{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T23:59:36Z","timestamp":1740182376603,"version":"3.37.3"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,1,4]],"date-time":"2022-01-04T00:00:00Z","timestamp":1641254400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2022,1,4]],"date-time":"2022-01-04T00:00:00Z","timestamp":1641254400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100020595","name":"Damascus University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100020595","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Phys Eng Sci Med"],"published-print":{"date-parts":[[2022,3]]},"DOI":"10.1007\/s13246-021-01096-x","type":"journal-article","created":{"date-parts":[[2022,1,4]],"date-time":"2022-01-04T11:04:44Z","timestamp":1641294284000},"page":"135-142","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Feasibility of 830\u00a0nm laser imaging for vein localization in dark skin tissue-mimicking phantoms"],"prefix":"10.1007","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3350-5091","authenticated-orcid":false,"given":"Wesam","family":"Bachir","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Farah","family":"Abo Dargham","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,1,4]]},"reference":[{"key":"1096_CR1","doi-asserted-by":"publisher","DOI":"10.3390\/s19163573","author":"CT Pan","year":"2019","unstructured":"Pan CT, Francisco MD, Yen CK et al (2019) Vein pattern locating technology for cannulation: A review of the low-cost vein finder prototypes utilizing near infrared (NIR) light to improve peripheral subcutaneous vein selection for phlebotomy. Sensors (Switzerland). https:\/\/doi.org\/10.3390\/s19163573","journal-title":"Sensors (Switzerland)"},{"key":"1096_CR2","volume-title":"Communications in Computer and Information Science","author":"D Prabhu","year":"2012","unstructured":"Prabhu D, Mohanavelu K, Sundersheshu BS, Padaki VC (2012) Vein identification and localization for automated intravenous drug delivery system. In: Venugopal KR, Patnaik LM (eds) Communications in Computer and Information Science. Springer, Berlin, Heidelberg"},{"key":"1096_CR3","doi-asserted-by":"publisher","DOI":"10.11613\/BM.2016.002","author":"C Ialongo","year":"2016","unstructured":"Ialongo C, Bernardini S (2016) Phlebotomy, a bridge between laboratory and patient. Biochem Medica. https:\/\/doi.org\/10.11613\/BM.2016.002","journal-title":"Biochem Medica"},{"key":"1096_CR4","doi-asserted-by":"publisher","DOI":"10.5617\/jeb.4560","author":"MB Al-Harosh","year":"2017","unstructured":"Al-Harosh MB, Shchukin SI (2017) Peripheral vein detection using electrical impedance method. J Electr Bioimpedance. https:\/\/doi.org\/10.5617\/jeb.4560","journal-title":"J Electr Bioimpedance"},{"key":"1096_CR5","doi-asserted-by":"publisher","DOI":"10.5811\/westjem.2017.7.34610","author":"M Gottlieb","year":"2017","unstructured":"Gottlieb M, Sundaram T, Holladay D, Nakitende D (2017) Ultrasound-guided peripheral intravenous line placement: a narrative review of evidence-based best practices. West J Emerg Med. https:\/\/doi.org\/10.5811\/westjem.2017.7.34610","journal-title":"West J Emerg Med"},{"key":"1096_CR6","doi-asserted-by":"publisher","DOI":"10.1007\/s00238-011-0583-0","author":"L Highton","year":"2011","unstructured":"Highton L, Ekwobi C (2011) Use of the AccuVein device to map the superficial venous system. Eur J Plast Surg. https:\/\/doi.org\/10.1007\/s00238-011-0583-0","journal-title":"Eur J Plast Surg"},{"key":"1096_CR7","doi-asserted-by":"publisher","DOI":"10.1177\/1043454215600425","author":"L Ramer","year":"2016","unstructured":"Ramer L, Hunt P, Ortega E et al (2016) Effect of intravenous (IV) assistive device (VeinViewer) on IV access attempts, procedural time, and patient and nurse satisfaction. J Pediatr Oncol Nurs. https:\/\/doi.org\/10.1177\/1043454215600425","journal-title":"J Pediatr Oncol Nurs"},{"key":"1096_CR8","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2012.06.007","author":"NJ Cuper","year":"2013","unstructured":"Cuper NJ, Klaessens JHG, Jaspers JEN et al (2013) The use of near-infrared light for safe and effective visualization of subsurface blood vessels to facilitate blood withdrawal in children. Med Eng Phys. https:\/\/doi.org\/10.1016\/j.medengphy.2012.06.007","journal-title":"Med