{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,14]],"date-time":"2026-03-14T20:14:09Z","timestamp":1773519249517,"version":"3.50.1"},"reference-count":51,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T00:00:00Z","timestamp":1693180800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T00:00:00Z","timestamp":1693180800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Phys Eng Sci Med"],"published-print":{"date-parts":[[2023,12]]},"DOI":"10.1007\/s13246-023-01320-w","type":"journal-article","created":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T09:04:32Z","timestamp":1693213472000},"page":"1563-1572","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Shortening image registration time using a deep neural network for patient positional verification in radiotherapy"],"prefix":"10.1007","volume":"46","author":[{"given":"Shinichiro","family":"Mori","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryusuke","family":"Hirai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yukinobu","family":"Sakata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masashi","family":"Koto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hitoshi","family":"Ishikawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,8,28]]},"reference":[{"key":"1320_CR1","volume-title":"World Cancer Report Cancer 2020","author":"C Wild","year":"2020","unstructured":"Wild C, Weiderpass E, Stewart B (2020) World Cancer Report Cancer 2020. IARC Press, Imprimerie Faurite, France"},{"key":"1320_CR2","doi-asserted-by":"publisher","first-page":"1129","DOI":"10.1002\/cncr.21324","volume":"104","author":"G Delaney","year":"2005","unstructured":"Delaney G, Jacob S, Featherstone C, Barton M (2005) The role of radiotherapy in cancer treatment: estimating optimal utilization from a review of evidence-based clinical guidelines. Cancer 104:1129\u20131137","journal-title":"Cancer"},{"key":"1320_CR3","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1016\/j.clon.2016.11.011","volume":"29","author":"E Zubizarreta","year":"2017","unstructured":"Zubizarreta E, Van Dyk J, Lievens Y (2017) Analysis of global Radiotherapy needs and costs by Geographic Region and Income Level. Clin Oncol (R Coll Radiol) 29:84\u201392","journal-title":"Clin Oncol (R Coll Radiol)"},{"key":"1320_CR4","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.radonc.2012.11.011","volume":"106","author":"L Perrier","year":"2013","unstructured":"Perrier L, Morelle M, Pommier P, Lagrange JL, Laplanche A, Dudouet P et al (2013) Cost of prostate image-guided radiation therapy: results of a randomized trial. Radiother Oncol 106:50\u201358","journal-title":"Radiother Oncol"},{"key":"1320_CR5","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/j.radonc.2009.12.002","volume":"95","author":"A Peeters","year":"2010","unstructured":"Peeters A, Grutters JP, Pijls-Johannesma M, Reimoser S, De Ruysscher D, Severens JL et al (2010) How costly is particle therapy? Cost analysis of external beam radiotherapy with carbon-ions, protons and photons. Radiother Oncol 95:45\u201353","journal-title":"Radiother Oncol"},{"key":"1320_CR6","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/j.radonc.2011.12.026","volume":"103","author":"Y Lievens","year":"2012","unstructured":"Lievens Y, Grau C (2012) Health economics in radiation oncology: introducing the ESTRO HERO project. Radiother Oncol 103:109\u2013112","journal-title":"Radiother Oncol"},{"key":"1320_CR7","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1016\/j.ijrobp.2014.01.039","volume":"89","author":"B Vanderstraeten","year":"2014","unstructured":"Vanderstraeten B, Verstraete J, De Croock R, De Neve W, Lievens Y (2014) In search of the economic sustainability of Hadron therapy: the real cost of setting up and operating a Hadron facility. Int J Radiat Oncol Biol Phys 89:152\u2013160","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1320_CR8","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1016\/j.ejmp.2018.06.002","volume":"52","author":"S Mori","year":"2018","unstructured":"Mori S, Takei Y, Shirai T, Hara Y, Furukawa T, Inaniwa T et al (2018) Scanned carbon-ion beam therapy throughput over the first 7 years at National Institute of Radiological Sciences. Phys Med 