Circ. 284:1161\u20131167, 2003.","journal-title":"Am. J. Physol. Heart Circ."},{"issue":"4","key":"524_CR9","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1007\/s13239-018-00392-0","volume":"9","author":"BA Craven","year":"2018","unstructured":"Craven, B. A., K. I. Aycock, and K. B. Manning. Steady flow in a patient-averaged inferior vena cava: Part II\u2014computational fluid dynamics verification and validation. Cardiovasc. Eng. Techn. 9(4):654\u2013673, 2018.","journal-title":"Cardiovasc. Eng. Techn."},{"key":"524_CR10","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1016\/j.compfluid.2014.04.020","volume":"99","author":"G De Nayer","year":"2014","unstructured":"De Nayer, G., A. Kalmbach, M. Breuer, S. Sicklinger, and R. W\u00fcchner. Flow past a cylinder with a flexible splitter plate: A complementary experimental\u2013numerical investigation and a new FSI test case (FSI-PfS-1a). Comput. Fluids. 99:18\u201343, 2014.","journal-title":"Comput. Fluids."},{"issue":"4","key":"524_CR11","first-page":"472","volume":"4","author":"SJ Dria","year":"2016","unstructured":"Dria, S. J., and M. D. Eggers. In vitro evaluation of clot capture efficiency of an absorbable vena cava filter. J. Vasc. Surg-Venous L. 4(4):472\u2013478, 2016.","journal-title":"J. Vasc. Surg-Venous L."},{"issue":"4","key":"524_CR12","doi-asserted-by":"publisher","first-page":"041014","DOI":"10.1115\/1.4046751","volume":"142","author":"BR Elbing","year":"2020","unstructured":"Elbing, B. R., S. D. Young, M. L. Jonson, R. L. Campbell, B. A. Craven, R. F. Kunz, and K. L. Koudela. Experimental characterization of high-amplitude fluid\u2013structure interaction of a flexible hydrofoil at high Reynolds number. J. Vib. Acoust 142(4):041014, 2020.","journal-title":"J. Vib. Acoust"},{"key":"524_CR13","unstructured":"FDA. (1999) Guidance for industry and FDA staff: Guidance for cardiovascular intravascular filter 510(k) submissions. https:\/\/www.fda.gov\/downloads\/MedicalDevices\/DeviceRegulationandGuidance\/GuidanceDocuments\/ucm073777.pdf."},{"key":"524_CR14","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4757-2257-4","volume-title":"Biomechanics: Mechanical Properties of Living Tissues","author":"YC Fung","year":"1993","unstructured":"Fung, Y. C., and S. C. Cowin. Biomechanics: Mechanical Properties of Living Tissues (2nd ed.). New York: Springer, 1993.","edition":"2"},{"key":"524_CR15","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1007\/s13239-018-00390-2","volume":"9","author":"MB Gallagher","year":"2018","unstructured":"Gallagher, M. B., K. I. Aycock, B. A. Craven, and K. B. Manning. Steady flow in a patient-averaged inferior vena cava\u2014Part I: Particle image velocimetry measurements at rest and exercise conditions. Cardiovasc. Eng. Techn. 9:641\u2013653, 2018.","journal-title":"Cardiovasc. Eng. Techn."},{"issue":"6","key":"524_CR16","doi-asserted-by":"publisher","first-page":"829","DOI":"10.1016\/j.jvir.2011.02.018","volume":"22","author":"X Gao","year":"2010","unstructured":"Gao, X., J. Zhang, B. Chen, H. Yu, J. Li, S. Zhang, Z. Feng, L. Ye, and J. Han. A new self-convertible inferior vena cava filter: Experimental in-vitro and in-vivo evaluation. J. Vasc. Interv. Radiol. 22(6):829\u2013834, 2010.","journal-title":"J. Vasc. Interv. Radiol."},{"issue":"1","key":"524_CR17","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.jfluidstructs.2010.09.004","volume":"27","author":"JP Gomes","year":"2011","unstructured":"Gomes, J. P., S. Yigit, H. Lienhart, and M. Sch\u00e4fer. Experimental and numerical study on a laminar fluid\u2013structure interaction reference test case. J. Fluid. Struct. 