{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T14:13:57Z","timestamp":1790691237933,"version":"4.1.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2019,10,24]],"date-time":"2019-10-24T00:00:00Z","timestamp":1571875200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,10,24]],"date-time":"2019-10-24T00:00:00Z","timestamp":1571875200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100004386","name":"Universiti Malaya","doi-asserted-by":"crossref","award":["PG211-2015B"],"award-info":[{"award-number":["PG211-2015B"]}],"id":[{"id":"10.13039\/501100004386","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Australas Phys Eng Sci Med"],"published-print":{"date-parts":[[2019,12]]},"DOI":"10.1007\/s13246-019-00809-7","type":"journal-article","created":{"date-parts":[[2019,10,25]],"date-time":"2019-10-25T18:24:32Z","timestamp":1572027872000},"page":"1099-1107","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["In vivo dosimetry using MOSkin detector during Cobalt-60 high-dose-rate (HDR) brachytherapy of skin cancer"],"prefix":"10.1007","volume":"42","author":[{"given":"Z.","family":"Jamalludin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W. L.","family":"Jong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G. F.","family":"Ho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A. B.","family":"Rosenfeld","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"N. M.","family":"Ung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,10,24]]},"reference":[{"key":"809_CR1","doi-asserted-by":"publisher","first-page":"1283","DOI":"10.1016\/j.ijrobp.2005.01.007","volume":"62","author":"F Perera","year":"2005","unstructured":"Perera F, Chisela F, Stitt L et al (2005) TLD skin dose measurements and acute and late effects after lumpectomy and high-dose-rate brachytherapy only for early breast cancer. Int J Radiat Oncol Biol Phys 62:1283\u20131290. \nhttps:\/\/doi.org\/10.1016\/j.ijrobp.2005.01.007","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"809_CR2","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/51\/14\/N01","author":"RA Kinhikar","year":"2006","unstructured":"Kinhikar RA, Sharma PK, Tambe CM et al (2006) Clinical application of a OneDoseTM MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast. Phys Med Biol. \nhttps:\/\/doi.org\/10.1088\/0031-9155\/51\/14\/N01","journal-title":"Phys Med Biol"},{"key":"809_CR3","doi-asserted-by":"publisher","first-page":"2693","DOI":"10.1118\/1.3429089","volume":"37","author":"JA Raffi","year":"2010","unstructured":"Raffi JA, Davis SD, Hammer CG et al (2010) Determination of exit skin dose for 192Ir intracavitary accelerated partial breast irradiation with thermoluminescent dosimeters. Med Phys 37:2693\u20132702. \nhttps:\/\/doi.org\/10.1118\/1.3429089","journal-title":"Med Phys"},{"key":"809_CR4","doi-asserted-by":"publisher","first-page":"1065","DOI":"10.1016\/j.brachy.2017.06.011","volume":"16","author":"S Aldelaijan","year":"2017","unstructured":"Aldelaijan S, Bekerat H, Buzurovic I et al (2017) Dose comparison between TG-43\u2013based calculations and radiochromic film measurements of the Freiburg flap applicator used for high-dose-rate brachytherapy treatments of skin lesions. Brachytherapy 16:1065\u20131072. \nhttps:\/\/doi.org\/10.1016\/j.brachy.2017.06.011","journal-title":"Brachytherapy"},{"key":"809_CR5","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1177\/153303460700600103","volume":"6","author":"RN Selvaraj","year":"2007","unstructured":"Selvaraj RN, Bhatnagar A, Beriwal S et al (2007) Breast skin doses from brachytherapy using MammoSite\u00ae HDR, intensity modulated radiation therapy, and tangential fields techniques. Technol Cancer Res Treat 6:17\u201322. \nhttps:\/\/doi.org\/10.1177\/153303460700600103","journal-title":"Technol Cancer Res Treat"},{"key":"809_CR6","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/aaac61","author":"JH Choi","year":"2018","unstructured":"Choi JH, Cutajar D, Metcalfe P, Downes S (2018) Application