{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T05:30:13Z","timestamp":1790832613245,"version":"4.1.0"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2023,12,18]],"date-time":"2023-12-18T00:00:00Z","timestamp":1702857600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,12,18]],"date-time":"2023-12-18T00:00:00Z","timestamp":1702857600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100010665","name":"H2020 Marie Sk\u0142odowska-Curie Actions","doi-asserted-by":"publisher","award":["859836"],"award-info":[{"award-number":["859836"]}],"id":[{"id":"10.13039\/100010665","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Cardiovasc Eng Tech"],"published-print":{"date-parts":[[2024,4]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>Inappropriate stent-graft (SG) flexibility has been frequently associated with endovascular aortic repair (EVAR) complications such as endoleaks, kinks, and SG migration, especially in tortuous arteries. Stents derived from auxetic unit cells have shown some potential to address these issues as they offer an optimum trade-off between radial stiffness and bending flexibility.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>In this study, we utilized an established finite element (FE)-based approach to replicate the mechanical response of a SG iliac limb derived from auxetic unit cells in a virtual tortuous iliac aneurysm using a combination of a 180\u00b0 U-bend and intraluminal pressurization. This study aimed to compare the mechanical performance (flexibility and durability) of SG limbs derived from auxetic unit cells and two commercial SG limbs (Z-stented SG and circular-stented SG models) in a virtual tortuous iliac aneurysm. Maximal graft strain and maximum stress in stents were employed as criteria to estimate the durability of SGs, whereas the maximal luminal reduction rate and the bending stiffness were used to assess the flexibility of the SGs.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>SG limbs derived from auxetic unit cells demonstrated low luminal reduction (range 4\u201312%) with no kink, in contrast to Z-stented SG, which had a kink in its central area alongside a high luminal reduction (44%).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>SG limbs derived from auxetic unit cells show great promise for EVAR applications even at high angulations such as 180\u00b0, with acceptable levels of durability and flexibility.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s13239-023-00706-x","type":"journal-article","created":{"date-parts":[[2023,12,18]],"date-time":"2023-12-18T19:03:00Z","timestamp":1702926180000},"page":"199-210","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Computational Comparison of the Mechanical Behavior of Aortic Stent-Grafts Derived from Auxetic Unit Cells"],"prefix":"10.1007","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2538-5598","authenticated-orcid":false,"given":"Rahul","family":"Vellaparambil","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3811-3919","authenticated-orcid":false,"given":"Woo-Suck","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6854-6865","authenticated-orcid":false,"given":"Pierluigi","family":"Di Giovanni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8604-7736","authenticated-orcid":false,"given":"St\u00e9phane","family":"Avril","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,12,18]]},"reference":[{"key":"706_CR1","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1007\/BF02015271","volume":"5","author":"JC Parodi","year":"1991","unstructured":"Parodi, J. C., J. C. Palmaz, and H. D. Barone. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann. Vasc. Surg. 5:491\u2013499, 1991. https:\/\/doi.org\/10.1007\/BF02015271.","journal-title":"Ann. Vasc. Surg."