Eng Phys"},{"key":"1096_CR9","doi-asserted-by":"publisher","DOI":"10.1016\/j.infrared.2020.103562","author":"K Efendiev","year":"2020","unstructured":"Efendiev K, Grachev P, Moskalev A, Loschenov V (2020) Non-invasive high-contrast infrared imaging of blood vessels in biological tissues by the backscattered laser radiation method. Infrared Phys Technol. https:\/\/doi.org\/10.1016\/j.infrared.2020.103562","journal-title":"Infrared Phys Technol"},{"key":"1096_CR10","doi-asserted-by":"publisher","DOI":"10.1364\/boe.7.002565","author":"D Ai","year":"2016","unstructured":"Ai D, Yang J, Fan J et al (2016) Augmented reality based real-time subcutaneous vein imaging system. Biomed Opt Express. https:\/\/doi.org\/10.1364\/boe.7.002565","journal-title":"Biomed Opt Express"},{"key":"1096_CR11","doi-asserted-by":"publisher","DOI":"10.1364\/oe.17.011360","author":"VC Paquit","year":"2009","unstructured":"Paquit VC, Tobin KW, Price JR, M\u00e8riaudeau F (2009) 3D and multispectral imaging for subcutaneous veins detection. Opt Express. https:\/\/doi.org\/10.1364\/oe.17.011360","journal-title":"Opt Express"},{"key":"1096_CR12","doi-asserted-by":"publisher","DOI":"10.1117\/1.jbo.18.5.050504","author":"F Wang","year":"2013","unstructured":"Wang F, Behrooz A, Morris M, Adibi A (2013) High-contrast subcutaneous vein detection and localization using multispectral imaging. J Biomed Opt. https:\/\/doi.org\/10.1117\/1.jbo.18.5.050504","journal-title":"J Biomed Opt"},{"key":"1096_CR13","doi-asserted-by":"publisher","DOI":"10.1016\/j.det.2009.08.006","author":"WE Roberts","year":"2009","unstructured":"Roberts WE (2009) Skin type classification systems old and new. Dermatol Clin. https:\/\/doi.org\/10.1016\/j.det.2009.08.006","journal-title":"Dermatol Clin"},{"key":"1096_CR14","doi-asserted-by":"publisher","DOI":"10.3390\/app10228238","author":"RN Jadoon","year":"2020","unstructured":"Jadoon RN, Shahzad A, Shah SAA et al (2020) Veins depth estimation using diffused reflectance parameter. Appl Sci. https:\/\/doi.org\/10.3390\/app10228238","journal-title":"Appl Sci"},{"key":"1096_CR15","doi-asserted-by":"publisher","DOI":"10.1117\/1.2829772","author":"S-H Tseng","year":"2008","unstructured":"Tseng S-H, Grant A, Durkin AJ (2008) In vivo determination of skin near-infrared optical properties using diffuse optical spectroscopy. J Biomed Opt. https:\/\/doi.org\/10.1117\/1.2829772","journal-title":"J Biomed Opt"},{"key":"1096_CR16","doi-asserted-by":"publisher","DOI":"10.1111\/1523-1747.ep12479191","author":"RR Anderson","year":"1981","unstructured":"Anderson RR, Parrish JA (1981) The optics of human skin. J Invest Dermatol. https:\/\/doi.org\/10.1111\/1523-1747.ep12479191","journal-title":"J Invest Dermatol"},{"key":"1096_CR17","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/58\/11\/R37","author":"SL Jacques","year":"2013","unstructured":"Jacques SL (2013) Optical properties of biological tissues: a review. Phys Med Biol. https:\/\/doi.org\/10.1088\/0031-9155\/58\/11\/R37","journal-title":"Phys Med Biol"},{"key":"1096_CR18","doi-asserted-by":"publisher","DOI":"10.1001\/archderm.1988.01670060015008","author":"TB Fitzpatrick","year":"1988","unstructured":"Fitzpatrick TB (1988) The validity and practicality of sun-reactive skin types I through VI. Arch Dermatol. https:\/\/doi.org\/10.1001\/archderm.1988.01670060015008","journal-title":"Arch Dermatol"},{"key":"1096_CR19","doi-asserted-by":"publisher","DOI":"10.1117\/1.jbo.26.2.026001","author":"T Phan","year":"2021","unstructured":"Phan T, Rowland R, Ponticorvo A et al (2021) Characterizing reduced scattering coefficient of normal human skin across different anatomic locations and Fitzpatrick skin types using spatial frequency domain imaging. J Biomed Opt. https:\/\/doi.org\/10.1117\/1.jbo.26.2.026001","journal-title":"J Biomed Opt"},{"key":"1096_CR20","doi-asserted-by":"publisher","DOI":"10.1002\/jbio.201300198","author":"TM Bydlon","year":"2015","unstructured":"Bydlon TM, Nachab\u00e9 R, Ramanujam N et al (2015) Chromophore based analyses of steady-state diffuse reflectance spectroscopy: Current status and perspectives for clinical adoption. J Biophotonics. https:\/\/doi.org\/10.1002\/jbio.201300198","journal-title":"J Biophotonics"},{"key":"1096_CR21","doi-asserted-by":"publisher","DOI":"10.1364\/oe.18.026854","author":"P