27(1):43\u201361, 2011.","journal-title":"J. Fluid. Struct."},{"issue":"5","key":"524_CR18","doi-asserted-by":"publisher","first-page":"632","DOI":"10.1055\/s-2005-858109","volume":"177","author":"RW G\u00fcnther","year":"2005","unstructured":"G\u00fcnther, R. W., J. Neuerburg, A. Mossdorf, J. Pfeffer, R. H\u00f8j, A. M\u00f8lgaard-Nielsen, A. B\u00fccker, and T. Schmitz-Rode. New optional IVC filter for percutaneous retrieval - In vitro evaluation of embolus capturing efficiency. Rofo. 177(5):632\u2013636, 2005.","journal-title":"Rofo."},{"issue":"6","key":"524_CR19","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1016\/S1051-0443(94)71627-4","volume":"5","author":"FD Hammer","year":"1994","unstructured":"Hammer, F. D., H. P. Rousseau, F. G. Joffre, B. P. Sentenac, T. Tran-Van, and R. P. Barthelemy. In vitro evaluation of vena cava filters. J. Vasc. Interv. Radiol. 5(6):869\u2013876, 1994.","journal-title":"J. Vasc. Interv. Radiol."},{"issue":"9","key":"524_CR20","doi-asserted-by":"publisher","first-page":"e2848","DOI":"10.1002\/cnm.2848","volume":"33","author":"A Hessenthaler","year":"2017","unstructured":"Hessenthaler, A., N. R. Gaddum, O. Holub, R. Sinkus, O. R\u00f6hrle, and D. Nordsletten. Experiment for validation of fluid\u2013structure interaction models and algorithms. Int. J. Numer. Method. Biomed. Eng. 33(9):e2848, 2017.","journal-title":"Int. J. Numer. Method. Biomed. Eng."},{"issue":"3","key":"524_CR21","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1016\/S0997-7538(01)01206-2","volume":"21","author":"GA Holzapfel","year":"2002","unstructured":"Holzapfel, G. A., T. C. Gasser, and M. Stadler. A structural model for the viscoelastic behavior of arterial walls: Continuum formulation and finite element analysis. Eur. J. Mech. A 21(3):441\u2013463, 2002.","journal-title":"Eur. J. Mech. A"},{"issue":"9","key":"524_CR22","doi-asserted-by":"publisher","first-page":"620","DOI":"10.1016\/S1076-6332(98)80298-5","volume":"5","author":"J Hosaka","year":"1998","unstructured":"Hosaka, J., S. Roy, K. Kvernebo, I. Enge, and F. Laerum. In vitro function of an adjustable temporary venous spring filter: Comparison with the temporary RF02 filter and the permanent Greenfield vena cava filter. Acad. Radiol. 5(9):620\u2013625, 1998.","journal-title":"Acad. Radiol."},{"issue":"2029","key":"524_CR23","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1098\/rspa.2002.1060","volume":"459","author":"JD Humphrey","year":"2003","unstructured":"Humphrey, J. D. Continuum biomechanics of soft biological tissues. Proc. R. Soc. Lond. Series A 459(2029):3\u201346, 2003.","journal-title":"Proc. R. Soc. Lond. Series A"},{"key":"524_CR24","volume-title":"Cardiovascular implants \u2014 endovascular devices \u2014 part 3: Vena cava filters","author":"ISO 25539-3:2011ISO 25539-3:2011","year":"2011","unstructured":"ISO 25539-3:2011ISO 25539-3:2011. Cardiovascular implants \u2014 endovascular devices \u2014 part 3: Vena cava filters. Geneva: International Organization for Standardization, 2011."},{"issue":"2","key":"524_CR25","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1016\/S1051-0443(98)70272-6","volume":"9","author":"HJ Jaeger","year":"1998","unstructured":"Jaeger, H. J., S. Kolb, T. Mair, M. Geller, A. Christmann, R. K. Kinne, and K. D. Mathias. In vitro model for the evaluation of inferior vena cava filters: Effect of experimental parameters on thrombus-capturing efficacy of the Vena Tech-LGM filter. J. Vasc. Interv. Radiol. 