{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T18:51:01Z","timestamp":1793127061119,"version":"4.5.0"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2021,9,16]],"date-time":"2021-09-16T00:00:00Z","timestamp":1631750400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,9,16]],"date-time":"2021-09-16T00:00:00Z","timestamp":1631750400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"name":"Herston Biofabrication Institute"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Phys Eng Sci Med"],"published-print":{"date-parts":[[2021,12]]},"DOI":"10.1007\/s13246-021-01054-7","type":"journal-article","created":{"date-parts":[[2021,9,16]],"date-time":"2021-09-16T10:12:01Z","timestamp":1631787121000},"page":"1187-1199","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Determining tolerance levels for quality assurance of 3D printed bolus for modulated arc radiotherapy of the nose"],"prefix":"10.1007","volume":"44","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2136-6138","authenticated-orcid":false,"given":"T.","family":"Kairn","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Talkhani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P. H.","family":"Charles","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B.","family":"Chua","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C. Y.","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A. G.","family":"Livingstone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S. K.","family":"Maxwell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.","family":"Poroa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E.","family":"Simpson-Page","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E.","family":"Spelleken","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Vo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S. B.","family":"Crowe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,9,16]]},"reference":[{"issue":"3","key":"1054_CR1","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1016\/j.meddos.2013.02.007","volume":"38","author":"V Vyas","year":"2013","unstructured":"Vyas V, Palmer L, Mudge R, Jiang R, Fleck A, Schaly B, Osei E, Charland P (2013) On bolus for megavoltage photon and electron radiation therapy. Med Dosim 38(3):268\u2013273","journal-title":"Med Dosim"},{"issue":"4","key":"1054_CR2","doi-asserted-by":"publisher","first-page":"287","DOI":"10.18869\/acadpub.ijrr.14.4.287","volume":"14","author":"M \u0141ukowiak","year":"2016","unstructured":"\u0141ukowiak M, Boehlke M, Matias D, Jezierska K, Piatek-Hnat M, Lewocki M, Podraza W, El Fray M, Kot W (2016) Use of a 3D printer to create a bolus for patients undergoing tele-radiotherapy. Int J Radiat Res 14(4):287\u2013295","journal-title":"Int J Radiat Res"},{"issue":"1","key":"1054_CR3","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1002\/acm2.12013","volume":"18","author":"M \u0141ukowiak","year":"2017","unstructured":"\u0141ukowiak M, Jezierska K, Boehlke M, Wiecko M, \u0141ukowiak A, Podraza W, Lewocki M, Masoj\u0107 B, Falco M (2017) Utilization of a 3D printer to fabricate boluses used for electron therapy of skin lesions of the eye canthi. J Appl Clin Med Phys 18(1):76\u201381","journal-title":"J Appl Clin Med Phys"},{"issue":"9","key":"1054_CR4","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1002\/acm2.12703","volume":"20","author":"DK Sasaki","year":"2019","unstructured":"Sasaki DK, McGeachy P, Alpuche Aviles JE, McCurdy B, Koul R, Dubey A (2019) A modern mold room: meshing 3D surface scanning, digital design, and 3D printing with bolus fabrication. J Appl Clin Med Phys 20(9):78\u201385","journal-title":"J Appl Clin Med Phys"},{"issue":"12","key":"1054_CR5","doi-asserted-by":"publisher","first-page":"e0168063","DOI":"10.1371\/journal.pone.0168063","volume":"11","author":"SY Park","year":"2016","unstructured":"Park SY, Choi CH, Park JM, Chun M, Han JH, Kim JI (2016) A patient-specific polylactic acid bolus made by a 3D printer for breast cancer radiation therapy. PLoS ONE 