{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T16:03:14Z","timestamp":1786982594264,"version":"build-2736575974"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2020,7,6]],"date-time":"2020-07-06T00:00:00Z","timestamp":1593993600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,7,6]],"date-time":"2020-07-06T00:00:00Z","timestamp":1593993600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Phys Eng Sci Med"],"published-print":{"date-parts":[[2020,9]]},"DOI":"10.1007\/s13246-020-00892-1","type":"journal-article","created":{"date-parts":[[2020,7,6]],"date-time":"2020-07-06T04:03:46Z","timestamp":1594008226000},"page":"959-972","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["Investigation of thermal aspects of high-speed drilling of bone by theoretical and experimental approaches"],"prefix":"10.1007","volume":"43","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1882-8450","authenticated-orcid":false,"given":"Ehsan","family":"Shakouri","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Milad","family":"Ghorbani Nezhad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pezhman","family":"Ghorbani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fariba","family":"Khosravi-Nejad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,7,6]]},"reference":[{"issue":"4","key":"892_CR1","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1016\/j.bjoms.2004.11.007","volume":"43","author":"W Allan","year":"2005","unstructured":"Allan W, Williams ED, Kerawala CJ (2005) Effects of repeated drill use on temperature of bone during preparation for osteosynthesis self-tapping screws. Br J Oral Maxillofac Surg 43(4):314\u2013319","journal-title":"Br J Oral Maxillofac Surg"},{"issue":"1","key":"892_CR2","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1007\/s00402-007-0427-3","volume":"128","author":"G Augustin","year":"2008","unstructured":"Augustin G, Davila S, Mihoci K, Udiljak T, Vedrina DS, Antabak A (2008) Thermal osteonecrosis and bone drilling parameters revisited. Arch Orthop Trauma Surg 128(1):71\u201377","journal-title":"Arch Orthop Trauma Surg"},{"issue":"10","key":"892_CR3","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1016\/S1350-4533(01)00016-9","volume":"22","author":"KN Bachus","year":"2000","unstructured":"Bachus KN, Rondina MT, Hutchinson DT (2000) The effects of drilling force on cortical temperatures and their duration: an in vitro study. Med Eng Phys 22(10):685\u2013691","journal-title":"Med Eng Phys"},{"issue":"93","key":"892_CR4","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1016\/S0924-0136(99)00155-7","volume":"92","author":"MT Hillery","year":"1999","unstructured":"Hillery MT, Shuaib I (1999) Temperature effects in the drilling of human and bovine bone. J Mater Process Technol 92(93):302\u2013308","journal-title":"J Mater Process Technol"},{"issue":"6","key":"892_CR5","doi-asserted-by":"crossref","first-page":"1076","DOI":"10.1016\/j.jbiomech.2011.12.012","volume":"45","author":"J Lee","year":"2012","unstructured":"Lee J, Gozen BA, Ozdoganlar OB (2012) Modeling and experimentation of bone drilling forces. J Biomech 45(6):1076\u20131083","journal-title":"J Biomech"},{"issue":"10","key":"892_CR6","doi-asserted-by":"crossref","first-page":"1221","DOI":"10.1016\/j.medengphy.2011.05.013","volume":"33","author":"F Karaca","year":"2011","unstructured":"Karaca F, Aksakal B, Kom M (2011) Influence of orthopaedic drilling parameters on temperature and histopathology of bovine tibia: an in vitro study. Med Eng Phys 33(10):1221\u20131227","journal-title":"Med Eng Phys"},{"issue":"2","key":"892_CR7","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1177\/0954411918819113","volume":"233","author":"MFA Akhbar","year":"2018","unstructured":"Akhbar MFA, Yusoff AR (2018) Drilling of bone: effect of drill bit geometries on thermal osteonecrosis risk regions. Proc Inst Mech Eng H 233(2):207\u2013218","journal-title":"Proc Inst Mech Eng H"},{"issue":"2","key":"892_CR8","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1177\/0954411915573064","volume":"229","author":"E Shakouri","year":"2015","unstructured":"Shakouri E, Sadeghi MH, Karafi MR, Maerefat M, Farzin M (2015) An in vitro study of thermal