{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T23:59:55Z","timestamp":1740182395423,"version":"3.37.3"},"reference-count":46,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2023,10,23]],"date-time":"2023-10-23T00:00:00Z","timestamp":1698019200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,10,23]],"date-time":"2023-10-23T00:00:00Z","timestamp":1698019200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Phys Eng Sci Med"],"published-print":{"date-parts":[[2023,12]]},"DOI":"10.1007\/s13246-023-01335-3","type":"journal-article","created":{"date-parts":[[2023,10,23]],"date-time":"2023-10-23T10:01:42Z","timestamp":1698055302000},"page":"1755-1764","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Biomechanical evaluation of intramedullary retrograde nail and dynamic condylar screw used in unstable distal femoral fractures"],"prefix":"10.1007","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7835-0831","authenticated-orcid":false,"given":"Ayberk","family":"Dizdar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0033-2454","authenticated-orcid":false,"given":"Talip","family":"Celik","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1288-6166","authenticated-orcid":false,"given":"Arif","family":"Ozkan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,10,23]]},"reference":[{"issue":"4","key":"1335_CR1","doi-asserted-by":"publisher","first-page":"967","DOI":"10.1016\/j.injury.2020.11.061","volume":"52","author":"JA Richards","year":"2021","unstructured":"Richards JA, Berkay FB, Davis CM, Zamora RA (2021) Intra-articular fracture pattern in intercondylar distal femur fractures: an analysis of frequency and major fracture fragments. Injury 52(4):967\u2013970. https:\/\/doi.org\/10.1016\/j.injury.2020.11.061","journal-title":"Injury"},{"issue":"7","key":"1335_CR2","doi-asserted-by":"publisher","first-page":"1170","DOI":"10.1016\/j.injury.2012.03.023","volume":"43","author":"C Garnavos","year":"2012","unstructured":"Garnavos C, Lygdas P, Lasanianos NG (2012) Retrograde nailing and compression bolts in the treatment of type C distal femoral fractures. Injury 43(7):1170\u20131175. https:\/\/doi.org\/10.1016\/j.injury.2012.03.023","journal-title":"Injury"},{"issue":"2","key":"1335_CR3","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/j.injury.2005.02.015","volume":"37","author":"MC Forster","year":"2006","unstructured":"Forster MC, Komarsamy B, Davison JN (2006) Distal femoral fractures: a review of fixation methods. Injury 37(2):97\u2013108. https:\/\/doi.org\/10.1016\/j.injury.2005.02.015","journal-title":"Injury"},{"issue":"1","key":"1335_CR4","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1007\/s00264-006-0137-4","volume":"31","author":"S El-Kawy","year":"2006","unstructured":"El-Kawy S, Ansara S, Moftah A, Shalaby H, Varughese V (2006) Retrograde femoral nailing in elderly patients with supracondylar fracture femur; is it the answer for a clinical problem? Int Orthop 31(1):83. https:\/\/doi.org\/10.1007\/s00264-006-0137-4","journal-title":"Int Orthop"},{"issue":"1115\/1","key":"1335_CR5","first-page":"4051186","volume":"10","author":"T \u00c7elik","year":"2021","unstructured":"\u00c7elik T (2021) Evaluation of the relation between preload values and pull-out force of the cortical screw used in bone fracture. J Biomech Eng 10(1115\/1):4051186","journal-title":"J Biomech Eng"},{"key":"1335_CR6","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/j.bonr.2017.03.002","volume":"6","author":"MS Ghiasi","year":"2017","unstructured":"Ghiasi MS, Chen J, Vaziri A, Rodriguez EK, Nazarian A (2017) Bone fracture healing in mechanobiological modeling: a review of principles and methods. Bone reports 6:87\u2013100. https:\/\/doi.org\/10.1016\/j.bonr.2017.03.002","journal-title":"Bone reports"},{"issue":"1","key":"1335_CR7","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/j.knee.2013.03.006","volume":"21","author":"S-H Chen","year":"2014","unstructured":"Chen S-H, Chiang M-C, Hung C-H, Lin S-C, Chang H-W (2014) Finite element comparison of retrograde intramedullary nailing and locking plate fixation with\/without an intramedullary allograft for distal femur fracture following total knee arthroplasty. Knee 