9(2):295\u2013304, 1998.","journal-title":"J. Vasc. Interv. Radiol."},{"issue":"9","key":"524_CR26","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1097\/00004424-199709000-00003","volume":"32","author":"HJ Jaeger","year":"1997","unstructured":"Jaeger, H. J., T. Mair, M. Geller, R. K. Kinne, A. Christmann, and K. D. Mathias. A physiologic in vitro model of the inferior vena cava with a computer-controlled flow system for testing of inferior vena cava filters. Invest. Radiol. 32(9):511\u2013522, 1997.","journal-title":"Invest. Radiol."},{"issue":"4","key":"524_CR27","doi-asserted-by":"publisher","first-page":"e4232","DOI":"10.1002\/nbm.4232","volume":"33","author":"AA Joseph","year":"2020","unstructured":"Joseph, A. A., D. Voit, and J. Frahm. Inferior vena cava revisited \u2013 Real time flow MRI of respiratory maneuvers. NMR Biomed. 33(4):e4232, 2020.","journal-title":"NMR Biomed."},{"issue":"2","key":"524_CR28","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1148\/radiology.166.2.3336712","volume":"166","author":"AA Katsamouris","year":"1988","unstructured":"Katsamouris, A. A., A. C. Waltman, M. A. Delichatsios, and C. A. Athanasoulis. Inferior vena cava filters: In vitro comparison of clot trapping and flow dynamics. Radiology 166(2):351\u2013366, 1988.","journal-title":"Radiology"},{"issue":"3","key":"524_CR29","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1007\/BF00204141","volume":"18","author":"JA Kaufman","year":"1995","unstructured":"Kaufman, J. A., A. C. Waltman, S. M. Rivitz, and S. C. Geller. Anatomical observations on the renal veins and inferior vena cava at magnetic resonance angiography. CardioVasc. Interv. Radiol. 18(3):153\u2013157, 1995.","journal-title":"CardioVasc. Interv. Radiol."},{"issue":"7","key":"524_CR30","doi-asserted-by":"publisher","first-page":"e2990","DOI":"10.1002\/cnm.2990","volume":"34","author":"JM Lopez","year":"2018","unstructured":"Lopez, J. M., G. Fortuny, D. Puigjaner, J. Herrero, and F. Marimon. A comparative CFD study of four inferior vena cava filters. Int. J. Numer. Method. Biomed. Eng. 34(7):e2990, 2018.","journal-title":"Int. J. Numer. Method. Biomed. Eng."},{"issue":"3","key":"524_CR31","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1007\/s00270-001-0044-4","volume":"25","author":"H Lorch","year":"2002","unstructured":"Lorch, H., A. Dallmann, M. Zwaan, and H. Weiss. Efficacy of permanent and retrievable vena cava filters: experimental studies and evaluation of a new device. Cardiovasc. Intervent. Radiol. 25(3):193\u2013199, 2002.","journal-title":"Cardiovasc. Intervent. Radiol."},{"issue":"2","key":"524_CR32","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1007\/s002709900232","volume":"21","author":"H Lorch","year":"1998","unstructured":"Lorch, H., M. Zwaan, C. Kulke, and H. D. Weiss. In vitro studies of temporary vena cava filters. Cardiovasc. Intervent Radiol. 21(2):146\u2013150, 1998.","journal-title":"Cardiovasc. Intervent Radiol."},{"issue":"7","key":"524_CR33","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1097\/RLI.0b013e318036b42b","volume":"42","author":"AH Mahnken","year":"2007","unstructured":"Mahnken, A. H., J. Pfeffer, S. Stanzel, A. Mossdorf, R. W. G\u00fcnther, and T. Schmitz-Rode. In vitro evaluation of optionally retrievable and permanent IVC filters. Invest Radiol. 