necrosis in ultrasonic-assisted drilling of bone. Proc Inst Mech Eng H 229(2):137\u2013149","journal-title":"Proc Inst Mech Eng H"},{"key":"892_CR9","doi-asserted-by":"crossref","first-page":"312","DOI":"10.5099\/aj090400312","volume":"1","author":"K Alam","year":"2009","unstructured":"Alam K, Mitrofanov AV, Silberschmidt VV (2009) Measurements of surface roughness in conventional and ultrasonically assisted bone drilling. Am J Biomed Sci 1:312\u2013320","journal-title":"Am J Biomed Sci"},{"key":"892_CR10","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.medengphy.2018.12.019","volume":"65","author":"Z Sun","year":"2019","unstructured":"Sun Z, Wang Y, Xu K, Zhou G, Liang C, Qu J (2019) Experimental investigations of drilling temperature of high-energy ultrasonically assisted bone drilling. Med Eng Phys 65:1\u20137","journal-title":"Med Eng Phys"},{"issue":"2","key":"892_CR11","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1016\/j.medengphy.2010.10.003","volume":"33","author":"K Alam","year":"2011","unstructured":"Alam K, Mitrofanov AV, Silberschmidt VV (2011) Experimental investigations of forces and torque in conventional and ultrasonically-assisted drilling of cortical bone. Med Eng Phys 33(2):234\u2013239","journal-title":"Med Eng Phys"},{"key":"892_CR12","doi-asserted-by":"publisher","DOI":"10.1177\/0954411919898301","author":"V Gupta","year":"2020","unstructured":"Gupta V, Singh RP, Pandey PM, Gupta R (2020) In vitro comparison of conventional surgical and rotary ultrasonic bone drilling techniques. Proc Inst Mech Eng H. https:\/\/doi.org\/10.1177\/0954411919898301","journal-title":"Proc Inst Mech Eng H"},{"issue":"4","key":"892_CR13","doi-asserted-by":"crossref","first-page":"753","DOI":"10.1080\/13102818.2015.1034176","volume":"29","author":"K Alam","year":"2015","unstructured":"Alam K, Hassan E, Bahadur I (2015) Experimental measurements of temperatures in ultrasonically assisted drilling of cortical bone. Biotechnol Biotechnol Equip 29(4):753\u2013757","journal-title":"Biotechnol Biotechnol Equip"},{"issue":"9","key":"892_CR14","doi-asserted-by":"crossref","first-page":"1549","DOI":"10.1177\/0954405416673115","volume":"232","author":"V Gupta","year":"2018","unstructured":"Gupta V, Pandey PM (2018) An in-vitro study of cutting force and torque during rotary ultrasonic bone drilling. Proc Inst Mech Eng B 232(9):1549\u20131560","journal-title":"Proc Inst Mech Eng B"},{"key":"892_CR15","doi-asserted-by":"crossref","first-page":"1408","DOI":"10.1016\/j.medengphy.2014.04.007","volume":"36","author":"Y Wang","year":"2014","unstructured":"Wang Y, Cao M, Zhao X, Zhu G, McClean C, Zhao Y, Fan Y (2014) Experimental investigations and finite element simulation of cutting heat in vibrational and conventional drilling of cortical bone. Med Eng Phys 36:1408\u20131415","journal-title":"Med Eng Phys"},{"issue":"1","key":"892_CR16","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1177\/0954411917742944","volume":"232","author":"E Shakouri","year":"2018","unstructured":"Shakouri E, Haghighi Hassanalideh H, Gholampour S (2018) Experimental investigation of temperature rise in bone drilling with cooling: a comparison between modes of without cooling, internal gas cooling, and external liquid cooling. Proc Inst Mech Eng H 232(1):45\u201353","journal-title":"Proc Inst Mech Eng H"},{"issue":"4","key":"892_CR17","doi-asserted-by":"crossref","first-page":"687","DOI":"10.3233\/THC-181246","volume":"26","author":"S Gholampour","year":"2018","unstructured":"Gholampour S, Shakouri E, Deh HHH (2018) Effect of drilling direction and depth on thermal necrosis during tibia drilling: an in vitro study. Technol Health Care 26(4):687\u2013697","journal-title":"Technol Health Care"},{"issue":"3","key":"892_CR18","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1111\/j.1600-0501.2008.01643.x","volume":"20","author":"BC Sener","year":"2009","unstructured":"Sener BC, Dergin G, Gursoy B, Kelesoglu E, Slih I (2009) Effects of irrigation temperature on heat control in vitro at different drilling depths. Clin Oral Implant Res 20(3):294\u2013298","journal-title":"Clin Oral Implant Res"},{"issue":"9","key":"892_CR19","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1177\/0954411918790777","volume":"232","author":"E