11(12):e0168063","journal-title":"PLoS ONE"},{"issue":"1","key":"1054_CR6","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1016\/j.radonc.2016.07.011","volume":"121","author":"RA Canters","year":"2016","unstructured":"Canters RA, Lips IM, Wendling M, Kusters M, van Zeeland M, Gerritsen RM, Poortmans P, Verhoef CG (2016) Clinical implementation of 3D printing in the construction of patient specific bolus for electron beam radiotherapy for non-melanoma skin cancer. Radiother Oncol 121(1):148\u2013153","journal-title":"Radiother Oncol"},{"issue":"3","key":"1054_CR7","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1016\/j.canrad.2015.11.003","volume":"20","author":"JW Park","year":"2016","unstructured":"Park JW, Yea JW (2016) Three-dimensional customized bolus for intensity-modulated radiotherapy in a patient with Kimura\u2019s disease involving the auricle. Cancer\/Radiother 20(3):205\u2013209","journal-title":"Cancer\/Radiother"},{"issue":"10","key":"1054_CR8","doi-asserted-by":"publisher","first-page":"e110746","DOI":"10.1371\/journal.pone.0110746","volume":"9","author":"SW Kim","year":"2014","unstructured":"Kim SW, Shin HJ, Kay CS, Son SH (2014) A customized bolus produced using a 3-dimensional printer for radiotherapy. PLoS ONE 9(10):e110746","journal-title":"PLoS ONE"},{"key":"1054_CR9","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1016\/j.ejmp.2017.06.004","volume":"39","author":"R Ricotti","year":"2017","unstructured":"Ricotti R, Ciardo D, Pansini F, Bazani A, Comi S, Spoto R, Noris S, Cattani F, Baroni G, Orecchia R, Vavassori A (2017) Dosimetric characterization of 3D printed bolus at different infill percentage for external photon beam radiotherapy. Phys Med 39:25\u201332","journal-title":"Phys Med"},{"issue":"3","key":"1054_CR10","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1016\/S1350-4487(99)00276-0","volume":"32","author":"MJ Butson","year":"2000","unstructured":"Butson MJ, Cheung T, Yu P, Metcalfe P (2000) Effects on skin dose from unwanted air gaps under bolus in photon beam radiotherapy. Radiat Meas 32(3):201\u2013204","journal-title":"Radiat Meas"},{"issue":"7","key":"1054_CR11","doi-asserted-by":"publisher","first-page":"1251","DOI":"10.4236\/jct.2013.47147","volume":"4","author":"Y Khan","year":"2013","unstructured":"Khan Y, Villarreal-Barajas JE, Udowicz M, Sinha R, Muhammad W, Abbasi AN, Hussain A (2013) Clinical and dosimetric implications of air gaps between bolus and skin surface during radiation therapy. J Cancer Ther 4(7):1251\u20131255","journal-title":"J Cancer Ther"},{"issue":"4","key":"1054_CR12","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1120\/jacmp.v15i4.4831","volume":"15","author":"S Su","year":"2014","unstructured":"Su S, Moran K, Robar JL (2014) Design and production of 3D printed bolus for electron radiation therapy. J Appl Clin Med Phys 15(4):194\u2013211","journal-title":"J Appl Clin Med Phys"},{"issue":"2","key":"1054_CR13","doi-asserted-by":"publisher","first-page":"E697","DOI":"10.1016\/j.ijrobp.2017.06.2282","volume":"99","author":"P McGeachy","year":"2017","unstructured":"McGeachy P, Sasaki DK, Harris C, Sharma AM, Dubey A (2017) Quality assurance tests for 3D printed bolus used in radiation therapy. Int J Radiat Oncol Biol Phys 99(2):E697\u2013E698","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"3","key":"1054_CR14","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1120\/jacmp.v16i3.5247","volume":"16","author":"S Burleson","year":"2015","unstructured":"Burleson S, Baker J, Hsia AT, Xu Z (2015) Use of 3D printers to create a patient-specific 3D bolus for external beam therapy. J Appl Clin Med Phys 16(3):166\u2013178","journal-title":"J Appl Clin Med Phys"},{"issue":"3","key":"1054_CR15","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1120\/jacmp.v16i3.4959","volume":"16","author":"W Zou","year":"2015","unstructured":"Zou W, Fisher T, Zhang M, Kim L, Chen T, Narra V, Swann B, Singh R, Siderit R, Yin L, Teo BKK (2015) Potential of 3D printing technologies for fabrication of electron