42(7):529\u2013535, 2007.","journal-title":"Invest Radiol."},{"issue":"2","key":"524_CR34","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1055\/s-0036-1582121","volume":"33","author":"JP Montgomery","year":"2016","unstructured":"Montgomery, J. P., and J. A. Kaufman. A critical review of available retrievable inferior vena cava filters and future directions. Semin. Intervent. Rad. 33(2):79\u201387, 2016.","journal-title":"Semin. Intervent. Rad."},{"issue":"6","key":"524_CR35","doi-asserted-by":"publisher","first-page":"3766","DOI":"10.1121\/1.2201251","volume":"119","author":"VM Nahirnyak","year":"2006","unstructured":"Nahirnyak, V. M., S. W. Yoon, and C. K. Holland. Acousto-mechanical and thermal properties of clotted blood. J. Acoust. Soc. Am. 119(6):3766\u20133772, 2006.","journal-title":"J. Acoust. Soc. Am."},{"issue":"4","key":"524_CR36","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1055\/s-2007-1015664","volume":"164","author":"J Neuerburg","year":"1996","unstructured":"Neuerburg, J., A. Haupt-Pichler, F. J. Katterbach, R. Eilers, T. Siess, K. Buro, C. von Pichler, K. Mottaghy, and R. W. G\u00fcnther. Determining the effectiveness of percutaneous cava filters: Experimental studies. Rofo. 164(4):331\u2013337, 1996.","journal-title":"Rofo."},{"issue":"3","key":"524_CR37","doi-asserted-by":"publisher","first-page":"504","DOI":"10.1016\/j.jbiomech.2014.11.047","volume":"48","author":"M Nicolas","year":"2015","unstructured":"Nicolas, M., M. Malve, E. Pe\u00f1a, M. A. Martinez, and R. Leask. In vitro comparison of G\u00fcnther Tulip and Celect filters. Testing filtering efficiency and pressure drop. J. Biomech. 48(3):504\u2013511, 2015.","journal-title":"J. Biomech."},{"issue":"2","key":"524_CR38","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1016\/j.icheatmasstransfer.2014.12.013","volume":"61","author":"M Nicolas","year":"2015","unstructured":"Nicolas, M., V. Palero, E. Pena, M. Arroyo, M. Martinez, and M. Malve. Numerical and experimental study of the fluid flow through a medical device. Int. Commun. Heat Mass 61(2):170\u2013178, 2015.","journal-title":"Int. Commun. Heat Mass"},{"issue":"6","key":"524_CR39","doi-asserted-by":"publisher","first-page":"835","DOI":"10.1016\/j.jvir.2010.12.024","volume":"22","author":"E Rahbar","year":"2011","unstructured":"Rahbar, E., D. Mori, and J. Moore, Jr. Three-dimensional analysis of flow disturbances caused by clots in inferior vena cava filters. J. Vasc. Interv. Radiol. 22(6):835\u2013842, 2011.","journal-title":"J. Vasc. Interv. Radiol."},{"key":"524_CR40","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1007\/s11517-012-0867-y","volume":"50","author":"Z Ren","year":"2012","unstructured":"Ren, Z., S. L. Wang, and M. A. Singer. Modeling hemodynamics in an unoccluded and partially occluded inferior vena cava under rest and exercise conditions. Med. Biol. Eng. Comput. 50:277\u2013287, 2012.","journal-title":"Med. Biol. Eng. Comput."},{"issue":"6","key":"524_CR41","doi-asserted-by":"publisher","first-page":"49","DOI":"10.2147\/MDER.S42555","volume":"10","author":"RA Robinson","year":"2013","unstructured":"Robinson, R. A., L. H. Herbertson, S. S. Das, R. A. Malinauskas, W. F. Pritchard, and L. W. Grossman. Limitations of using synthetic blood clots for measuring in vitro clot capture efficiency of inferior vena cava filters. Med. Devices 10(6):49\u201357, 2013.","journal-title":"Med. Devices"},{"issue":"4","key":"524_CR42","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1001\/archsurg.133.4.406","volume":"133","author":"FB Rogers","year":"1998","unstructured":"Rogers, F. B., G. Strindberg, S. R. Shackford, T. M. Osler, C. S. Morris, M. A. Ricci, K. E. Najarian, R. D\u2019Agostino, and D. B. Pilcher. Five-year follow-up of prophylactic vena cava filters in high-risk trauma patients. Arch. Surg. 133(4):406\u2013412, 1998.","journal-title":"Arch. Surg."