21(1):224\u2013231. https:\/\/doi.org\/10.1016\/j.knee.2013.03.006","journal-title":"Knee"},{"issue":"3","key":"1335_CR8","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1097\/00005131-198909000-00006","volume":"3","author":"R Sanders","year":"1989","unstructured":"Sanders R, Regazzoni P, Ruedi TP (1989) Treatment of supracondylar-intracondylar fractures of the femur using the dynamic condylar screw. J Orthop Trauma 3(3):214\u2013222. https:\/\/doi.org\/10.1097\/00005131-198909000-00006","journal-title":"J Orthop Trauma"},{"issue":"7","key":"1335_CR9","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1097\/00005131-200308000-00003","volume":"17","author":"J Seifert","year":"2003","unstructured":"Seifert J, Stengel D, Matthes G, Hinz P, Ekkernkamp A, Ostermann PAW (2003) Retrograde fixation of distal femoral fractures: results using a new nail system. J Orthop Trauma 17(7):488\u2013495","journal-title":"J Orthop Trauma"},{"key":"1335_CR10","unstructured":"Browner BD, Jupiter JB, Krettek C, and Anderson PA Skeletal Trauma: Basic Science, Management, and Reconstruction, 2-Volume Set."},{"issue":"1","key":"1335_CR11","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1186\/s10195-021-00593-9","volume":"22","author":"L Meccariello","year":"2021","unstructured":"Meccariello L et al (2021) Locking retrograde nail, non-locking retrograde nail and plate fixation in the treatment of distal third femoral shaft fractures: radiographic, bone densitometry and clinical outcomes. J Orthop Traumatol 22(1):33. https:\/\/doi.org\/10.1186\/s10195-021-00593-9","journal-title":"J Orthop Traumatol"},{"issue":"3","key":"1335_CR12","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1016\/j.asej.2018.12.005","volume":"10","author":"N Fouda","year":"2019","unstructured":"Fouda N, Mostafa R, Saker A (2019) Numerical study of stress shielding reduction at fractured bone using metallic and composite bone-plate models. Ain Shams Eng J 10(3):481\u2013488. https:\/\/doi.org\/10.1016\/j.asej.2018.12.005","journal-title":"Ain Shams Eng J"},{"issue":"2","key":"1335_CR13","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1177\/0954411920964628","volume":"235","author":"T \u00c7elik","year":"2020","unstructured":"\u00c7elik T (2020) Biomechanical evaluation of the screw preload values used in the plate placement for bone fractures. Proc Inst Mech Eng Part H J Eng Med 235(2):141\u2013147. https:\/\/doi.org\/10.1177\/0954411920964628","journal-title":"Proc Inst Mech Eng Part H J Eng Med"},{"key":"1335_CR14","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1097\/00003086-199802000-00007","volume":"347","author":"J Schatzker","year":"1998","unstructured":"Schatzker J (1998) Fractures of the distal femur revisited. Clin Orthop Relat Res 347:43\u201356","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"1335_CR15","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1302\/0301-620X.78B1.0780110","volume":"78","author":"MS Butt","year":"1996","unstructured":"Butt MS, Krikler SJ, Ali MS (1996) Displaced fractures of the distal femur in elderly patients. Operative versus non-operative treatment. J Bone Joint Surg Br 78(1):110\u2013114","journal-title":"J Bone Joint Surg Br"},{"issue":"2","key":"1335_CR16","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1016\/j.medengphy.2003.10.006","volume":"26","author":"G Cheung","year":"2004","unstructured":"Cheung G, Zalzal P, Bhandari M, Spelt JK, Papini M (2004) Finite element analysis of a femoral retrograde intramedullary nail subject to gait loading. Med Eng Phys 26(2):93\u2013108. https:\/\/doi.org\/10.1016\/j.medengphy.2003.10.006","journal-title":"Med Eng Phys"},{"key":"1335_CR17","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1097\/00003086-198611000-00003","volume":"212","author":"RR Tarr","year":"1986","unstructured":"Tarr RR, Wiss DA (1986) The mechanics and biology of intramedullary fracture fixation. Clin Orthop Relat Res 212:10\u201317. https:\/\/doi.org\/10.1097\/00003086-198611000-00003","journal-title":"Clin Orthop Relat Res"},{"issue":"7","key":"1335_CR18","doi-asserted-by":"publisher","first-page":"1282","DOI":"10.1007\/s00167-011-1738-z","volume":"20","author":"Y Hoshino","year":"2012","unstructured":"Hoshino Y, Wang JH, Lorenz S, Fu FH, Tashman S (2012) Gender difference of the femoral kinematics axis location and its relation to anterior cruciate