of MOSkin detector for in vivo dosimetry on total skin electron therapy (TSET). Biomed Phys Eng Express. \nhttps:\/\/doi.org\/10.1088\/2057-1976\/aaac61","journal-title":"Biomed Phys Eng Express"},{"key":"809_CR7","doi-asserted-by":"publisher","first-page":"3859","DOI":"10.1088\/0031-9155\/55\/13\/019","volume":"55","author":"N Hardcastle","year":"2010","unstructured":"Hardcastle N, Cutajar DL, Metcalfe PE et al (2010) In vivo real-time rectal wall dosimetry for prostate radiotherapy. Phys Med Biol 55:3859\u20133871. \nhttps:\/\/doi.org\/10.1088\/0031-9155\/55\/13\/019","journal-title":"Phys Med Biol"},{"key":"809_CR8","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1016\/j.radmeas.2014.05.010","volume":"71","author":"C Tenconi","year":"2014","unstructured":"Tenconi C, Carrara M, Borroni M et al (2014) TRUS-probe integrated MOSkin detectors for rectal wall in vivo dosimetry in HDR brachytherapy: in phantom feasibility study. Radiat Meas 71:379\u2013383. \nhttps:\/\/doi.org\/10.1016\/j.radmeas.2014.05.010","journal-title":"Radiat Meas"},{"key":"809_CR9","doi-asserted-by":"publisher","first-page":"1466","DOI":"10.1016\/j.ejmp.2016.10.022","volume":"32","author":"WL Jong","year":"2016","unstructured":"Jong WL, Ung NM, Wong JHD et al (2016) In vivo skin dose measurement using MOSkin detectors in tangential breast radiotherapy. Phys Med 32:1466\u20131474. \nhttps:\/\/doi.org\/10.1016\/j.ejmp.2016.10.022","journal-title":"Phys Med"},{"key":"809_CR10","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1016\/j.radphyschem.2017.11.021","volume":"144","author":"WL Jong","year":"2018","unstructured":"Jong WL, Ung NM, Tiong AHL et al (2018) Characterisation of a MOSFET-based detector for dose measurement under megavoltage electron beam radiotherapy. Radiat Phys Chem 144:76\u201384. \nhttps:\/\/doi.org\/10.1016\/j.radphyschem.2017.11.021","journal-title":"Radiat Phys Chem"},{"key":"809_CR11","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1016\/j.radonc.2015.12.022","volume":"118","author":"M Carrara","year":"2016","unstructured":"Carrara M, Tenconi C, Rossi G et al (2016) In vivo rectal wall measurements during HDR prostate brachytherapy with MOSkin dosimeters integrated on a trans-rectal US probe: comparison with planned and reconstructed doses. Radiother Oncol 118:148\u2013153. \nhttps:\/\/doi.org\/10.1016\/j.radonc.2015.12.022","journal-title":"Radiother Oncol"},{"key":"809_CR12","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1016\/j.ejmp.2017.05.003","volume":"41","author":"M Carrara","year":"2017","unstructured":"Carrara M, Romanyukha A, Tenconi C et al (2017) Clinical application of MOSkin dosimeters to rectal wall in vivo dosimetry in gynecological HDR brachytherapy. Phys Med 41:5\u201312. \nhttps:\/\/doi.org\/10.1016\/j.ejmp.2017.05.003","journal-title":"Phys Med"},{"key":"809_CR13","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1080\/00223131.2008.10875895","volume":"45","author":"K Ian","year":"2008","unstructured":"Ian K, Andrew H, Michael L et al (2008) Measurement of rectal dose during HDR brachytherapy using the new MOSkin dosimeter. J Nucl Sci Technol 45:481\u2013484. \nhttps:\/\/doi.org\/10.1080\/00223131.2008.10875895","journal-title":"J Nucl Sci Technol"},{"key":"809_CR14","doi-asserted-by":"publisher","first-page":"2007","DOI":"10.1118\/1.2736288","volume":"34","author":"Z Qi","year":"2007","unstructured":"Qi Z, Deng X, Huang S et al (2007) Verification of the plan dosimetry for high dose rate brachytherapy using metal\u2013oxide-semiconductor field effect transistor detectors. Int J Med Phys Res Pract 34:2007\u20132013. \nhttps:\/\/doi.org\/10.1118\/1.2736288","journal-title":"Int J Med Phys Res Pract"},{"key":"809_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.ejmp.2019.01.010","volume":"58","author":"Z Jamalludin","year":"2019","unstructured":"Jamalludin Z, Jong WL, Abdul Malik R et al (2019) Characterization of MOSkin detector for in vivo dose verification during cobalt-60 