52:18\u201326","journal-title":"Phys Med"},{"key":"1320_CR9","doi-asserted-by":"publisher","first-page":"818","DOI":"10.1093\/jrr\/rrv032","volume":"56","author":"S Mori","year":"2015","unstructured":"Mori S, Kumagai M, Miki K, Fukuhara R, Haneishi H (2015) Development of fast patient position verification software using 2D-3D image registration and its clinical experience. J Radiat Res 56:818\u2013829","journal-title":"J Radiat Res"},{"key":"1320_CR10","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1016\/j.radonc.2009.12.036","volume":"95","author":"Z Chang","year":"2010","unstructured":"Chang Z, Wang Z, Ma J, O\u2019Daniel JC, Kirkpatrick J, Yin FF (2010) 6D image guidance for spinal non-invasive stereotactic body radiation therapy: comparison between ExacTrac X-ray 6D with kilo-voltage cone-beam CT. Radiother Oncol 95:116\u2013121","journal-title":"Radiother Oncol"},{"key":"1320_CR11","doi-asserted-by":"publisher","first-page":"586","DOI":"10.1109\/42.730403","volume":"17","author":"GP Penney","year":"1998","unstructured":"Penney GP, Weese J, Little JA, Desmedt P, Hill DL, Hawkes DJ (1998) A comparison of similarity measures for use in 2-D-3-D medical image registration. IEEE Trans Med Imaging 17:586\u2013595","journal-title":"IEEE Trans Med Imaging"},{"key":"1320_CR12","doi-asserted-by":"publisher","first-page":"2870","DOI":"10.1118\/1.1997367","volume":"32","author":"T Rohlfing","year":"2005","unstructured":"Rohlfing T, Russakoff DB, Denzler J, Mori K, Maurer CR Jr (2005) Progressive attenuation fields: fast 2D-3D image registration without precomputation. Med Phys 32:2870\u20132880","journal-title":"Med Phys"},{"key":"1320_CR13","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.ejmp.2022.05.008","volume":"99","author":"L Vandewinckele","year":"2022","unstructured":"Vandewinckele L, Willems S, Lambrecht M, Berkovic P, Maes F, Crijns W (2022) Treatment plan prediction for lung IMRT using deep learning based fluence map generation. Phys Med 99:44\u201354","journal-title":"Phys Med"},{"key":"1320_CR14","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.ejmp.2022.01.006","volume":"95","author":"B Yang","year":"2022","unstructured":"Yang B, Chen X, Li J, Zhu J, Men K, Dai J (2022) A feasible method to evaluate deformable image registration with deep learning-based segmentation. Phys Med 95:50\u201356","journal-title":"Phys Med"},{"key":"1320_CR15","doi-asserted-by":"publisher","first-page":"1408","DOI":"10.1002\/mp.12155","volume":"44","author":"H Xiao","year":"2017","unstructured":"Xiao H (2017) MR-based synthetic CT generation using a deep convolutional neural network method. Med Phys 44:1408\u20131419","journal-title":"Med Phys"},{"key":"1320_CR16","doi-asserted-by":"publisher","first-page":"3627","DOI":"10.1002\/mp.13047","volume":"45","author":"H Emami","year":"2018","unstructured":"Emami H, Dong M, Nejad-Davarani SP, Glide-Hurst CK (2018) Generating synthetic CTs from magnetic resonance images using generative adversarial networks. Med Phys 45:3627\u20133636","journal-title":"Med Phys"},{"key":"1320_CR17","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1016\/j.radonc.2019.09.028","volume":"141","author":"X Dong","year":"2019","unstructured":"Dong X, Lei Y, Tian S, Wang T, Patel P, Curran WJ et al (2019) Synthetic MRI-aided multi-organ segmentation on male pelvic CT using cycle consistent deep attention network. Radiother Oncol 141:192\u2013199","journal-title":"Radiother Oncol"},{"key":"1320_CR18","doi-asserted-by":"publisher","first-page":"4392","DOI":"10.1002\/mp.13695","volume":"46","author":"J Jiang","year":"2019","unstructured":"Jiang J, Hu YC, Tyagi N, Zhang P, Rimner A, Deasy JO et al (2019) Cross-modality (CT-MRI) prior augmented deep learning for robust lung tumor segmentation from small MR datasets. Med Phys 46:4392\u20134404","journal-title":"Med Phys"},{"key":"1320_CR19","doi-asserted-by":"publisher","first-page":"4916","DOI":"10.1002\/mp.13175","volume":"45","author":"DC Hansen","year":"2018","unstructured":"Hansen DC, Landry G, Kamp F, Li M, Belka C, Parodi K et al (2018) ScatterNet: a convolutional neural network for cone-beam CT intensity correction. Med Phys 45:4916\u20134926","journal-title":"Med