ligament injury: a 3D-CT study. Knee Surg Sports Traumatol Arthrosc 20(7):1282\u20131288. https:\/\/doi.org\/10.1007\/s00167-011-1738-z","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"6","key":"1335_CR19","doi-asserted-by":"publisher","first-page":"e0128877","DOI":"10.1371\/journal.pone.0128877","volume":"10","author":"L Yin","year":"2015","unstructured":"Yin L, Chen K, Guo L, Cheng L, Wang F, Yang L (2015) Identifying the functional flexion-extension axis of the knee: an in-vivo kinematics study. PLoS ONE 10(6):e0128877. https:\/\/doi.org\/10.1371\/journal.pone.0128877","journal-title":"PLoS ONE"},{"key":"1335_CR20","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0000000000001063","author":"EG Meinberg","year":"2018","unstructured":"Meinberg EG, Agel J, Roberts CS, Karam MD, Kellam JF (2018) Fracture and dislocation classification compendium\u20142018. J Orthop Trauma. https:\/\/doi.org\/10.1097\/BOT.0000000000001063","journal-title":"J Orthop Trauma"},{"key":"1335_CR21","doi-asserted-by":"publisher","first-page":"104847","DOI":"10.1016\/j.jmbbm.2021.104847","volume":"124","author":"O Subasi","year":"2021","unstructured":"Subasi O, Oral A, Noyan S, Tuncozgur O, Lazoglu I (2021) In silico analysis of modular bone plates. J Mech Behav Biomed Mater 124:104847. https:\/\/doi.org\/10.1016\/j.jmbbm.2021.104847","journal-title":"J Mech Behav Biomed Mater"},{"key":"1335_CR22","unstructured":"AO foundation surgery reference. https:\/\/surgeryreference.aofoundation.org\/orthopedic-trauma\/adult-trauma. Accessed 01 Jul 2021"},{"issue":"5","key":"1335_CR23","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1016\/1350-4533(95)97314-F","volume":"17","author":"JY Rho","year":"1995","unstructured":"Rho JY, Hobatho MC, Ashman RB (1995) Relations of mechanical properties to density and CT numbers in human bone. Med Eng Phys 17(5):347\u2013355. https:\/\/doi.org\/10.1016\/1350-4533(95)97314-F","journal-title":"Med Eng Phys"},{"issue":"2","key":"1335_CR24","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1007\/s13246-017-0539-1","volume":"40","author":"T \u00c7elik","year":"2017","unstructured":"\u00c7elik T, Mutlu \u0130, \u00d6zkan A, Ki\u015fio\u011flu Y (2017) The effect of cement on hip stem fixation: a biomechanical study. Australas Phys Eng Sci Med 40(2):349\u2013357. https:\/\/doi.org\/10.1007\/s13246-017-0539-1","journal-title":"Australas Phys Eng Sci Med"},{"issue":"11","key":"1335_CR25","doi-asserted-by":"publisher","first-page":"2467","DOI":"10.1016\/j.jbiomech.2006.11.012","volume":"40","author":"A Completo","year":"2007","unstructured":"Completo A, Fonseca F, Sim\u00f5es JA (2007) Experimental validation of intact and implanted distal femur finite element models. J Biomech 40(11):2467\u20132476. https:\/\/doi.org\/10.1016\/j.jbiomech.2006.11.012","journal-title":"J Biomech"},{"issue":"5","key":"1335_CR26","doi-asserted-by":"publisher","first-page":"1420","DOI":"10.1007\/s00167-016-4367-8","volume":"26","author":"N Conlisk","year":"2018","unstructured":"Conlisk N, Howie CR, Pankaj P (2018) Optimum stem length for mitigation of periprosthetic fracture risk following primary total knee arthroplasty: a finite element study. Knee Surg Sport Traumatol Arthrosc 26(5):1420\u20131428. https:\/\/doi.org\/10.1007\/s00167-016-4367-8","journal-title":"Knee Surg Sport Traumatol Arthrosc"},{"issue":"8","key":"1335_CR27","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1097\/00005131-200409000-00003","volume":"18","author":"KA Egol","year":"2004","unstructured":"Egol KA, Kubiak EN, Fulkerson E, Kummer FJ, Koval KJ (2004) Biomechanics of locked plates and screws. J Orthop Trauma 18(8):488\u2013493. https:\/\/doi.org\/10.1097\/00005131-200409000-00003","journal-title":"J Orthop Trauma"},{"key":"1335_CR28","doi-asserted-by":"publisher","DOI":"10.3923\/jms.2007.460.467","author":"ZR Mi","year":"2007","unstructured":"Mi ZR, Shuib S, Hassan AY, Shorki AA, Ibrahim MM (2007) Problem of stress shielding and improvement to the hip implant designs: a review. J Med Sci. https:\/\/doi.org\/10.3923\/jms.2007.460.467","journal-title":"J Med Sci"},{"key":"1335_CR29","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/j.ijscr.2020.04.060","volume":"70","author":"H Kodama","year":"2020","unstructured":"Kodama H, Saku I, Tomoyama