{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,17]],"date-time":"2025-04-17T11:49:51Z","timestamp":1744890591236},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2022,5,3]],"date-time":"2022-05-03T00:00:00Z","timestamp":1651536000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2022,5,3]],"date-time":"2022-05-03T00:00:00Z","timestamp":1651536000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Cardiovasc Eng Tech"],"published-print":{"date-parts":[[2022,12]]},"DOI":"10.1007\/s13239-022-00627-1","type":"journal-article","created":{"date-parts":[[2022,5,3]],"date-time":"2022-05-03T21:08:57Z","timestamp":1651612137000},"page":"930-938","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Redo Transcatheter Aortic Valve Implantation with the ALLEGRA Transcatheter Heart Valve: Insights from Bench Testing"],"prefix":"10.1007","volume":"13","author":[{"given":"Mariama","family":"Akodad","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maximilian","family":"K\u00fctting","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephanie","family":"Sellers","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alina","family":"Kirsten","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philipp","family":"Marx","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Isabel","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anson","family":"Cheung","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonathon","family":"Leipsic","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lars","family":"S\u00f8ndergaard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefan","family":"Toggweiler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David A.","family":"Wood","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John G.","family":"Webb","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Janarthanan","family":"Sathananthan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,5,3]]},"reference":[{"key":"627_CR1","unstructured":"Cardiovascular implants - cardiac valve prosthesis. Part 3: Heart valve substitutes implanted by trans catheter techniques. In: organization Is, editor. Geneva, Switzerland: International standard organization; 2013."},{"key":"627_CR2","doi-asserted-by":"publisher","first-page":"71","DOI":"10.4244\/EIJ-D-18-00861","volume":"15","author":"O Cuevas","year":"2019","unstructured":"Cuevas, O., R. Moreno, V. Pascual-Tejerina, S. Toggweiler, M. Brinkert, J. Baz, et al. The Allegra transcatheter heart valve: European multicentre experience with a novel self-expanding transcatheter aortic valve. EuroIntervention. 15:71\u201373, 2019. https:\/\/doi.org\/10.4244\/EIJ-D-18-00861.","journal-title":"EuroIntervention."},{"key":"627_CR3","doi-asserted-by":"publisher","first-page":"2528","DOI":"10.1016\/j.jcin.2020.06.016","volume":"13","author":"O DeBacker","year":"2020","unstructured":"DeBacker, O., U. Landes, A. Fuchs, S.-H. Yoon, O. N. Mathiassen, A. Sedaghat, et al. Coronary Access After TAVR-in-TAVR as Evaluated by Multidetector Computed Tomography. JACC Cardiovascular Interventions. 13:2528\u20132538, 2020. https:\/\/doi.org\/10.1016\/j.jcin.2020.06.016.","journal-title":"JACC Cardiovascular Interventions."},{"issue":"22","key":"627_CR4","doi-asserted-by":"publisher","first-page":"2314","DOI":"10.1016\/j.jcin.2018.07.023","volume":"11","author":"K Hellhammer","year":"2018","unstructured":"Hellhammer, K., K. Piayda, S. Afzal, L. Kleinebrecht, M. Makosch, I. Hennig, et al. The latest evolution of the medtronic corevalve system in the era of transcatheter aortic valve replacement: matched comparison of the Evolut PRO and Evolut R. JACC Cardiovasc Interv. 11(22):2314\u20132322, 2018.","journal-title":"JACC Cardiovasc Interv."},{"issue":"16","key":"627_CR5","doi-asserted-by":"publisher","first-page":"1882","DOI":"10.1016\/j.jacc.2020.02.051","volume":"75","author":"U Landes","year":"2020","unstructured":"Landes, U., J. G. Webb, O. De Backer, L. Sondergaard, M. Abdel-Wahab, L. Crusius, et al. Repeat transcatheter aortic valve replacement for transcatheter prosthesis dysfunction. J Am Coll Cardiol. 75(16):1882\u20131893, 2020. https:\/\/doi.org\/10.1016\/j.jacc.2020.02.051.","journal-title":"J Am Coll Cardiol."