bolus and proton compensators. J Appl Clin Med Phys 16(3):90\u201398","journal-title":"J Appl Clin Med Phys"},{"issue":"4","key":"1054_CR16","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1120\/jacmp.v4i4.2503","volume":"4","author":"RJ Kudchadker","year":"2003","unstructured":"Kudchadker RJ, Antolak JA, Morrison WH, Wong PF, Hogstrom KR (2003) Utilization of custom electron bolus in head and neck radiotherapy. J Appl Clin Med Phys 4(4):321\u2013333","journal-title":"J Appl Clin Med Phys"},{"issue":"1","key":"1054_CR17","doi-asserted-by":"publisher","first-page":"463","DOI":"10.1007\/s13246-020-00846-7","volume":"43","author":"PH Charles","year":"2020","unstructured":"Charles PH, Kairn T, Crowe SB (2020) Clinical quality assurance of 3D printed patient specific radiotherapy devices. Phys Eng Sci Med 43(1):436\u2013437. https:\/\/doi.org\/10.1007\/s13246-019-00826-6. Correction to: EPSM 2019, Engineering and Physical Sciences in Medicine. Phys Eng Sci Med 43(1):463. https:\/\/doi.org\/10.1007\/s13246-020-00846-7","journal-title":"Phys Eng Sci Med"},{"issue":"1","key":"1054_CR18","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1186\/s13014-018-1148-1","volume":"13","author":"G Dipasquale","year":"2018","unstructured":"Dipasquale G, Poirier A, Sprunger Y, Uiterwijk JWE, Miralbell R (2018) Improving 3D-printing of megavoltage X-rays radiotherapy bolus with surface-scanner. Radiat Oncol 13(1):203","journal-title":"Radiat Oncol"},{"key":"1054_CR19","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1007\/s13246-020-00861-8","volume":"43","author":"SK Maxwell","year":"2020","unstructured":"Maxwell SK, Charles PH, Cassim N, Kairn T, Crowe SB (2020) Assessing the fit of 3D printed bolus from CT, optical scanner and photogrammetry methods. Phys Eng Sci Med 43:601\u2013607","journal-title":"Phys Eng Sci Med"},{"issue":"4","key":"1054_CR20","doi-asserted-by":"publisher","first-page":"1614","DOI":"10.1002\/mp.12839","volume":"45","author":"DF Craft","year":"2018","unstructured":"Craft DF, Kry SF, Balter P, Salehpour M, Woodward W, Howell RM (2018) Material matters: analysis of density uncertainty in 3D printing and its consequences for radiation oncology. Med Phys 45(4):1614\u20131621","journal-title":"Med Phys"},{"issue":"1","key":"1054_CR21","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1002\/jmrs.378","volume":"67","author":"C Albantow","year":"2020","unstructured":"Albantow C, Hargrave C, Brown A, Halsall C (2020) Comparison of 3D printed nose bolus to traditional wax bolus for cost-effectiveness, volumetric accuracy and dosimetric effect. J Med Radiat Sci 67(1):54\u201363","journal-title":"J Med Radiat Sci"},{"key":"1054_CR22","first-page":"185","volume":"87","author":"SW Alderson","year":"1962","unstructured":"Alderson SW, Lanzl LH, Rollins M, Spira J (1962) An instrumented phantom system for analog computation of treatment plans. Am J Roentgenol Radium Ther Nucl Med 87:185\u2013195","journal-title":"Am J Roentgenol Radium Ther Nucl Med"},{"issue":"3","key":"1054_CR23","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/j.meddos.2017.10.003","volume":"43","author":"D Binny","year":"2018","unstructured":"Binny D, Kairn T, Lancaster CM, Trapp JV, Crowe SB (2018) Photon Optimizer (PO) versus Progressive Resolution Optimizer (PRO): a conformality and complexity based comparison for Intensity Modulated Arc Therapy plans. Med Dosim 43(3):267\u2013275","journal-title":"Med Dosim"},{"key":"1054_CR24","doi-asserted-by":"publisher","first-page":"21NT05","DOI":"10.1088\/1361-6560\/ab48ab","volume":"64","author":"R Tino","year":"2019","unstructured":"Tino R, Leary M, Yeo A, Brandt M, Kron T (2019) Gyroid structures for 3D-printed heterogeneous radiotherapy phantoms. Phys Med Biol 64:21NT05","journal-title":"Phys Med Biol"},{"key":"1054_CR25","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/j.ejmp.2017.05.051","volume":"38","author":"OL Dancewicz","year":"2017","unstructured":"Dancewicz OL, Sylvander SR, Markwell TS, Crowe SB, Trapp JV (2017) Radiological