S (2020) Surgical treatment of femoral medial condyle fracture with lag screws and proximal tibial plate: a case report. Int J Surg Case Rep 70:101\u2013105. https:\/\/doi.org\/10.1016\/j.ijscr.2020.04.060","journal-title":"Int J Surg Case Rep"},{"issue":"1","key":"1335_CR30","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1186\/s13018-018-0756-7","volume":"13","author":"W Xing","year":"2018","unstructured":"Xing W et al (2018) Clinical effect of locking compression plate via posterolateral approach in the treatment of distal femoral fractures: a new approach. J Orthop Surg Res 13(1):57. https:\/\/doi.org\/10.1186\/s13018-018-0756-7","journal-title":"J Orthop Surg Res"},{"issue":"6","key":"1335_CR31","doi-asserted-by":"publisher","first-page":"864","DOI":"10.2106\/00004623-198264060-00008","volume":"64","author":"JB Giles","year":"1982","unstructured":"Giles JB, DeLee JC, Heckman JD, Keever JE (1982) Supracondylar-intercondylar fractures of the femur treated with a supracondylar plate and lag screw. J Bone Joint Surg Am 64(6):864\u2013870","journal-title":"J Bone Joint Surg Am"},{"issue":"3","key":"1335_CR32","doi-asserted-by":"publisher","first-page":"341","DOI":"10.2106\/00004623-199173030-00004","volume":"73","author":"R Sanders","year":"1991","unstructured":"Sanders R, Swiontkowski M, Rosen H, Helfet D (1991) Double-plating of comminuted, unstable fractures of the distal part of the femur. J Bone Joint Surg Am 73(3):341\u2013346","journal-title":"J Bone Joint Surg Am"},{"issue":"2","key":"1335_CR33","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1097\/00005131-199504000-00011","volume":"9","author":"K Firoozbakhsh","year":"1995","unstructured":"Firoozbakhsh K, Behzadi K, DeCoster TA, Moneim MS, Naraghi FF (1995) Mechanics of retrograde nail versus plate fixation for supracondylar femur fractures. J Orthop Trauma 9(2):152\u2013157. https:\/\/doi.org\/10.1097\/00005131-199504000-00011","journal-title":"J Orthop Trauma"},{"issue":"Suppl 1","key":"1335_CR34","doi-asserted-by":"publisher","first-page":"A31","DOI":"10.1016\/s0020-1383(97)90113-3","volume":"28","author":"C Krettek","year":"1997","unstructured":"Krettek C, Schandelmaier P, Miclau T, Bertram R, Holmes W, Tscherne H (1997) Transarticular joint reconstruction and indirect plate osteosynthesis for complex distal supracondylar femoral fractures. Injury 28(Suppl 1):A31-41. https:\/\/doi.org\/10.1016\/s0020-1383(97)90113-3","journal-title":"Injury"},{"issue":"Suppl 1","key":"1335_CR35","first-page":"118","volume":"59","author":"R Huiskes","year":"1993","unstructured":"Huiskes R (1993) Stress shielding and bone resorption in THA: clinical versus computer-simulation studies. Acta Orthop Belg 59(Suppl 1):118\u2013129","journal-title":"Acta Orthop Belg"},{"key":"1335_CR36","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1097\/00003086-199201000-00014","volume":"274","author":"R Huiskes","year":"1992","unstructured":"Huiskes R, Weinans H, van Rietbergen B (1992) The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin Orthop Relat Res 274:124\u2013134","journal-title":"Clin Orthop Relat Res"},{"key":"1335_CR37","doi-asserted-by":"publisher","DOI":"10.1115\/14027669","author":"ZS Bagheri","year":"2014","unstructured":"Bagheri ZS, Tavakkoli Avval P, Bougherara H, Aziz MSR, Schemitsch EH, Zdero R (2014) Biomechanical analysis of a new carbon fiber\/flax\/epoxy bone fracture plate shows less stress shielding compared to a standard clinical metal plate. J Biomech Eng. https:\/\/doi.org\/10.1115\/14027669","journal-title":"J Biomech Eng"},{"key":"1335_CR38","doi-asserted-by":"publisher","first-page":"S44","DOI":"10.1016\/S0020-1383(18)30302-4","volume":"49","author":"U Kandemir","year":"2018","unstructured":"Kandemir U (2018) Distal femur: dynamization of plating. Injury 49:S44\u2013S48. https:\/\/doi.org\/10.1016\/S0020-1383(18)30302-4","journal-title":"Injury"},{"issue":"1","key":"1335_CR39","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1186\/1752-2897-6-6","volume":"6","author":"D Vos","year":"2012","unstructured":"Vos D, Hanson B, Verhofstad M (2012) Implant removal of osteosynthesis: the Dutch practice. Results of a survey. J Trauma Manag Outcomes 6(1):6. https:\/\/doi.org\/10.1186\/1752-2897-6-6","journal-title":"J Trauma Manag