high dose-rate intracavitary brachytherapy. Phys Med 58:1\u20137. \nhttps:\/\/doi.org\/10.1016\/j.ejmp.2019.01.010","journal-title":"Phys Med"},{"key":"809_CR16","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1120\/jacmp.v15i5.4869","volume":"15","author":"WL Jong","year":"2014","unstructured":"Jong WL, Wong JHD, Ung NM et al (2014) Characterization of MOSkin detector for in vivo skin dose measurement during megavoltage radiotherapy. J Appl Clin Med Phys 15:120\u2013132. \nhttps:\/\/doi.org\/10.1120\/jacmp.v15i5.4869","journal-title":"J Appl Clin Med Phys"},{"key":"809_CR17","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1016\/S0360-3016(99)00330-2","volume":"46","author":"S Nag","year":"2000","unstructured":"Nag S, Gupta N (2000) A simple method of obtaining equivalent doses for use in HDR brachytherapy. Int J Radiat Oncol Biol Phys 46:507\u2013513. \nhttps:\/\/doi.org\/10.1016\/S0360-3016(99)00330-2","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"809_CR18","doi-asserted-by":"publisher","first-page":"1245","DOI":"10.1118\/1.598619","volume":"26","author":"XA Li","year":"1999","unstructured":"Li XA, Chu JCH, Chen W, Zusag T (1999) Dose enhancement by a thin foil of high-Z material: a Monte Carlo study. Med Phys 26:1245\u20131251. \nhttps:\/\/doi.org\/10.1118\/1.598619","journal-title":"Med Phys"},{"key":"809_CR19","doi-asserted-by":"publisher","first-page":"32","DOI":"10.5114\/jcb.2011.21041","volume":"3","author":"F Lliso","year":"2011","unstructured":"Lliso F, Granero D, Perez-Calatayud J et al (2011) Dosimetric evaluation of internal shielding in a high dose rate skin applicator. J Contemp Brachytherapy 3:32\u201335. \nhttps:\/\/doi.org\/10.5114\/jcb.2011.21041","journal-title":"J Contemp Brachytherapy"},{"key":"809_CR20","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1088\/0952-4746\/34\/2\/297","volume":"34","author":"C Candela-Juan","year":"2014","unstructured":"Candela-Juan C, Granero D, Vijande J et al (2014) Dosimetric perturbations of a lead shield for surface and interstitial high-dose-rate brachytherapy. J Radiol Prot 34:297\u2013311. \nhttps:\/\/doi.org\/10.1088\/0952-4746\/34\/2\/297","journal-title":"J Radiol Prot"},{"key":"809_CR21","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1120\/jacmp.v16i5.5589","volume":"16","author":"EA Alhakeem","year":"2015","unstructured":"Alhakeem EA, AlShaikh S, Rosenfeld AB, Zavgorodni SF (2015) Comparative evaluation of modern dosimetry techniques near low- and high-density heterogeneities. J Appl Clin Med Phys 16:142\u2013158. \nhttps:\/\/doi.org\/10.1120\/jacmp.v16i5.5589","journal-title":"J Appl Clin Med Phys"},{"key":"809_CR22","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.ejmp.2017.08.011","volume":"42","author":"AB Rosenfeld","year":"2017","unstructured":"Rosenfeld AB, Wong JHD, Jong WL et al (2017) Dosimetric evaluation near lung and soft tissue interface region during respiratory-gated and non-gated radiotherapy: a moving phantom study. Phys Med 42:39\u201346. \nhttps:\/\/doi.org\/10.1016\/j.ejmp.2017.08.011","journal-title":"Phys Med"},{"key":"809_CR23","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/j.brachy.2017.08.013","volume":"17","author":"M Carrara","year":"2018","unstructured":"Carrara M, Cutajar D, Alnaghy S et al (2018) Semiconductor real-time quality assurance dosimetry in brachytherapy. Brachytherapy 17:133\u2013145. \nhttps:\/\/doi.org\/10.1016\/j.brachy.2017.08.013","journal-title":"Brachytherapy"},{"key":"809_CR24","doi-asserted-by":"publisher","first-page":"S762","DOI":"10.1016\/j.ijrobp.2010.07.1765","volume":"78","author":"P Metcalfe","year":"2010","unstructured":"Metcalfe P, Kelly A, Hardcastle N et al (2010) Surface dosimetry for breast radiotherapy using MOSkins to measure the influence of immobilization cast material. Int J Radiat Oncol Biol Phys 78:S762\u2013S763. \nhttps:\/\/doi.org\/10.1016\/j.ijrobp.2010.07.1765","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"809_CR25","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1016\/j.ejmp.2018.09.009","volume":"54","author":"ZS