},{"key":"706_CR2","doi-asserted-by":"publisher","first-page":"263","DOI":"10.5090\/kjtcs.2017.50.4.263","volume":"50","author":"M Bae","year":"2017","unstructured":"Bae, M., S. W. Chung, C. W. Lee, S. Song, E. Kim, and C. W. Kim. A comparative study of abdominal aortic aneurysm: endovascular aneurysm repair versus open repair. Korean J. Thorac Cardiovasc. Surg. 50:263\u2013269, 2017. https:\/\/doi.org\/10.5090\/kjtcs.2017.50.4.263.","journal-title":"Korean J. Thorac Cardiovasc. Surg."},{"key":"706_CR3","doi-asserted-by":"publisher","first-page":"2366","DOI":"10.1016\/S0140-6736(16)31135-7","volume":"388","author":"R Patel","year":"2016","unstructured":"Patel, R., M. J. Sweeting, J. T. Powell, and R. M. Greenhalgh. Endovascular versus open repair of abdominal aortic aneurysm in 15-years\u2019 follow-up of the UK endovascular aneurysm repair trial 1 (EVAR trial 1): a randomised controlled trial. Lancet. 388:2366\u20132374, 2016. https:\/\/doi.org\/10.1016\/S0140-6736(16)31135-7.","journal-title":"Lancet"},{"key":"706_CR4","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1016\/j.jvs.2019.05.057","volume":"71","author":"JA Columbo","year":"2020","unstructured":"Columbo, J. A., N. Ramkumar, P. Martinez-Camblor, R. Kang, B. D. Suckow, A. J. O\u2019Malley, A. Sedrakyan, and P. P. Goodney. Five-year reintervention after endovascular abdominal aortic aneurysm repair in the Vascular Quality Initiative. J. Vasc. Surg. 71:799-805.e1, 2020. https:\/\/doi.org\/10.1016\/j.jvs.2019.05.057.","journal-title":"J. Vasc. Surg."},{"key":"706_CR5","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1148\/rg.352140045","volume":"35","author":"Y Bryce","year":"2015","unstructured":"Bryce, Y., P. Rogoff, D. Romanelli, and R. Reichle. Endovascular repair of abdominal aortic aneurysms: vascular anatomy, device selection, procedure, and procedure-specific complications. RadioGraphics. 35:593\u2013615, 2015. https:\/\/doi.org\/10.1148\/rg.352140045.","journal-title":"RadioGraphics"},{"key":"706_CR6","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1067\/mva.2002.120045","volume":"35","author":"P Cao","year":"2002","unstructured":"Cao, P., F. Verzini, S. Zannetti, P. De Rango, G. Parlani, L. Lupattelli, and A. Maselli. Device migration after endoluminal abdominal aortic aneurysm repair: analysis of 113 cases with a minimum follow-up period of 2 years. J. Vasc. Surg. 35:229\u2013235, 2002. https:\/\/doi.org\/10.1067\/mva.2002.120045.","journal-title":"J. Vasc. Surg."},{"key":"706_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jvs.2004.03.008","volume":"40","author":"CK Zarins","year":"2004","unstructured":"Zarins, C. K., F. R. Arko, T. Crabtree, D. A. Bloch, K. Ouriel, R. C. Allen, and R. A. White. Explant analysis of AneuRx stent grafts: relationship between structural findings and clinical outcome. J. Vasc. Surg. 40:1\u201311, 2004. https:\/\/doi.org\/10.1016\/j.jvs.2004.03.008.","journal-title":"J. Vasc. Surg."},{"key":"706_CR8","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1016\/j.jss.2018.05.073","volume":"232","author":"H Krishnamoorthi","year":"2018","unstructured":"Krishnamoorthi, H., H. Jeon-Slaughter, A. Wall, S. Banerjee, B. Ramanan, C. Timaran, J. G. Modrall, and S. Tsai. Rate of secondary intervention after open versus endovascular abdominal aortic aneurysm repair. J. Surg. Res. 232:99\u2013106, 2018. https:\/\/doi.org\/10.1016\/j.jss.2018.05.073.","journal-title":"J. Surg. Res."},{"key":"706_CR9","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1177\/152660289900600105","volume":"6","author":"T Umscheid","year":"1999","unstructured":"Umscheid, T., and W. J. Stelter. Time-related alterations in shape, position, and structure of self-expanding, modular aortic stent-grafts: a 4-year single-center follow-up. J. Endovasc. Surg. 6:17\u201332, 1999. https:\/\/doi.org\/10.1177\/152660289900600105.","journal-title":"J. Endovasc. Surg."