Shakouri","year":"2018","unstructured":"Shakouri E, Abbasi M (2018) Investigation of cutting quality and surface roughness in abrasive water jet machining of bone. Proc Inst Mech Eng H 232(9):850\u2013861","journal-title":"Proc Inst Mech Eng H"},{"key":"892_CR20","doi-asserted-by":"crossref","DOI":"10.1007\/978-3-642-55776-7","volume-title":"Manufacturing technologies for machines of the future","author":"AI Dashchenko","year":"2003","unstructured":"Dashchenko AI (2003) Manufacturing technologies for machines of the future. Springer, Berlin"},{"key":"892_CR21","volume-title":"Fundamentals of machining of metallic materials","author":"W Grzesik","year":"2010","unstructured":"Grzesik W (2010) Fundamentals of machining of metallic materials. WNT, Warsaw"},{"issue":"4","key":"892_CR22","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1016\/j.clinbiomech.2011.10.010","volume":"27","author":"G Augustin","year":"2012","unstructured":"Augustin G, Zigman T, Davila S, Udilljak T, Staroveski T, Brezak D, Babic S (2012) Cortical bone drilling and thermal osteonecrosis. Clin Biomech 27(4):313\u2013325","journal-title":"Clin Biomech"},{"issue":"3","key":"892_CR23","first-page":"342","volume":"12","author":"MB Abouzgia","year":"1997","unstructured":"Abouzgia MB, James DF (1997) Temperature rise during drilling through bone. Int J Oral Maxillofac Implants 12(3):342\u2013353","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"5","key":"892_CR24","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1016\/S0901-5027(06)80040-8","volume":"25","author":"MB Abouzgia","year":"1996","unstructured":"Abouzgia MB, Symington JM (1996) Effect of drill speed on bone temperature. Int J Oral Maxillofac Surg 25(5):394\u2013399","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"3","key":"892_CR25","first-page":"103","volume":"2","author":"T Udiljak","year":"2007","unstructured":"Udiljak T, Ciglar D, Skoric S (2007) Investigation into bone drilling and thermal bone necrosis. Adv Prod Eng Manag 2(3):103\u2013112","journal-title":"Adv Prod Eng Manag"},{"issue":"4","key":"892_CR26","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1177\/0954411914524933","volume":"228","author":"E Shakouri","year":"2014","unstructured":"Shakouri E, Sadeghi MH, Maerefat M, Shajari S (2014) Experimental and analytical investigation of the thermal necrosis in high-speed drilling of bone. Proc Inst Mech Eng H 228(4):330\u2013341","journal-title":"Proc Inst Mech Eng H"},{"issue":"6","key":"892_CR27","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1177\/0954411919845730","volume":"233","author":"E Shakouri","year":"2019","unstructured":"Shakouri E, Mirfallah P (2019) Infrared thermography of high-speed grinding of bone in skull base neurosurgery. Proc Inst Mech Eng H 233(6):648\u2013656","journal-title":"Proc Inst Mech Eng H"},{"issue":"2","key":"892_CR28","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/0021-9290(74)90051-7","volume":"7","author":"CH Jacobs","year":"1974","unstructured":"Jacobs CH, Pope MH, Berry JT, Hoaglund F (1974) A study of the bone machining process-orthogonal cutting. J Biomech 7(2):131\u2013136","journal-title":"J Biomech"},{"issue":"3","key":"892_CR29","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1115\/1.3138679","volume":"109","author":"WR Krause","year":"1987","unstructured":"Krause WR (1987) Orthogonal bone cutting: saw design and operating characteristics. J Biomech Eng 109(3):263\u2013271","journal-title":"J Biomech Eng"},{"issue":"3","key":"892_CR30","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1115\/1.1535190","volume":"125","author":"SRH Davidson","year":"2003","unstructured":"Davidson SRH, James DF (2003) Drilling in bone: modeling heat generation and temperature distribution. J Biomech Eng 125(3):305\u2013314","journal-title":"J Biomech Eng"},{"key":"892_CR31","doi-asserted-by":"crossref","DOI":"10.1007\/978-3-030-26047-7","volume-title":"Metal and bone drilling\u2014the thermal aspects","author":"AJ Shih","year":"2019","unstructured":"Shih AJ, Tai BL, Li R (2019) Metal and bone drilling\u2014the thermal