Phys"},{"key":"1320_CR20","doi-asserted-by":"publisher","first-page":"1115","DOI":"10.1002\/mp.13978","volume":"47","author":"L Chen","year":"2020","unstructured":"Chen L, Liang X, Shen C, Jiang S, Wang J (2020) Synthetic CT generation from CBCT images via deep learning. Med Phys 47:1115\u20131125","journal-title":"Med Phys"},{"key":"1320_CR21","doi-asserted-by":"publisher","first-page":"1624","DOI":"10.2967\/jnumed.117.202317","volume":"59","author":"D Hwang","year":"2018","unstructured":"Hwang D, Kim KY, Kang SK, Seo S, Paeng JC, Lee DS et al (2018) Improving the Accuracy of simultaneously reconstructed activity and attenuation maps using deep learning. J Nucl Med 59:1624\u20131629","journal-title":"J Nucl Med"},{"key":"1320_CR22","doi-asserted-by":"publisher","first-page":"1418","DOI":"10.1109\/TMI.2018.2823768","volume":"37","author":"Y Han","year":"2018","unstructured":"Han Y, Ye JC (2018) Framing U-Net via Deep Convolutional Framelets: application to sparse-view CT. IEEE Trans Med Imaging 37:1418\u20131429","journal-title":"IEEE Trans Med Imaging"},{"key":"1320_CR23","doi-asserted-by":"publisher","first-page":"4509","DOI":"10.1109\/TIP.2017.2713099","volume":"26","author":"J Kyong Hwan","year":"2017","unstructured":"Kyong Hwan J, McCann MT, Froustey E, Unser M (2017) Deep convolutional neural network for inverse problems in imaging. IEEE Trans Image Process 26:4509\u20134522","journal-title":"IEEE Trans Image Process"},{"key":"1320_CR24","doi-asserted-by":"publisher","first-page":"3926","DOI":"10.1120\/jacmp.v13i6.3926","volume":"13","author":"S Mori","year":"2012","unstructured":"Mori S, Shirai T, Takei Y, Furukawa T, Inaniwa T, Matsuzaki Y et al (2012) Patient handling system for carbon ion beam scanning therapy. J Appl Clin Med Phys 13:3926","journal-title":"J Appl Clin Med Phys"},{"key":"1320_CR25","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1120\/jacmp.v13i6.3926","volume":"13","author":"S Mori","year":"2012","unstructured":"Mori S, Shirai T, Takei Y, Furukawa T, Inaniwa T, Matsuzaki Y et al (2012) Patient handling system for carbon ion beam scanning therapy. J Appl Clin Med Phys 13:226\u2013240","journal-title":"J Appl Clin Med Phys"},{"key":"1320_CR26","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1007\/s13246-012-0142-4","volume":"35","author":"S Mori","year":"2012","unstructured":"Mori S, Inaniwa T, Kumagai M, Kuwae T, Matsuzaki Y, Furukawa T et al (2012) Development of digital reconstructed radiography software at new treatment facility for carbon-ion beam scanning of National Institute of Radiological Sciences. Australas Phys Eng Sci Med 35:221\u2013229","journal-title":"Australas Phys Eng Sci Med"},{"key":"1320_CR27","doi-asserted-by":"crossref","unstructured":"Vasiliadis G, Antonatos S, Polychronakis M, Markatos E, Ioannidis S (2008) Gnort: High Performance Network Intrusion Detection Using Graphics Processors. Proceedings of the 11th International Symposium on Recent Advances in Intrusion Detection (RAID). pp 116\u2013134","DOI":"10.1007\/978-3-540-87403-4_7"},{"key":"1320_CR28","doi-asserted-by":"publisher","first-page":"2481","DOI":"10.1109\/TPAMI.2016.2644615","volume":"39","author":"V Badrinarayanan","year":"2017","unstructured":"Badrinarayanan V, Kendall A, Cipolla R, SegNet: (2017) A deep Convolutional Encoder-Decoder Architecture for Image Segmentation. IEEE Trans Pattern Anal Mach Intell 39:2481\u20132495","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"1320_CR29","first-page":"1929","volume":"15","author":"N Srivastava","year":"2014","unstructured":"Srivastava N, Hinton G, Krizhevsky A, Sutskever I, Salakhutdinov N, Dropout (2014) A simple way to prevent neural networks from overfitting. J Mach Learn Res 15:1929\u20131958","journal-title":"J Mach Learn Res"},{"key":"1320_CR30","unstructured":"Sergey I, Christian S (2015) Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift. The 32nd International Conference on Machine Learning. pp 448\u2013456"},{"key":"1320_CR31","first-page":"234","volume-title":"Medical Image Computing and Computer-Assisted intervention (MICCAI)","author":"O Ronneberger","year":"2015","unstructured":"Ronneberger O, Fischer P, Brox T (2015) U-Net: Convolutional Networks for Biomedical Image Segmentation. Medical Image Computing and Computer-Assisted intervention (MICCAI). Springer, Munich, Germany, pp 234\u2013241"},{"key":"1320_CR32","unstructured":"Radford A, Metz L, Chintala S (2015) Unsupervised Representation Learning with Deep Convolutional Generative Adversarial Networks. arXiv:150806576."