{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,11]],"date-time":"2026-02-11T14:27:56Z","timestamp":1770820076351,"version":"3.50.1"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,12,15]],"date-time":"2025-12-15T00:00:00Z","timestamp":1765756800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,12,15]],"date-time":"2025-12-15T00:00:00Z","timestamp":1765756800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Cardiovasc Eng Tech"],"published-print":{"date-parts":[[2026,2]]},"DOI":"10.1007\/s13239-025-00812-y","type":"journal-article","created":{"date-parts":[[2025,12,15]],"date-time":"2025-12-15T19:14:38Z","timestamp":1765826078000},"page":"64-75","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of Blood-Sampling Performance of Automatic Fingertip-Blood-Sampling System and Correlation Between Fingertip-Blood-Vessel Image and Blood-Sampling Volume"],"prefix":"10.1007","volume":"17","author":[{"given":"Takashi","family":"Irie","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3791-1081","authenticated-orcid":false,"given":"Kei","family":"Takenaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sakuichiro","family":"Adachi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Taku","family":"Sakazume","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuji","family":"Oyamada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroki","family":"Doi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Taku","family":"Kato","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroyasu","family":"Ito","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,12,15]]},"reference":[{"key":"812_CR1","unstructured":"United Nations: World Population Prospects 2019 Highlights. https:\/\/population.un.org\/wpp\/assets\/Files\/WPP2019_Highlights.pdf. Accessed 7 Mar 2025."},{"key":"812_CR2","unstructured":"Prime Minister\u2019s Office of Japan home page. New Growth Strategy: The Formulation of \"Japan Revitalisation Strategy-Japan is Back-\". https:\/\/japan.kantei.go.jp\/96_abe\/documents\/2013\/1200485_7321.html. Accessed 7 Mar 2025."},{"key":"812_CR3","unstructured":"Ministry of Health, Labour and Welfare. Annual Health, Labour and Welfare Report 2014 Edition. https:\/\/www.mhlw.go.jp\/english\/wp\/wp-hw8\/dl\/summary.pdf. Accessed 7 Mar 2025."},{"key":"812_CR4","unstructured":"National Institutes of Health National Heart, Lung, and Blood Institute Home page. Blood Tests. https:\/\/www.nhlbi.nih.gov\/health\/blood-tests. Accessed 7 Mar 2025."},{"key":"812_CR5","unstructured":"M.F. Hill, and M. Bordoni: Hyperlipidemia. in: StatPearls [Internet]. Treasure Island (FL). StatPearls Publishing. 2025. https:\/\/www.ncbi.nlm.nih.gov\/books\/NBK559182\/. Accessed 7 Mar 2025"},{"key":"812_CR6","unstructured":"A. Vasavada and L.F.F Taub: Diabetes Mellitus Screening. In: StatPearls [Internet]. Treasure Island (FL). StatPearls Publishing. 2025. https:\/\/www.ncbi.nlm.nih.gov\/books\/NBK554615\/. Accessed 7 Mar 2025"},{"key":"812_CR7","unstructured":"M.S.D. Lorenzo: Strasinger SK. Blood Collection: A SHORT COURSE 2nd edition. F. A Davis company; 2010. https:\/\/www.fadavis.com\/product\/patient-care-technician-blood-collection-course-dilorenzo-strasinger-2."},{"key":"812_CR8","unstructured":"Japanese Association of Medical Technologists. Fact-finding survey of membership organizations 2015 (in Japanese). https:\/\/www.jamt.or.jp\/data\/asset\/docs\/h27_statistics_report.pdf. Accessed 7 Mar 2025"},{"key":"812_CR9","unstructured":"L.Giesen, J. Roest, M. Fouraux, M. Deckers, and T.V. Holten: Autonomous blood drawing optimization and performance testing. VITESTRO White paper. 2024. https:\/\/vitestro.com\/wp-content\/uploads\/2024\/05\/P1054-L.