},{"issue":"3","key":"524_CR43","doi-asserted-by":"publisher","first-page":"769","DOI":"10.1148\/radiology.189.3.8234702","volume":"189","author":"M Simon","year":"1993","unstructured":"Simon, M., D. J. Rabkin, S. Kleshinski, D. Kim, and B. J. Ransil. Comparative evaluation of inferior vena cava filters with an in vitro physiologic simulation of the vena cava. Radiology 189(3):769\u2013774, 1993.","journal-title":"Radiology"},{"issue":"6","key":"524_CR44","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1016\/j.jvir.2009.02.015","volume":"20","author":"MA Singer","year":"2009","unstructured":"Singer, M. A., W. D. Henshaw, and S. L. Wang. Computational modeling of blood flow in the TrapEase inferior vena cava filter. J. Vasc. Interv. Radiol. 20(6):799\u2013805, 2009.","journal-title":"J. Vasc. Interv. Radiol."},{"issue":"2","key":"524_CR45","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/j.jvir.2010.09.032","volume":"22","author":"MA Singer","year":"2011","unstructured":"Singer, M. A., and S. L. Wang. Modeling blood flow in a tilted inferior vena cava filter: Does tilt adversely affect hemodynamics? J. Vasc. Interv. Radiol. 22(2):229\u2013235, 2011.","journal-title":"J. Vasc. Interv. Radiol."},{"issue":"10","key":"524_CR46","doi-asserted-by":"publisher","first-page":"101006","DOI":"10.1115\/1.4002488","volume":"132","author":"MA Singer","year":"2010","unstructured":"Singer, M. A., S. L. Wang, and D. P. Diachin. Design optimization of vena cava filters: An application to dual filtration devices. J. Biomech. Eng. 132(10):101006, 2010.","journal-title":"J. Biomech. Eng."},{"issue":"11","key":"524_CR47","doi-asserted-by":"publisher","first-page":"1764","DOI":"10.1007\/s10439-008-9560-6","volume":"36","author":"SFC Stewart","year":"2008","unstructured":"Stewart, S. F. C., R. A. Robinson, R. A. Nelson, and R. A. Malinauskas. Effects of thrombosed vena cava filters on blood flow: Flow visualization and numerical modeling. Ann. Biomed. Eng. 36(11):1764\u20131781, 2008.","journal-title":"Ann. Biomed. Eng."},{"issue":"5","key":"524_CR48","doi-asserted-by":"publisher","first-page":"731","DOI":"10.1016\/S1051-0443(95)71175-7","volume":"6","author":"GW Stoneham","year":"1995","unstructured":"Stoneham, G. W., B. E. Burbridge, and S. F. Millward. Temporary inferior vena cava filters: In vitro comparison with permanent IVC filters. J. Vasc. Interv. Radiol. 6(5):731\u2013736, 1995.","journal-title":"J. Vasc. Interv. Radiol."},{"issue":"3","key":"524_CR49","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1115\/1.2187034","volume":"128","author":"TN Swaminathan","year":"2006","unstructured":"Swaminathan, T. N., H. H. Hu, and A. A. Patel. Numerical analysis of the hemodynamics and embolus capture of a Greenfield vena cava filter. J. Biomech. Eng. 128(3):360\u2013370, 2006.","journal-title":"J. Biomech. Eng."