Al-Rahbi","year":"2018","unstructured":"Al-Rahbi ZS, Cutajar DL, Metcalfe P, Rosenfeld AB (2018) Dosimetric effects of brass mesh bolus on skin dose and dose at depth for postmastectomy chest wall irradiation. Phys Med 54:84\u201393. \nhttps:\/\/doi.org\/10.1016\/j.ejmp.2018.09.009","journal-title":"Phys Med"},{"key":"809_CR26","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1007\/s13246-012-0153-1","volume":"35","author":"H Alnawaf","year":"2012","unstructured":"Alnawaf H, Butson M, Yu PKN (2012) Measurement and effects of MOSkin detectors on skin dose during high energy radiotherapy treatment. Australas Phys Eng Sci Med 35:321\u2013328. \nhttps:\/\/doi.org\/10.1007\/s13246-012-0153-1","journal-title":"Australas Phys Eng Sci Med"},{"key":"809_CR27","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1016\/j.ijrobp.2010.12.023","volume":"81","author":"LW Cuttino","year":"2011","unstructured":"Cuttino LW, Heffernan J, Vera R et al (2011) Association between maximal skin dose and breast brachytherapy outcome: a proposal for more rigorous dosimetric constraints. Int J Radiat Oncol Biol Phys 81:173\u2013177. \nhttps:\/\/doi.org\/10.1016\/j.ijrobp.2010.12.023","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"809_CR28","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1016\/j.ijrobp.2013.05.039","volume":"88","author":"JA Vargo","year":"2014","unstructured":"Vargo JA, Verma V, Kim H et al (2014) Extended (5-year) outcomes of accelerated partial breast irradiation using MammoSite balloon brachytherapy: patterns of failure, patient selection, and dosimetric correlates for late toxicity. Int J Radiat Oncol Biol Phys 88:285\u2013291. \nhttps:\/\/doi.org\/10.1016\/j.ijrobp.2013.05.039","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"809_CR29","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.radonc.2013.11.002","volume":"110","author":"C Kirisits","year":"2014","unstructured":"Kirisits C, Rivard MJ, Baltas D et al (2014) Review of clinical brachytherapy uncertainties: analysis guidelines of GEC-ESTRO and the AAPM. Radiother Oncol 110:199\u2013212. \nhttps:\/\/doi.org\/10.1016\/j.radonc.2013.11.002","journal-title":"Radiother Oncol"},{"key":"809_CR30","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2019.01.010","author":"Z Jamalludin","year":"2019","unstructured":"Jamalludin Z, Jong WL, Abdul Malik R et al (2019) Characterization of MOSkin detector for in vivo dose verification during cobalt-60 high dose-rate intracavitary brachytherapy. Phys Med. \nhttps:\/\/doi.org\/10.1016\/j.ejmp.2019.01.010","journal-title":"Phys Med"}],"container-title":["Australasian Physical &amp; Engineering Sciences in Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-019-00809-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s13246-019-00809-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-019-00809-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,10,22]],"date-time":"2020-10-22T23:24:54Z","timestamp":1603409094000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s13246-019-00809-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10,24]]},"references-count":30,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["809"],"URL":"https:\/\/doi.org\/10.1007\/s13246-019-00809-7","relation":{},"ISSN":["0158-9938","1879-5447"],"issn-type":[{"value":"0158-9938","type":"print"},{"value":"1879-5447","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,10,24]]},"assertion":[{"value":"15 April 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 October 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 October 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"All procedures performed in studies involving human participants were in accordance with the Ethical Standards of the University of Malaya Medical Centre Research Committee (MECID No. 2017123\u20134840) and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}