},{"key":"1320_CR33","unstructured":"Kingma D, Ba J, Adam A Method for Stochastic Optimization. In Proceedings of the 3rd International Conference on Learning Representations (ICLR)2015"},{"key":"1320_CR34","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1109\/TIP.2003.819861","volume":"13","author":"Z Wang","year":"2004","unstructured":"Wang Z, Bovik AC, Sheikh HR, Simoncelli EP (2004) Image quality assessment: from error visibility to structural similarity. IEEE Trans Image Process 13:600\u2013612","journal-title":"IEEE Trans Image Process"},{"key":"1320_CR35","doi-asserted-by":"crossref","unstructured":"Wang Z, Simoncelli EP, Bovik AC (2003) Multiscale structural similarity for image quality assessment. The Thirty-Seventh Asilomar Conference on Signals, Systems & Computers, 2003. Pacific Grove, CA, USA. pp 1398\u20131402","DOI":"10.1109\/ACSSC.2003.1292216"},{"key":"1320_CR36","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/S0031-3203(98)00091-0","volume":"32","author":"C Studholme","year":"1999","unstructured":"Studholme C, Hill DL, Hawkes DJ (1999) An overlap invariant entropy measure of 3D medical image alignment. Pattern Recogn 32:71\u201386","journal-title":"Pattern Recogn"},{"key":"1320_CR37","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1097\/00004728-199509000-00001","volume":"19","author":"JV Hajnal","year":"1995","unstructured":"Hajnal JV, Saeed N, Oatridge A, Williams EJ, Young IR, Bydder GM (1995) Detection of subtle brain changes using Subvoxel Registration and Subtraction of serial Mr-Images. J Comput Assist Tomo 19:677\u2013691","journal-title":"J Comput Assist Tomo"},{"key":"1320_CR38","unstructured":"Teukolsky SA, Vetterling WT, Flannery BP (1992) Numerical Recipes in C: The Art of Scientific Computing, Second Edition."},{"key":"1320_CR39","doi-asserted-by":"publisher","first-page":"2180","DOI":"10.1118\/1.2903431","volume":"35","author":"D Fu","year":"2008","unstructured":"Fu D, Kuduvalli G (2008) A fast, accurate, and automatic 2D-3D image registration for image-guided cranial radiosurgery. Med Phys 35:2180\u20132194","journal-title":"Med Phys"},{"key":"1320_CR40","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/j.ejmp.2020.05.007","volume":"74","author":"F di Franco","year":"2020","unstructured":"di Franco F, Sarno A, Mettivier G, Hernandez AM, Bliznakova K, Boone JM et al (2020) GEANT4 Monte Carlo simulations for virtual clinical trials in breast X-ray imaging: Proof of concept. Phys Med 74:133\u2013142","journal-title":"Phys Med"},{"key":"1320_CR41","doi-asserted-by":"publisher","first-page":"1044","DOI":"10.1016\/j.cpc.2013.10.034","volume":"185","author":"B Golosio","year":"2014","unstructured":"Golosio B, Schoonjans T, Brunetti A, Oliva P, Masala GL (2014) Monte Carlo simulation of X-ray imaging and spectroscopy experiments using quadric geometry and variance reduction techniques. Comput Phys Commun 185:1044\u20131052","journal-title":"Comput Phys Commun"},{"key":"1320_CR42","doi-asserted-by":"publisher","first-page":"20190067","DOI":"10.1259\/bjr.20190067","volume":"92","author":"Y Liu","year":"2019","unstructured":"Liu Y, Lei Y, Wang T, Kayode O, Tian S, Liu T et al (2019) MRI-based treatment planning for liver stereotactic body radiotherapy: validation of a deep learning-based synthetic CT generation method. Br J Radiol 92:20190067","journal-title":"Br J Radiol"},{"key":"1320_CR43","doi-asserted-by":"publisher","first-page":"2746","DOI":"10.1007\/s00259-019-04380-x","volume":"46","author":"H Arabi","year":"2019","unstructured":"Arabi H, Zeng G, Zheng G, Zaidi H (2019) Novel adversarial semantic structure deep learning for MRI-guided attenuation correction in brain PET\/MRI. Eur J Nucl Med Mol Imaging 46:2746\u20132759","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"1320_CR44","doi-asserted-by":"publisher","first-page":"530","DOI":"10.1002\/mp.13933","volume":"47","author":"Y Lei","year":"2020","unstructured":"Lei Y, Dong X, Tian Z, Liu Y, Tian S, Wang