},{"issue":"4","key":"524_CR50","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.medengphy.2018.02.003","volume":"54","author":"E Tedaldi","year":"2018","unstructured":"Tedaldi, E., C. Montanari, K. I. Aycock, F. Sturla, A. Redaelli, and K. B. Manning. An experimental and computational study of the inferior vena cava hemodynamics under respiratory-induced collapse of the infrarenal IVC. Med. Eng. Phys. 54(4):44\u201355, 2018.","journal-title":"Med. Eng. Phys."},{"issue":"1","key":"524_CR51","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/0471143030.cb1016s47","volume":"47","author":"JR Tse","year":"2010","unstructured":"Tse, J. R., and A. J. Engler. Preparation of hydrogel substrates with tunable mechanical properties. Curr. Protoc. Cell Biol. 47(1):1\u201316, 2010.","journal-title":"Curr. Protoc. Cell Biol."},{"key":"524_CR52","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1007\/3-540-34596-5_15","volume-title":"Fluid\u2013Structure Interaction","author":"S Turek","year":"2006","unstructured":"Turek, S., and J. Hron. Proposal for numerical benchmarking of fluid\u2013structure interaction between an elastic object and laminar incompressible flow. In: Fluid\u2013Structure Interaction, edited by H. J. Bungartz, and M. Sch\u00e4fer. Berlin: Springer, 2006, pp. 371\u2013385."},{"issue":"2","key":"524_CR53","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1161\/ATVBAHA.116.308622","volume":"37","author":"V Tutwiler","year":"2017","unstructured":"Tutwiler, V., A. D. Peshkova, I. A. Adrianova, D. R. Khasanova, J. W. Weisel, and R. I. Litvinov. Contraction of blood clots is impaired in acute ischemic stroke. Arterioscl. Thromb. Vasc. Biol. 37(2):271\u2013279, 2017.","journal-title":"Arterioscl. Thromb. Vasc. Biol."},{"issue":"3","key":"524_CR54","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1016\/j.jvir.2009.11.013","volume":"21","author":"SL Wang","year":"2010","unstructured":"Wang, S. L., and M. A. Singer. Toward an optimal position for inferior vena cava filters: Computational modeling of the impact of renal vein inflow with Celect and TrapEase filters. J. Vasc. Interv. Radiol. 21(3):367\u2013374, 2010.","journal-title":"J. Vasc. Interv. Radiol."},{"issue":"8","key":"524_CR55","doi-asserted-by":"publisher","first-page":"1060","DOI":"10.1177\/0885328218824203","volume":"33","author":"C Yang","year":"2019","unstructured":"Yang, C., F. Ma, C. Gao, Y. Kang, G. Zhang, P. Liu, H. Jiang, and Z. Chang. Design and evaluation of a novel biodegradable inferior vena cava filter. J. Biomater. Appl. 33(8):1060\u20131069, 2019.","journal-title":"J. Biomater. Appl."}],"container-title":["Cardiovascular Engineering and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13239-021-00524-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s13239-021-00524-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13239-021-00524-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,29]],"date-time":"2023-01-29T22:31:20Z","timestamp":1675031480000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s13239-021-00524-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,8]]},"references-count":55,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,6]]}},"alternative-id":["524"],"URL":"https:\/\/doi.org\/10.1007\/s13239-021-00524-z","relation":{},"ISSN":["1869-408X","1869-4098"],"issn-type":[{"value":"1869-408X","type":"print"},{"value":"1869-4098","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,8]]},"assertion":[{"value":"15 October 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 February 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 March 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}