properties of 3D printed materials in kilovoltage and megavoltage photon beams. Phys Med 38:111\u2013118","journal-title":"Phys Med"},{"issue":"11","key":"1054_CR26","doi-asserted-by":"publisher","first-page":"R99","DOI":"10.1088\/0031-9155\/44\/11\/201","volume":"44","author":"A Ahnesjo","year":"1999","unstructured":"Ahnesjo A, Aspradakis MM (1999) Dose calculations for external photon beams in radiotherapy. Phys Med Biol 44(11):R99\u2013R155","journal-title":"Phys Med Biol"},{"issue":"5","key":"1054_CR27","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1016\/j.ejmp.2015.04.002","volume":"31","author":"L Dunn","year":"2015","unstructured":"Dunn L, Lehmann J, Lye J, Kenny J, Kron T, Alves A, Cole A, Zifodya J, Williams I (2015) National dosimetric audit network finds discrepancies in AAA lung inhomogeneity corrections. Phys Med 31(5):435\u2013441","journal-title":"Phys Med"},{"key":"1054_CR28","doi-asserted-by":"publisher","first-page":"1803","DOI":"10.1007\/978-3-642-29305-4_474","volume":"39","author":"SB Crowe","year":"2013","unstructured":"Crowe SB, Kairn T, Trapp JV, Fielding AL (2013) Monte Carlo evaluation of collapsed-cone convolution calculations in head and neck radiotherapy treatment plans. IFMBE Proc 39:1803\u20131806. https:\/\/doi.org\/10.1007\/978-3-642-29305-4_474","journal-title":"IFMBE Proc"},{"key":"1054_CR29","unstructured":"Cignoni P, Callieri M, Corsini M et al (2008) MeshLab: an open-source mesh processing tool. In: Sixth Eurographics Italian Chapter conference, pp 129\u2013136"},{"issue":"2","key":"1054_CR30","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1111\/1467-8659.00236","volume":"17","author":"P Cignoni","year":"1998","unstructured":"Cignoni P, Rocchini C, Scopigno R (1998) Metro: measuring error on simplified surfaces. Comput Graph Forum 17(2):167\u2013174","journal-title":"Comput Graph Forum"},{"issue":"2","key":"1054_CR31","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1007\/s13246-011-0072-6","volume":"34","author":"T Aland","year":"2011","unstructured":"Aland T, Kairn T, Kenny J (2011) Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance. Australas Phys Eng Sci Med 34(2):251\u2013260","journal-title":"Australas Phys Eng Sci Med"},{"issue":"1","key":"1054_CR32","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1007\/s13246-018-0620-4","volume":"41","author":"E Spelleken","year":"2018","unstructured":"Spelleken E, Crowe SB, Sutherland B, Challens C, Kairn T (2018) Accuracy and efficiency of published film dosimetry techniques using a flat-bed scanner and EBT3 film. Australas Phys Eng Sci Med 41(1):117\u2013128","journal-title":"Australas Phys Eng Sci Med"},{"key":"1054_CR33","doi-asserted-by":"publisher","DOI":"10.1201\/9781351188197","volume-title":"Diagnostic radiology physics with MATLAB: a problem-solving approach","author":"T Kairn","year":"2021","unstructured":"Kairn T (2021) Applying good software development processes in practice. In: Helmenkamp J, Bujila R, Poludniowski G (eds) Diagnostic radiology physics with MATLAB: a problem-solving approach. CRC Press, Boca Raton. https:\/\/doi.org\/10.1201\/9781351188197"},{"issue":"7","key":"1054_CR34","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1038\/nmeth.2089","volume":"9","author":"CA Schneider","year":"2012","unstructured":"Schneider CA, Rasband WS, Eliceiri KW (2012) NIH Image to ImageJ: 25 years of image analysis. Nat Methods 9(7):671\u2013675","journal-title":"Nat Methods"},{"issue":"4","key":"1054_CR35","doi-asserted-by":"publisher","first-page":"1208","DOI":"10.1148\/rg.2021200175","volume":"41","author":"S Bastawrous","year":"2021","unstructured":"Bastawrous S, Wu L, Strzelecki B, Levin DB, Li JS, Coburn J, Ripley B (2021) Establishing quality and safety in hospital-based 3D printing programs: patient-first approach. Radiographics 41(4):1208\u20131229","journal-title":"Radiographics"},{"key":"1054_CR36","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1186\/s41205-018-0030-y","volume":"4","author":"L Chepelev","year":"2018","unstructured":"Chepelev L, Wake N, Ryan J, Althobaity W, Gupta A, Arribas E, Santiago L, Ballard DH, Wang KC, Weadock W, Ionita CN (2018) Radiological Society of North America (RSNA) 3D Printing Special Interest Group (SIG): guidelines for medical 3D printing and appropriateness for clinical scenarios. 