Di Ninni","year":"2010","unstructured":"Di Ninni P, Martelli F, Zaccanti G (2010) The use of India ink in tissue-simulating phantoms. Opt Express. https:\/\/doi.org\/10.1364\/oe.18.026854","journal-title":"Opt Express"},{"key":"1096_CR22","doi-asserted-by":"publisher","DOI":"10.1051\/epjap\/2020200234","author":"A Shahin","year":"2021","unstructured":"Shahin A, Bachir W, El-Daher MS (2021) Optical properties in the visible range of two different India ink used as biological phantoms. EPJ Appl Phys. https:\/\/doi.org\/10.1051\/epjap\/2020200234","journal-title":"EPJ Appl Phys"},{"key":"1096_CR23","doi-asserted-by":"publisher","DOI":"10.1007\/BF02763978","author":"LT Norvang","year":"1997","unstructured":"Norvang LT, Milner TE, Nelson JS et al (1997) Skin pigmentation characterized by visible reflectance measurements. Lasers Med Sci. https:\/\/doi.org\/10.1007\/BF02763978","journal-title":"Lasers Med Sci"},{"key":"1096_CR24","doi-asserted-by":"publisher","DOI":"10.3168\/jds.2015-9630","author":"B Aernouts","year":"2015","unstructured":"Aernouts B, Van Beers R, Watt\u00e9 R et al (2015) Visible and near-infrared bulk optical properties of raw milk. J Dairy Sci. https:\/\/doi.org\/10.3168\/jds.2015-9630","journal-title":"J Dairy Sci"},{"key":"1096_CR25","doi-asserted-by":"publisher","DOI":"10.1016\/j.heliyon.2020.e03602","author":"L Ntombela","year":"2020","unstructured":"Ntombela L, Adeleye B, Chetty N (2020) Low-cost fabrication of optical tissue phantoms for use in biomedical imaging. Heliyon. https:\/\/doi.org\/10.1016\/j.heliyon.2020.e03602","journal-title":"Heliyon"},{"key":"1096_CR26","doi-asserted-by":"publisher","DOI":"10.1201\/9780203024058","volume-title":"Biosignal and Medical Image Processing","author":"JL Semmlow","year":"2008","unstructured":"Semmlow JL (2008) Biosignal and Medical Image Processing. CRC Press, Boca Raton"},{"key":"1096_CR27","doi-asserted-by":"publisher","DOI":"10.1364\/boe.3.002154","author":"GI Petrov","year":"2012","unstructured":"Petrov GI, Doronin A, Whelan HT et al (2012) Human tissue color as viewed in high dynamic range optical spectral transmission measurements. Biomed Opt Express. https:\/\/doi.org\/10.1364\/boe.3.002154","journal-title":"Biomed Opt Express"},{"key":"1096_CR28","doi-asserted-by":"publisher","DOI":"10.1016\/j.rinp.2018.10.033","author":"A Madrid Garc\u00eda","year":"2018","unstructured":"Madrid Garc\u00eda A, Horche PR (2018) Light source optimizing in a biphotonic vein finder device: Experimental and theoretical analysis. Results Phys. https:\/\/doi.org\/10.1016\/j.rinp.2018.10.033","journal-title":"Results Phys"},{"key":"1096_CR29","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdcr.2018.11.022","author":"F AlZahrani","year":"2019","unstructured":"AlZahrani F, Crosby M, Fiorillo L (2019) Use of AccuVein AV400 for identification of probable RICH. JAAD Case Rep. https:\/\/doi.org\/10.1016\/j.jdcr.2018.11.022","journal-title":"JAAD Case Rep"}],"container-title":["Physical and Engineering Sciences in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-021-01096-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s13246-021-01096-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-021-01096-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,7]],"date-time":"2022-03-07T15:34:55Z","timestamp":1646667295000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s13246-021-01096-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,4]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,3]]}},"alternative-id":["1096"],"URL":"https:\/\/doi.org\/10.1007\/s13246-021-01096-x","relation":{},"ISSN":["2662-4729","2662-4737"],"issn-type":[{"type":"print","value":"2662-4729"},{"type":"electronic","value":"2662-4737"}],"subject":[],"published":{"date-parts":[[2022,1,4]]},"assertion":[{"value":"19 August 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 December 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 January 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All the subjects provided written informed consent to participate have their data utilized for this study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"Patients signed informed consent regarding publishing their data.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}]}}