T et al (2020) CT prostate segmentation based on synthetic MRI-aided deep attention fully convolution network. Med Phys 47:530\u2013540","journal-title":"Med Phys"},{"key":"1320_CR45","doi-asserted-by":"publisher","first-page":"1337","DOI":"10.1016\/S0360-3016(02)02884-5","volume":"53","author":"DA Jaffray","year":"2002","unstructured":"Jaffray DA, Siewerdsen JH, Wong JW, Martinez AA (2002) Flat-panel cone-beam computed tomography for image-guided radiation therapy. Int J Radiat Oncol Biol Phys 53:1337\u20131349","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1320_CR46","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1016\/j.ijom.2004.09.010","volume":"34","author":"M Heiland","year":"2005","unstructured":"Heiland M, Schulze D, Blake F, Schmelzle R (2005) Intraoperative imaging of zygomaticomaxillary complex fractures using a 3D C-arm system. Int J Oral Maxillofac Surg 34:369\u2013375","journal-title":"Int J Oral Maxillofac Surg"},{"key":"1320_CR47","doi-asserted-by":"publisher","first-page":"811","DOI":"10.1016\/S0360-3016(02)04207-4","volume":"55","author":"C Hua","year":"2003","unstructured":"Hua C, Lovelock DM, Mageras GS, Katz MS, Mechalakos J, Lief EP et al (2003) Development of a semi-automatic alignment tool for accelerated localization of the prostate. Int J Radiation Oncol Biol Phys 55:811\u2013824","journal-title":"Int J Radiation Oncology*Biology*Physics"},{"key":"1320_CR48","doi-asserted-by":"publisher","first-page":"1265","DOI":"10.1016\/j.ijrobp.2005.11.008","volume":"64","author":"C Bert","year":"2006","unstructured":"Bert C, Metheany KG, Doppke KP, Taghian AG, Powell SN, Chen GT (2006) Clinical experience with a 3D surface patient setup system for alignment of partial-breast irradiation patients. Int J Radiat Oncol Biol Phys 64:1265\u20131274","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1320_CR49","doi-asserted-by":"crossref","unstructured":"Sun B, Feng J, Saenko K (2015) Return of Frustratingly Easy Domain Adaptation. p. arXiv:1511.05547","DOI":"10.1609\/aaai.v30i1.10306"},{"key":"1320_CR50","doi-asserted-by":"publisher","first-page":"1173","DOI":"10.1109\/TBME.2021.3117407","volume":"69","author":"H Guan","year":"2022","unstructured":"Guan H, Liu M (2022) Domain adaptation for medical image analysis: a Survey. IEEE Trans Biomed Eng 69:1173\u20131185","journal-title":"IEEE Trans Biomed Eng"},{"key":"1320_CR51","doi-asserted-by":"publisher","first-page":"e0273262","DOI":"10.1371\/journal.pone.0273262","volume":"17","author":"AA Valliani","year":"2022","unstructured":"Valliani AA, Gulamali FF, Kwon YJ, Martini ML, Wang C, Kondziolka D et al (2022) Deploying deep learning models on unseen medical imaging using adversarial domain adaptation. PLoS ONE 17:e0273262","journal-title":"PLoS ONE"}],"container-title":["Physical and Engineering Sciences in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-023-01320-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s13246-023-01320-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-023-01320-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,7]],"date-time":"2023-12-07T10:32:00Z","timestamp":1701945120000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s13246-023-01320-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,28]]},"references-count":51,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2023,12]]}},"alternative-id":["1320"],"URL":"https:\/\/doi.org\/10.1007\/s13246-023-01320-w","relation":{},"ISSN":["2662-4729","2662-4737"],"issn-type":[{"value":"2662-4729","type":"print"},{"value":"2662-4737","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,28]]},"assertion":[{"value":"2 September 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 August 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 August 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Drs. Hirai and Sakata are employed by the Toshiba Corporation, Kawasaki, Japan.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"The study was approved by the Institutional Review Board of our institution (N21-001).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"All patients were informed of the contents of the study and gave consent to participate.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}