3D Print Med 4:11","journal-title":"3D Print Med"},{"key":"1054_CR37","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1186\/s41205-017-0014-3","volume":"3","author":"S Leng","year":"2017","unstructured":"Leng S, McGee K, Morris J, Alexander A, Kuhlmann J, Vrieze T, McCollough CH, Matsumoto J (2017) Anatomic modeling using 3D printing: quality assurance and optimization. 3D Print Med 3:6","journal-title":"3D Print Med"},{"issue":"11","key":"1054_CR38","doi-asserted-by":"publisher","first-page":"4130","DOI":"10.1118\/1.2358333","volume":"33","author":"A Van Esch","year":"2006","unstructured":"Van Esch A, Tillikainen L, Pyykkonen J, Tenhunen M, Helminen H, Siljam\u00e4ki S, Alakuijala J, Paiusco M, Iori M, Huyskens DP (2006) Testing of the analytical anisotropic algorithm for photon dose calculation. Med Phys 33(11):4130\u20134148","journal-title":"Med Phys"},{"issue":"3","key":"1054_CR39","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1088\/0031-9155\/55\/3\/002","volume":"55","author":"ON Vassiliev","year":"2010","unstructured":"Vassiliev ON, Wareing TA, McGhee J, Failla G, Salehpour MR, Mourtada F (2010) Validation of a new grid-based Boltzmann equation solver for dose calculation in radiotherapy with photon beams. Phys Med Biol 55(3):581\u2013598","journal-title":"Phys Med Biol"},{"issue":"1","key":"1054_CR40","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1186\/1748-717X-6-82","volume":"6","author":"A Fogliata","year":"2011","unstructured":"Fogliata A, Nicolini G, Clivio A, Vanetti E, Cozzi L (2011) Dosimetric evaluation of Acuros XB Advanced Dose Calculation algorithm in heterogeneous media. Radiat Oncol 6(1):82","journal-title":"Radiat Oncol"},{"key":"1054_CR41","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.ejmp.2020.09.019","volume":"78","author":"T Kairn","year":"2020","unstructured":"Kairn T, Livingstone AG, Crowe SB (2020) Monte Carlo calculations of radiotherapy dose in \u201chomogeneous\u201d anatomy. Phys Med 78:156\u2013165. https:\/\/doi.org\/10.1016\/j.ejmp.2020.09.019","journal-title":"Phys Med"},{"issue":"4","key":"1054_CR42","doi-asserted-by":"publisher","first-page":"1177","DOI":"10.1007\/s13246-016-0494-2","volume":"39","author":"P Ramachandran","year":"2016","unstructured":"Ramachandran P, Tajaldeen A, Roozen K, Wanigaratne D, Taylor D, Kron T (2016) A study of dose calculation algorithms using an IPSM phantom with different density materials for in-field and out-of-field conditions. Australas Phys Eng Sci Med 39(4):1177\u20131178. https:\/\/doi.org\/10.1007\/s13246-016-0494-2","journal-title":"Australas Phys Eng Sci Med"}],"container-title":["Physical and Engineering Sciences in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-021-01054-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s13246-021-01054-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-021-01054-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,8]],"date-time":"2023-11-08T22:00:37Z","timestamp":1699480837000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s13246-021-01054-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,16]]},"references-count":42,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["1054"],"URL":"https:\/\/doi.org\/10.1007\/s13246-021-01054-7","relation":{},"ISSN":["2662-4729","2662-4737"],"issn-type":[{"value":"2662-4729","type":"print"},{"value":"2662-4737","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,9,16]]},"assertion":[{"value":"27 April 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 August 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 September 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All authors declare that they have no conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}