},{"key":"706_CR10","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1067\/mva.2002.128309","volume":"36","author":"A Carroccio","year":"2002","unstructured":"Carroccio, A., P. L. Faries, N. J. Morrissey, V. Teodorescu, J. A. Burks, E. C. Gravereaux, L. H. Hollier, and M. L. Marin. Predicting iliac limb occlusions after bifurcated aortic stent grafting: anatomic and device-related causes. J. Vasc. Surg. 36:679\u2013684, 2002. https:\/\/doi.org\/10.1067\/mva.2002.128309.","journal-title":"J. Vasc. Surg."},{"key":"706_CR11","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1258\/rsmvasc.13.6.321","volume":"13","author":"J-N Albertini","year":"2005","unstructured":"Albertini, J.-N., M.-A. DeMasi, J. Macierewicz, R. El Idrissi, B. R. Hopkinson, C. Cl\u00e9ment, and A. Branchereau. aorfix stent graft for abdominal aortic aneurysms reduces the risk of proximal type 1 endoleak in angulated necks: Bench-Test Study. Vascular. 13:321\u2013326, 2005. https:\/\/doi.org\/10.1258\/rsmvasc.13.6.321.","journal-title":"Vascular"},{"key":"706_CR12","first-page":"461","volume":"51","author":"AR Weale","year":"2010","unstructured":"Weale, A. R., K. Balasubramaniam, J. Hardman, and M. Horrocks. Use of the AorfixTM stent graft in patients with tortuous iliac anatomy. J. Cardiovasc. Surg. (Torino). 51:461\u2013466, 2010.","journal-title":"J. Cardiovasc. Surg. (Torino)"},{"key":"706_CR13","doi-asserted-by":"publisher","first-page":"2370","DOI":"10.1016\/j.jbiomech.2008.05.032","volume":"41","author":"C Kleinstreuer","year":"2008","unstructured":"Kleinstreuer, C., Z. Li, C. A. Basciano, S. Seelecke, and M. A. Farber. Computational mechanics of Nitinol stent grafts. J. Biomech. 41:2370\u20132378, 2008. https:\/\/doi.org\/10.1016\/j.jbiomech.2008.05.032.","journal-title":"J. Biomech."},{"key":"706_CR14","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1016\/j.jmbbm.2011.09.006","volume":"5","author":"N Demanget","year":"2012","unstructured":"Demanget, N., S. Avril, P. Badel, L. Org\u00e9as, C. Geindreau, J.-N. Albertini, and J.-P. Favre. Computational comparison of the bending behavior of aortic stent-grafts. J. Mech. Behav. Biomed. Mater. 5:272\u2013282, 2012. https:\/\/doi.org\/10.1016\/j.jmbbm.2011.09.006.","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"706_CR15","doi-asserted-by":"publisher","first-page":"2674","DOI":"10.1007\/s10439-012-0618-0","volume":"40","author":"N Demanget","year":"2012","unstructured":"Demanget, N., P. Latil, L. Org\u00e9as, P. Badel, S. Avril, C. Geindreau, J.-N. Albertini, and J.-P. Favre. Severe bending of two aortic stent-grafts: an experimental and numerical mechanical analysis. Ann. Biomed. Eng. 40:2674\u20132686, 2012. https:\/\/doi.org\/10.1007\/s10439-012-0618-0.","journal-title":"Ann. Biomed. Eng."},{"key":"706_CR16","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1583\/12-4063.1","volume":"20","author":"N Demanget","year":"2013","unstructured":"Demanget, N., A. Duprey, P. Badel, L. Org\u00e9as, S. Avril, C. Geindreau, J.-N. Albertini, and J.-P. Favre. Finite element analysis of the mechanical performances of 8 marketed aortic stent-grafts. J. Endovasc. Ther. 20:523\u2013535, 2013. https:\/\/doi.org\/10.1583\/12-4063.1.","journal-title":"J. Endovasc. Ther."},{"key":"706_CR17","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2022.105644","volume":"138","author":"R Vellaparambil","year":"2023","unstructured":"Vellaparambil, R., W.-S. Han, P. Di Giovanni, and S. Avril. Potential of auxetic designs in endovascular aortic repair: a computational study of their mechanical performance. J. Mech. Behav. Biomed. Mater.138:105644, 2023. https:\/\/doi.org\/10.1016\/j.jmbbm.2022.105644.","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"706_CR18","doi-asserted-by":"publisher","DOI":"10.1002\/cnm.2698","volume":"31","author":"D Perrin","year":"2015","unstructured":"Perrin, D., N. Demanget, P. Badel, S. Avril, L. Org\u00e9as, C. Geindreau, and J.