-Giesen.pdf. Accessed 7 Mar 2025"},{"issue":"2","key":"812_CR10","first-page":"59","volume":"6","author":"ML Balter","year":"2018","unstructured":"Balter, M. L., J. M. Leipheimer, A. I. Chen, A. Shrirao, T. J. Maguire, and M. L. Yarmush. Automated end-to-end blood testing at the point-of-care: Integration of robotic phlebotomy with downstream sample processing. Technology (Singap World Sci). 6(2):59\u201366, 2018.","journal-title":"Technology (Singap World Sci)."},{"issue":"917","key":"812_CR11","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1299\/transjsme.22-00262","volume":"89","author":"K Sagawa","year":"2023","unstructured":"Sagawa, K., T. Fujimoto, T. Koide, and C. Nagai. Development of automatic puncture method to simulated blood vessel in semi-transparent skin model by noncontact position estimation using IR cameras. Trans. JSME (in Japanese). 89(917):22\u201300262, 2023.","journal-title":"Trans. JSME (in Japanese)."},{"key":"812_CR12","doi-asserted-by":"publisher","first-page":"1754","DOI":"10.3390\/diagnostics13101754","volume":"13","author":"LD Noble","year":"2023","unstructured":"Noble, L. D., C. Dixon, A. Moran, C. Trottet, N. Majam, S. Ismail, V. T. Msolomba, K. Mathobela, J. G. Queval, L. E. Scott, and W. S. Stevens. Painless capillary blood collection: a rapid evaluation of the onflow device. Diagnostics. 13:1754, 2023. https:\/\/doi.org\/10.3390\/diagnostics13101754.","journal-title":"Diagnostics."},{"key":"812_CR13","doi-asserted-by":"publisher","unstructured":"S. Togashi, K. Takenaka, K. Uchida, T. Irie, T. Sakazume, and R. Miyake: Application of hybrid petri nets for a drawing blood flow from fingertip. In Proceedings of 8th International Conference on Simulation and Modeling Methodologies, Technologies and Applications (SIMULTECH 2018). 2018; 136\u2013143. https:\/\/dl.acm.org\/doi\/https:\/\/doi.org\/10.5220\/0006877701360143.","DOI":"10.5220\/0006877701360143"},{"issue":"4","key":"812_CR14","first-page":"490","volume":"44","author":"S Togashi","year":"2019","unstructured":"Togashi, S., K. Takenaka, T. Irie, M. Taki, Y. Akatsu, T. Sakazume, and K. Uchida. Investigation for increasing the volume of sampled blood in fingertip blood sampling. Clin. Lab. Sci. J. (in Japanese). 44(4):490, 2019.","journal-title":"Clin. Lab. Sci. J. (in Japanese)."},{"key":"812_CR15","unstructured":"Automatic Finger blood Sample Collection Device that Facilitates Creation of New Testing Service Solution. Hitachi Review 2022; 71(3): 342\u2013343"},{"issue":"4","key":"812_CR16","first-page":"484","volume":"45","author":"T Irie","year":"2020","unstructured":"Irie, T., S. Togashi, K. Takenaka, J. Hokari, S. Boku, Y. Akatsu, M. Taki, T. Sakazume, and K. Uchida. Prototype of automatic fingertip blood sampling system for use in hospital blood sampling room. Clin. Lab. Sci. J. (in Japanese). 45(4):484, 2020.","journal-title":"Clin. Lab. Sci. J. (in Japanese)."},{"issue":"4","key":"812_CR17","first-page":"507","volume":"46","author":"Y Sakamoto","year":"2021","unstructured":"Sakamoto, Y., T. Matsuno, H. Doi, T. Ando, E. Sugiura, T. Fujita, K. Saito, and H. Ito. Basic evaluation of automatic fingertip blood sampling system (part 1)\u2014Blood sampling volume and usability. Clin. Lab. Sci. J. (in Japanese). 46(4):507, 2021.","journal-title":"Clin. Lab. Sci. J. (in Japanese)."},{"issue":"4","key":"812_CR18","first-page":"507","volume":"46","author":"H Doi","year":"2021","unstructured":"Doi, H., T. Matsuno, Y. Sakamoto, T. Ando, E. Sugiura, T. Fujita, K. Saito, and H. Ito. Basic evaluation of automatic fingertip blood sampling system (part 2)\u2014Comparison of test results with upper arm vein blood sampling. Clin. Lab. Sci. J. (in Japanese). 