Outcomes"},{"issue":"7","key":"1335_CR40","doi-asserted-by":"publisher","first-page":"785","DOI":"10.1016\/j.otsr.2015.07.021","volume":"101","author":"FM Kovar","year":"2015","unstructured":"Kovar FM, Strasser E, Jaindl M, Endler G, Oberleitner G (2015) Complications following implant removal in patients with proximal femur fractures\u2014an observational study over 16years. Orthop Traumatol Surg Res 101(7):785\u2013789. https:\/\/doi.org\/10.1016\/j.otsr.2015.07.021","journal-title":"Orthop Traumatol Surg Res"},{"issue":"7","key":"1335_CR41","doi-asserted-by":"publisher","first-page":"783","DOI":"10.1016\/j.medengphy.2010.05.003","volume":"32","author":"H Fouad","year":"2010","unstructured":"Fouad H (2010) Effects of the bone-plate material and the presence of a gap between the fractured bone and plate on the predicted stresses at the fractured bone. Med Eng Phys 32(7):783\u2013789. https:\/\/doi.org\/10.1016\/j.medengphy.2010.05.003","journal-title":"Med Eng Phys"},{"issue":"11\u201312","key":"1335_CR42","doi-asserted-by":"publisher","first-page":"939","DOI":"10.3139\/120.110942","volume":"58","author":"SA Asiri","year":"2016","unstructured":"Asiri SA, Hedia HS, Fouda N (2016) Improving the performance of cementless knee prosthesis coating through functionally graded material. Mater Test 58(11\u201312):939\u2013945. https:\/\/doi.org\/10.3139\/120.110942","journal-title":"Mater Test"},{"issue":"3","key":"1335_CR43","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1016\/s0020-1383(80)80044-1","volume":"11","author":"H Brunner","year":"1980","unstructured":"Brunner H, Simpson JP (1980) Fatigue fracture of bone plates. Injury 11(3):203\u2013207. https:\/\/doi.org\/10.1016\/s0020-1383(80)80044-1","journal-title":"Injury"},{"issue":"2","key":"1335_CR44","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/0142-9612(87)90106-2","volume":"8","author":"AA Amis","year":"1987","unstructured":"Amis AA, Bromage JD, Larvin M (1987) Fatigue fracture of a femoral sliding compression screw-plate device after bone union. Biomaterials 8(2):153\u2013157. https:\/\/doi.org\/10.1016\/0142-9612(87)90106-2","journal-title":"Biomaterials"},{"issue":"3","key":"1335_CR45","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1007\/s43465-020-00291-4","volume":"55","author":"J Yoo","year":"2021","unstructured":"Yoo J, Ma X, Lee J, Hwang J (2021) Research update on stress riser fractures. Indian J Orthop 55(3):560\u2013570. https:\/\/doi.org\/10.1007\/s43465-020-00291-4","journal-title":"Indian J Orthop"},{"key":"1335_CR46","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1016\/j.medengphy.2005.06.003","volume":"28","author":"L Peng","year":"2006","unstructured":"Peng L, Bai J, Zeng XL, Zhou YX (2006) Comparison of isotropic and orthotropic material property assignments on femoral finite element models under two loading conditions. Med Eng Phys 28:227\u2013233","journal-title":"Med Eng Phys"}],"container-title":["Physical and Engineering Sciences in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-023-01335-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s13246-023-01335-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13246-023-01335-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,7]],"date-time":"2023-12-07T10:34:47Z","timestamp":1701945287000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s13246-023-01335-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,23]]},"references-count":46,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2023,12]]}},"alternative-id":["1335"],"URL":"https:\/\/doi.org\/10.1007\/s13246-023-01335-3","relation":{},"ISSN":["2662-4729","2662-4737"],"issn-type":[{"type":"print","value":"2662-4729"},{"type":"electronic","value":"2662-4737"}],"subject":[],"published":{"date-parts":[[2023,10,23]]},"assertion":[{"value":"27 December 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 September 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 October 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Author Ayberk Dizdar declares that he has no conflict of interest. Author Talip Celik declares that he has no conflict of interest. Author Arif Ozkan declares that he has no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This\u00a0article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}