-N. Albertini. Deployment of stent grafts in curved aneurysmal arteries: toward a predictive numerical tool. Int. J. Numer. Meth. Biomed. Eng.31:e02698, 2015. https:\/\/doi.org\/10.1002\/cnm.2698.","journal-title":"Int. J. Numer. Meth. Biomed. Eng."},{"key":"706_CR19","doi-asserted-by":"publisher","first-page":"103852","DOI":"10.1016\/j.jmbbm.2020.103852","volume":"110","author":"M Dalbosco","year":"2020","unstructured":"Dalbosco, M., C. R. M. Roesler, P. G. Silveira, and E. A. Fancello. Numerical study on the effect of stent shape on suture forces in stent-grafts. J. Mech. Behav. Biomed. Mater. 110:103852, 2020. https:\/\/doi.org\/10.1016\/j.jmbbm.2020.103852.","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"706_CR20","doi-asserted-by":"publisher","first-page":"800","DOI":"10.3934\/mbe.2021042","volume":"18","author":"Z Liu","year":"2021","unstructured":"Liu, Z., L. Wu, J. Yang, F. Cui, P. Ho, L. Wang, J. Dong, and G. Chen. Thoracic aorta stent grafts design in terms of biomechanical investigations into flexibility. Math. Biosci. Eng. 18:800\u2013816, 2021. https:\/\/doi.org\/10.3934\/mbe.2021042.","journal-title":"Math. Biosci. Eng."},{"key":"706_CR21","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1016\/j.jmbbm.2018.09.005","volume":"88","author":"Y Han","year":"2018","unstructured":"Han, Y., and W. Lu. Optimizing the deformation behavior of stent with nonuniform Poisson\u2019s ratio distribution for curved artery. Journal of the Mechanical Behavior of Biomedical Materials. 88:442\u2013452, 2018. https:\/\/doi.org\/10.1016\/j.jmbbm.2018.09.005.","journal-title":"Journal of the Mechanical Behavior of Biomedical Materials"},{"key":"706_CR22","unstructured":"Zenith Flex\u00ae. AUI AAA Endovascular Graft with the Z-Trak\u2122 Introduction System Instructions for use. https:\/\/ifu.cookmedical.com\/ifuPub\/ReadFile?fileName=T_ZAUI_REV1.PDF."},{"key":"706_CR23","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2018\/3046576","volume":"2018","author":"Y Guan","year":"2018","unstructured":"Guan, Y., J. Lin, Z. Dong, and L. Wang. Comparative study of the effect of structural parameters on the flexibility of endovascular stent grafts. Adv. Mater. Sci. Eng. 2018:1\u201310, 2018. https:\/\/doi.org\/10.1155\/2018\/3046576.","journal-title":"Adv. Mater. Sci. Eng."},{"key":"706_CR24","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1080\/13645706.2020.1745849","volume":"31","author":"S Yan","year":"2022","unstructured":"Yan, S., C. Song, Y. Si, and Y. Zhao. Design of non-equal-strut stent hoops for structural optimization of thoracic aortic stent-grafts. Minim. Invas. Ther. Allied Technol. 31:58\u201371, 2022. https:\/\/doi.org\/10.1080\/13645706.2020.1745849.","journal-title":"Minim. Invas. Ther. Allied Technol."},{"key":"706_CR25","doi-asserted-by":"publisher","first-page":"2477","DOI":"10.1016\/j.jbiomech.2013.07.010","volume":"46","author":"S De Bock","year":"2013","unstructured":"De Bock, S., F. Iannaccone, M. De Beule, D. Van Loo, F. Vermassen, B. Verhegghe, and P. Segers. Filling the void: a coalescent numerical and experimental technique to determine aortic stent graft mechanics. J. Biomech. 46:2477\u20132482, 2013. https:\/\/doi.org\/10.1016\/j.jbiomech.2013.07.010.","journal-title":"J. Biomech."