46(4):507, 2021.","journal-title":"Clin. Lab. Sci. J. (in Japanese)."},{"issue":"8","key":"812_CR19","doi-asserted-by":"publisher","first-page":"1185","DOI":"10.1093\/ietisy\/e90-d.8.1185","volume":"90","author":"N Miura","year":"2007","unstructured":"Miura, N., A. Nagasaka, and T. Miyatake. Extraction of finger-vein patterns using maximum curvature points in image profiles. IEICE Trans. Inf. Syst. 90(8):1185\u20131194, 2007.","journal-title":"IEICE Trans. Inf. Syst."},{"issue":"5","key":"812_CR20","first-page":"62","volume":"67","author":"N Miura","year":"2018","unstructured":"Miura, N., K. Nakazaki, M. Fujio, and K. Takahashi. Technology and future prospects for finger vein authentication using visible-light cameras. Hitachi Rev. 67(5):62\u201370, 2018.","journal-title":"Hitachi Rev."},{"issue":"4","key":"812_CR21","first-page":"421","volume":"47","author":"K Takenaka","year":"2022","unstructured":"Takenaka, K., N. Tsukada, M. Kato, A. Nagasaka, J. Hokari, K. Takeda, and A. Yanagida. Prototype of automatic fingertip blood sampling system that determines the puncture position using the blood vessel image of the fingertip. Clin. Lab. Sci. J. 47(4):421, 2022.","journal-title":"Clin. Lab. Sci. J."},{"key":"812_CR22","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2024.104121","volume":"125","author":"K Takenaka","year":"2024","unstructured":"Takenaka, K., Y. Oyamada, M. Kato, A. Nagasaka, J. Hokari, T. Irie, N. Tsukada, and A. Yanagida. Prototype and evaluation of automatic fingertip-blood-sampling system that uses fingertip blood-vessel images to determine puncture position. Med. Eng. Phys.125:104121, 2024.","journal-title":"Med. Eng. Phys."},{"key":"812_CR23","unstructured":"Clinical and laboratory standards institute. GP42 Collection of capillary Blood Specimens. 7th ed. p.16"},{"key":"812_CR24","unstructured":"Digital Human Laboratory, AIST Home page, Japanese hand measurement data. https:\/\/www.airc.aist.go.jp\/dhrt\/hand\/data\/list.html. Accessed 7 Mar 2025"}],"container-title":["Cardiovascular Engineering and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13239-025-00812-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s13239-025-00812-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13239-025-00812-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,11]],"date-time":"2026-02-11T13:55:33Z","timestamp":1770818133000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s13239-025-00812-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,15]]},"references-count":24,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,2]]}},"alternative-id":["812"],"URL":"https:\/\/doi.org\/10.1007\/s13239-025-00812-y","relation":{},"ISSN":["1869-408X","1869-4098"],"issn-type":[{"value":"1869-408X","type":"print"},{"value":"1869-4098","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,15]]},"assertion":[{"value":"9 June 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 December 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Declaration of interests TI, SA, and TS are full-time employees of Hitachi High-tech Corp. KT and YO are full-time employees of Hitachi, Ltd. HD, TK, and HI are full-time employees of Fujita Health University. HD, TK, and HI do not receive a salary from the endowed course.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All participants provided their fully informed and written consent before assessment. This study was approved by the Fujita Health University Certified Review Board (CRB4180003).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical Approval"}},{"value":"Japan Registry of Clinical Trials (jRCTs042200104). Registered on March 3, 2021;","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Trial registration"}}]}}