},{"issue":"18","key":"627_CR6","doi-asserted-by":"publisher","first-page":"1695","DOI":"10.1056\/NEJMoa1814052","volume":"380","author":"MJ Mack","year":"2019","unstructured":"Mack, M. J., M. B. Leon, V. H. Thourani, R. Makkar, S. K. Kodali, M. Russo, et al. Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients. N Engl J Med. 380(18):1695\u20131705, 2019. https:\/\/doi.org\/10.1056\/NEJMoa1814052.","journal-title":"N Engl J Med."},{"key":"627_CR7","doi-asserted-by":"publisher","first-page":"1618","DOI":"10.1016\/j.jcin.2016.05.030","volume":"9","author":"PA Midha","year":"2016","unstructured":"Midha, P. A., V. Raghav, J. F. Condado, I. U. Okafor, S. Lerakis, V. H. Thourani, et al. Valve type, size, and deployment location affect hemodynamics in an in vitro valve-in-valve model. JACC. 9:1618\u20131628, 2016. https:\/\/doi.org\/10.1016\/j.jcin.2016.05.030.","journal-title":"JACC"},{"issue":"13","key":"627_CR8","doi-asserted-by":"publisher","first-page":"1653","DOI":"10.4244\/EIJ-D-16-00299","volume":"12","author":"GY Perlman","year":"2017","unstructured":"Perlman, G. Y., A. Cheung, E. Dumont, D. Stub, D. Dvir, M. Del Trigo, et al. Transcatheter aortic valve replacement with the Portico valve: one-year results of the early Canadian experience. EuroIntervention. 12(13):1653\u20131659, 2017.","journal-title":"EuroIntervention."},{"issue":"9","key":"627_CR9","doi-asserted-by":"publisher","first-page":"e739","DOI":"10.4244\/EIJV15I9A137","volume":"15","author":"M Pighi","year":"2019","unstructured":"Pighi, M., M. Lunardi, and F. L. Ribichini. NVT ALLEGRA transcatheter heart valve for valve-in-valve procedures in failing surgical aortic bioprostheses: let us wait and see. EuroIntervention. 15(9):e739\u2013e741, 2019. https:\/\/doi.org\/10.4244\/EIJV15I9A137.","journal-title":"EuroIntervention"},{"issue":"18","key":"627_CR10","doi-asserted-by":"publisher","first-page":"1706","DOI":"10.1056\/NEJMoa1816885","volume":"380","author":"JJ Popma","year":"2019","unstructured":"Popma, J. J., G. M. Deeb, S. J. Yakubov, M. Mumtaz, H. Gada, D. O\u2019Hair, et al. Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients. N Engl J Med. 380(18):1706\u20131715, 2019. https:\/\/doi.org\/10.1056\/NEJMoa1816885.","journal-title":"N Engl J Med."},{"key":"627_CR11","doi-asserted-by":"publisher","first-page":"e1335","DOI":"10.4244\/EIJ-D-19-00782","volume":"15","author":"J Sathananthan","year":"2020","unstructured":"Sathananthan, J., R. Fraser, M. K\u00fctting, M. Hensey, U. Landes, A. Alkhodair, et al. Impact of implant depth on hydrodynamic function of the ALLEGRA bioprosthesis in valve-in-valve interventions. EuroIntervention. 15:e1335\u2013e1342, 2020. https:\/\/doi.org\/10.4244\/EIJ-D-19-00782.","journal-title":"EuroIntervention."},{"key":"627_CR12","doi-asserted-by":"publisher","DOI":"10.4244\/EIJ-D-20-00697","author":"J Sathananthan","year":"2021","unstructured":"Sathananthan, J., R. Fraser, U. Landes, C. Rich, S. L. Sellers, J. Leipsic, et al. Repeat transcatheter aortic valve replacement and implications for transcatheter heart valve performance: insights from bench testing. EuroIntervention. 2021. https:\/\/doi.org\/10.4244\/EIJ-D-20-00697.","journal-title":"EuroIntervention."},{"issue":"1","key":"627_CR13","doi-asserted-by":"publisher","first-page":"78","DOI":"10.4244\/EIJ-D-18-00947","volume":"15","author":"J Sathananthan","year":"2019","unstructured":"Sathananthan, J., S. L. Sellers, R. Fraser, D. Dvir, M. Hensey, D. J. Murdoch, et al. Impact of implant depth on hydrodynamic function with the ACURATE neo transcatheter heart valve following valve-in-valve transcatheter aortic valve replacement in Mitroflow bioprosthetic valves: an ex vivo bench study. EuroIntervention. 15(1):78\u201387, 2019.","journal-title":"EuroIntervention."},{"key":"627_CR14","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1007\/s11886-019-1234-5","volume":"21","author":"ME Seigerman","year":"2019","unstructured":"Seigerman, M. E., A. Nathan, and S. Anwaruddin. the lotus valve system: an in-depth review of the technology. Curr Cardiol Rep. 21:157, 2019. https:\/\/doi.org\/10.1007\/s11886-019-1234-5.","journal-title":"Curr Cardiol Rep"},{"key":"627_CR15","doi-asserted-by":"publisher","first-page":"88","DOI":"10.4244\/EIJV8SQA16","volume":"8","author":"H Treede","year":"2012","unstructured":"Treede, H., A. Rastan, M. Ferrari, S. Ensminger, H.