},{"key":"706_CR26","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2021.104407","volume":"118","author":"J Kwiecinski","year":"2021","unstructured":"Kwiecinski, J., C. P. Cheng, R. Uberoi, M. Hadi, P. Hempel, C. Degel, and Z. You. Thoracic aortic parallel stent-graft behaviour when subjected to radial loading. J. Mech. Behav. Biomed. Mater.118:104407, 2021. https:\/\/doi.org\/10.1016\/j.jmbbm.2021.104407.","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"706_CR27","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1016\/j.ejvs.2019.03.019","volume":"58","author":"A Coelho","year":"2019","unstructured":"Coelho, A., C. Nogueira, M. Lobo, R. Gouveia, J. Campos, R. Augusto, N. Coelho, A. C. Semi\u00e3o, J. P. Ribeiro, and A. Canedo. Impact of post-EVAR graft limb kinking in EVAR limb occlusion: aetiology, early diagnosis, and management. Eur. J. Vasc. Endovasc. Surg. 58:681\u2013689, 2019. https:\/\/doi.org\/10.1016\/j.ejvs.2019.03.019.","journal-title":"Eur. J. Vasc. Endovasc. Surg."},{"key":"706_CR28","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1080\/136457002760273340","volume":"11","author":"D Stoeckel","year":"2002","unstructured":"Stoeckel, D., C. Bonsignore, and S. Duda. A survey of stent designs. Minim. Invasive Ther. Allied Technol. 11:137\u2013147, 2002. https:\/\/doi.org\/10.1080\/136457002760273340.","journal-title":"Minim. Invasive Ther. Allied Technol."},{"key":"706_CR29","doi-asserted-by":"publisher","first-page":"1868","DOI":"10.1016\/j.jbiomech.2015.04.031","volume":"48","author":"D Perrin","year":"2015","unstructured":"Perrin, D., P. Badel, L. Org\u00e9as, C. Geindreau, A. Dumenil, J.-N. Albertini, and S. Avril. Patient-specific numerical simulation of stent-graft deployment: validation on three clinical cases. J. Biomech. 48:1868\u20131875, 2015. https:\/\/doi.org\/10.1016\/j.jbiomech.2015.04.031.","journal-title":"J. Biomech."},{"key":"706_CR30","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1080\/10255842.2018.1427740","volume":"21","author":"VA Acosta Santamar\u00eda","year":"2018","unstructured":"Acosta Santamar\u00eda, V. A., G. Daniel, D. Perrin, J. N. Albertini, E. Rosset, and S. Avril. Model reduction methodology for computational simulations of endovascular repair. Comput. Methods Biomech. Biomed. Eng. 21:139\u2013148, 2018. https:\/\/doi.org\/10.1080\/10255842.2018.1427740.","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"706_CR31","doi-asserted-by":"publisher","first-page":"1941","DOI":"10.1007\/s10439-022-03014-y","volume":"50","author":"A Ramella","year":"2022","unstructured":"Ramella, A., F. Migliavacca, J. F. Rodriguez Matas, F. Heim, F. Dedola, S. Marconi, M. Conti, S. Allievi, T. J. Mandigers, D. Bissacco, M. Domanin, S. Trimarchi, and G. Luraghi. Validation and verification of high-fidelity simulations of thoracic stent-graft implantation. Ann. Biomed. Eng. 50:1941\u20131953, 2022. https:\/\/doi.org\/10.1007\/s10439-022-03014-y.","journal-title":"Ann. Biomed. Eng."}],"container-title":["Cardiovascular Engineering and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13239-023-00706-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s13239-023-00706-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13239-023-00706-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,23]],"date-time":"2024-05-23T19:15:21Z","timestamp":1716491721000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s13239-023-00706-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,18]]},"references-count":31,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,4]]}},"alternative-id":["706"],"URL":"https:\/\/doi.org\/10.1007\/s13239-023-00706-x","relation":{},"ISSN":["1869-408X","1869-4098"],"issn-type":[{"value":"1869-408X","type":"print"},{"value":"1869-4098","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,18]]},"assertion":[{"value":"29 June 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 December 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 December 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Stephane Avril is a cofounder of Predisurge SAS, France. The other authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}