aspects. Springer, Cham"},{"issue":"4","key":"892_CR32","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1177\/0954411919832038","volume":"233","author":"E Shakouri","year":"2019","unstructured":"Shakouri E, Mobini A (2019) Airbag deployment: infrared thermography and evaluation of thermal damage. Proc Inst Mech Eng H 233(4):424\u2013431","journal-title":"Proc Inst Mech Eng H"},{"issue":"5","key":"892_CR33","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1007\/s00402-008-0630-x","volume":"129","author":"G Augustin","year":"2009","unstructured":"Augustin G, Davila S, Udiljak T, Vedrina DS, Bagatin D (2009) Determination of spatial distribution of increase in bone temperature during drilling by infrared thermography: preliminary report. Arch Orthop Trauma Surg 129(5):703\u2013709","journal-title":"Arch Orthop Trauma Surg"},{"issue":"4","key":"892_CR34","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1111\/j.1708-8208.2009.00209.x","volume":"13","author":"A Scarano","year":"2011","unstructured":"Scarano A, Piattelli A, Assenza B, Carinci F, Donato LD, Romani GL, Merla A (2011) Infrared thermographic evaluation of temperature modifications induced during implant site preparation with cylindrical versus conical drills. Clin Implant Dent Relat Res 13(4):319\u2013323","journal-title":"Clin Implant Dent Relat Res"},{"key":"892_CR35","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1007\/s13246-020-00842-x","volume":"43","author":"E Shakouri","year":"2020","unstructured":"Shakouri E, Ghorbani Nezhad M (2020) An in vitro study of bone drilling: infrared thermography and evaluation of thermal changes of bone and drill bit. Phys Eng Sci Med 43:247\u2013257","journal-title":"Phys Eng Sci Med"},{"issue":"9","key":"892_CR36","first-page":"822","volume":"5","author":"S Peev","year":"2016","unstructured":"Peev S, Sabeva E (2016) Assessment of the heat generation at the marginal bone area during the implant insertion using infrared thermography (experimental study). Sci Res (IJSR) 5(9):822\u2013825","journal-title":"Sci Res (IJSR)"},{"issue":"1","key":"892_CR37","first-page":"1","volume":"3","author":"G Dua","year":"2017","unstructured":"Dua G, Mulaveesala R (2017) Infrared thermography for detection and evaluation of bone density variation by non-stationary thermal wave imaging. Biomed Phys Eng Express 3(1):1\u20136","journal-title":"Biomed Phys Eng Express"},{"key":"892_CR38","unstructured":"Emissivity coefficients of some common materials. https:\/\/www.engineeringtoolbox.com"},{"key":"892_CR39","doi-asserted-by":"crossref","first-page":"128","DOI":"10.4028\/www.scientific.net\/AMR.188.128","volume":"188","author":"P Mathew","year":"2011","unstructured":"Mathew P (2011) Prediction of high speed machining cutting forces using a variable flow stress machining theory. Adv Mater Res 188:128\u2013133","journal-title":"Adv Mater Res"},{"key":"892_CR40","volume-title":"Metal cutting","author":"E Trent","year":"2000","unstructured":"Trent E, Wright P (2000) Metal cutting. Butterworth-Heinemann, Philadelphia"}],"container-title":["Physical and Engineering Sciences in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-020-00892-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s13246-020-00892-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-020-00892-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,5]],"date-time":"2021-07-05T19:32:03Z","timestamp":1625513523000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s13246-020-00892-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,6]]},"references-count":40,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020,9]]}},"alternative-id":["892"],"URL":"https:\/\/doi.org\/10.1007\/s13246-020-00892-1","relation":{},"ISSN":["2662-4729","2662-4737"],"issn-type":[{"value":"2662-4729","type":"print"},{"value":"2662-4737","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7,6]]},"assertion":[{"value":"22 March 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 June 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 July 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The author(s) declared no potential conflicts of interest with respect to the research, authorship, and\/or publication of this article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}