-R. Figulla, and F.-W. Mohr. JenaValve. EuroIntervention. 8:88\u201393, 2012. https:\/\/doi.org\/10.4244\/EIJV8SQA16.","journal-title":"EuroIntervention"},{"issue":"21","key":"627_CR16","doi-asserted-by":"publisher","first-page":"2235","DOI":"10.1016\/j.jacc.2014.09.026","volume":"64","author":"J Webb","year":"2014","unstructured":"Webb, J., G. Gerosa, T. Lef\u00e8vre, J. Leipsic, M. Spence, M. Thomas, et al. Multicenter evaluation of a next-generation balloon-expandable transcatheter aortic valve. J Am Coll Cardiol. 64(21):2235\u20132243, 2014. https:\/\/doi.org\/10.1016\/j.jacc.2014.09.026.","journal-title":"J Am Coll Cardiol"},{"issue":"71\u201377","key":"627_CR17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.4244\/EIJV12I1A13","volume":"12","author":"P Wenaweser","year":"2016","unstructured":"Wenaweser, P., S. Stortecky, T. Sch\u00fctz, F. Praz, S. Gloekler, S. Windecker, et al. Transcatheter aortic valve implantation with the NVT Allegra transcatheter heart valve system: first-in-human experience with a novel self-expanding transcatheter heart valve. EuroIntervention. 12(71\u201377):1, 2016. https:\/\/doi.org\/10.4244\/EIJV12I1A13.","journal-title":"EuroIntervention."}],"container-title":["Cardiovascular Engineering and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13239-022-00627-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s13239-022-00627-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13239-022-00627-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,14]],"date-time":"2022-12-14T21:52:25Z","timestamp":1671054745000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s13239-022-00627-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,3]]},"references-count":17,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["627"],"URL":"https:\/\/doi.org\/10.1007\/s13239-022-00627-1","relation":{},"ISSN":["1869-408X","1869-4098"],"issn-type":[{"value":"1869-408X","type":"print"},{"value":"1869-4098","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,3]]},"assertion":[{"value":"15 August 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 April 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 May 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Yes","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Data availability"}},{"value":"Not applicable","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Code availability"}},{"value":"Dr Akodad has received research funding from Medtronic, Biotronik, MUSE Explore and Federation Fran\u00e7aise de Cardiologie. Dr K\u00fctting, A. Kirsten and Philipp Marx are employees of NVT. Dr. Sellers is supported by fellowships from the Canadian Institutes of Health Research and the Michael Smith Foundation for Health Research. Dr Leipsic is consultant to Edwards Lifesciences and provide CT core lab services for Edwards Lifesciences, Medtronic, Neovasc, Guided Delivery Systems, and Abbott, for which no direct compensation is received. Dr. Toggweiler is a proctor and consultant for Biosensors \/ New Valve Technology, Medtronic and Boston Scientific, a proctor for Abbott, a consultant for Shockwave, Teleflex, Medira, at Heart Medical, Veosource, has received institutional research grants from Boston Scientific and Fumedica and holds equity in Hi-D Imaging. Dr Wood is a consultant to, and has received research funding from, Edwards Lifesciences and Abbott. Dr. Webb is a consultant to, and has received research funding from, Edwards Lifesciences, Abbott, and Medtronic. Lars Sondergaard has received consultant fees and institutional research grants from Abbott, Boston Scientific, Edwards Lifesciences, Medtronic, and Symetis. Dr Sathananthan is a consultant to Edwards Lifesciences, Boston Scientific and Medtronic. He has received research funding from Medtronic and Edwards Lifesciences. The other authors do not have any relevant disclosures.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical Approval"}},{"value":"Not applicable.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"Not applicable.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}]}}